Douglas DC-9-14
Service difficulty reports · 1,736
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC914' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC914' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 9619019163Wire · brokenDURING LINE CHECK, FOUND EMERGENCY ESCAPE PATH LIGHTS INOPERATIVE FROM ROW 2 FORWARD. FOUND WIRE MISSING BETWEEN ROWS 1 AND 2. REPLACED WIRES, OPERATIONAL CHECK OK.SDR 9618349162Gyro · inoperativeDURING CRUISE, CAPTAIN'S GYRO BECAME INOPERATIVE. FLIGHT RETURNED TO DTW AND LANDED WITHOUT INCIDENT. REPLACED GYRO.SDR MWEA96407Relay · inoperativeDURING OPS TEST OF EMERGENCY LIGHTS, FOUND FOUR FWD CABIN CEILING LIGHTS INOP AND LT NACELLE LIGHT INOP. REPLACED TWO BATTERIES IN POWER SUPPLY AND R2-215 RELAY FOR LT EMERGENCY NACELLE FLOODLIGHT.SDR MWEA96404Ballast · failedEMERGENCY LIGHTS WOULD NOT EXTINGUISH WITH ALL POWER OFF ON A/C. REPLACED LIGHT BALLAST, REPLACED LOANER UNIT 8/10/96.SDR MWEA96402Slide Cover · fell offCREW REPORTS, GALLEY SERVICE DOOR EVAC SLIDE COVER FALLING OFF. REINSTALLED GALLEY DOOR SLIDE COVER.SDR 9617179140Light · inoperativeDURING LINE CHECK, FOUND LEFT NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED LEFT NACELLE EMERGENCY LIGHT BATTERY PACK, OPERATIONAL CHECK OK.SDR 9618629154Longeron · corrodedDURING H-CHECK, FOUND CORROSION ON THE RIGHT WING LOWER STRINGERS: NR 11-15 BETWEEN XRS 91-111. NR 17 BETWEEN XRS 88-111. NR 19 BETWEEN XRS 91-96. NR 21 BETWEEN XRS 69-111. REPAIRED STRINGERS PER EA 91-110868.SDR 9619029154Longeron · corrodedDURING H-CHECK, FOUND CORROSION ON THE RIGHT WING LOWER STR 15 AND 17 FROM WING STA 84 TO 111. REPAIRED STRINGERS (P/N 5911276-502, 5911278-2) PER EA 91-110863, 110864.SDR 9618619154Longeron · corrodedDURING H-CHECK, FOUND CORROSION ON THE RIGHT WING LOWER STR 14 FROM XRS 91 - 111. REPAIRED STRINGER (P/N 591277-502) PER EA 91-110862.SDR 9617539154Longeron · corrodedDURING H-CHECK, FOUND CORROSION IN THE LEFT WING STRINGER 17 BETWEEN XRS 69 TO 91. REPAIRED STRINGER (P/N 5911278-1) PER EA 91-110877.SDR 9617529154Longeron · corrodedDURING H-CHECK, FOUND CORROSION IN THE LEFT WING STRINGER 15 AT XRS 79. REPAIRED STRINGER (P/N 5911276-501) PER EA 91-110874.SDR 9617519154Longeron · corrodedDURING H-CHECK, FOUND CORROSION ON THE LEFT WING STRINGER 14 BETWEEN XRS 73 TO 76. REPAIRED STRINGER (P/N 5911277-501) PER EA 91-110852.SDR MWEA96270Door Pan · crackedDURING INSPECTION, FOUND FORWARD CARGO DOOR INNER PAN CRACKED NEAR AFT LOCKING CAM. INSTALLED REPAIR IAW SRM 52-05, FIG. 26A.SDR MWEA96269Door Pan · crackedDURING INSPECTION FOUND AFT CARGO DOOR PAN CRACKED AT BEAM 5 AFT END OF DOOR. INSTALLED DOUBLER REPAIR IAW SRM 52-03, FIG. 8, SHEETS 1 AND 2.SDR 9616119153Battery Pack · dischargedDURING LINE CHECK, FOUND COCKPIT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK OK.SDR 9616109156Radar Antenna · malfunctionedDURING CLIMB-OUT OF MSP, RADAR PICTURE WAS VERY POOR, PAINTS SOME WEATHER BUT ALWAYS SPOKING. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. REPLACED RADAR ANTENNA AND TRANSCEIVER. RADAR OPERATIONALLY CHECKED GOOD ON GROUND.SDR 9616099156Radar Tr Unit · failedAFTER DEPARTURE, RADAR WOULD NOT PAINT WEATHER OR GROUND RETURNS. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. REPLACED TRANSCEIVER AND RADAR INDICATOR. SYSTEM CHECKS WERE NORMAL ON GROUND IN TEST PATTERN. OPERATIONAL CHECK OK.SDR 9616739154Press Panel · crackedDURING H-CHECK, FOUND A CRACK IN THE NOSE LANDING GEAR WHEEL WELL HORIZONTAL PRESSURE PANEL AT THE LEFT OUTBOARD VERTICAL STIFFENER FS 105. REPAIRED PANEL (P/N 9910073-313) PER EA 91-110860.SDR 9616719154Bulkhead Angle · crackedDURING H-CHECK, FOUND A CRACK IN THE NOSE LANDING GEAR WHEEL WELL RIGHT INBOARD BULKHEAD UPPER ATTACH ANGLE FS 76. REPAIRED ANGLE (P/N 9910073-60) PER EA 91-110861.SDR 9616709154Skin · corrodedDURING H-CHECK, FOUND CORROSION ON THE FUSELAGE SKIN AT THE ANTENNA DOUBLERS FS 444 TO 468, LONGERON 29L TO 30. REPAIRED SKIN (P/N 5911412-3) PER EA 91-110858.SDR 9615189150Relay · failedDURING APPROACH, ALL COCKPIT LIGHTS BEGAN FLASHING ACCOMPANIED BY LEFT GENERATOR OFF, LEFT AC BUS OFF AND CROSSTIE LOCKOUT ANNUNCIATOR LIGHTS FLASHING RAPIDLY. LEFT GENERATOR WAS TURNED OFF AND APU WAS STARTED TO POWER LEFT BUS. CREW REQUESTED EMERGENCY EQUISDR 9616699154Skin · corrodedDURING H-CHECK, FOUND CORROSION ON THE FUSELAGE SKIN AT FS 718 BETWEEN LONGERONS 28R TO 29R. REPAIRED SKIN (P/N 5911425-3) PER EA 91-109073.SDR 9616689154Doubler · corrodedDURING H-CHECK, FOUND CORROSION IN THE AFT CARGO DOOR JAMB DOUBLER LOWER FORWARD CORNER. REPAIRED DOUBLER (P/N 5910158-25) PER EA 91-110856.SDR 9615439154Fitting · corrodedDURING H-CHECK, FOUND CORROSION ON THE FS 802 FRAME TO RIGHT CUSP FITTING. REPLACED FITTING PER SRM 51-30.SDR MWEA96260Light · inoperativeDURING INSP, FOUND LT AND RT OVERWING WING EMERGENCY LIGHTS INOP. CHANGED AND ARMED THE SYSTEM, OPS CHECK GOOD.SDR MWEA96257Power Supply · inoperativeDURING INSPECTION, FOUND AFT TWO LIGHTS ON EMERGENCY FLOOR TRACK LIGHTING INOP. REPLACED BATTERY POWER SUPPLY, OPS CHECK GOOD.SDR 9614549150Light · inoperativeDURING LINE CHECK, FOUND TAIL COMPARTMENT OVERHEAD EMERGENCY LIGHTS INOPERATIVE AT STA 996. REWIRED LIGHT ASSEMBLY, OPERATIONAL CHECK OK.SDR 9614089153Battery Pack · dischargedDURING LINE CHECK, FOUND RIGHT ENGINE NACELLE EMERGENCY ILLUMINATION LIGHT INOPERATIVE. REPLACED RIGHT NACELLE LIGHT BATTERY PACK, OPERATIONAL CHECK OK.SDR 9614079178Lights · inoperativeDURING LINE CHECK, FOUND ESCAPE PATH LIGHTING INOPERATIVE AT ROW 5. REPLACED SOCKET, OPERATIONAL CHECK OK.SDR MWEA96161Battery · dischargedDURING C-CHECK, THE EMERGENCY LIGHTS IN CEILING FROM FWD TO ROW 9 AND OVERHEAD LIGHT IN AFT ACCESSORY COMPT WOULD NOT ILLUMINATE. REPLACED BATTERIES, OPS CHECK GOOD.SDR MWEA96160Frame · crackedDURING C-CHECK, FOUND FRAME CRACKED AT STA 880 L19R. INSTALLED REPAIR IAW SRM 53-01, FIG 2, SHEET 4.SDR 9613299152Battery Pack · dischargedDURING LINE CHECK, FOUND TAIL COMPARTMENT OVERHEAD EMERGENCY LIGHTS AND AFT RIGHT AISLE OVERHEAD EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK B5-28. ALL EMERGENCY LIGHTS CHECKED OK.SDR MWEA96159Doubler · crackedDURING C-CHECK, FOUND CRACK 1 INCH LONG ON EXISTING REPAIR DOUBLER AT THE VERTICAL STAB RT ATTACH ANGLE IN AFT ACCESSORY COMPT. FABRICATED AND INSTALLED REPAIR DOUBLER PER SRM 51-30.SDR MWEA96158Battery Pack · dischargedDURING SERVICE CHECK, FOUND OVERHEAD EMER LIGHTS AT EMER EXIT ROW WOULD NOT EXTINGUISH WHEN POWER REMOVED. REPLACED BATTERY POWER SUPPLY FOR LIGHTS AFFECTED, OPS CHECK GOOD.SDR 9613059178Battery Pack · dischargedDURING LINE CHECK, FOUND RIGHT NACELLE EMERGENCY LIGHT OUT. REPLACED BATTERY PACK, OPERATIONAL CHECK OK.SDR 9612899155Battery Pack · dischargedDURING LINE CHECK, FOUND RIGHT TAILCONE EMERGENCY SLIDE LIGHT AND RIGHT NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK IN POWER SUPPLY, OPERATIONAL CHECK OK.SDR 9612889155Battery Pack · dischargedDURING LINE CHECK, FOUND LEFT TAILCONE EMERGENCY SLIDE LIGHT AND LEFT NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK IN POWER SUPPLY, OPERATIONAL CHECK OK.SDR MWEA96155Slide Cover · fell offCREW REPORTS GALLEY SERVICE DOOR EVAC SLIDE COVER FELL OFF. REINSTALLED GALLEY SERVICE DOOR EVAC SLIDE COVER.SDR MWEA96153Skin · damagedLEADING EDGE OF LT WING SUSTAINED DAMAGE AFTER STRIKING VEHICLE JUST BEFORE PARKING AT JETWAY. INSTALLED DOUBLER REPAIR IAW SRM 57-06, FIG 2.SDR MWEA96147Evac Slide Cover · fell offCREW REPORTS, GALLEY DOOR EVACUATION SLIDE COVER FELL OFF. REINSTALLED GALLEY DOOR EVACUATION SLIDE COVER.SDR MWEA96145Power Supply · inoperativeMKE - DURING SERVICE CHECK, FOUND RT EMERGENCY NACELLE LIGHT WOULD NOT ILLUMINATE DURING TEST. REPLACED NACELLE LIGHT POWER SUPPLY. OPS CHECK GOOD. RETURNED A/C TO SERVICE. (X)SDR 9611999154Battery Pack · looseDURING LINE CHECK, FOUND RIGHT EMERGENCY OVERWING EXIT LIGHT DOES NOT ILLUMINATE DURING TEST. RESEATED BATTERY PACK, OPERATIONAL CHECK OK.SDR 9611449152Amplifier · malfunctionedDURING CLIMBOUT, CABIN PRESSURE WARNING LIGHT ILLUMINATED WITH CABIN DECOMPRESSION. MASKS DEPLOYED, CABIN CONTROLLED MANUALLY AND ACFT RETURNED TO DSM AND LANDED WITHOUT INCIDENT. FOUND CIRCUIT BREAKER Z-31 POPPED. REPLACED THE PRESSURE AMPLIFIER AND RESET SDR 9610829162Power Supply · inoperativeDURING LINE CHECK, FOUND AFT SECTION OF DISCO LIGHTS INOPERATIVE. REPLACED POWER SUPPLIES AND BATTERIES. OPERATIONAL CHECK OK.SDR 9610519140Battery Pack · dischargedDURING LINE CHECK, FOUND INTERIOR TAIL CONE EMERGENCY SLIDE LIGHTS AND NACELLE LIGHTS INOPERATIVE. REPLACED BATTERY PACKS IN POWER SUPPLIES B5-49 AND B5-50, OPERATIONAL CHECK OK.SDR 9610529140Battery Pack · dischargedDURING LINE CHECK, FOUND LEFT AND RIGHT NACELLE EMERGENCY LIGHTS OUT. REPLACED BATTERY PACK, OPERATIONAL CHECK OK.SDR MWEA96133Connector · corrodedA/C DIVERTED TO MKE, LT ENG FIRE LOOP-B FLICKERING AMBER LIGHT AND ANNUNCIATOR LIGHT, SELECTED A-LOOP LT ENG, IT WOULD NOT TEST. REPAIRED CHAFING WIRE NEAR FWD PYLON CONNECTOR FOR LOOP-B. SLIGHT CORROSION IN CANNON PLUG IN PYLON FOR LOOP-A. CLEANED CANNON PSDR 9610229180Battery Pack · dischargedDURING LINE CHECK, FOUND RIGHT NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK, OPERAITONAL CHECK GOOD.SDR MWEA96132Ground Wire · not attachedWITH B-LOOP DEFERRED FROM PREVIOUS WRITEUP AND AT CRUISE ALTITUDE, A-LOOP WOULD NOT TEST ON LT ENGINE. FOUND GROUND WIRE ON FIRE LOOP NOT GROUNDED. FIXED WIRE AND REATTACHED GROUND.SDR 9610219140Battery Pack · dischargedDURING LINE CHECK, FOUND LEFT AND RIGHT EXTERIOR EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACKS, OPERATIONAL CHECK GOOD.
Back to Douglas DC-9-14