Douglas DC-9-31
Service difficulty reports · 7,433
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC931' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC931' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 9620709974Fitting · crackedDURING M-CHECK, FOUND CRACKS IN THE AFT ENTRY DOOR FITTINGS. REPLACED FITTINGS (P/N 3917624-521 AND 4917851-501) PER SRM 51-30.SDR 9620699910Fitting · corrodedDURING H-CHECK, FOUND CORROSION ON THE LONGERON 30 RIGHT KEEL TO FS 622 FRAME ATTACH FITTING. REPLACED FITTING (P/N 9910164-85) PER SRM 51-01.SDR 9620589946Lights · looseDURING LINE MAINTENANCE INSPECTION, FOUND TAILCONE EMERGENCY LIGHT AND POWER SUPPLY LOOSE FROM BRACKET. REPLACED POWER SUPPLY AND BATTERIES, OPERATIONAL CHECK NORMAL.SDR 9620579963Power Supply · inoperativeDURING LINE MAINTENANCE INSPECTION, FOUND AFT EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED POWER SUPPLY, OPERATIONAL CHECK NORMAL.SDR 9620569930Anti-Ice Valve · malfunctionedAIRFOIL ICE PROTECTION PRESSURE ABNORMAL LIGHT ILLUMINATED WITH TAIL ANTI-ICE SELECTED AFTER TAKEOFF. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED WING ANTI-ICE VALVE, OPERATIONAL CHECK NORMAL.SDR USAAD96132Tire · failedFLT 1544 - ABE-PIT - ON DEPARTURE, CREW BELIEVED A NOSE TIRE HAD BLOWN. DIVERTED TO PHL WITH GEAR DOWN. NO GREEN DOWN ADN LOCKED LIGHT WAS OBSERVED ON LEFT MAIN GEAR. FOUND LEFT MAIN INBOARD TIRE RECAP FAILED. ALSO, FOUND LEFT MAIN GEAR DOWNLOCK SWITCH HARSDR USAAD96131Battery Pack · dischargedGALLEY DOOR EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK. (M)SDR GTIA96NK206Pack · smokingAFTER LANDING AND BLOCK IN RSW. APPEARS TO HAVE A TRACE OF SMOKE IN CABIN AREA WITH PACK OPERATING. INSPECTED AND OPERATED BOTH LEFT AND RIGHT PACKS USING RIGHT PACK IN NORMAL. ALL OPERATIONS AND INDICATIONS ARE NORMAL, IAW CHAP 21. NO SMOKE IN CABIN NOTEDSDR ABXA9701010Skin · crackedFOUND DOOR PAN, AND INNER SKIN CRACKED. REPAIRED IAW ABX REA D952-16211-MR, AND DC9 SRM 52-01.SDR 9621229910Bulkhead Web · crackedDURING H-CHECK, FOUND A CRACK IN THE FS 218 BULKHEAD WEB AT RBL 44. REPAIRED WEB (P/N 9911520-173) PER EA 99-106321.SDR USAA960628Skin · crackedPIT - DURING C-2 CHECK, FOUND .5 INCH CRACK IN FUSELAGE SKIN AT STATION 354 LONGERON 6L. CUT OUT CRACKED AREA, INSTALLED A FILLER AND AN EXTERNAL DOUBLER WITH BLIND FASTENERS PER SRM 53-04 FIG 12B SHEET 16 (CLASS III REPAIR). (M)SDR USAA960627Skin · crackedPIT - DURING C-2 CHECK, FOUND .4375 INCH CRACK IN FUSELAGE SKIN AT STATION 658 BETWEEN R1 AND R2. DETECTED BY EDDY CURRENT. CUT OUT CRACKED AREA. INSTALLED A FILLER AND AN EXTERNAL DOUBLER WITH BLIND FASTENER PER SRM 53-04 FIG 12B SHEET 16 (CLASS II REPAIR)SDR 9620389908Battery Pack · dischargedDURING PERIODIC CHECK, THE RIGHT NACELLE EMERGENCY LIGHTS FAILED TEN MINUTE TEST. REPLACED BATTERY PACK, OPERATIONAL CHECK NORMAL.SDR 96ZZZM1457Longeron · corrodedSTL - DURING OP-15, FOUND CORROSION, LONGERON 30, STATION 855 TO 955. REPAIRED PER SRM 51-10-4 AND 51-30-5.SDR 9620479910Fittings · corrodedDURING H-CHECK, FOUND CORROSION ON THE LEFT AND RIGHT LONGERON 30 KEEL BEAM FITTINGS FROM FS 742 TO 755. REPLACED FITTINGS PER SRM 51-01 PG 1.SDR 9620299977Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD CABIN EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK, OPERATIONAL CHECK NORMAL.SDR 9620279936Power Supply · inoperativeDURING LINE MAINTENANCE INSPECTION, FOUND TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY B5-28, OPERATIONAL CHECK NORMAL.SDR USAA960624Doubler · crackedPIT - DURING Q-3/C-2 CHECK, FOUND .5 INCH CRACK LOWER WING SKIN PLATE DOUBLER AT LOWER WING ACCESS PLATE 1456A DOUBLER. INSTALLED DOUBLERS PER SRM 57-03 FIG 29A AND EA 33614. (M)SDR USAA960623Frame · crackedPIT - DURING Q3-C2 CHECK, FOUND 3 INCH CRACK IN FRAME WEB STATION 1038 LONGERON 5L AND 9L. SPLICED IN SECTION OF WEB PER EA NR 33533. (M)SDR 96ZZZM1459Longeron · crackedSTL - DURIGN OP-15, FOUND A ONE INCH CRACK IN LOWER FLANGE OF LONGERON 6L, STATION 617. REPAIRED PER SRM 53-02, FIGURE 2. (M)SDR 9621219910Frame · crackedDURING H-CHECK, FOUND A .75 INCH CRACK IN THE FS 1019 FRAME FORMER AT LONGERON 14R. REPAIRED FORMER (P/N 9958239-12) PER EA 99-110350.SDR 9621209910Fitting · crackedDURING H-CHECK, FOUND THE LONGERON 30 KEEL FITTINGS DAMAGED AT FS 606; A CRACK IN THE LEFT FITTING AND CORROSION ON THE RIGHT FITTING. REPLACED BOTH FITTINGS.SDR 9620289955Batteries · dischargedEMERGENCY LIGHTS IN GALLEY AND FIRST CLASS ILLUMINATED WITH NO SWITCHES ACTIVATED. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.SDR 9620239989Oil Filter · contaminatedDURING TAKEOFF ROLL, THE RIGHT ENGINE OIL STRAINER CLOG LIGHT ILLUMINATED. CREW ABORTED TAKEOFF AND RETURNED TO THE GATE. MAINTENANCE REPLACED THE RIGHT ENGINE MAIN OIL STRAINER, LEAK AND OPERATIONAL CHECK OK.SDR 9620259856Pump · failedDURING CRUISE, THE RIGHT HYDRAULIC SYSTEM QUANTITY AND PRESSURE WENT TO ZERO. FLIGHT RETURNED TO MEM AND LANDED WITHOUT INCIDENT. REPLACED THE RIGHT EDP AND FILTERS. REPLACED RIGHT AUXILIARY PUMP AND FILTERS AND PRESSURE LINE FROM AUXILIARY PUMP. SERVICEDSDR 9620229976Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND AFT INTERIOR OVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACKS, OPERATIONAL CHECK NORMAL.SDR 9620219976Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND UPPER CABIN AFT OF OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED BATTERY PACK, OPERATIONAL CHECK NORMAL.SDR 9620209976Wire · looseDURING LINE MAINTENANCE INSPECTION, FOUND AFT STAIRWELL EMERGENCY LIGHTS DIM. SECURED LOOSE GROUND WIRE, OPERATIONAL CHECK NORMAL.SDR ABXA9700662Longeron · corrodedDURING C-CHECK AND COMPLIANCE WITH AD 92-22-08, FOUND LEVEL 2 CORROSION ON LONGERONS 27R, SKIN AND FRAMES AT STA 160 TO 200. REPLACED IAW DC-9 SRM 51-30-2, 51-30-5.SDR 9620179970Battery · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND EMERGENCY FLASHLIGHT ABOVE FORWARD FLIGHT ATTENDANT INOPERATIVE. REPLACED BATTERY, OPERATIONAL CHECK NORMAL.SDR 9620129960Fitting · corrodedDURING M-CHECK, FOUND CORROSION ON THE CENTER WING TANK FORWARD RIGHT ATTACH FITTING FS 610. REPLACED FITTING PER SRM 51-30-5, 51-30-1.SDR USAAD96129Switch · leakingFLT 2371 - CLT-BHM - NR 2 ENGINE OIL QUANTITY STARTED DROPPING IN FLIGHT. RETURNED TO CLT. NO ENGINE SHUTDOWN. FOUND NR 2 OIL PRESSURE SWITCH LEAKING. REPLACED SWITCH. (M)SDR USAA960607Frame · crackedPIT - DURING Q-3/C2 CHECK FOUND .5 INCH CRACK AT LOWER FIXED LEADING EDGE FRAME 4 OF VERTICAL STABILIZER. REPLACED DEFECTIVE PART WITH IDENTICAL PART NR 991188411. (M)SDR USAA960606Frame · crackedPIT - DURING Q-3/C2 CHECK, FOUND .5 INCH CRACK IN LOWER FIXED LEADING EDGE FRAME 5 OF VERTICAL STABILIZER. REPLACED DEFECTIVE PART WITH IDENTICAL PART NR 991188511. (M)SDR 9620039966Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND LEFT NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK, OPERATIONAL CHECK NORMAL.SDR 9620009957Wire · corrodedDURING LINE MAINTENANCE INSPECTION, FOUND TAILCONE EMERGENCY LIGHTS INOPERATIVE. REPAIRED CORRODED SPLICE IN TAIL AREA, OPERATIONAL CHECK NORMAL.SDR 9619999903Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND OVERHEAD EMERGENCY LIGHTS IN FORWARD CABIN AND AT ROWS 13 THROUGH 14 INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.SDR 9619919967Switch · stuckDURING CLIMB, COULD NOT PRESSURIZE THE AIRCRAFT AND NOTED EXCESSIVE NOISE FROM THE AREA FORWARD OF THE INSTRUMENT PANEL. THE AUTO PRESSURIZATION AND DOOR WARNING SYSTEMS APPEARED TO BE OPERATING NORMALLY. RETURNED TO PHX WITHOUT FURTHER INCIDENT. FOUND THE SDR 9619879931Flap Pos Ind · failedAFTER TAKEOFF AND UPON FLAP RETRACTION, THE LEFT FLAP INDICATED FULL RETRACTION WITH RIGHT FLAP INDICATING 15 DEGREES. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED FLAP POSITION INDICATOR AND RESET CIRCUIT BREAKER, OPERATIONAL CHECSDR 9619819945Door Track · dirtyAFTER TAKEOFF RECEIVED AN E/E DOOR WARNING INDICATION, LIGHT EXTINGUISHED AFT PRESSURIZATION. RETURNED TO SDF WITHOUT FURTHER INCIDENT. RECYCLED THE DOOR, CLEANED DEBRIS FROM THE DOOR TRACK AND RESET THE PLUG ON THE SWITCH, CHECKED OK.SDR USAA960605Cusp · corrodedPIT - DURING Q4/C6 CHECK, FOUND CORROSION 3 INCH BY 3 INCH AREA CORRODED CUSP MEMBRANE AT STATION 204 LT TO STATION 180. INSTALLED NEW CUSP SECTION AND ADDED DOUBLERS 7075 PLUS 6 071 AND 7075 PLUS 6 .080 PER EA NR 33169/SRM 53-05 FIG 55. (M)SDR USAA960604Cusp · crackedPIT - DURING Q4/C6 CHECK, FOUND CRACKED MEMBRANE AT STATION 598 TO STATION 617 RIGHT SIDE. REMOVED CRACKED MEMBRANE AND MFG NEW SECTION OF MEMBRANE 2024 T-3 .032 PER SRM 53-05 FIG 96, 97. (M)SDR 9620029996Light · inoperativeDURING LINE MAINTENANCE INSPECTION, FOUND LEFT NACELLE EMERGENCY LIGHT INOPERATIVE. PROBLEM COULD NOT BE DUPLICATED.SDR 9620019972Light · inoperativeDURING LINE MAINTENANCE INSPECTION, FOUND OVERHEAD EMERGENCY LIGHTS AT ROWS 8 THROUGH 15 INOPERATIVE. REPLACED POWER SUPPLIES AND BATTERY PACKS, OPERATIONAL CHECK NORMAL.SDR ABXA9600623Door Open Light · illuminatedGEAR UPLATCH CHECK WAS GOOD. ABOVE APPROXIMATELY 11,000 FT, THE GEAR DOOR OPEN LIGHT ILLUMINATED. RECYCLED THE LANDING GEAR, THE LIGHT REMAINED ILLUMINATED. ON DESCENT, BELOW 11,000 FT, THE GEAR DOOR OPEN LIGHT EXTINGUISHED. CHECKED MAIN LANDING GEAR DOOR SDR 9620419912Web · crackedDURING M-CHECK, FOUND CRACKS IN THE HORIZONTAL PRESSURE PANEL AT FS 83 AT BOTH THE LEFT AND RIGHT FRAME FITTINGS. REPAIRED PANEL (P/N 9910073-3) PER EA 99-111214, 99-111215.SDR 9620409933Web · crackedDURING H-CHECK, FOUND A 6 INCH CRACK IN THE HORIZONTAL PRESSURE PANEL AT FS 83 AT THE LEFT VERTICAL FRAME ATTACH POINT. REPAIRED THE PANEL (P/N 9910073-3) PER EA 99-111213.SDR 9620119912Web · crackedDURING M-CHECK, FOUND A CRACK IN THE NOSE LANDING GEAR HORIZONTAL PRESSURE PANEL WEB AT FS 108, LBL 35. REPAIRED THE WEB (P/N 9910073-313) PER EA 99-11216.SDR 9620109912Doubler · crackedDURING M-CHECK, FOUND A CRACK IN THE EXTERIOR FUSELAGE LAVATORY SERVICE DOOR DOUBLERS, LOWER FORWARD CORNER. REPAIRED DOUBLERS (P/N 5911423-43, -99) PER EA 99-111219.SDR 9619749978Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND TAIL SECTION EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.
Back to Douglas DC-9-31