Douglas DC-9-32
Service difficulty reports · 12,755
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TWAA0015506Longeron · corrodedDURING OP 15 MAINT CHECK FOUND EXFOLIATION CORROSION AT STA 862, LONGERON 23L, AT FACTORY SPLICE. REPLACED SECTION OF LONGERON 23L FROM STA 840 TO FACTORY SPLICE AT STA 865, PER SRM 53-02 FIG 18.SDR TWAA0015505Rib · crackedDURING OP 15 MAINT CHECK AT WS 111.5 RIB BOTH I/B AND O/B FORMER FOOT BETWEEN REAR SPAR AND STA 11, WERE CRACKED THRU LOWER CENTER VERTICAL FASTENERS, CONFIRMED BY NDT. INSTALLED CLIP ON EACH PER DRAWING 9911606 AND SPM 6-70-1 PARA 4, PAGE 2 AND 3. INSTALLEDSDR AT0000458Skin · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CENTER TANK LOWER SKIN AT BS 617 RBL 16 - RBL 27 STRINGER 22 CORRODED. REMOVED CORROSION IAW REO-L00272.SDR AT0000443Coupler · missingE-PATH MISSING COUPLER AT ROW 21. INSTALLED COUPLER IAW BRUCE INDUSTRIES INC PEEPLES INSTALLATION MANUAL 33-21-27.SDR AT0000442Coupler · missingE-PATH LIGHTING, RED WIRE HAS NO END AT ROW 17. INSTALLED E-PATH LIGHTING COUPLE IAW 33-21-27.SDR AT0000453Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOORBEAM AT BS 160 RBL 7 CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPAIR AND FILLER IAW DC9 SRM 53-01 FIG 1 AND 53-11-03 FIG 13.SDR ABXA000447Fitting · corrodedAFT ACCESSORY AUXILIARY LANDING GEAR SUPPORT FITTING HAD AREA OF EXFOLIATION ON FORWARD RIGHT SIDE. REPLACED AFT ACCESSORY AUXILIARY LANDING GEAR SUPPORT IAW DC9 MM.SDR 0003479614Power Supply · inoperativeDURING LINE CHECK, FOUND TAIL CONE AREA AND CATWALK AREA EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY. OPERATIONAL CHECK NORMAL.SDR MWEA00832Hi Lok · looseMKE - LEFT WING LOWER SURFACE HAD 2 FASTENERS LEAKING FUEL AT STR 19 BETWEEN STA 214 - STA 240. REMOVED FASTENERS, REMOVED TO OVERSIZE AND FABRICATED REPAIR BUSHINGS. INSTALLED BUSINGS AND FASTENERS. (X)SDR ABXA000449Fitting · corrodedAFT ACCESSORY AUXILIARY LANDING GEAR SUPPORT FITTING HAD AREA OF EXFOLIATION LEVEL 1 CORROSION ON FORWARD LEFT SIDE. REPLACED LEFT AUXILIARY LANDING GEAR SUPPORT IAW DC9 SRM 51-30-2 & 51-30-5.SDR TWAA0014910Seat Track · corrodedDURING OP 15 MAINT CHECK, FOUND CORROSION ON NUMBER 3 CHAIR TRACK, STA 925 TO 965. REPLACED TRACK AT STA 927 TO 965 PER SRM 53-05, FIG 4D. NAS 6203 BOLTS USED, REPLACEMENT FOR NAS 1103 BOLT PER SRM 51-60-0.SDR AT0000455Floor Panel · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOOR PANEL NR 70A BEYOND REPAIR. FABRICATED NEW FLOOR PANEL.SDR 0003449615Light · inoperativeDURING LINE CHECK, FOUND FLOOR PROXIMITY EMERGENCY LIGHT INOPERATIVE IN CATWALK AREA. MAINTENANCE RELAMPED AS NEEDED.SDR MWEA001321Skin · damagedMKE - RIGHT WING TRAILING EDGE AT INBOARD EDGE OF INBOARD SPOILER SKIN IS TORN. REPAIRED PER BOEING STRUCTURAL REPAIR MANUAL 57-01, FIGURE 3 SHEET 2. (M)SDR MWEA00808Skin · crackedMKE - LEFT WING LOWER SURFACE SKIN JUST FORWARD OF INBOARD BUTT DOOR HAD .50 INCH CRACK. MAINTENANCE REMOVED AND REPLACED SKIN. (X)SDR MWEA00807Floor Panel · damagedMKE - CABIN FLOORBOARD B1 AT STA 256 HAD A HOLE IN IT. FABRICATED AND INSTALLED REPAIR DOUBLER. (X)SDR MWEA00806Frame · damagedMKE - AFT CARGO BAY FRAME HAD 5 EACH ELONGATED HOLES AT STA 897. LONGERON 30 - LONGERON 29 LEFT. FABRICATED AND INSTALLED REPAIR DOUBLER. (X)SDR MWEA00805Clip · crackedMKE - CRACK ON AFT PRESSURE BULKHEAD FORMER END CLIP, ON FORWARD SIDE OF AFT PRESSURE BULKHEAD, RIGHT SIDE FORMER 2-34.0, OUTBOARD ATTACH POINT. MAINTENANCE REMOVED AND REPLACED CLIP. (X)SDR MWEA00804Fitting · crackedMKE - RIGHT FLAP INBOARD ATTACH FITTING TO BUSS TRACK IS CRACKED, STA XCW 58.7. MAINTENANCE REMOVED AND REPLACED FITTING. (X)SDR TWAA0014909Skin · damagedDURING OP 15 MAINT CHECK, FOUND ON FUSELAGE, 7 RIVET HEADS STRESSED AND CRACKED AT STA 256, 10 TO 14 INCHES BELOW CUSP LINE ON LT SIDE. REMOVED CORROSION PER SPM 6-80-01. SEALED AND REPLACED FASTENERS PER DRAWING 5911410.SDR TWAA0014908Skin · damagedDURING OP 15 MAINT CHECK, FOUND ON FUSELAGE, 2 RIVET HEADS DIMPLED AND STRESSED AT STA 237, 8 INCHES BELOW CUSP LINE ON LT SIDE. REMOVED CORROSION PER SPM 6-80-01. SEALED AND REPLACED FASTENERS PER DRAWING 5911410.SDR AT0000403Light · inoperativeFOUND EMERGENCY PATH LIGHTING AT SEAT 18D WILL NOT ILLUMINATE. REPAIRED BROKEN WIRE AT SEAT 18D, EMERGENCY PATH LIGHTING IAW DC9 MM 33-00.SDR AT0000402Battery Pack · dischargedFOUND NR 1 ENGINE NACELLE EMERGENCY LIGHT NOT ILLUMINATED. REMOVED AND REPLACED ENGINE NACELLE LIGHT BATTERY PACK IAW DC9 MM 33-53.SDR MWEA00802Floor Support · chafedMKE - FLOORBOARD SUPPORT CHAFED BEYOND LIMITS AT STA 465 BETWEEN CENTER FLOORBEAM AND NR 2 SEAT TRACK. REMOVED AND REPLACED FLOORBOARD SUPPORT. (X)SDR MWEA00801Floor Panel · chafedMKE - FLOOR PANEL F7 SUPPORT CHANNEL CHAFED. REMOVED AND REPLACED FLOOR PANEL SUPPORT CHANNEL. (X)SDR MWEA00800Skin · dentedMKE - FUSELAGE SKIN DENT BELOW LONGERON 24R AT STA 218. FABRICATED AND INSTALLED REPAIR DOUBLER. (X)SDR MWEA00799Skin · dentedMKE - FUSELAGE SKIN IS DENTED AT STATION 136 LONGERON 21 LEFT. FABRICATED AND INSTALLED REPAIR DOUBLER. (X)SDR MWEA00798Skin · dentedMKE - FUSELAGE SKIN AT STA 218 ABOVE LONGERON 23 RIGHT HAD A DENT. FABRICATED AND INSTALLED A REPAIR DOUBLER. (X)SDR MWEA00796Frame · tool damageMKE - FUSELAGE FRAME 294 HAD 3 EACH DRILL STARTS ON FORWARD SURFACE AT LONGERON 6 RIGHT REAR RIVETS. FABRICATED AND INSTALLED FRAME REPAIR. (X)SDR MWEA00795Floorboard · crackedMKE - COCKPIT CENTER FLOORBOARD HAD CRACKED HAT CHANNEL AND PULLED RIVET HEADS ON AFT END. REMOVED AND REPLACED HAT CHANNEL. (X)SDR MWEA00794Structure · crackedMKE - LEFT SUBFLOOR HAD 2 CRACKS AT STA 960. FABRICATED AND INSTALLED REPAIR DOUBLER. (X)SDR MWEA00793Floor Support · crackedMKE - FLOORBOARD SUPPORT BRACKET HAD SMALL CRACK AND BARE METAL AT STA 935 BETWEEN NR 1 AND NR 2 SEAT TRACKS. REMOVED AND REPLACED FLOOR SUPPORT. (X)SDR MWEA00792Floorbeam · gougedMKE - CABIN FLOOR SUPPORT 'A' CHANNEL ON FLOORBEAM STA 639 BETWEEN SEAT TRACKS NR 1 AND NR 2 HAD GOUGES IN IT. REMOVED AND REPLACED 'A' CHANNEL. (X)SDR MWEA00791Seat Track · corrodedMKE - NR 4 SEAT TRACK IS CORRODED OUT OF LIMITS AT STA 218. REMOVED AND REPLACED SEAT TRACK. (X)SDR MWEA00790Skin · dentedMKE - FUSELAGE SKIN AT STA 148 AT LONGERON 23 RIGHT HAD A DENT. FABRICATED AND INSTALLED REPAIR DOUBLER. (X)SDR 0003509601Power Supply · inoperativeDURING LINE CHECK, FOUND EMERGENCY LIGHTS IN CATWALK INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY.SDR 0003459623Light · inoperativeDURING LINE CHECK, FOUND TAIL COMPARTMENT EMERGENCY WALK LIGHT INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY.SDR ABXA000446Floorbeam · corrodedSTATION 965 FLOORBEAM HAD CORROSION ON THE TOP FLANGE AT RIGHT BUTT LINE 30. REPAIRED FLOORBEAM IAW DC9 REA D953-38476.SDR ABXA000450Floorbeam · corrodedFLOORBEAM 965 UPPER CAP ANGLE HAD LEVEL 1 CORROSION AT RIGHT BUTT LINE 44.0. REPLACED ANGLE IAW DC9 SRM.SDR AT0000457Floor Panel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FORWARD ENTRY FLOOR PANEL NR 4692B CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLOOR PANEL IAW DC9 SRM 51-10-03, 51-10-04, 53-20 FIG 2E, AND 51-30-02.SDR AT0000456Floor Panel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOOR PANEL NR 82 CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPAIR.SDR AT0000454Floor Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND COCKPIT FLOOR SUPPORT AT BS 160 LBL 7 CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 53-01 FIG 1, 51-10-04, 51-10-03, 53-11-01 FIG 13, 51-30-02, AND 51-30-05.SDR AT0000452Floor Support · corrodedDURING A SCHEDULED INSPECTION , FOUND MAIN CABIN FLOOR SUPPORT AT BS 200 LBL 2 CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLOOR SUPPORT IAW DC9 SRM 53-11-01 FIG 13, 51-10-03, 51-10-11, AND 51-30-02.SDR AT0000451Floor Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND MAIN CABIN FLOORBEAM SUPPORT AT BS 160 - 218 CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLOOR SUPPORT IAW DC9 SRM 53-01 FIG 1, 51-10-03, 51-10-04, 51-30-05, 53-11-01 FIG 13, AND 51-30-02.SDR AT0000401Socket · dirtyFOUND RIGHT OVERWING EXIT EMERGENCY LIGHT AFT LAMP VERY DIM. CLEANED OVERWING EMERGENCY EXIT SOCKET IAW DC9 MM 20-50.SDR 0003299924Engine · failedAFTER TAKEOFF, THE LEFT ENGINE QUIT WITH SLIGHT VIBRATION NOTED. THE FLIGHT CREW PERFORMED THE RED BORDER CHECK LIST, RETURNED TO DTW AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE LEFT ENGINE. OPERATIONAL CHECK NORMAL.SDR TWAA0014201Power Supply · inoperativeTHE EGRESS LIGHTS WERE INOPERATIVE FROM ROW 16 TO 21. REPLACED THE POWER SUPPLY. CHECK-C 10-27-99 STL.SDR MWEA00786Floor Support · corrodedMKE - FLOORBOARD SUPPORT CORRODED AT BS 200 BETWEEN CENTER AND NR 3 SEAT TRACK. MTC FABRICATED NEW FLOORBOARD SUPPORT AND REINSTALLED. (X)SDR MWEA00785Floor Support · corrodedMKE - FLOORBOARD SUPPORT AT STA 200 BETWEEN NR 3 AND NR 4 SEAT TRACK CORRODED. MTC FABRICATED NEW FLOORBOARD SUPPORT AND REINSTALLED. (X)SDR MWEA00784Floor Support · corrodedMKE - FLOORBOARD SUPPORT CORRODED AT BS 200 FROM NR 4 SEAT TRACK OUTBOARD. MTC FABRICATED NEW FLOORBOARD SUPPORT AND REINSTALLED. (X)
Back to Douglas DC-9-32