Douglas DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20120714002Battery · dirtyRIGHT AND CENTER CEILING EMERGENCY LIGHTS BETWEEN AFT LAVATORIES INOPERATIVE. CLEANED BATTERIES FOR CENTER CEILING EMERGENCY LIGHTS BETWEEN AFT LAVATORIES. OPS CHECK NORMAL.SDR AALA20120714001Battery · dirtyCEILING EMERGENCY LIGHTS FROM ROWS 28 TO 30 INOPERATIVE. CLEANED BATTERIES FOR ROWS 28 TO 30 EMERGENCY LIGHTS. OPS CHECK NORMAL.SDR AALA20120713005Door Frame · crackedAFT CARGO DOOR AFT FRAME CRACKED AT NUMBER 5 BEAM. STOP DRILLED CRACK AND INSTALLED DOUBLER PER EA COMP-52-024887.SDR AALA20120713001Cusp Web · corrodedLEFT CUSP AT STATION 565 FORWARD OF T-ANGLE CORRODED. INSTALLED DOUBLER AT LEFT CUSP SHEET AT STATION 598 PER AARD 53-20-00-16.SDR 2012F00135Battery Pack · inoperativeFWD ENTRY AND L1 DOOR EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY BATTERY PACK IAW MM 33-53-00. OPS NORMAL.SDR 2012F00136Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK AT BS 219 INOPERATIVE. R & R EMERGENCY BATTERY PACK. OPS CHECKED NORMAL IAW AMM 33-53-00.SDR AALA20120712031Cusp Web · corrodedLEFT CUSP FROM STATIONS 511 TO 515 CORRODED. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20120712026Cusp Web · crackedAPPROXIMATELY 2 INCH CRACK IN RIGHT CUSP STATION. REPLACED CUSP SHEET FROM STATIONS 1266 TO 1309 PER AARD 51-00-05-1.SDR AALA20120712023Cusp Web · corrodedLEFT CUSP STATION 598 FORWARD OF T-ANGLE CORRODED. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20120712020Cusp Web · crackedCUSP CRACKED AT FORWARD LAVATORY TOILET BALL VALVE. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20120711012Track · corrodedCORROSION ON TIEDOWN TRACK RIGHT SIDE FROM STATIONS 1110 TO 1155. REMOVED AND REPLACED RIGHT TIE DOWN TRACK STATIONS 1110 TO 1155 PER AARD 51-00-05-1, SRM 51-30-05, SRM 51-30-01 AND BOEING DRAWING 5936663.SDR AALA20120711009Skin · dentedA 1 INCH DENT WITH HIGH METAL, 3 FEET AFT OF OVER PRESSURIZATION VALVES 3 FEET BELOW FLOOR LINE LEFT SIDE OF FUSELAGE. INSTALLED INTERNAL REPAIR DOUBLER, SHIMS AND FILLER PLUG PER SRM 53-04-02 FIGURE 2.SDR AALA20120711008Angle · crackedVERTICAL ANGLE CRACKED AT STATION 927, BELOW SEAT TRACK NUMBER 2. REMOVED AND REPLACED VERTICAL ANGLE PER AARD 51-00-05-1.SDR AALA20120711006Mount · corrodedG-1 GALLEY MOST INBOARD FLOOR MOUNT CORRODED. REPLACED G-1 GALLEY MOUNT PER AARD 51-00-05-1.SDR YYFA20120709001Engine · malfunctionedLEFT ENGINE DID NOT ACCELERATE. APPLIED POWER AT STATIC POSITION. NO RTO EGT526, N1 AND N2 AT IDLE.SDR AALA20120710014Skin · bentCABIN FORWARD ENTRY DOOR SKIN BENT AT LOWER AFT CORNER. STRAIGHTENED LOWER AFT SKIN AND INSTALLED DOUBLER PER AARD 52-10-00-2.SDR AALA20120710011Stiffener · crackedCENTER VERTICAL STIFFENER ABOVE VAULT DOOR CRACKED AT TOP END. REPLACED STIFFENER PER AARD 51-00-05-1.SDR Y2PA20120710038Power Supply · inoperativeWHILE PERFORMING AN "A" CHECK ON THE ACFT, DISCOVERED THE TAIL COMPARTMENT WALKWAY AND SLIDE EMERGENCY LIGHT INOPERATIVE. R & R THE R5-209 EMERGENCY POWER SUPPLY. SYSTEM OPS CHECKED GOOD IAW MM 33-50-0.SDR 2012F00131Engine · malfunctionedLEFT ENGINE DID NOT ACCELERATE. APPLIED POWER AT STATIC POSITION. NO RTO EGT 526, N1 AND N2 AT IDLE. POWER LEVERS MATCHED AT 1.68 EPR.SDR AALA20120713013Skin · damagedMULTIPLE HAIL DENTS ON THE RIGHT ELEVATOR. INSTALLED DOUBLER REPAIR AT 102 INCHES FROM I/B EDGE PER SRM 55-03-00 FIG 13A. MRT# 037758.SDR 2012FA0000465Battery Pack · inoperativeDURING A ROUTINE SERVICE CHECK, MX DISCOVERED THE EMERGENCY CABIN OVERHEAD CEILING LIGHTS IN ROWS 21L, 23L, 23R, 28L, 29L, AND 29R INOPERATIVE. MX R & R BATTERIES AT LOCATION 909R AND 1057, OPS CHECKED GOOD IAW AMM 33-53-00.SDR AALA20120709003Lens · missingEMERGENCY PROXIMITY LIGHT AT 26D MISSING LENS. REPLACE LENS FOR PROXIMITY LIGHT AT SEAT 26D. OPS CHECK NORMAL.SDR AALA20120709002Power Supply · inoperativeAFT OVERWING EXIT SIGN INOPERATIVE. REPLACED EMERGENCY LIGHT POWER SUPPLY B5-105. OPS CHECK NORMAL.SDR AALA20120709001Motor · failedTUL - INFLIGHT DFW-ORD. CREW REPORTED UNABLE TO PRESSURIZE CABIN. EMERGENCY DECLARED FLIGHT DIVERTED TUL LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED NUMBER 2 OUTFLOW MOTOR. SYSTEM GROUND CHECK NORMAL OPERATION.SDR AALA20120707003Angle · crackedSTATION 905 ABOVE CENTER FUEL TANK HAS VERTICAL ANGLE CRACKED JUST BELOW NUMBER 4 SEAT TRACK. INSTALLED SERVICEABLE VERTICAL ANGLE PER AARD 51-00-05-1.SDR AALA20120706008Cusp Web · corrodedRIGHT CUSP FROM STATIONS 522 TO 541 CORRODED. INSTALLED REPAIR DOUBLER PER AARD 53-20-00-16.SDR AALA20120706001Cusp Web · crackedCRACK IN LEFT CUSP AT LIGHTNING HOLE OUTBOARD OF SEAT TRACK NUMBER 1 AT STATION 412. INSTALLED DOUBLER LEFT CUSP AT STATION 412 PER AARD 53-20-00-16.SDR AALA20120713018Cusp Web · damagedRIGHT CUSP STATION 905 HAS DOUBLE DRILLED HOLE. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20120713017Cusp Web · damagedCUSP AT RIGHT STATION 886 HAS DAMAGED HOLE. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20120706004Light · inoperativeAFT ESCAPE PATH LIGHT AT SEAT 4E INOPERATIVE. REPLACED LAMP FOR ESCAPE PATH LIGHT AT SEAT 4E. OPS CHECK NORMAL.SDR AALA20120706003Battery Pack · not seatedTAIL COMPARTMENT EMERGENCY LIGHTS ABOVE CATWALK INOPERATIVE. RESEATED AND SECURED BATTERY PACK. OPS CHECK NORMAL.SDR AALA20120706002Battery Pack · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 23 TO 26 INOPERATIVE. RESEATED BATTERY PACK. OPS CHECK NORMAL.SDR AALA20120705013Cusp Web · crackedLEFT CUSP AT STATION 886, OUTBOARD AFT NUMBER 1 SEAT TRACK MOUNT BOLT HOLE IN CUSP IS CRACKED. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20120713015Membrane · corrodedCORROSION ON SUBFLOOR UNDER NUMBER 2 GALLEY TIE DOWN STATION 218. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR FX7A2012F00123Interphone · intermittentAFT F/A PHONE INTERMITTENT AND RAFFLES INSIDE.SDR YYFA20120703001Buss · failedLT AC BUSS FAILED TO POWER AFTER ENGINE START, FAILED INSTRUMENTS AND INDICATIONS ON CAPTAINS FMA, LT ENGINE PARAMETERS, AND PFD. AC CROSS TIE NOTED BUT BUT FAILED TO RESET. MX PERFORMED THE FOLLOWING: RESET AC CROSS TIE RELAY IAW AMM 71-00-00, CW AC CROSSSDR YYFA20120702001Indication Sys · malfunctionedLEFT EPR GAUGE FAILED TO INDICATE NORMAL TAKE OFF POWER SETTING DURING TAKEOFF. COMPLIED WITH EPR INDICATION SYS AND LEAK CHECKED IAW 77-11-01. NO DEFECTS NOTED. COMPLIED WITH NR 1 ENG RUN FOR EPR OPS CHECKS, ALL PARAMETERS NORMAL IAW AMM 71-00-00.SDR AALA20120703005Battery · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 28 TO 30. RESEATED EMERGENCY BATTERY AT ROW 28. OPS CHECK NORMAL.SDR AALA20120703004Battery · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 12 TO 16 INOPERATIVE. RESEATED EMERGENCY BATTERY AT ROW 15DEF. OPS CHECK NORMAL.SDR 2012F00122Relay · malfunctionedLEFT AC FAILED TO POWER AFTER ENGINE START, FAILED INSTRUMENTS AND INDICATIONS ON CAPTAIN FMA, LEFT ENGINE PARAMETERS AND PFD, AC CROSSTIE NOTED BUT FAILED TO RESET. MX PERFORMED THE FOLLOWING: RESET AC CROSSTIE RELAY IAW AMM 71-00-00, C/W AC CROSSTIE OPS CHESDR 2012F00121Relay · malfunctionedLEFT AC FAILED TO POWER AFTER ENGINE START, FAILED INSTRUMENTS AND INDICATIONS ON CAPTAIN FMA, LEFT ENGINE PARAMETERS AND PFD , AC CROSSTIE NOTED BUT FAILED TO RESET. MX PERFORMED THE FOLLOWING: RESET AC CROSSTIE RELAY IAW AMM 71-00-00, C/W AC CROSS TIE. OPSDR DU4R20120702001Frame · crackedDURING SCHEDULED INSPECTION, FOUND RT OVERWING FRAMES STA 886.0 FOUND CRACK APPROX .300 IN LENGTH. CRACK TIP OUTSIDE SHADOW OF FASTENER HOLE, CRACK FALLS UNDER CONDITION 3 OF THE SB MD80-53A01, PAGE 16.SDR AALA20120629012Engine · failedRAP - INFLIGHT PHX-ORD. CREW REPORTED LEFT ENGINE OIL QUANTITY LOSS AND HIGH OIL TEMPERATURE. CREW PERFORMED ENGINE SHUT DOWN (SINGLE ENGINE TIME 31 MINS). EMERGENCY DECLARED FLIGHT DIVERTED RAP LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLSDR YYFA20120627002Pa System · inoperativeFWD F/A PA INOPERATIVE: R & R CONNECTOR, REINSTALLED, FWD P/A HANDSET, OPS CHECKED GOOD IAW AMM 23-30-00.SDR YYFA2012F00120Connector · dirtyFWD F/A PA INOPERATIVE. REMOVED AND CLEANED CONNECTOR AND REINSTALLED FWD PA HANDSET. OPS CK GOOD IAW AMM 23-30-00.SDR YYFA20120627001Smoke Detector · false activationLT LAVATORY SMOKE DETECTOR ALARM SOUNDED IN FLIGHT. INSPECTION FOUND FALSE ALARM. INSPECTED LT LAV SMOKE DET AND FOUND NO DEFECTS. OPS CHECKED AND TESTED IAW CMM 26-10-02, PG 504. OPS CHECKED COULD NOT DUPLICATE FALSE ALARM.SDR YYFA2012F00124Smoke Detector · false indicationLEFT LAVATORY SMOKE DETECTOR ALARM SOUNDED IN FLT. INSPECTED AND FOUND TO BE A FALSE ALARM. INSPECTED LT LAVATORY SMOKE DETECTED AND FOUND NO DEFECTS. OPS CHECKED AND TESTED IAW CMM 26-10-02, PG 504. OPS CHECK COULD NOT DUPLICATE FALSE ALARM.SDR Y2PA20120624036Power Supply · inoperativeDURING MX, FOUND AFT RT OVERWING EXIT LIGHTS INOPERATIVE. R & R POWER SUPPLY. SYSTEM OPS CHECKED GOOD IAW 33-50-0.SDR Y2PA20120624035Power Supply · inoperativeDURING MX, FOUND FWD RIGHT OVERWING EXIT LIGHTS INOPERATIVE. R & R POWER SUPPLY. SYS OPS CHECKED GOOD IAW MM 33-50-0.SDR AALA20120624003Power Supply · defectiveSTL - INFLIGHT ORD-DFW. CREW REPORTED BURNING ODOR ASSOCIATED WITH ELECTRICAL COMPONENTS. FLIGHT ATTENDANTS TURNED OFF POWER TO POWER PORTS AND ODOR DISSIPATED THROUGHOUT CABIN. EMERGENCY DECLARED FLIGHT DIVERTED STL LANDED WITHOUT INCIDENT. REPLACED BAD P
Back to Douglas DC-9-83