SDR SWIA201231869Light · inoperativeEMERGENCY FLOOR LIGHT AT ROW 5 IS OUT. (FLT 5339) RELAMPED EMERGENCY LIGHT.SDR SWIA201231851Wire · brokenEMERGENCY EXIT SIGN ABOVE SEAT 9B DOES NOT ILLUMINATE. (FLT 5349) REPAIRED BROKEN WIRE WITH A SERVICEABLE SPLICE.SDR GLBA20120920121Bulb · burned outPILOT REPORTED THAT THE EMERGENCY EXIT LIGHT IN THE CEILING ABOVE ROW 6 WILL NOT ILLUMINATE. MX REPLACED THE BULB, OPS CHECKED GOOD.SDR SWIA201231839Light · unsecureEMERGENCY FLOOR LIGHTING AT GALLEY COMING APART. (FLT 6281) SECURED EMERGENCY FLOOR LEVEL LIGHTING STRIP AT GALLEY.SDR SWIA201231870Wire · damagedTWO RED FLOOR EMERGENCY LIGHTS AT ROW 9 FAIL TO ILLUMINATE. (FLT 5538) REPAIRED WIRE FOR FLOOR EMERGENCY EXIT IN REFERENCE TO EMB 120-WDM.SDR SWIA201231844Control Valve · defectiveFLIGHT ATTENDANT SMELLED A PACK BURNING IN CABIN DURING FLIGHT. ON THE GROUND FLIGHT DECK BECAME SMOKEY WITH PACKS ON. (FLT 6238) REPLACED TEMP CONTROL VALVE IN REFERENCE TO EMB 120 MM. P/N: 979990-1 S/N OFF: 2081SDR GLBA2012091800064Lamp · inoperativePILOT REPORTED THAT THE OVERHEAD EMERGENCY LIGHT ABOVE ROW 8 WILL NOT ILLUMINATE. LAMPED LIGHT, OPS CHECKED GOOD.SDR SWIA201231832Relay · failedCREW SMELLED HOT ELECTRICAL SMELL FROM FIRST OFFICER'S SIDE PANEL. NO SMOKE OBSERVED. (FLT 6233) REPLACED APU FEEDER PROTECTION RELAY IN REFERENCE TO EMB 120 MM.SDR SWIA201231825Wire · brokenFORWARD RED EMERGENCY LIGHT STRIP IS INOPERATIVE. (SERVICE) FOUND BROKEN WIRE AT FORWARD EMERGENCY LIGHT STRIP. REPLACED LIGHT SOCKET ASSEMBLY.SDR GLBA2012091700055Control Handle · faultyPILOT REPORTED THAT THEY HAD A FLAP CONTROL FAULT FOLLOWED BY A FLAP DISAGREE, EMER DECLARED, LANDED SAFELY. MX REPLACED THE FLAP CONTROL HANDLE, OPS CK GOOD.SDR SWIA201231776Fuse · failedFLOOR EMERGENCY STRIP IS INOPERATIVE. (FLT 5447) REPLACED EMERGENCY LIGHTING SYSTEM FUSE BY FORWARD ELBP IN REFERENCE TO AMM.SDR SWIA201231782Bolt · brokenGREEN HYDRAULIC SYSTEM FAILURE. (FLT 6444) FOUND BROKEN BOLTS AT LEFT AND PACK ENGINE PRESSURE BYPASS POP OUT INDICATOR. REPLACED O-RING ASSEMBLY AND (4) BOLT ASSEMBLIES AT POPOUT ASSEMBLY.SDR SWIA201231780Duct · blownON ROTATION DUCT LEAKAGE LIGHT ON LEFT SIDE CAME ON. (FLT 5367) FOUND BLOWN LEFT WRAP AROUND BLEED DUCT. REPLACED LEFT ENGINE WRAP AROUND BLEED DUCT IN REFERENCE TO AMM.SDR SWIA201231767Engine · faultyWITH LOW POWER SETTINGS AND BLEED PACKS IN AUTO/LOW, CABIN FILLS WITH SMOKE. (FLT 7802) REPLACED RIGHT ENGINE ASSEMBLY. P/N OFF: PW11813, S/N OFF: AP0019.SDR SWIA201231734Light · inoperativeLAST EMERGENCY LIGHT ON THE FLOOR STRIP IS OUT. (FLT 6294) RELAMPED EMERGENCY LIGHT.SDR SWIA201231749Unknown · odorWITH BLEED SOURCE SELECTED TO APU THERE IS A HOT SMELL COMING FROM THE LEFT PACK. (FLT 7782) COULD NOT DUPLICATE. RAN LEFT PACK OFF APU BLEEDS FOR 20 MINUTES WITH NO ODOR.SDR SWIA201231731Connector · failedWHEN TURNING ON EMERGENCY LIGHTS SWITCH IN THE COCKPIT ONLY FORWARD AND MIDDLE PORTION OF LIGHTS ILLUMINATE. (FLT 6368) REPLACED EMERGENCY BUS CONNECTOR 2 K0519 IN LEFT DC RELAY BOX.SDR SWIA201231748Bearing · failedRIGHT PROPELLER HUB LEAKING OIL. INSPECTED AND FOUND RIGHT PROPELLER NR 4 BEARING RACE FAILURE CAUSING DAMAGE TO RIGHT PROPELLER HUB. REPLACED RIGHT PROPELLER HUB AND ACTUATOR. P/N OFF: 782501-8 S/N OFF: 1785.SDR SWIA201231730Battery Pack · failedEMERGENCY LIGHTS ONLY STAY ON FOR ABOUT 1 SECOND WHEN TESTED. (FLT 5368) REPLACED FORWARD, MID, AND AFT ELBP'S IN REFERENCE TO AMM. P/N: D366-04-001 S/N OFF: 1241, S/N OFF: 176, S/N OFF: 1130.SDR SWIA201231722Wire · brokenEMERGENCY LIGHT ON FLOOR IN FRONT OF GALLEY ARE INOPERATIVE. (SERVICE) FOUND BROKEN CRIMP ON FRONT OF GALLEY FLOOR EMERGENCY LIGHT. RE-CRIMPED WIRE.SDR GLBA2012090501Bulb · inoperativeEMER PATHWAY ISLE LIGHT IS OUT IN ROW 6. REPLACED THE BULB, OPS CHECKED GOOD.SDR SWIA201231735Light · inoperativeFORWARD DOOR EMERGENCY LIGHT STRIP HAS ONE RED LIGHT INOPERATIVE. (SERVICE) RELAMPED EMERGENCY LIGHT.SDR SWIA201231926Door Frame · crackedFUSELAGE FRAME NR 13 CRACKED IN TWO PLACES BETWEEN 1ST AND 2ND DOOR FUSELAGE STOPS. (C-CHECK) REPAIRED IN REFERENCE TO EMB SRM.SDR SWIA201231705Unknown · odorWHEN REDUCING POWER LEVERS TO DESCEND, HAD AN ODOR OF OVERHEATING FROM RIGHT AIR CONDITIONING PACK. (FLT 7759) RAN RIGHT AIR CONDITIONING PACK IN ALL MODES WITH APU AND RIGHT ENG RUNNING, NO DISCREPANCIES NOTED.SDR SWIA201231725Hydraulic Line · chafedLOSS OF NR 2 HYDRAULIC FLUID. FLUID LEVEL DROPPED TO 0. (FLT 5397) ENGINE DRIVEN HYDRAULIC PUMP PRESSURE LINE CHAFED. REPAIRED IN REFERENCE TO MM.SDR GLBA2012083000041Window · crackedCOPILOT'S SIDE VIEW WINDOW CRACKED APPROX 8 IN FROM THE BOTTOM FORWARD EDGE. CRACK IS APPROX 1 IN LONG. MX REPLACED THE F/O'S SIDE VIEW WINDOW IAW 56-11-02, AND 56-11-01, OPS CHECKED GOOD.SDR SWIA201231684Relay · failedAN UNUSUALLY HIGH LOAD ON VOLTMETER, APU GENERATOR SIDE, AND RECEIVED A SMOKE SMELL IN THE COCKPIT. THE FIRST OFFICER'S SIDE PANEL WAS HOT TO TOUCH. (FLT 5447) REPLACED APU FEEDER PROTECTION RELAY IN RIGHT SIDE CONSOLE.SDR SWIA201231927Spar · crackedLEFT WING LOWER SPAR CRACKED BETWEEN RIBS 16 AND 18. (C-CHECK) REPAIRED IN REFERENCE TO EMB SRM.SDR SWIA201231640Rccb · odorLEFT PACK SMELLS BURNT. (FLT 5380) REPLACED RCCB FOR LEFT GROUND COOLING FAN IN REFERENCE TO AMM. P/N SM600BA50N1SDR SWIA201231622Cowl Flap · crackedLEFT NACELLE FLAP CRACKED. (A-INSPECTION) REPLACED LEFT NACELLE FLAP IN REFERENCE TO EMB120 AMM.SDR SWIA201231632Sign · missingEMERGENCY SIGN AT 6A MISSING. (FLT 6283) REPLACED EMERGENCY EXIT SIGN AT 6A IN REFERENCE TO AMM.SDR SWIA201231595Light · inoperativeOVERHEAD EMERGENCY LIGHT IS OUT NEXT TO MAIN CABIN DOOR COURTESY LIGHTS. (FLT 5339) RELAMPED EMERGENCY LIGHT.SDR SWIA201231625Door · lack of lubeMAIN CABIN DOOR IS HARD TO OPEN AND CLOSE. (FLT 6301) LUBED MAIN CABIN DOOR IN REFERENCE TO MM.SDR SWIA201231799Stringer · corrodedSTRINGER 18L BETWEEN FRAME 13 AND 14 HAS CORROSION. (C-CHECK) REPLACED FORWARD STRINGER SPLICE IN REFERENCE TO SRM.SDR SWIA201231789Profile · crackedLEFT INBOARD PROFILE J AND PROFILE SPLICE SECTION IS CRACKED ON RIGHT NACELLE. (C-CHECK) REPLACED PROFILE J AND SPLICE SECTION IN REFERENCE TO EMB 120 SRM AND INSERTED NEW SKIN SECTION AT LEFT NACELLE INBOARD IN REFERENCE TO ETD.SDR SWIA201231588Relay · failedTRIPLE CHIME AUTO FEATHER WARNING CONTINUOUS WITH SWITCH IN THE ON POSITION. (FLT 5516) REPLACED RELAYS K0039 AND K0161.SDR SWIA201231569Clamp · looseLEFT PACK OVERHEATING SMELL ON DESCENT. (FLT 5437) TIGHTENED A LOOSE CLAMP FOR LEFT PACK TEMPERATURE INLET CONTROL VALVE.SDR SWIA201231606Cam Lock · out of adjustMAIN CABIN DOOR HARD TO OPEN. (FLT 5386) ADJUSTED OVER CENTER CAMLOCKS IN REFERENCE TO MM.SDR GN0A20120817001Unknown · malfunctionedCDC TO GCN; AT APPROX 80 KTS THE AC EXPERIENCED AN UNCOMMAND SHARP TURN TO THE LT. POWER LEVERS WERE PLACED AT IDLE WHILE APPLYING FULL RT RUDDER HAD NO EFFECT ON DIRECTIONAL CONTROL OF THE AC. THE AC WAS 90° TO THE RUNWAY AS THE AC WAS SLIDING SIDEWAYS AT ASDR SWIA201231611Actuator · failedDURING LANDING GEAR RETRACTION, LEFT MAIN RED A AND B LIGHTS REMAINED ILLUMINATED. (FLT 5387) REPLACED LEFT MLG ACTUATING CYLINDER IN REFERENCE TO MM. PN OFF 19595-000-07 SN OFF B-24SDR SWIA201231556Fuse · not seatedFOUR WHITE AND ONE RED LIGHT OUT IN FLOOR EMERGENCY LIGHTING. (FLT 5367) RE-SEATED INTERIOR EMERGENCY LIGHT FUSE F0032 AT FRAME 24 IN REFERENCE TO AMM.SDR SWIA201231535Fuse · blownRIGHT OUTBOARD AFT EMERGENCY LIGHT IS OUT. (SERVICE) REPLACED A BLOWN FUSE IN REFERENCE TO MM. FUSE PN: F02A250V1ASDR SWIA201231560Light · inoperativeFLOOR EMERGENCY LIGHT AT 5A IS INOPERATIVE. (SERVICE) REPLACED LIGHT FIXTURE FOR EMERGENCY LIGHT AT ROW 5 IN REFERENCE TO EMB 120 MM.SDR SWIA201231658Frame · crackedFUSELAGE FRAME 13 HAS TWO CRACKS AT UPPER DV WINDOW SEAL HEIGHT. (C-CHECK) REPAIRED FUSELAGE FRAME 13 UPPER DV WINDOW SEAL HEIGHT IN REFERENCE TO EMB ETD AND EMB SRM.SDR SWIA201231657Floor Support · corrodedCABIN FLOOR SUPPORT T JUST AFT OF PASSENGER DOOR CUTOUT HAS CORROSION. (C-CHECK) REPLACED CABIN FLOOR SUPPORT T JUST AFT OF PASSENGER DOOR CUTOUT IN REFERENCE TO SRM.SDR SWIA201231523Cover · out of positionMAIN CABIN DOOR VERY HARD TO OPERATE FOR FLIGHT ATTENDANT. (FLT 5368) REPOSTIONED MAIN CABIN DOOR FORWARD HINGE ARM FLOOR COVER ASSEMBLY.SDR SWIA201231649Floor Support · corrodedPASSENGER DOOR ENTRY WAY LEFT SIDE OMEGA BEAM AT FRAME 14 HAS CORROSION. (C-CHECK) REPAIRED PER SRM.SDR SWIA201231536Light · inoperativeRED FLOOR EMERGENCY LIGHT AT THE FORWARD DOOR IS OUT. (FL T5574) RELAMPED EMERGENCY LIGHT.SDR SWIA201231522Apu · faultySTRONG CHEMICAL SMELL IN COCKPIT AND CABIN WHEN USING APU BLEED AIR. (FLT 6347) REPLACED APU ASSEMBLY IN REFERENCE TO EMB 120 AMM. P/N: 3800376-2 S/N OFF: P-443SDR SWIA201231521Unknown · smokeSMOKE SMELL AND SMOKE IN CABIN AND COCKPIT SETTING OFF SMOKE ALARM IN LAV. SMOKE COMING OUT FROM LEFT PACK OUTSIDE AIRCRAFT. (FLT 5839) INSPECTED LEFT AND RIGHT PACK ACM'S, GROUND COOLING FAN RCCB'S, WITH NO OIL CONTAMINATION OR DEFECTS NOTED. NO VISUAL SM
Back to Embraer EMB-120ER