Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA202002031002Wire · brokenNUMBER 7 EMERGENCY LIGHT, WIRE BROKEN.-C/A-REMOVED AND REPLACED NUMBER 7 EMERGENCY LIGHT IAW EMB 145 AMM 33-50-12. OPS CHECK GOOD.SDR SIMA202002031004Skin · gougedFUSELAGE SKIN IS GOUGED JUST BELOW PANEL 113EL AT FRAMES 6-7 BETWEEN STRINGERS 13L-15L-C/A-ACCOMPLISHED PERMANENT REPAIR ON FUSELAGE SKIN GOUGE JUST BELOW PANEL 113EL AT FRAMES 6-7 BETWEEN STRINGERS 13L-15L IAW ERS-EM-53MR-4019SDR HNAA2020020300040Warning Message · false activationFUEL 2 LOW LEVEL LIGHT DISPLAYED ON EICAS DURING TAKEOFF ROLL. ABORTED TAKEOFF. R&R FCU IAW AMM 28-41-01. OPS CHECK GOOD OK FOR SERVICE. CLEAR MEL 28-12 MEL FUEL1 OR 2 LO LEVEL MESSAGES CREW REPORTED AFTER ABORTED T/O MESSAGE EXTINGUISHED AND DID NOT COME BACKSDR HNAA2020020300038Warning Message · false activationLANDING GEAR LEVER DISAGREE MESSAGE DISPLAYED. PERFORMED GEAR SWING NO DEFECTS NOTED OK FOR SERVICE.SDR HNAA2020020300036Gasket · brokenGASKET ON GROUND CONNECTION VALVE DOOR IS BROKEN. REMOVED AND REPLACED GROUND CONNECTION DOOR RUBBER SEAL RING IN REFERENCE TO AMM 21-22-04-000/400-802A (P/N ON SEAL 120-15661-001 P/N OFF SEAL 120-15661-001)SDR HNAA2020020300035Outflow Valve · malfunctionedCABIN DEPRESSURIZED DURING DECENT AT FL 230 CABIN ALTITUDE REACH 12,100. UNCOMMANDED. PRESS CONTROL AUTO MANUAL. FOUND LOWER DOOR SEAL OF BAG BAY DOOR MISSING. INSTALLED BAG BAY DOOR SEAL IN REF TO AMM 52-30-02-400-801-A. OPS AND LEAK CHECK GOOD. CLEAR MEL. CSDR HNAA2020020310034Proximity Switch · malfunctionedLANDING GEAR LEVER DISAGREE MESSAGE AFTER GEAR RETRACTION. LANDING GEAR AMBER INDICATION. CYCLED LANDING GEAR PER QRH MESSAGE CLEARED. FOLLOWED FIM 32-32-00-810-803-A/ 32-63-00-810-804-A. NO DEFECTS. INSP HARNESSES AND WIRING. NO DEFECTS. CW LG PROX SWITCH TESSDR HNAA2020020310033Fuse · leakingVERFIED WITH CREW ENGINE WAS RUN FOR AT LEAST 15 MINUTES BUT LESS THAN 1 HOUR AFTER FLUID LOSS. FOUND L/H INB HYDE FUSE LEAKING. R+R L.H HYD FUSE IAW AMM 32-41-07. OPS AND LEAK CHECK GOOD. OK FOR SERVICE. REF. SEQ 1 THIS LOGPAGE HYD WENT TO ZERO ON RUNWAY. REMSDR HNAA2020020100032Unknown · odorSTRONG FUMY SMELL IN FLT DECK DURING ALL PHASES OF FLIGHT.MORE NOTICEABLE ON GROUND....FIX:PERFORMED HIGH POWER ENGINE RUNS WITH CREW. COULD NOT DUPLICATE ANY SMELLS WHILE ON APU,ENGINES AND WITH BOTH PACKS ON. A/C OK FOR SERVICE AT THIS TIMESDR SIMA2020021830006Frame · crackedIN COCKPIT ZONE 225 (TOP L.H SIDE ABOVE PILOT HEAD), ONE FRAME IS CRACKED-C/A-OVERHEADCIRCUIT BREAKER PANEL REMOVED FOR SHEET METAL ACCESS IN COCKPIT ZONE 225 (TOP L/H SIDE ABOVE PILOT HEAD) ONE FRAME REPLACED IAW SRM 51-40-02. OVERHEAD CIRCUIT BREAKER PANEL RSDR RAIA2020020400002Skin · crackedCAPT TOP EXTIRIOR LATERAL POST SKIN IS CRACKED...(MAJOR REPAIR) REPAIRED PER ETD2020-145-002977 AND EO-EMB145-53-070-OSDR SIMA202002030005Crossbeam · corrodedCENTER OMEGA BEAM CORRODED AT CROSS BEAM FRAME 49-C/A-ACCOMPLISHED REPAIR OF CENTER OMEGA BEAM CROSS BEAM FRAME 49 IAW EMB 145 SRM 53-00-10 FIG 203 AND ERS-EM-5300-4002 FOR USE OF ALTERNATE FASTENERSSDR SIMA202002030004Floorbeam · corrodedLH OMEGA BEAM IS CORRODED AT FRAME 29-C/A-ACCOMPLISHED REPAIR TO LH OMEGA BEAM CORROSION AT FRAME 29 IAW ERS-EM-53MR-4020 PT. A REV: ORIGINALSDR HNAA2020020300037Fan · inoperativeGASPER FAN INOP (CREW PULLED AND COLLARED CB F25) GASPER FAN. RESET GASPER FAN C/B F25 AND OPERATED GASPER FAN FOR AN EXTENDED PERIOD OF TIME OVER NIGHT. NO DEFECTS NOTED AT THIS TIME. OPS CHECK GOOD. OK FOR SERVICE. CLEAR MEL.SDR SIMA202001310003Cradle · brokenFWD ATTENDANT EMERGENCY FLASHLIGHT HOLDER BROKEN-C/A-REMOVED AND REPLACED FLASHLIGHT ASSY IAW EMB 145 AMM 33-50-16. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.SDR ASOA2020013104001Battery Pack · dischargedIAH FLIGHT 4385, THE CREW RPORTED THAT THE FLOOR EMERGENCY LIGHTS BETWEEN SEATS 8 AND 18 WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER THREE EMERGENCY LIGHT BATTERY PACK, OPERATIONALLY TESTED WITH NO DEFECTS NOTED AND THE AIRCRAFT WAS APPROVED SDR SIMA20200130002Beam · corrodedLH OMEGA BEAM IS CORRODED AT FRAME 29-C/A-ACCOMPLISHED REPAIR TO LH OMEGA BEAM CORROSION AT FRAME 29 IAW ERS-EM-53MR-4020 PT. A REV: ORIGINAL.SDR SIMA20200130001Beam · corrodedCENTER OMEGA BEAM IS CORRODED AT FRAME 29-C/A-ACCOMPLISHED REPAIR TO CENTER OMEGA BEAM CORROSION AT FRAME 29 IAW ERS-EM-53MR-4017 PT. A REV: ORIGINALSDR HNAA2020013100031Solenoid Valve · malfunctionedDURING GEAR RETRACTION NLG CAME UP WITH AN IMPACT NOISE,PAUSED THEN REPEATED. DOORS NEVER DID SHUT....FIX:R&RD NLG DOOR SOLENOID VALVE IAW EMB AMM 32-33-02 OPS/LEAK TEST SATISFACORY. OK FOR SERVICESDR HNAA2020013100030Electronic Unit · malfunctionedDURING GEAR RETRACTION, NLG CAME UP WITH A LOUD IMPACT NOISE,PAUSED THEN REPEATED,DRS NEVER DID SHUT....FIX:R&RD LG ELECTRONIC UNIT IAW AMM 32-32-01. OPS TEST/GEAR SWING SATISFACORY IN HANGER.REQ EVALUATION FLT...EVALUATION FLT SATISFACORYSDR SIMA2020013029001Lamp · inoperativeDURING PS-1 CHECK, FOUND BOTH OVER THE WING EMERGENCY LIGHT INOP.-C/A-FOUND OVERWING EMERGENCY LIGHTS INOP. RAR LH AND RH EMERGENCY LIGHT LAMPS IAW EMB 145 AMM 33-50-07. DID NOT FIX. RAR EMERGENCY LIGHTS BATTERY AND CHARGER IAW EMB 145 AMM 33-50-07.DID NOT FISDR HNAA2021011400012Nut Plate · missingPROTRACTOR NUTPLATE MISSING ON TRAILING EDGE ON RUDDER LT SIDE. PROTRACTOR NUTPLATE MISSING ON TRAILING EDGE ON RUDDER LT SIDE. PERFORMED CUTOUT OF DAMAGE AREA. FABRICATED AND PREPPED REPAIR DOUBLER AND INSTALLED. NUTPLATE INSTALLED, IAW EO1-55-20-0446, DMSDR SIMA202001298002Charger · inoperativeLH FWD OVER WING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH FWD OVER WING EMERGENCY LIGHT LAMP IN REFERANCE WITH 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FIX. REMOVED AND REPLACED EMERGENCY LIGHT ASSEMBLY IAW 33-50-10-000-801-A AND 33-50-10-400-801-SDR SIMA202001298003Skin · dentedDURING MBV INSPEECTION, QC FOUND A DENT BETWEEN FRAMES 4-5, STRINGERS 11R-14R-C/A-REPAIRED DENT BETWEEN FRAMES 4-5 AND STRINGERS 11R-14R IAW ERS-EM-53MR- 4022.SDR ASOA202001287015Wire Harness · damagedTYS A/C ONCE AIRBORNE THE AIR-GROUND FAIL AND CREW RETURN TO BASE. MAINTENANCE REMOVED AND REPLACED THE NLG WOW PROXY SWITCH HARNESS IAW EMB 145AMM 20-10-01 AND OPS CHECK GOOD IAW EMB 145 AMM 32-30-00. A/C RELEASED TO SERVICE.SDR SIMA202001297005Rib · crackedLH WING RIB 21 FOUND CRACKED INSIDE PANEL 551CB-C/A-ACCOMPLISHED DOUBLER REPAIR OF LH WING RIB 21 IAW EMB 145 SRM 57-20-07 ITEM 4.SDR SIMA202001297006Skin · damagedTHREE SHARP PROTRUSIONS WERE FOUND IN THE FUSELAGE SKIN BETWEEN FRAMES 27-28 AND STRINGERS 18L-19L-C/A-FORWARD PROTRUSION FOUND TO BE OUT OF LIMITS IAW EMB 145 SRM 53-22-10. ACCOMPLISHED SMALL SKIN DOUBLER AND FILLER REPAIR IAW EMB 145 SRM 53-22-01. CENTER PSDR RAIA2020012870001Unknown · odorAPU FIRE INDICATION AND SMELL OF SMOKE IN CABIN AND COCKPIT---INSP APU AREA. NO SIGNS OF FIRE OR FUEL LEAKS. PERFORMEDAPU START UP. ISNP AGAIN NO DEFECTS NOTED. ADDITIONAL MX-- PERFORMED OPS CHECKS OF PACKS WITH AND WITHOUT ENG RUNNING, NO SIGNS OF SMOKE IN CASDR SIMA202001276001Frame · crackedDURING HMBV INSPECTION, QA FOUND FRAME 66 IS CRACKED AT STRINGER 16R. -C/A-REMOVED AND REPLACED FRAME 66 IAW EMB 145 SRM 51-40-02.SDR SIMA202001276004Profile · corrodedDURING MBV INSPECTION, QC FOUND CORROSION ON THE PAX DOOR LOWER NUT PLATE HOLE.-C/A-REPAIRED CORROSION ON PAX DOOR LOWER NUT PLATE HOLE IAW EMB 145 SRM 52-10-02 AND ETN-EM-52-041 STEP 2. (REPAIR MATERIAL: DOUBLER 2024T3, 0.040")SDR HNAA2020012700029Probe · failedON T/O TAT1 INOP W/ NO CONFIG MSG. C/W FIM 30-33-00-810-801A. MSG CLEARED AND D/N RETURN. TAT 1 INOP ON T/O ASSOCIATED W/ NO CONFIG WARNING. PERFORMED FIM TASK 30-33-00-810-801A. R&R RELAYS K0495,K0534,K0325,K0059. R&R TAT CURRENT SENSOR IAW 30-33-01 NO FIX.SDR SIMA202001285005Wire · brokenMEL 25-53 AUTH #010760-C ORIG LG PG 4452721 ITEM #2 FWD FA FLASHLIGHT NOT CHARGING-C/A-T/S AND FOUND BROKEN WIRE IN FLASHLIGHT HARNESS. REPAIRED WIRE IAW SWPM 20-21-00 OPC GOOD IAW EMB AMM 33-51-01 MEL RESTOREDSDR SIMA202001275003Switch · brokenFOUND EMERGENCY LIGHT TOGGLE SWITCH BROKEN.-C/A-REMOVED AND REPLACED EMERGENCY LIGHTNING PANEL IAW EMB 145 AMM 20-13-00 PERFORMED OPS CHECK REF EMB 145 AMM 33-50-00 AND 33-11-00 OPS CHECK GOOD A/C OK FOR SERVICESDR SIMA202001275002Brake · lack of lubePARKING BRAKE HARD TO SET.-C/A-CLEANED AND LUBRICATED PARKING BRAKE IAW EMB 145MM 32-44-10. OPS CK GOOD.SDR SIMA202001275004Floor Support · corrodedDURING MBV INSPECTION, QC FOUND THE GALLEY LH FLOOR BEAM CORRODED AT CARBON CROSS MEMBER AT FR 20.-C/A-REPAIRED GALLEY LH FLOOR BEAM AT CARBON CROSS MEMBER AT FR 20 IAW EMB 145 SRM 53-00-10RE ITEM 2. (REPAIR MATERIALS: EXTERNAL ANGLE 2024T3 0.050", FILLER 2024SDR SIMA202001274002Lamp · inoperativeOVER L/H WING EMERGENCY LIGHT INOP-C/A-RELAMPED OVER L/H WING EMERGENCY LIGHT IAW AMM 33-50-10 OPS CHECK GOODSDR SIMA202001273003Channel · corrodedDURING MBV INSPECTION, QC FOUND THE SERVICE DOOR CENTER SILL CORRODED AT PREVIOUS BLENDED AREAS.-C/A-REMOVED AND REPLACED SERVICE DOOR CENTER SILL IAW EMB 145 SRM 51-40-02.SDR SIMA202001243001Control Module · failedBURNING WIRE SMELL FROM OVERHEAD FLUORESCENT LIGHTING OVER SEAT 1A-C/A-REMOVED AND REPLACED LIGHTING CONTROL MODULE IAW AMM 33-21-01.OPS CHK GOOD.SDR SIMA202001272006Web · gougedDURING MBV INSPECTION, QC FOUND 2 PREVIOUS REPAIR DOUBLERS ON CARGO DOOR INNER SKIN WEB WITH GOUGES-C/A-REMOVED AND REPLACED 2 PREVIOUS REPAIR DOUBLERS ON CARGO DOOR INNER SKIN WEB IAW EMB 145 SRM 52-30-01-RE ITEM #12. (REPAIR MATERIAL: DOUBLER 2024T3 0.050)SDR SIMA202001272005Skin · crackedDURING MBV INSPECTION, QC FOUND THE CARGO DOOR HANDLE CUTOUT CRACKED AT AFT UPPER END.-C/A-CUT OUT DAMAGE AND INSTALLED FILLER AND DOUBLER TO CARGO DOOR HANDLE CUTOUT IAW ERS-EM-52MR-1052. (REPAIR MATERIAL: 2024-T3, 0.050)SDR SIMA202001272004Profile · corrodedDURING MBV INSPECTION, QC FOUND THE CARGO DOOR LOWER PROFILE NUT PLATE HOLES CORRODED.-C/A-REMOVED AND REPLACED CARGO DOOR LOWER PROFILE IAW EMB 145 SRM 51-40-02.SDR SIMA202001272007Beam · crackedDURING MBV INSPECTION, QC FOUND THE CARGO DOOR INNER BEAM ON VB4 BETWEEN HB3 AND HB4 CRACKED.-C/A-REMOVED AND REPLACED CARGO DOOR INNER BEAM ON VB4 BETWEEN HB3 AND HB4 IAW EMB 145 SRM 51-40-02 AND ERS-EM-5200-1051. (P/N INSTALLED: 145-25939-601)SDR HNAA2020012400028Unknown · odorFUMES OF BURNING RUBBER IN CABIN AND COCKPIT....FIX: MEL,D #2 PACKSDR SIMA202001232001Warning Message · false indicationBLD 1 LEAK IN FLIGHT-C/A-TROUBLESHOT PER FIM TASK 36-20-00-810-801-A & PERFORMED OPC OF THE AIR BLEED SYSTEM PER AMM 36-00-00-700-803. ALL CHECKS GOOD. CND FAULT AT THIS TIME. A/C HISTORY SHOWS NO CURRENT/RECENT FAULT. A/C OK FOR CONTINUED SERVICE.SDR RAIA2020012910003Mount · cracked# 1 ENGINE FWD YOKE MOUNT LOWER FWD LINKAGE FITTING HAS CRACK AT FWD RADIUS- R&R #1 ENGINE FWD YOKE MOUNT LOWER FWD LINKAGE FITTING.SDR RAIA2020012410002Floor Support · corrodedMAIN CABIN CENTER OMEGA BEAM GUSSET HAS CORROSION FROM FRAME 23 THRU 29- REMOVED RH FLOOR TRACK FRAME 23-30 TO FOM. R/R MAIN CABIN CENTER OMEGA BEAM GUSSET FROM FR 23-29. STARTED INSTALLATION OF SEAT FLOOR TRACK. FINISHED INSTALLING SEAT TRACK.SDR SIMA202001231006Doubler · damagedDAMAGE ON NOSE WHEEL WELL FOUND TO BE OUT OF LIMITS PER EMBREAER "TRANSFERRED TO NRWC 663-ABI-04309"-C/A-FOUND DOUBLER ON RH SIDE OF NLG WHEEL WELL DAMAGED. REMOVED AND REPLACED DOUBLER IAW EMB 145 SRM 51-40-02, 51-20-03SDR SIMA202001221004Connector · dirtyMAIN DOOR EMERGENCY LIGHT INOP"TRANSFERRED TO NRWC 616-ORD-03398"-C/A-DEFERRED PER MEL 33-29. CLEANED MAIN DOOR EMERGENCY LIGHT ASSY ELECTRICAL CONNECTIONS IAW SWPM 20-50-00. OPS CHECK GOOD IAW EMB AMM 33-50-00. MEL RESTORED.SDR HNAA2020012200027Control Unit · smokeDURING CLIMB OUT CREW NOTICED SMELL, THEN DURING CRUISE SMELL REMAINED WITH SMOKE COMING FROM GLARE SHIELD AREA.....FIX: R&RD FLIGHT GC IAW EMB 145 AMM 22-11-01,OPS CHECK GOOD AT THIS TIME,OK FOR SERVICE. NOTE: CREW DONNED 02 MASKS EMERGENCY DESCENT. CONTINUESDR SIMA202001221005Static Inverter · failedMECH. LANDED SAFELY NO EMERGENCY DECLARED. 115 VAC BUS OFF,GPWS INOP,WINDSHEAR INOP,TERR INOP ENROUTE FL320-C/A-RAR AC STATIC INVERTER IAW E 145 AMM 24-20-01.OPS CHECK GOOD IAW AMM 24-20-00.
Back to Embraer EMB-145LR