Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20190905004Light · inoperativeRT AFT EXTERIOR EMERGENCY LIGHT BAD. C/A-R&R RT AFT EXTERIOR EMERGENCY LIGHT IAW AMM 33-50-10. OPS CHECK GOOD.SDR SIMA20190905006Handle · unsecureFAA REPORT EMERG EXIT DOOR HANDLE AT ROW 12A FELL OFF. C/A-REINSTALL EMERG EXIT DOOR HANDLE AT ROW 12A AS REQURIED.SDR HNAA2019090600251Warning System · false activationUPON T/O ROLL, A BLEED CAUTION LIGHT APPEARED FOLLOWED BY BLD WARNING LIGHT. T/O ABORTED. NO CMC RELATED MESAGES FOUND ON MFD DOWNLOAD. FIX: PERFORMED AIR BLEED SYS OPS CHECK/TEST IAW AMM 36-00-00-700-803-A. OPC CHECK GOOD. NO MESSAGES FOUND. OK FOR SERVICE ATSDR HNAA2019090600250Battery · dischargedEMERGENCY LIGHTS OVERWING ON LT AND RT SIDES AND EMERGENCY LIGHTS ON FLOOR STRIPS FROM SEATS 12A BACK TO 18A WILL NOT TURN ON. FIX: REMOVED AND REPLACED #400 BATTERY ASSY IAW AMM 33-50-04-04. OPS CHECK GOOD.SDR HNAA2019090600249Battery · dischargedAFT F/A FLASHLIGHT IS NOT WORKING. FIX: REPLACED OLD BATTERY WITH NEW ONE.SDR SIMA2019100192004Bracket · damagedCRASH AXE BRACKET BEHIND FO SEAT HAS BUTTERFLY. NOT RECEIVING THREAD WORN OUT. UNABLE TO SECURE. SECURED CRASH AXE 1/4 TURN CAM-LOCK IAW STANDARD MAINT PRACTICE. CHECK GOODSDR SIMA20190902003Acm · failedPACK 1 OVERLOAD PACK 1 OVERHEAT HAPPENED ON GROUND THERE WAS A BURNING SMELL THAT WAS THERE FOR A SHORT TIME AT 2K FEET NO MESSAGES APPEARED. "TRANSFERRED TO NRWC 615-ORD-03102". C/A-FOUND LT ACM DAMAGE, REMOVED AND REPLACED OF LT ACM, OPS CHECK GOOD, AND ODORSDR SIMA20190902001Door · lack of lubeFA REPORTS MAIN CABIN DOOR STICKING AND DIFFICULT TO OPEN. C/A-LUBED THE MAIN CABIN DOOR ADJUSTMENT AND TEST OK. REF AMM 52-10-01.SDR SIMA20190902002Light · inoperativeEMERG ASILE LIGHT FROM 3A - 7A INOP. C/A-DEFERRED AS PER MEL 33-30. RESECURED LOOSE ELECTRICAL CONNECTION AT LIGHT STRIPS OPS CHECK GOOD. MEL 33-30 RESTORED.SDR HNAA2019090300248Light · inoperativeNDIS 642 33-51 0007420 01SEP19 RIC CLOSE EMERGENCY FLOOR LIGHT @ ROW 1/GALLEY INOP. FACT 01SEP19 10:18 RIC R&R EMERGENCY FLOOR LIGHT AT ROW 1/GALLEY IN REF TO AMM 33-50-12-000/400-A OPS CHECK GOOD OK FOR SERVICE P/N ON 1013196 EME FLOOR LIGHT P/N OSDR HNAA2019090300247Sign · inoperativeNDIS 642 33-31 0007470 01SEP19 RIC CLOSE EMERGENCY EXIT SIGN ABOVE SERVICE DOOR INOP FACT 01SEP19 10:25 RIC R&R EMERGENCY EXIT SIGN ABOVE SERVICE DOOR IAW AMM 33-50-14-000/400-801-A R&R #200 EMER LIGHT DC/AC INVERTER IAW AMM 33-50-11-000/400-801-A SDR HNAA2019090300246Wire Harness · defectivePDIS 651 36-21 1903252 01SEP19 BOS CLOSE HIGH STAGE VALVE 1 FAIL MESSAGE DURING T/O ROLL AT ABOUT 80 KTS. FACT 02SEP19 05:51 MDT
R/R HARNESS ASSY TO HIGH STAGE VALVE IN REF TO AMM 71-51-01-400-801. OPS CHECK ENG 1 HSV IN REF TO AMM 36-11-02-700-80SDR SIMA20190901001Inverter · inoperativeDURING PS-1 CHECK FOUND FWD EXIT LIGHT ABOVE FA SEAT INOP. C/A-THROUBLESHOT FWD EXIT LIGHT IAW FIM 33-50-00-810-804-A FOUND TO BE INVERTER #1 REMOVED AND REPLACED INVERTER #1 IAW AMM 33-50-11 OPS CHECK GOOD.SDR ASOA201908305098Light · inoperativeDURING MX INSPECTION THE RIGHT OVER WING EMERGENCY LIGHT WAS NOT ILLUMINATING. MX REMOVED AND REPLACED RT OVER WING EMERGENCY LIGHT IAW AMM 33-50-07 OPS CHECKED GOOD AT THIS TIME. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA201908305097Light · inoperativeDURING MX INSPECTION THE EMERGENCY LIGHT SYSTEM BATTERY POWERED FLOOR PROXIMITY STRIP AT SEATS 18 THROUGH 20 NOT ILLUMINATING ( EMERGENCY LIGHTING SYSTEM (BATTERY POWERED) FLOOR PROXIMITY STRIPS ITEM MOVED TO DMIL OPERATE PER MEL 33-50-00-2 EXP 09-50-00-2 CAT SDR SIMA2019083029005Inverter · inoperativeDURING PS-2 CHECK, FOUND EMERGENCY EXIT LIGHT NEAR PAX DOOR ABOVE FA HEADREST INOPERATIVE. REMOVED AND REPLACED THE NR 1 INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD. NO OTHER DEFECTS NOTED.SDR SIMA2019083029006Battery Pack · inoperativeDURING PS-2 CHECK, FOUND THE CEILING EMERGENCY EXIT SIGN NEAR OVERWING EMERGENCY ROW INOPERATIVE. REMOVED AND REPLACED THE NR 4 EMERGENCY BATTERY IAW AMM 33-50-04. OPS CHECKED GOOD.SDR ASOA201908297103Door Frame · corrodedTYS A/C IS IN C-CHECK WHEN INSPECTION FOUND CORROSION AT THE CARGO CUTOUT AT FRAME 65 AND STRINGER 17L. MAINTENANCE REMOVED AND REPLACED THE DAMAGE AREA IAW EMB 145 ETD-145-115762. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.SDR ASOA201908297102Frame · corrodedTYS A/C IS IN FOR A C-CHECK WHEN INSPECTION FOUND CORROSION AT FRAME 65 AFT SIDE SUPPORT BRACKET AT STRINGER 16L. MAINTENANCE REMOVED AND REPLACED THE DAMAGED AREA IAW EMB 145 ETD2019-145-114447. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHSDR HNAA2019083000243Warning Message · false activationREJECTED TAKE OFF. AT 50 KNOTS HSV 1 FAILED MESSAGE DISPLAYED ON EICAS. AND THEN WENT AWAY AFTER THROTTLE AND BACK TO IDLE. PERFORMED OPS CHECK OF HS VALVE IAW AMM 36-11-02, NO DEFECTS NOTED. OPS CHECKED GOOD. OK FOR SERVICESDR HNAA2019083000242Display · malfunctionedFO MFD DU SWAPPED FROM NR 3 POSITION DUE TO GOING BLANK DURING TAKE OFF ROLL. PERFORMED OPS CHECK IAW AMM 34-22-00. OPS CHECKED NORMAL. POWERED DOWN AND POWERED UP AIRCRAFT. OPS CHECKED F/O MFD NORMAL. COULD NOT DUPLICATE. OK FOR SERVICE.SDR HNAA2019083000241Display · malfunctionedEICAS WENT BLANK DURING TAKE OFF ROLL AND CAME BACK AFTER SEVERAL SECONDS. SWAPPED DU3 WITH DU4 IAW AMM 34-22-01-04. OPS CHECKED IAW AMM 34-22-00-05. OPS CHECKED GOOD.SDR ASOA201908297101Elevator · damagedREMOVED DOUBLER REPAIR ON TRAILING EDGE OF LT ELEVATOR FOR REPAIR. PERFORMED REPAIR OF LH ELEVATOR IAW ETD 2019-145-113923.SDR ASOA201908297100Skin · dentedDISCREPANCY: DENT IN FUSELAGE AT STRINGER 11L AND 12L BETWEEN FRAMES 19A AND 20. CORRECTIVE ACTION: REPAIRED FUSELAGE SKIN IN ACCORDANCE WITH EMB ETD 2019-145-112063.SDR SIMA20190828001Fan · failedSTRONG FOUL ODOR COMING FROM RUNNING THE PACKS-C/A-FOUND STRONG ODOR COMING FROM GASPERFAN (PAX VENTS AND COCKPIT VENTS) DEFERED GASPER FAN AS PER MEL 21-4 (M) PROCEDURES C/W. REPLACED GASPER FAN IAW EMB 145 AMM 21-23-03 NORMAL OPERATION NOTED MEL 21-4 RESTORESDR SIMA201908287005Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOP. REMOVED AND REPLACED MAIN DOOR EMERGENCY LIGHT IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD, NO DEFECTS NOTED AT THIS TIME. END.SDR HNAA2019082800240Potentiometer · failedWITH TILLER ENGAGED UNCOMMANDED STEERING TO LEFT AND RIGHT WITH NOTED CLICKING AND GRINDING SOUND HEARD. REPLACED FEEDBACK UNIT (POTENENTIOMETER) IAW 30-50-07 PERFORMED COMPLETE ADJUSTMENT IAW AMM 32-50-00-700-804/500. TAXI CHECK NO FIX. REPLACED STEERING HASDR SIMA201908276002O-Ring · failedBLEED 2 LEAK AFTER AUDIBLE POP SOUND. REMOVED AND REPLACED O-RINGS AND COUPLING COVER AT BLEED COUPLING #8 IAW AMM 36-11-10. BLEED 2 LEAK CHECK GOOD IAW AMM 36-11-09-200-803.SDR SIMA201908276001Circuit Breaker · shortedCIRCUIT BREAKER BEHIND CAPTAIN SEAT B2 (HEAT PITOT 1) WHEN PULLED ELECTRIC BURN SMELL.-C/A-FOUND K0054 RELAY PITOT CURRENT SENSOR TO HAVE A ELECTRIC BURN SMELL. REMOVED AND REPLACED PITOT CURRENT SENSOR K0054 IAW EMB 145 AMM 30-31-01. PERFORMED OPERATIONAL CHESDR SIMA201908265002Wire · brokenEMER. LIGHT WIRES BROKEN AT PANEL 251BF. SECURED WIRING CONNECTORS ON FLOOR PROXIMITY LIGHTS AT ROW 5/6 IAW AMM 33-50-12 OPS CHECK GOOD.SDR SIMA201908265001Inverter · inoperativeCENTER AISLE EMERGENCY LIGHT SYSTEM IS INOP. REMOVED AND REPLACED THE NR 5 DC/AC INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD.SDR HNAA2019082600238Light · inoperativeRIGHT OVERWING EMERGENCY LIGHT INOP. REPLACED RH EMERGENCY LIGHT IAW AMM 33-50-10-000/400-801-A. OPS CHECK GOODSDR HNAA2019083000244Web · damagedCARGO DOOR INTERIOR WEB HAS A MISDRILLED HOLE. R&R INTERIOR CARGO DOOR LOWER WEB - MAJOR REPAIRSDR ASOA2019082844048Ground Stud · dirtyFLIGHT 4368 THE EMERGENCY LIGHT ON THE PAX DOOR WAS FOUND TO BE INOPERATIVE. MAINTENANCE INSPECTED THE AIRCRAFT AND CLEANED THE GROUND CONNECTION ON THE LIGHT. OPERATIONALLY TESTED WITH NO DEFECTS, REMOVED THE MEL, AND THE AIRCRAFT WAS APPROVED FOR RETURN TOSDR SIMA201908264001Acm · failedAFTER TAKEOFF FLIGHT ATTENDANT REPORTED SMOKE IN THE CABIN AND A BURNING SMELL. ALSO REPORTED AN ABNORMAL SOUND COMING FROM ENGINE OR ACM. "TRANSFERRED TO NRWC 675-SGF-03210" DD 626301-C/A-T/S PER FIM 21-20-00-810-801-A, REMOVED AND REPLACED RH ACM, HEAT EXCHASDR SIMA201908264002Inverter · inoperativeDURING PS-2 FOUND EMERGENCY EXIT LOCATING SIGN INOP-C/A-REMOVED AND REPLACED # 1 INVERTER IAW 145 AMM 33-50-11 OPS CHECK GOOD NO FURTHER DEFECTS NOTEDSDR SIMA201908263003Light · inoperativeRH WING FWD EMERGENCY LIGHT INOP. REMOVED AND REPLACED RH FWD EMERGENCY LIGHT IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A OPC GOODSDR HNAA2019082600239Dau · failedDAU 1A FAILED ON ROLL OUT, REJECTED TAKE-OFF. REMOVED AND REPLACED IC600 IAW AMM 31-42-00 OPS CHECK GOOD. OK FOR SERVICESDR HNAA2019082600237Light · inoperativeRT OVERWING EMERGENCY LIGHT DOES NOT ILLUMINATE. REPLACED OVERWING EMERGENCY LIGHT ASSY IAW AMM 33-50-10-000/400-801-A. OPS CHECK GOODSDR HNAA2019082600236Connector · brokenEMERGENCY LIGHT AT SEAT 16A HAS BROKEN CONNECTOR. REPLACED EMERGENCY FLOOR LIGHT AT ROW 16A IAW AMM 33-50-12-000/400-801-A, OS CHECK GOODSDR ASOA201908223046Skin · crackedDURING C CHECK INSPECTION FOUND 2 CRACKS AT RIVETS AT FRAME 75 JUST ABOVE AND BELOW STRINGER 2R. MAINTENANCE REPAIRED IAW SRM 53-31-01.SDR SIMA201908232001Warning Message · false activationPITOT 2 INOPERATIVE EICAS MESSAGE. PERFORMED AN OPERATIONAL CHECK OF PITOT NR 2 IAW AMM 30-31-00. NO EICAS OR CMC MESSAGES FOUND. OPS CHECKED GOOD. NO DEFECTS NOTED.SDR HNAA2019082300235Control Module · malfunctionedEMERGENCY LIGHT NOT ARMED, EICAS MESSAGE DISPLAYED. REMOVED AND REPLACED CONTROL MODULE ASSY IAW AMM 33-21-01 SUBTASK 33-25-00-700-801-A AND 33-50-00-700-801-A. OPS CHECK GOOD,OK FOR SERVICESDR HNAA2019082300234Light · inoperativeEMERGENCY PATH LIGHT SECTION 7 INOP. R&R EMERGENCY PATH LIGHT SECTION 7 IAW AMM 33-50-12-04. OPS CHECK GOODSDR ASOA2019082324047Skin · crackedDURING A-CHECK INSPECTION, THE CROWN SKIN AT THE UPPER AFT CORNER OF THE F/O'S DV WINDOW WAS FOUND TO BE CRACKED. MAINTENANCE REMOVED THE CRACK AREA AND PERFORMED A TRIPLER REPAIR IN ACCORDANCE WITH EMBRAER TECHNICAL DISPOSITION ETD2019-145-106582, AND THE AISDR HNAA2019083000245Door Frame · crackedCOCKPIT UNDERFLOOR ACCESS HATCH FRAME IS CRACKED. REPLACED THE FRAME - MAJOR REPAIRSDR SIMA201908221002Bleed Valve · failedAPU BLEED VALVE FAIL WITH THE OPEN INSCRIPTION ILLUMINATED. REMOVED AND REPLACED APU BLEED VALVE IAW AMM 36-12-03. OPC GOOD.SDR SIMA201908231007Engine · failedPOSSIBLE APU FIRE, SMOKE COMING FROM APU INTAKE. REMOVED AND REPLACED APU IAW W/C 49-800-05. OPS CHECK GOOD LEAK CHECK GOOD.SDR SIMA201908221006Charger · failedL/H AND R/H OVER WING EMER. LIGHTS INOP. REMOVED AND REPLACED #4 EMERG. LIGHT CHARGER AND BATTERY ASSYS, OPC GOOD, IAW AMM 33-50-04.SDR SIMA201908221005Light · inoperativeL/H OVERWING EXT EMERGENCY LIGHT INOP.-C/A-REMOVED AND REPLACED THE LH OVERWING EXIT LIGHT IAW EMB 145 AMM 33-50-10. OPC GOOD.
Back to Embraer EMB-145LR