Embraer EMB-145LR

Service difficulty reports · 36,797

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR HNAA2019091600272Controller · defectivePDIS 695 05-50 1904473 14SEP19 CLT CLOSE REOCCURING ELECTRICAL ODOR OBSERVED MULTIPLE TIMES IN FLIGHT DECK. FACT 14SEP19 16:39 CLT T/S AND FOUND FO'S W/S HEAT DRAWING EXCESSIVE CURRENT. INSPECTED W/S CONNECTIONS AND CONTACTORS, NO DEFECTS NOTED. R+R Sep 14, 2019 · N695AE · Emb EMB145LR · Windshield/Door Rain/Ice RemovalSDR RAIA201910091302Door Frame · crackedAFT AVIONICS DOOR FRAME WAS CRACKED UNDER HINGE BRACKET. REPAIRED WITH A DOUBLER AND FILLER AND INSTALLED REPAIR.Sep 13, 2019 · N836HK · Emb EMB145LR · Fuselage Main, StructureSDR RAIA2019100891301Frame · crackedCOCKPIT UNDERFLOOR HATCH 123BL FRAME IS CRACKED UNDER HINGE BRACKET....REPAIRED COCKPIT UNDERFLOOR HINGE 123BL.Sep 13, 2019 · N836HK · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20190913002Flashlight · damagedFWD FLIGHT ATTENDANT FLASHLIGHT FOUND DAMAGED. C/A-REMOVED AND REPLACED FWD FLIGHT ATTENDANT FLASHLIGHT IAW AMM 33-50-16. OPS CHECK GOOD.Sep 13, 2019 · N607AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20190913001Smoke Detector · malfunctionedWHEN RELEASING THE PARKING BRAKE BAGG SMOKE MASTER CAUTION ILL. "TRANSFERRED TO NRWC # 606-MIA-02757" . -C/A-FOUND BAGGAGE FIRE BOTTLES DISCHARGED. REMOVED AND REPLACED BAGGAGE FIRE BOTTLES IAW AMM 26-23-01 AND REMOVED AND REPLACED FWD AND AFT SMOKE DETECTORS Sep 13, 2019 · N606AE · Emb EMB145LR · Smoke DetectionSDR SIMA20190912001Actuator · failedPTRIM MAIN INOP "TRANSFERRED TO NRWC 698-ORD-04545". WLS 1 HEAT FAIL. C/A-REMOVED AND REPLACED HORIZONTAL-STABILIZER ACTUATOR IAW AMM 27-40-02 PERFORMED ELECTRICAL ZERO POSITION OF THE HORIZONTAL STABILIZER IAW AMM 27-40-02. OPS CHECK GOOD. PERFORMED OPERATIONSep 12, 2019 · N698CB · Emb EMB145LR · Stabilizer ActuatorSDR HNAA2019091300269Warning System · false activationPDIS 626 78-32 1830691 12SEP19 CLT CLOSE E1 T/R DISAGREE MSG DISPLAYED ON TAKEOFF ROLL. C/W MX PROCEDURE. NOTE CMC SHOWS E1 T/R VALVE FAIL. FACT 13SEP19 01:07 MDT REACTIVATED #1 T/R CND REF FIM TASK 78-34-00-810-804A,R&R'D RELAY K0641. OPERATED TSep 12, 2019 · N626AE · Emb EMB145LR · Engine Thrust ReverserSDR HNAA2019091300268Warning System · false activationPDIS 624 49-10 1881591 12SEP19 PHL CLOSE APU FAIL MESSAGE ON EICAS. 28876 00 MDC FACT 12SEP19 19:23 PHL PERFORMED ELECTRICAL RESET, OPERATED APU FOR 30 MINS WITH BOTH PACKS ON. OPS NORMAL, OK FOR SERVICE.Sep 12, 2019 · N624AE · Emb EMB145LR · APU Indicating SystemSDR HNAA2019091600280Door Frame · corrodedDISCREPANCY: FRAME 68 L-PROFILE IS CORRODED AT THE BOTTOM AT THE CARGO DOOR CUTOUT. CORRECTIVE ACTION: REPAIRED AREA IAW SRM 53-31-04-RE ITEM 4 AND EO1-53-19-0379.Sep 11, 2019 · N625AE · Emb EMB145LR · Fuselage Main, StructureSDR HNAA2019091300271Warning System · false activationRTO AT 40KTS DUE CAUTION LIGHT ILLUMINATED. NO EMERGENCY. ISSUE WAS FIXED ITSELF SOON AFTER EXITING THE RUNWAY. FLT CONTINUE ON TO OAJ LOCATION.Sep 11, 2019 · N639AE · Emb EMB145LR · Central WarningSDR HNAA2019091300270Warning System · malfunctionedPDIS 657 31-50 2067831 11SEP19 PHL ASSGN CAPT CAUTION LIGHT DOES NOT EXTINGUISH. MEL 11SEP19 21:28 PHL C25422 31-7-1 MASTER CAUTION LIGHTS.Sep 11, 2019 · N657AE · Emb EMB145LR · Central WarningSDR SIMA20190911004Control Unit · failedPTRIM MAIN INOP FL 270, BACKUP PTRIM OPERATED NORMALLY. "TRANSFERRED TO NRWC 698-ORD-04543" PTRIM MAIN INOP. C/A-REMOVED AND REPLACED HSCU IAW AMM 27-40-01. OPC GOOD.Sep 11, 2019 · N698CB · Emb EMB145LR · Stabilizer Control SystemSDR SIMA20190911001Battery · dischargedREAR HALF OF EMERGENCT EXIT LIGHTS BATTERY DIES AFTER 2 MINUTES. C/A-REMOVED AND REPLACED #4 EMERGENCY LIGHT BATTERY AND CHARGER IAW WC# 33-700-19.Sep 11, 2019 · N673AE · Emb EMB145LR · Emergency LightingSDR SIMA20190911005Light · inoperativeDURING PS-1 CHK FOUND RT OVERWING EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED RT OVERWING EMERGENCY LIGHT BULB IAW AMM 33-50-10. OPS CHK GOOD.Sep 11, 2019 · N615AE · Emb EMB145LR · Emergency LightingSDR SIMA20190910005Light · inoperativeSUPPLEMENTAL # 4 FLOOR EMERGENCY LIGHT STRIP INOP. C/A- DEFERRED PER MEL 33-30. REMOVED AND REPLACED #4 EMERG FLOOR STRIP IAW AMM 33-50-12 OPS CHECK GOOD MEL RESTORED.Sep 10, 2019 · N685AE · Emb EMB145LR · Emergency LightingSDR HNAA2019091600277Frame · crackedDISCREPANCY: POSSIBLE CRACK AROUND RIVET AT FR 78 BTW STR 4R-5R. CORRECTIVE ACTION: PERFORMED DYE PENETRANT INSP CRACK INDICATED. REPAIRED AREA IAW SRM53-32-01 AND EO1-53-19-03914.Sep 10, 2019 · N625AE · Emb EMB145LR · Fuselage Main, FrameSDR HNAA2019091600276Frame · crackedDISCREPANCY: POSSEBLE CRACK AROUND RIVET AT FR 79 BTW STR 5R-6R. CORRECTIVE ACTION: PERFORMED NDT CRACK INDICATED. REPAIRED AREA IAW SRM 53-32-01.Sep 10, 2019 · N625 · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20190910002Light · inoperativeDURING PS1 FOUND LT FORWARD EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED EXTERNAL EMERGENCY LIGHT LAMP IAW AMM-33-50-10. OPS CHECK GOOD.Sep 10, 2019 · N693AE · Emb EMB145LR · Emergency LightingSDR SIMA20190910001Inverter · inoperative#1 FLOOR PROX EMERG LIGHT STRIP IS INOP. C/A-REMOVED AND REPLACED #2 DC/AC EMERGENCE EXIT LIGHTING INVERTER. OPS CHECKED GOOD IAW AMM 33-50-11.Sep 10, 2019 · N676AE · Emb EMB145LR · Emergency LightingSDR HNAA2019091100267Generator · malfunctionedGEN #3 SHOWING AMBER DASHES AND 0 AMPS DURING FLIGHT. FIX: R&R GEN 3 IAW AMM 24-31-01 LEAK AND OPS CHECK GOOD. NOTE: AIRCRAFT DIVERTED FROM YQB TO ALB TO BE FIXED.Sep 10, 2019 · N638AE · Emb EMB145LR · AC Generator-AlternatorSDR ASOA201909103054Beam · crackedDURING LEFT DV WINDOW BEAM REPLACEMENT (DUE TO CRACK) THE FORWARD FUSELAGE II SKIN PARTIALLY COVERED RIVET THAT REQUIRED REMOVAL. MAINTENANCE TRIMED FORWARD FUSELAGE II SKIN WHERE FASTENER WAS PARTIALLY COVERED AND REMOVED RIVET. WORK ACCOMPLISHED IAW ETD2019-Sep 10, 2019 · N14993 · Emb EMB145LR · Fuselage Main, StructureSDR HNAA2019091600279Floor Support · corrodedDISCREPANCY: CENTER OMEGA BEAM CENTER ISLE FLOOR SUPPORT CORRODED BELOW CROSSBEAM FR-29. CORRECTIVE ACTION: REPAIRED IAW ETD2019-145-113837 REV A AND EO1-53-19-0361.Sep 9, 2019 · N625 · Emb EMB145LR · Fuselage Miscellaneous StructureSDR HNAA2019091600275Floor Support · corrodedLT OMEGA BEAM CENTER ISLE FLOOR SUPPORT CORRODED AT CROSSBEAM FR-29. REPAIRED LT OMEGA BEAM CENTER ISLE FLOOR SUPPORT AT CROOSSBEAM FR-29 IAW ETD2019-145-113844 REV A AND EO1-53-19-0360.Sep 9, 2019 · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20190908004Anti-Ice Valve · failedSUPPLEMENTAL ENG(2) ANTI ICE FAIL. C/A-ENG 2 A/ICE VLV FAIL MSG ON CMC, FOLLOWED FIM TASK 30-21-00-810-804-A. FAIL RT ENGINE A/ICE VALVE. DEFERRED PER MEL 30-11. AUTH# 090264DM-C C/W "M" PROCEDURES. REMOVED AND REPLACED ENG 2 A/ICE VALVE, OPC GOOD, IAW AMM 30Sep 8, 2019 · N667GB · Emb EMB145LR · Air Intake Anti/De-Ice SystemSDR ASOA201909085099Wire · brokenMX REPORTED THE EMERGENCY FLOOR PROXIMITY STRIP LIGHT BY WING EMERGENCY EXIT INOP. MX REPAIRED EMERGENCY STRIP BROKEN WIRE AND PERFORMED OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.Sep 8, 2019 · N15980 · Emb EMB145LR · Light System WiringSDR HNAA2019090900266Acm · seizedPDIS 645 21-01 2075172 08SEP19 MDT CLOSE SMOKE IN COCKPIT AT FL 210 CREW RAN QRH. NO EICAS MESSAGES PRESENT. FACT 08SEP19 11:33 MDT FOUND #1 ACM SEIZED R&R'D #1 ACM REF AMM 21-51-03 OPS CK GOOD AT THIS TIME.Sep 8, 2019 · N645AE · Emb EMB145LR · Cabin Cooling SystemSDR HNAA2019090900265Warning System · false activationRTO DUE NO T/O CONFIG BRAKE WARNING AT 60KTS. NO EMERGENCY. CREW/PAX OKAY. MESSAGE CLEARED AND A/C IS GOOD TO GO BY MAINTENANCE.Sep 8, 2019 · N660CL · Emb EMB145LR · Landing Gear Brake SystemSDR HNAA2019090900264Pressure Switch · defectivePDIS 633 31-50 1884491 08SEP19 PHL CLOSE TAKEOFF BRAKES WARNING. MSG COMES UP INTERMITTENTLY WITH THE EMERGENCY BRAKE RELEASED. FACT 08SEP19 13:24 PHL R&R PRES SW (EMRG/PRK BRK) IAW AMM 32-44-07 NO LEAKS NOTED. OPS CK TO CFG GOOD NO ERRONEOUS MSG. Sep 8, 2019 · N633AE · Emb EMB145LR · Landing Gear Brake SystemSDR HNAA2019090900263Inverter · inoperativeCOCKPIT STEP EMERGENCY LIGHT INOP. R&R #100 EMERGENCY LIGHT INVERTER IAW 33-50-11-00/400-801-A. OKAY FOR SERVICE.Sep 8, 2019 · N642AE · Emb EMB145LR · Emergency LightingSDR HNAA2019090900262Wire · brokenEMERGENCY LIGHT AT SERVICE DOOR HINGE ASSY IS INOP. FOUND BROKEN WIRE. SPLICED WIRE, OPS CHECK GOOD.Sep 8, 2019 · N672AE · Emb EMB145LR · Light System WiringSDR SIMA20190908003Fan · inoperativeREJECTED TAKE-OFF AT 90 KNOTS DUE TO STRONG ELECTRICAL BURN SMELL IN THE FLIGHT DECK. C/A-FOUND FWD ELEC BAY LT RECIRC FAN INOP. REMOVED AND REPLACED FAN IAW AMM 21-26-02. OPS CK GOOD. PERFORMED ETN-EM-72-034. ODOR WAS NOTICEABLE AT STEP 8 AT MAX POWER SETTINGSep 8, 2019 · N932AE · Emb EMB145LR · Air Distribution FanSDR SIMA20190908002Light · inoperativeMAIN DOOR EXTERIOR EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED MAIN DOOR EXTERIOR EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD.Sep 8, 2019 · N605KS · Emb EMB145LR · Emergency LightingSDR HNAA2019090900257Unknown · malfunctionedPDIS 656 32-20 1899841 08SEP19 PHL CLOSE ON GEAR RETRACTION NLG DOORS REMAINDS OPEN FACT 08SEP19 17:21 PHL PERFORMED OPS CHECK OF LANDING GEAR. OPS CHECK GOOD. NO DEFECTS NOTED. OK FOR SERVICE.Sep 8, 2019 · N656AE · Emb EMB145LR · Landing Gear Door Retract SectionSDR HNAA2019090900256Unknown · smokePDIS 906 05-50 1898563 09SEP19 RDU ASSGN IN CRUISE FLIGHT BURNING SMELL NOTED IN FLT DECK AND CABIN W/ NOTED VISIBLE SMOKE IN CABIN (REPORTED BY F/A) SMELL AND SMOKE DISSIPATED UPON DESCENDING WITH PACK 2 OVHT EICAS MSG PRESENT AFTER LANDING. AIRCRAFTSep 8, 2019 · N906AE · Emb EMB145LR · Air Distribution SystemSDR HNAA2019090900255Unknown · odorPDIS 906 05-50 1898561 08SEP19 CLT CLOSE ELECTRICAL SMELL IN FLIGHT DECK FACT 08SEP19 22:55 CLT INSPECTED BEHIND RELAY PANELS, CHECKED ENGINE INTAKES. RAN BOTH PACKS. NO ELECTRICAL SMELL NOTED. UPON FURTHER INSPECTION, FOUND OIL SMELL PRESENT INTERSep 8, 2019 · N906AE · Emb EMB145LR · Air Distribution SystemSDR ASOA2019100273057Beam · crackedDURING C CHECK INSPECTION FOUND CRACK ON LEFT DV WINDOW LOWER BEAM. MAINTENANCE REPLACED LEFT DV WINDOW LOWER BEAM I/A/W ETD 2019-145-124119 AND SB145-53-0023Sep 7, 2019 · N14993 · Emb EMB145LR · Fuselage Main, StructureSDR HNAA2019091600278Door Frame · corrodedDISCREPANCY: FRAME 65 L-PROFILE IS CORRODED AT THE BOTTOM AT THE CARGO DOOR CUTOUT. CORRECTIVE ACTION: PERFORMED REPAIR IAW SRM 53-31-04 AND EO1-53-19-0378.Sep 7, 2019 · N625AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20190907002Light · inoperativeLEFT OVERWING EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED LEFT OVERWING EMERGENCY LIGHT BULB, IAW AMM 33-50-07. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.Sep 7, 2019 · N681AE · Emb EMB145LR · Emergency LightingSDR HNAA2019090900259Thermostat · malfunctionedPDIS 640 30-10 1826421 07SEP19 ART CLOSE DURING ICING, WG A/ICE FAIL MSG ON EICAS, CREW C/W QRH, MESSAGE CLEARED. FACT WING A/I LEAK MESSAGE ON CMC. FOUND BLEED PIPE BETWEEN PACK VLV #1 AND TEMP CONTROL VLV #1 TO BE LEAKING. R&R'D PIPE IRT AMM 21-60-0Sep 7, 2019 · N640AE · Emb EMB145LR · Airfoil Anti/De-ice SystemSDR HNAA2019090900258Unknown · malfunctionedPDIS 660 31-40 2006861 07SEP19 PHL CLOSE FO'S PFD SHOWED NO AIRSPEED INDICATION DURING TAKEOFF ROLL FACT 07SEP19 23:57 PHL PERFORMED ADC OPS CHECK IAW AMM 34-15-00. OPS CHECK GOOD. OK FOR SERVICE.Sep 7, 2019 · N660CL · Emb EMB145LR · Airspeed/Mach IndicatorSDR RAIA201909060001Target · damagedLANDING GEAR AIR GROUND FAIL MESSAGE ON CLIMBOUT. R&R NLG WOW PROX SWITCH TARGET ON UPPER TORQUE LINK. OPS CHECK GOOD.Sep 6, 2019 · N842HK · Emb EMB145LR · Landing Gear Position and WarningSDR HNAA2019090900261Bleed Valve · malfunctionedPDIS 639 36-21 2095731 05SEP19 RIC CLOSE #1 BLEED VLV EICAS MSG ON TAKEOFF FACT 05SEP19 04:36 RIC REMOVED AND REPLACED #1 ENG BLEED VALVE IN REF TO AMM 36-11-05-000/400-801A. OPS CHECK #1 BLEED SYSTEM O IN REF TO AMM 36-00-00-700-803A OPS CHECK GOOSep 6, 2019 · N639AE · Emb EMB145LR · Compressor Bleed ValveSDR HNAA2019090900260Pressure Switch · malfunctionedPDIS 632 29-10 1948251 06SEP19 CLT CLOSE RUDDER SYS 1/2 INOP MSG IN FLIGHT WEITH HYD SYSTEM 1 FAIL MSG INTERMITTENT. 27717 00 RNR HISTORY: NONE FACT 06SEP19 17:23 CLT R&R RUDDER PRESSURE SWITCH PER AMM 27-23-04 OPS + LEAK CHECK GOOD. OK FOR SERSep 6, 2019 · N632AE · Emb EMB145LR · Rudder Control SystemSDR SIMA20190906002Light · inoperativeLT WING EMERGENCY EXIT LIGHT MOUNTED IN PSU COVER IS INOP. C/A-REMOVED AND INSTALL LAMP AT SEAT ROW 12A LT WING EMERG EXIT. REF AMM 33-50-08. OPS CHK GOOD PER AMM TASK 33-50-00-700-801-A/500Sep 6, 2019 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20190906004Light · inoperativeEMERGENCY LIGHT MOUNTED IN SERICE DOOR HINGE COVER IS INOP. C/A-REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT ASSY IAW AMM 33-50-10. OPS CK GOOD.Sep 6, 2019 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20190906003Light · inoperativeEMERGENCY LIGHT MOUNTED IN MAIN PAX DOOR HINGE COVER IS INOP. C/A-REMOVED AND INSTALL LAMP IN MAIN PAX DOOR EMERG LIGHT. REF AMM 33-50-10. OPS CHK GOOD PER AMM TASK 33-50-00-700-801-A/500.Sep 6, 2019 · N623AE · Emb EMB145LR · Emergency LightingSDR ASOA201909063045Light · inoperativeTHE CREW REPORTED FLOOR PROXIMITY EMERGENCY LIGHT STRIP @ ROW 10 WAS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY FLOOR LIGHT STRIP AT ROW 10.Sep 6, 2019 · N17984 · Emb EMB145LR · Emergency LightingSDR HNAA2019090700254Fuse · blownFWD CEILING EMERGENCY LIGHT INOP. FIX: REMOVED #1 EMERGENCY LIGHTING SYS BATTERY, FOUND BAD FUSE ON BATTERY PACK BASE. R&RD FUSE. REINSTALLED #1 BATTERY.Sep 6, 2019 · N3350 · Emb EMB145LR · Emergency LightingSDR HNAA2019090700253Fuse · blownPAX DOOR EMERGENCY LIGHT INOP. FIX: REMOVED #1 EMERGENCY LIGHTING SYS BATTERY. FOUND BAD FUSE ON BATTERY PACK BASE. R&RD FUSE. REINSTALLED BATTERY.Sep 6, 2019 · N645AE · Emb EMB145LR · Emergency LightingSDR HNAA2011909060025Bleed Valve · failed#1 BLEED VALVE EICAS MESSAGE ON TAKE-OFF. REMOVED AND REPLACED NR 1 BLEED VALVE IN IAW AMM 36-11-05-000/400-801A. OPS CHECK NR 1 BLEED IAW AMM 36-00-00-700-803A. OPS CHECK GOOD AT THIS TIME.OK FOR SERVICESep 5, 2019 · N639AE · Emb EMB145LR · Compressor Bleed Valve
Back to Embraer EMB-145LR