SDR SIMA2019042919008Shear Tie · crackedRH SHEARCLIP AT FRAME 80 BETWEEN STRINGERS 4R AND 5R HAS A 3/8 INCH CRACK.-C/A-REMOVED AND REPLACED RH SHEARCLIP AT FRAME 80 BETWEEN STR 4R-5R IAW SRM 51-40-02.SDR SIMA2019042619005Shear Tie · crackedFRAME SUPPORT FOR FRAME 46 AT STR 15R IS CRACKED.-C/A-RAR FRAME SUPPORT BRACKET AT FRAME 46 IAW SRM 51-40-02.SDR Y0CB20190424003Relay · burnedAIRCRAFT WAS BEING REPOSITIONED AND WAS AT 12,000 FEET CROSSING OVER THUNDERSTORMS WHEN THE EICAS DISPLAYED A PITOT 2 FAIL MESSAGE. A STRONG ELECTRICAL ODOR FOLLOWED ALONG WITH SMOKE COMING FROM THE RT SIDE OF THE COCKPIT. THE PILOTS FOLLOWED EMERGENCY ACTIOSDR SIMA2019042319004Support · crackedBRACKET ON FR 68 FOR BAGGAGE DOOR HOLD OPEN ROD SUPPORT IS CRACKED.-C/A-REMOVED AND REPLACED SUPPORT BRACKET ON FRAME 68 FOR BAGGAGE DOOR HOLD OPEN SUPPORT ROD BRACKET IAW SRM 51-40-02.SDR SIMA2019042319003Skin · crackedFUSELAGE SKIN HAS A CRACK INDICATION .125 INCHES IN LENGTH 1 RIVET BELOW STRINGER 6L AT FRAME 77 -C/A-EVALUATED WITH HFEC FOUND NO CRACK. RESTORED SURFACE PROTECTION IAW CPM 51-25-01.SDR HNAA2019042200113Bleed Valve · malfunctioned648 36-21 1937982 19APR19 BTV CLOSE
ENG 1 BLEED VALVE FAIL MESSAGE ON TAKE OFF
39524 00 JBU
FACT 20APR19 02:25 BTV
R\R ENGINE BLEED VALVE ON #1 ENGINE IAW EMB 145 AMM
36SDR SIMA20190419002Stringer · corrodedSTR 17R BTW FR 3-4 HAS CORROSION ALONG UPPER EDGE. REPAIRED STR 17R BTW FR 3-4 IAW ERS-EM-53MR-3742SDR SIMA2019042219001Controller · failedAIRCRAFT BEGAN TO LOOSE PRESSURAZATION DURING CLIMB CABIN ALTITTUDE CONTINUED TO INCREASE UNTIL CLIMB STOPPED DESCENT BEGAN-C/A-DEFERRED AUTO AND MANUAL PRESSURAZATION M PROCEDURES C/W REF MEL 21-19 AUTH 040646DM-C. TS IAW 21-31-00-810-801-A REMOVED AND REPLACSDR HNAA2019042200112Connector · dirtyPDIS 648 36-10 1937981 19APR19 BTV CLOSE
E1 BLEED VALVE FAIL MESSAGE ON TAKEOFF.
CREW REPORTED MESSAGE APPEARS AT 70 PERCENT N1
FACT 19APR19 14:30 BTV
INSPECTED AND CLEANED ENGINE 1 BLEED VALVE CANNON
SDR SIMA20190418004Floor Support · corrodedLT OMEGA BEAM CORRODED AT FRAME 29. C/A-REPAIRED LT OMEGA BEAM AT FR 29 IAW ERS-53MR-3756.SDR SIMA2019042418003Door Sill · corrodedCENTER SERVICE DOOR SILL IS CORRODED.-C/A-INSTALLED NEW CENTER SERVICE DOOR SILL IAW SRM 51-40-02.SDR HNAA2019042200106Pressure Switch · malfunctionedPDIS 665 30-21 1872011 18APR19 BTV CLOSE
E2 A/I INOP MSG DISP ON T/O ROLL. C/W MAINTENANCE PR
OCEDURE.
FACT 18APR19 07:56 PHL
R&R PRESSURE-ELECTRONIC SWITCH IAW EMB 145 AMM 30-21
-06. OPS CHECK GOOD. OK FOR SDR SIMA20190418002Skin · damagedACCOMPLISH PERMANENT REPAIR OF BAGGAGE DOOR SKIN DENT WITH GOUGE-C/A-REPAIRED THE BAGGAGE DOOR SKIN DENT WITH GOUGE IAW ERS-EM-52DF-919 PART C, AND EMB145 SRM 52-30-01SDR SIMA20190418001Frame · corrodedSSI 53-30-48; FRAME 65 IS CORRODED AT STAINLESS GUIDE PLATE BETWEEN STRINGERS 16L-17L-C/A-REPAIRED FRAME 65 AT STAINLESS GUIDE PLATE BTW STRINGERS 16L-17L IAW ERS-EM-53MR-3741SDR ASOA2019042375061Acm · odorPILOT REPORTED A BURNING SMELL NOTICED, PACK 1 OVHT AND DESELECTED PACK SMELL DISSAPATED.MX REMOVED AND REPLACED #1 PACK SYSTEM AIR CYCLE MACHINE WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICESDR ASOA201904175059Module · malfunctionedPILOT REPORTED AFTER T/O THRUST WENT TO T/O RESERVE AND IT COULD NOT BE CHANGED TO ANY OTHER SETTING. A/C PERFORMED SAFE RETURN BACK TO EWR. MX REMOVED AND REPLACED THRUST RATING MODULE PUSH BUTTONS AND PERFORMED OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RESDR ASOA2019042375058Light · inoperativeDURING MX INSPECTION THE CEILING EMERGENCY LIGHT ABOVE SEAT 18A WAS FOUND INOP. MX REPLACED LIGHT ASSEMBLY WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR HNAA2019042200116Bleed Valve · failedPDIS 649 36-21 2050731 17APR19 CLT CLOSE
BLD 1 VLV FAIL MESS INTERMITTENT. MX DEACTIVATED NO1
BLD VALVE PER MEL MX PROCEDURES.
FACT 17APR19 06:13 ROA
R/R'D #1 ENG BLEED VALVE PER AMM 36-11-05. OPS CHECK
S GSDR HNAA2019042200105Warning Light · false activationPDIS 604 33-51 2049463 17APR19 CLT CLOSE
DURING APPROACH EMERGENCY LIGHT NOT ARMED MSG ON EIC
AS, MSG PERSISTED FOR 5 MIN, EMER. LT CAME ON BY THE
MSELVES.
FACT 17APR19 20:30 CLT
PERFORMED EMERGENCY LIGHTS OPERATISDR HNAA2019042200104Bulb · burned outNDIS 604 33-51 0024260 17APR19 SBY CLOSE
EMERGENCY LIGHT ON RH LATERAL PANEL 194ER INOP
30155 00 BAD
FACT 17APR19 10:21 SBY
R&R BULB FOR EMERGENCY LIGHT ON RH LATERAL PANEL 194
SDR SIMA201904187003Lever · bindingPARKING BRAKE LEVER GETS HUNG UP AND IS HARD TO SET-C/A-CLEANED AND LUBED PARKING BRAKE LEVER PEREMB 145 MM12-12-00. NO DEFECTS NOTEDSDR SIMA201904187002Lamp · inoperativeRH WING FWD EXTERIOR EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH WING FWD EXTERIOR EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD. END.SDR ASOA2019041955056Controller · faultyPILOT REPORTED COMING THROUGH 7000MSI LOST ALL PRESSURIZATION WITH NO EICAS WARNINGS PACKS WOULD NOT RESET. MX REMOVED AND REPLACED DIGITAL CONTROLLER WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR HNAA2019041700103A/C Pack · odor638 21-01 2098402 16APR19 FLO CLOSE
ON TAKEOFF FLIGHT DECK FILLED WITH SMELL.ON APPROACH SMELL/HAZE RETURNED AND DISAPATED BEFORE LANDING.
26803 00 SMK
MEL 16APR19 14:25 FLO C10615 21-13SDR HNAA2019041700102Inverter · failed629 33-51 0014160 16APR19 RIC CLOSE
EMERGENCY LIGHT OVER SERVICE DOOR DOORWAY WILL NOT ILLUMINATE
27751 00 NGR
FACT 16APR19 09:57 RIC
DISCONNECTED EMERGENCY LIGHT INVERTER + RESEATEDSDR SIMA201904185004Door Sill · corrodedCARGO DOOR SILL IS CORRODED BEYOND REPAIR-C/A-REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER SILL IAW EMB145 SRM 51-40-02SDR SIMA201904165002Lamp · inoperative12 B/C OVERHEAD EMERGENCY LIGHT INOP. REMOVED AND REPLACED OVERHEAD EMERGENCY LIGHT LAMP AT SEAT 12 B/C IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A OPC GOOD END.SDR ASOA2019041745055Battery Pack · inoperativeMX REPORTED THE EMERGENCY FLOOR LIGHT BY WING EMERGENCY EXIT INOP. REMOVED AND REPLACED THE #3 PSU BATTERY WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA2019041745054Battery Pack · inoperativeMX REPORTED THE EMERGENCY LIGHTS BY WING EMERGENCY EXIT NOT WORKING. REMOVED AND REPLACED THE #3 PSU BATTERY WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA201904154001Light · inoperativeFLOOR PROXIMITY STRIP LIGHT INOP. REMOVED AND REPLACED THE FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12SDR SIMA201904153004Windshield · leakingDURING TAKEOFF AFTER ROTATING FELT WATER DRIP ON HIS HAND. AFTER LOOKING UP THE SOURCE OF THE LEAK WAS THE MAGNETIC COMPASS. WHERE THE COMPASS CONNECTS TO THE WINDSHIELD FRAME. PERFORMED RETORQUE OF CAPT AND FO WINDSHIELD IAW AMM 56-10-01 OPS CHECK GOODSDR HNAA2019041500101Battery Pack · inoperativeEMERGENCY LIGHTS BATTERY INOPERATIVE. REMOVED AND REPLACED THE BATTERY IAW WORKCARD 33-70-19, OK FOR SERVICE.SDR SIMA201904152004Skin · chafedFUSELAGE SKIN CHAFED INSIDE 424DB-C/A-REPAIRED FUSELAGE SKIN CHAFE INSIDE 424DB IAW EMB145 SRM 53-31-01SDR SIMA201904152006Skin · chafedFUSELAGE SKIN CHAFED INSIDE 414DB-C/A-REPAIRED FUSELAGE SKIN CHAFE INSIDE 414DB IAW EMB145 SRM 53-31-01SDR SIMA201904152005Support · corrodedTOILET WASTE VALVE SUPPORT IS CORRODED-C/A-REPAIRED TOILET WASTE VALVE SUPPORT IAW EMB145 SRM 53-31-02SDR SIMA20190411004Light · damagedBOTH AFT EMERGENCY FLOOR LIGHTING EXTRUSIONS IN LAV AREA DAMAGED. C/A-COMPLETE:INSTALLED NEW LT AND RT AFT EMERGENCY FLOOR LIGHTING EXTRUSIONS IN LAV AREA IAW AMM 53-01-02.SDR SIMA20190411003Light · inoperativeNR 3 EMERGENCY FLOOR PATH LIGHT STRIP IS INOP. C/A-COMPLETE: REMOVED AND REPLACED NR 3 FLOOR PATH LIGHT STRIP IAW AMM 33-50-12 (REF NRWC E705441 FOR OPERATIONAL TEST)SDR SIMA20190411002Light · crackedCABIN PROXIMITY LIGHT STRIPS (LT) NR 8,6,4,3,2 AND 1 ARE CRACKED. C/A-COMPLETE:RAR CABIN PROXIMITY LIGHT STRIPS EXTRUSIONS LT NR 8,6,4,3,2,1 IAW AMM 33-50-12 (REF NRWC E705441 FOR OPS TEST)SDR HNAA2019041100095Power Supply · inoperative628 33-51 0016860 10APR19 SBY CLOSE
R/H OVERWING EMERGENCY EXIT LIGHT INOP
FACT 10APR19 08:38 SBY
REMOVED EMERGENCY LIGHT #4 BATTERY & POWER SUPPLY IA
W AMM 33-50-04-000-801A & AMM 33-50-04-000-802A R&R F1 FUSE IN PSDR HNAA2019041100093Extinguisher · leaking657 26-15 1935221 10APR19 ROC CLOSE
BAGBAY EXT. BOTTLE INOP EICAS MESSAGE DISPLAYED. DISCOVERED HALON LEAKING IN BAGBAY.
10APR19 16:11 ROC C10009 26-8
BAG BAY FIRE EXTINGUISHER
FACT 11APR19 02:37 PHL
R&R BAGGSDR SIMA201904110004Cradle · brokenFORWARD FLASHLIGHT HOLDER BROKEN. REMOVED AND REPLACED FORWARD FLASHLIGHT ASSY. OPC GOOD IAW EMB AMM 33-50-16SDR SIMA201904110005Frame · crackedFR 66 FRAME END CRACKED BETWEEN STR 17L AND 18L-C/A-REPAIRED FR 66 IAW ERS-EM-53MR-3731SDR HNAA2019041100096Connector · dirty686 33-20 0010830 09APR19 RIC CLOSE
EMERGENCYH LIGHT AT SEAT 12C INOP
27625 00 NGR
FACT 09APR19 08:42 RIC
CLEANED AND RESEATED CONNECTORS ON EMERGENCY LIGHT A
T SEAT 12CSDR HNAA2019041100094Unknown · odor655 21-01 1854861 09APR19 PHF CLOSE
ELECTRICAL BURNING SMELL IN COCKPIT IN FLIGHT AND
ON THE GROUND.
HISTORY: .
FACT 09APR19 23:52 PHF
MX INSP BOTH RELAY SUPPORT PANELS AND T/S IAW FIM 21
-20-00-810-80SDR SIMA20190409003Shear Tie · corrodedFRAME 65 SHEAR CLIP IS CORRODED AT THE BOTTOM NEAR CARGO DOOR SILL-C/A-REPAIRED FRAME 65 SHEAR CLIP IAW EMB145 SRM 53-31-04SDR SIMA20190409002Wire · brokenLH EMERGENCY PROXIMITY LIGHT #4 WIRES MISSING-C/A-REMOVED AND REPLACED LH EMERGENCY LIGHT #4 IAW EMB145 AMM 33-50-12SDR SIMA20190409004Floor Support · dentedDENT ON RH OMEGA BEAM BETWEEN FR. 49-50-C/A-ACCOMPLISHED REPAIR ON RH OMEGA BEAM BETWEEN FR49 AND 50 IAW ERS-EM-5300-3734 AND EMB145 SRM 53-23-10SDR SIMA20190409001Door Sill · damagedSERVICE DOOR SILL FROM FRAME 20 RT TO 22 RT AT FLOOR LEVEL HAS AREAS OF CORROSION. -C/A-REPAIRED SERVICE DOOR SILL FROM 20-22 RT AT FLOOR LEVEL IAW SRM 53-21-02.SDR RAIA2019040980001Light · inoperativeR/H FWD OVERWING EMERGENCY LIGHT #3 INOP- R/R R/H FWD OVERWING EMERGENCY LIGHT #3 ASSY. OPS CHECK GOOD.SDR SIMA201904098001Channel · out of limitsSERVICE DOOR CUT-OUT FRAME 22 AFT LOWER CORNER OUT OF LIMITS.-C/A-ACCOMPLISHED SERVICE DOOR CUTOUT FR22 REPAIR IAW ERS-EM-53MR-3728
Back to Embraer EMB-145LR