Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20190220001Light · inoperativeLT OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A AND AMM 33-50-10-400-801-A. OPS CHECK GOOD. NO MORE DEFECTS NOTED AT THIS TIME.SDR HNAA2019022000050Light · inoperativeNDIS 625 33-51 0017010 19FEB19 SBY CLOSE
RIGHT HAND EMERGENCY EXIT LIGHT INOP
FACT 19FEB19 09:45 SBY
RR RIGHT HAND EMERGENCY EXIT LIGHT IAW AMM 33-50-14
P/N ON EMERGENCY SDR HNAA2019022000049Battery Pack · inoperativeNDIS 654 33-51 0005550 19FEB19 RIC CLOSE
FWD FUSELAGE RH EMERGENCY LIGHT WILL NOT ILLUMINATE
FACT 19FEB19 07:10 RIC
REMOVED #2 EMERGENCY LIGHT BATTERY. INSPECTED BATTER
YSDR HNAA2019022000048Battery Pack · inoperativeNDIS 654 33-51 0005530 19FEB19 RIC CLOSE
TWO EMERGENCY SERVICE DOOR LIGHTS WILL NOT ILLUMINATE AND ROWS 1-7 EMERGENCY FLOOR PROXIMITY LIGHTS WILL NOT ILLUMINATE
FACT 19FEB19 06:54 RIC
SDR SIMA20190218004Fitting · gougedRT AILERON DAMPER FITTING BOLT HOLE GOUGED. C/A-REMOVED AND REPLACED RT AILERON DAMPER FITTING IAW EM-27MR-112.SDR SIMA20190218005Fitting · chafedLT AILERON DAMPER FITTING CHAFE. C/A-REMOVED AND REPLACED LT AILERON DAMPER FITTING IAW EM-27MR-112.SDR SIMA20190218006Bracket · corrodedFRAME 68 CARGO DOOR CUTOUT LOWER SILL T BRACKET CORRODED. C/A-REMOVED AND REPLACED FRAME 68 CARGO DOOR CUTOUT LOWER SILL T BRACKET IAW SRM 51-40-02.SDR SIMA20190218007Fitting · corrodedFRAME 65 SHEAR CLIP CORRODED AT CARGO DOOR LOWER SILL. C/A-REPAIRED FRAME 65 SHEAR CLIP IAW SRM 53-31-04.SDR SIMA20190218003Rib · crackedLEFT WING UPPER RIB 21 HAS A CRACK APPROXIMATELY 1/4" ON FLANGE. C/A-COMPLETED REPAIR TO LT WING RIB 21 IAW SRM 57-20-07.SDR SIMA20190217003Bracket · corrodedFRAME 65 CARGO DOOR CUTOUT LOWER SILL T BRACKET CORRODED. C/A-REMOVED AND REPLACED FRAME 65 CARGO DOOR CUTOUT LOWER SILL T BRACKET IAW SRM 51-40-02.SDR SIMA20190217005Profile · bentCARGO DOOR LOWER PROFILE IS BENT NEAR FORWARD ROLLER. C/A-REMOVED AND REPLACED CARGO DOOR LOWER PROFILE IAW SRM 51-40-02.SDR SIMA20190217004Door Sill · corrodedCARGO DOOR CUTOUT LOWER SILL CORRODED. C/A-REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER SILL IAW SRM 51-40-02.SDR RAIA201902221702Duct · blownLOSS OF PRESSURIZATION AT 34,000 FT. EMERGENCY DECENT. FOUND DUCT BLWN OFF OF PACK #1. REISTALLED COUPLEING ON DUCT FROM HEAT EXCHANGER TO CONDENSER MIXER. LEAK CHECK GOOD.SDR RAIA201902170001Warning System · false activationBAG DOOR INDICATION POST TAKE OFF. DEFERRED BAG DOOR INDICATION. MORE INFORMATION PROVIDED WHEN AVAILABLE. SUPPIMENTAL INFORMATION. PERFORMED OPS CHECK OF BAGGAGE DOOR WARNING. OPS CHECK GOOD.SDR ASOA2019021974006Light · inoperativeIAH - DURING MAINTENANCE INSPECTION THE R/H EMERGENCY OVERWING EXTERIOR LIGHT WAS FOUND TO BE INOP. MAINTENANCE REMOVED AND REPLACED THE AFFECTED LIGHT ASSEMBLY, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20190217002Light · inoperativeRT EXTERIOR OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED RT EXTERIOR OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD.SDR SIMA20190217001Charger · failedFOUND RT EMERGENCY OVER WING LIGHT INOP PER PS-2 CHECK. REMOVED AND REPLACED BATTERY CHARGER FOR BATTERY POWER SUPPLY 4 IAW AMM 33-50-04. OPS CHECK GOODSDR SIMA20190216004Structure · cracked#8 LT EMERGENCY LIGHT EXTRUSION IS CRACKED. C/A-COMPLETE:INSTALLED NEW EXTRUSION FOR #8 LT EMERGENCY FLOOR LIGHT IAW AMM 33-50-12.SDR ASOA2019022263016Acm · smokeTHE CREW REPORTED SMOKE/ODOR FROM #2 PACK. MAINTENANCE REPLACED THE #2 AIR CYCYLE MACHINE. OPERATIONAL CHECKS WERE GOOD.SDR SIMA20190216002Proximity Sensor · failedLG AIR GROUND FAIL IN AIR RETURN TO GATE. REMOVED & REPLACED LEFT MAIN GEAR FWD WOW PROXIMITY SWITCH, AND NOSE LANDING GEAR WOW PROXIMITY SWITCH IAW AMM 32-63-01. ACCOMPLISHED AMM LANDING GEAR PROX SWITCH ADJ/TEST IAW AMM 32-63-05, ACCOMPLISHED EXTENSION/ RETRSDR HNAA2019021800047Cable · defectiveAFTER T/O BAG DOOR OPEN INDICATION ON EICAS. RTF RAMP VERIFIED DOOR CLOSURE. R&R BAG DOOR CABLE REF AMM 52-32-00 OPS CK GOOD OK FOR SERVICE.SDR SIMA20190215004Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP. REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT BULB IAW AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECK GOOD.SDR SIMA20190215003Unknown · odorSTALE ODOR FROM PACK 1 DURING TAKEOFF AND IN CLOUDS DURING CRUISE. PERFORMED ETN-EM-72-034 ENG ODOR EVENT T/S. NO ODOR EVENT NOTED. PERFORMED OPS CHECK OF PACK 1 PER AMM 21-20-00. PACK 1 OPS CHECK GOOD.SDR ASOA201902167027Rib · crackedRT WING RIB 21 CRACKED. TRIMMED OUT DAMAGED AREA, FABRICATED AND INSTALLED DOUBLER AND FILLER. AIRCRAFT STILL IN C CHECK.SDR HNAA2019021500046Warning Message · illuminatedPDIS 631 30-10 1867981 14FEB19 PHL ASSGN
DURING A/I TEST IN FLIGHT, STAB A/I FAIL MSG
APPEARED ON EICAS.SDR HNAA2019021500045Relay · failedPDIS 631 30-10 1867972 13FEB19 PHL CLOSE
STAB A/ICE FAIL MESSAGE APPEARED ON EICAS. RAN QRH B
ROUGHT POWER LEVER UP INDICATION REMAINED ON.
FACT 13FEB19 18:06 PHL
FOLLOWED FIM TASK 30-12-00-810-803-A RNR K0552 RELAY
SDR SIMA20190213003Fuse · blownLT AND RT OVER WING EMERGENCY LIGHTS INOP. FOUND FUSE BLOWN ON #4 EMERGENCY BATTERY CHARGER. REMOVED AND REPLACED FUSE IAW CMM 25-60-03. OPS CHECK GOOD IAW AMM 33-50-00-700-801.SDR SIMA20190213001Gasket · damagedE1 A/ICE FAIL MSG CLIMBING FL180. DEFERRED AS PER MEL 30-11 AUTH 020470DM-C C/W M PROCEDURES. MEL REFERENCE CHANGED FROM 30-11 TO 30-12 PER MOC 801520. M PROCEDURES FOR 30-11 REVERSED. REMOVED AND REPLACED GASKET AND CLAMP ON E1 UPPER CHECK VALVE IAW AMM 36-1SDR SIMA20190213002Light · inoperativeEMERGENCY LIGHT OVER SERVICE DOOR INOP. REMOVED AND REPLACED EMERGENCY EXIT MARKING LIGHT. OPC GOOD IAW AMM 33-50-14.SDR HNAA2019021300043Terminal Block · burnedNDIS 603 30-41 0020580 09FEB19 CLT CLOSE
PLEASE FOLLOW UP WITH WIND SCREEN HEAT OPS CHECK FOR #2 W/S DUE TO OCCASIONAL OCCURANCES OF FAIL INDICATIONS THEN INSTANTLY CLEARING ITSELF AND OPERATING NORMALLY.
DFRL 09FEB19 10:53 CLT
SDR HNAA2019021300044Fan · failedPDIS 602 05-50 1874192 11FEB19 PGV CLOSE
ELECTRICAL SMELL/ODOR COMING FROM FLIGHT DECK CAPTAINS SIDE.
FACT 11FEB19 00:30 PGV
INSP SMELL IN FLT DECK FOUND NO OBVIOUS DEFECTS AT SUSPECT AREA OF FWD GLARESHILED. INSPECTED SUSPECT SDR HNAA201902112041Anti-Ice Valve · failedPDIS 631 30-10 1867951 11FEB19 ALB CLOSE
STAB ANTI ICE FAIL EICAS MESSAGE APPEARED DURING ANTI ICE PNEUMATIC TEST IN FLIGHT.
FACT 11FEB19 02:59 ALB REMOVED AND REPLACED H-STAB ANTI-ICE VALVE IAW EMB145AMM 30-12-01. OPS CHECK GOOD . OK FOR SSDR SIMA2019021108003Battery Pack · inoperativeRH AFT EXTERNAL OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED RH AFT EXTERNAL OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND EMB AMM 33-50-10-400-801-A. DID NOT FIX. SUSPECT #4 EMERGENCY BATTERY AND POWER SUPPLY BAD. REMOVED AND REPSDR SIMA2019021108001Pressure Switch · failedHIGH SPEED REJECT AT 122 KNOTS FOL EICAS PACK 2 OVLD MESSAGE POP UP AND STILL REMAINS ON EICAS WHILE PARKED BACK AT GATE-C/A-PACK 2 OVERLOAD ITEM DEFFERED. PERFORMED HIGH ENERGY STOP INSP PER AMM 05-50-16 NO DEFFECT NOTED. RAR OVERPRESSURE SWITCH IAW AMM 2SDR SIMA201902087001Pressure Switch · failedUNABLE TO PRESSURIZE ABOVE 10,000FT CAB ALT WENT TO 11,000FT-C/A-DEFERED AUTO AND MANUAL PRESSURIZATION M PROCEDURES C/W REF MEL 21-19 AUTH 020255DM-C. DURING T/S OF MEL 21-19 FOUND PBA PANEL SEAL TO BE TORN. COULD NOT PERFORM OPS CHECK DUE TO PACK 2 MEL. MEL SDR SIMA20190207007Aileron · excess playRIGHT HAND AILERON HAS PLAY AT THE ACTUATOR ATTACHMENT. THE SHIMMY DAMPER FITTING HAS TOOL MARKS. REPLACED RT AILERON WITH SERVICEABLE PART FROM STORES. FITTING P/N 145-6982-610SDR SIMA2019021107005Light · malfunctionedLH OVER-WING EMERGENCY LIGHT IS INOP.-C/A-COMPLIED WITH OPERATIONAL CHECK OF LH OVERWING EMERGENCY LIGHT. OPERATIONAL CHECK GOOD. NO DEFECT NOTED.SDR SIMA201902087002Lamp · inoperativeAISLE EMERGENCY LIGHT ROW 3 INOP-C/A-REMOVED AND REPLACED AISLE EMERGENCY LIGHT ROW 3 LAMP, OPC GOOD IAW EMB AMM 33-50-08SDR SIMA201902087004Lamp · inoperativeLH FWD OVER WING EMERGENCY LIGHT INOP-C/A-RAR LH FWD OVER WING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND EMB AMM 33-50-400-801-A. OPS CHECK GOOD. END.SDR SIMA2019021106004Door Sill · corrodedCARGO DOOR SILL IS CORRODED BETWEEN FRAMES 65-68. -C/A-REMOVED AND REPLACED CARGO DOOR SILL IAW SRM 51-41-02.SDR HNAA2019020800038Warning Message · false activationPDIS 602 30-10 1874141 06FEB19 SYR CLOSE
ICE COND-A/ICE MESSAGE APPEARED DURING TAKEOFF ROLL.
MSG EXTINGUISHED
FACT 06FEB19 16:56 SYR
PERFORMED ELECTRICAL RESET. OPS CHECKED A/ICE SYS IA
W AMM 30-00-00-700-SDR SIMA20190206001Battery Pack · dischargedUPON PS-1 INSPECTION CHECK PART 11-C FOUND EXTERNAL EMERGENCY LIGHT LT-RT TOP INOP. R&R BATTERY PACK AND BATTERY CHARGER ON NR 4 REF AMM 33-50-04. OPS CHECK GOOD. MEL ITEM RESTORED. BATTERY CHARGER ASSY P/N 11-0049 S/N 19285SDR SIMA20190206002Flashlight · inoperative18A FLASHLIGHT INOP. REMOVED AND REPLACED AFT FLASHLIGHT ASSY IAW MM 33-50-16. OPS CK GOOD.SDR HNAA2019020600036Inverter · faultyEMERGENCY LIGHTS INOP AT 1A AND 2A AT FLOOR. TROUBLESHOT AND FOUND GALLEY CEILING INVERTER PS 8501 TO BE AT FAULT. (SHORT SIGNED). R&R EMERGENCY LIGHTS INVERTER ASSY AS REQ. OPS CK GOOD.SDR SIMA20190205001Light · inoperativeFLOOR EMERGENCY PROX LIGHT STRIP BETWEEN SEATS 7 THROUGH 9 INOP. REMOVED AND REPLACED FLOOR EMERGENCY PROX LIGHTS STRIP BETWEEN SEATS 7 THROUGH 9 IAW AMM 33-50-12. OPS CHECK GOOD.SDR SIMA20190205003Light · inoperativeFWD CEILING EMERGENCY LIGHT INOP. R&R EMERGENCY LIGHT IAW AMM 33-50-08. OPC GOOD.SDR HNAA2019020600035Warning System · false activationABORTED T/O DUE TO HS 2 VLV MSG FLASHED AND SELF CLEARED. C/W QRH AND NO MSG NOTED.SDR SIMA20190204006Floor Support · corrodedSSI 53-20-11 LT OMEGA BEAM FLOOR SUPPORT CORRODED BETWEEN FR 58/59 (MARKED). C/A-COMPLETE:FURTHER INVESTIGATION OF CORROSION ON LT OMEGA BEAM FLOOR SUPPORT BETWEEN FR 58/59 SHOWS ADDITIONAL CORROSION THAT EXCEEDS THE REPAIR LIMITS OF EM-53MR-1518. SEE NRTC E69SDR SIMA20190204004Structure · damagedALL RT FLOOR SIDEWALL EXTRUSIONS ARE DAMAGED. C/A-COMPLETE:REMOVED AND REPLACED ALL RT FLOOR SIDEWALL EXTRUSIONS IAW AMM 33-50-12. SEE BOW313523 FOR INSTALLATION.SDR SIMA20190204005Floor Support · corrodedSSI 53-20-11 LT OMEGA BEAM CORRODED ON LOWER FLANGE AND WEB UNDER CROSSBEAM AT FR59. C/A-COMPLETE:COMPLIED WITH ERS-EM-53MR-3674 LT OMEGA BEAM CORROSION FRAME 58 -59 - PERMANENT REPAIR.
Back to Embraer EMB-145LR