Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA2018123100001Floor Support · corrodedCENTER OMEGA BEAM UPPER RH MATING FLANGE HAS CORROSION FROM FRAME 36 THRU 38- REMOVED CORROSION FROM CENTER OMEGA BEAM GUSSET FROM FR36 TO FR38, IT IS BEYOND ALLOWABLE LIMITS. .022" WAS REMOVED. R&R CENTER OMEGA BEAM GUSSET AT FR36-38.SDR ASOA201912303014Fitting · crackedDURING C CHECK INSPECTION FOUND CRACKED SHEAR CLIP AT FRAME 80 STRINGER 6L. MAINTENANCE REPLACED SHEAR CLIP AT FRAME 80.SDR ASOA201912303012Fitting · crackedDURING C CHECK INSPECTION FOUND SHEAR CLIP AT FRAME 80 RIGHT SIDE CRACKED. MAINTENANCE REPLACED SHEAR CLIP AT FRAME 80.SDR ASOA201912303010Fitting · crackedDURING C CHECK INSPECTION FOUND SHEAR CLIP AT FRAME 79 BETWEEN STRINGER 01L-03L CRACKED. MAINTENANCE REPLACED SHEAR CLIP.SDR SIMA201812310006Flashlight Assy · looseCABIN FLASHLIGHT IN FORWARD CABIN IS LOOSE.-C/A-R & R FLASHLIGHT BRACKET WORKS AS REQUIRED OPS CHECK IAW AMM 23-51-01. NO OTHER DEFECTS NOTED AT THIS TIME.SDR SIMA201812310003Proximity Switch · malfunctionedON TAXI IN, NOSEWHEEL STEERING DIDNT TURN THEN JUMPED FOR A SUDDEN TURN IN DESIRED DIRECTION W/ TILLER DEPRESSED. ON ANOTHER TURN, STEER INOP AFTER STARTING TURN W/ TILLER DEPRESSED. RELEASING AND DEPRESSING TILLER RESTORED STEERING.-C/A-RAR 7 DEGREE PROXIMITYSDR ASOA201912293002Holder · faultyTHE CREW REPORTED SMOKE IN LAV ABOVE SINK NEAR LIGHT FIXTURE. MAINTENANCE INSPECTED AND REPLACED LAV LIGHT HOLDER. OPERATIONAL CHECK WERE GOOD.SDR SIMA2018123129001Light · brokenTDMI 905T3354 PERFORME PERMANENT REPAIR OF RH OVERWING EMERGENCY LIGHT N/P BROKEN-C/A-RAR RH OVERWING EMEGENCY LIGHT ASSEMBLY IAW ERS-EM-33DF-024 AND EMB145 AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR SIMA20181228005Anti-Ice Valve · failedSUPPLEMENTAL ENG A/I FAIL IN FLIGHT (EMERGENCY NOT DECLARED). FLT CONT. C/A-DEFERRED E1 A/I VLV M PROCEDURES C/W REF MEL 30-11AUTH 121065DM-C. REMOVED AND REPLACEDEN E1 ANTI-ICE VALVE IAW AMM 30-21-01 OPS CHECK GOOD MEL RESTORED.SDR HNAA201812310032Flashlight · odorPDIS 659 25-60 1868881 28DEC18 PHL CLOSE
COCKPIT FLASHLIGHT ASSY HAS A HOT ELECTRICAL SMELL.
FACT 28DEC18 08:28 PHL
REPLACED FLASHLIGHT ASSY IN COCKPIT. OPS CHECK GOOD.
OK FOR SERVICESDR HNAA2018123100331Warning Message · false activationPDIS 604 36-21 1913091 28DEC18 PHL CLOSE
BLEED ONE LEAK MESSAGE AND INSCRIPTION DISPLAYED CAP
T RAN QRH MESSAGE EXTINGUISHED. (ADDED: EICAS MESSAG
E AND LEAK INSCRIPTION DISPLAYED) 28573 00 JBU
FACT 28DEC18 04:57 PHL
SDR SIMA2018123128002Battery Pack · unsecureLH AND RH OVERWING EXIT AREA EMERGENGY LIGHTS INOP-C/A-REMOVED FLOOR BOARD PANEL FOUND BATTERY PACK NOT INSTALLED. INSTALLED AND SECURED BATTERY PACK TO HOLDER AND REINSTALLED FLOOR BOARD IAW EMB 145 AMM 33-50-04 STEPS 4,I,4,B. 5,I(1,2,3). J,3,B. 6. OPC CHECK SDR SIMA2018123128001Light · brokenTDMI 905T3354 C/W REINSP OF RH OVERWING EMERGENCY LIGHT N/P BROKEN PER ERS-EM-33DF-024 PTB-C/A-PERFORMED GVI OF SPEED TAPE ON RH OVERWING EMERGENCY LIGHT IAW ERS-EM-33DF-024 NO DEFECTS NOTED TDMI REMAINS OPENSDR RAIA2018122870002Floor Support · corrodedCARGO BAY L/H AFT SILL FROME FRAMES 69-71 HAS CORROSION....REMOVED AND REPLACED CARGO L/H SILL AT FR 69-71.SDR RAIA2018122870001Floor Support · corrodedCARGO BAY R/H SILL AT FRAMES 65-68 HAS CORROSION....REMOVED AND REPLACED R/H CARGO SILL AT FR 65-68.SDR SIMA20181227001Light · abnormalTRANSFER FROM LOG PG 4294014 ITEM #1 EMERGENCY LIGHTS FLICKERING + GALLEY LIGHTS WOULD NOT OFF IN FLIGHT ACCORDING TO FA-C/A-PERFORMED OPERATIONAL CHECK OF EMERGENCY LIGHTS IAW AMM 33-50-00. OPS CHECK GOOD. PERFORMED OPERATIONAL CHECK OF GALLEY LIGHT IAW AMM 3SDR SIMA20181226003Pitot Line · contaminatedRECEIVED "IAS" COMPARED MSG ON AIRSPEED TAPES. AIRSPEED NR 1 MATCHED STANDBY AIRSPEED. AIRSPEED NR 2 FO SIDE WAS 8 KNOTS LOW REFERENCE ITEM 1 OF THIS AML. WATER FOUND IN BOTH PITOT 1 AND 2 DRAIN LINES. DRAINED WATER FROM PITOT SYSTEM IAW AMM 34-13-00 PERFORMEDSDR RAIA2018122960004Support Angle · crackedL/H WING I/B UPPER SURFACE AT L/E BELLY FAIRING NUTPLATE SUPPORT ANGLE AT FR 39 IS CRACKED....REMOVED & REPLACED SUPPOT ANGLE AT FR 39.SDR HNAA2018122800330Sensor · malfunctionedDISCREPANCY: BRAKE HOT INDICATION AFTER T/O, EXTINGUISH AFTERLANDING
ACTION TAKEN: MX ISOLATED TO #3 BRAKE TEMP SENSOR, R&R'D #3 BRAKE TEMP SENSOR IAW AMM 32-47-01.SDR SIMA201812276002Light · inoperativeROW 12 CEILING EMERGENCY LT INOP-C/A-RAR ROW 12 CEILING EMERGENCY LT IAW 33-50-08-000-801-A AND 33-50-08-400-801-A OPS CHECK GOOD ENDSDR ASOA201812277191Skin · gougedGOUGE AT FRAME 51, STRINGER 19R (193 AREA). REPLACED REPAIR DOUBLER IN ACCORDANCE WITH SRM 53-24-02. AIRCRAFT IS STILL IN MAINTENANCE.SDR HNAA2019010400006Skin · corrodedNDIS 621 53-30 0009070 03JAN19 SBY CLOSE FOUND CORROSION AT F24 & STR. 194. DOESNOT EXTEND OUT OF CHEM MILLED AREA. (SEE SEQ. 4 FOR DETAILS) FACT 03JAN19 12:46 SBY REMOVED ATTACHMETN RIVETS FROM STRINGER 19R AND REMOVED FRAME LEGS OF FR24 & 25 AT STR 19R. INSTSDR HNAA2019010400005Rivet · missingNDIS 621 53-30 0009060 03JAN19 SBY CLOSE FOUND 1 RIVET MISSING & 1 RIVET POPPED AT F24 XSTR 19R. FACT 03JAN19 12:34 SBY REMOVED ATTACDHMENT RIVETS FROM STRINGER 19R AND REMOVED FRAME LEGS OF FR 24 & 25 AT STR 19R. INSTALLED FRAME LEGS FOR FR24 & 25 AND SKIN RISDR SIMA201812264003Lamp · inoperativeROW 12 CEILING EMERGENCY LIGHT INOP-C/A-RAR ROW 12 CEILING EMERGENCY LAMP IAW EMB AMM TASK# 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. ENDSDR HNAA2018122600329Sign · inoperativeEMERGENCY EXIT SIGN ABOVE FWD FA'S SEAT INOP. RESET EMERGENCY LIGHT C/B, OPS CHECK FOR EMERGENCY SIGN ABOVE FWD F/A'S SEAT IS GOOD.SDR HNAA2018122600328Light · inoperativeNDIS 642 33-51 0002280 24DEC18 SBY CLOSE
EMEGENCY LIGHT IN FRONT OF ROW 3 INOP
FACT 24DEC18 09:44 SBY
R&R EMERGENCY LIGHT IN FRONT OF ROW 3, SECURED WITH
RETAINED HARDWARSDR SIMA20181223003Anti-Ice Valve · faultyPNEUMATIC A/I TEST FAIL ON GROUND. WING A/I FAIL EICAS MSG ON BOTH 1 & 2 ON MULTIPLE ATTEMPTS. C/A-T/S PER FIM TASK 30-11-00-810-805. RAR WING ANTI ICING ASSYMETRY PRESS TRANS IAW AMM 30-11-13-000-801-A & 30-11-13-400-801-A. OPC GOOD AND FOUND ACCESS PANEL 192SDR RAIA2018122830001Floor Support · corrodedL/H OMEGA BEAM UPPER DIGITAL SUPPORT HAVE CORROSION FROM FRAME 20 THRU 23....REMOVED AND REPLACED L/H OMEGA BEAM UPPER DIGITAL SUPPORT AT FRAME 20 THRU 23.SDR RAIA201812210008Doubler · corrodedRT LOWER PARTITION DOUBLER AT FRAME 61 IS CORRODED. REMOVED AND REPLACED RT LOWER DOUBLER AT FRAME 61 THIS IS AN UPDATE PUT WRONG CONTROL NUMBER USED RAIA201812210001 NOW IS RAIA201812210008.SDR SIMA201812281004Unknown · odorSTRONG BURNING / MILDEW MOLDY SMELL DURING VECTORS TO APPROACH AND LAND. OCCURRED AFTER MODERATE TURB DURING DESENT. WITH CONSTANT AND CONTINUOUS THRUST LEVER MOVEMENTS.AIRCRAFT REQUIRES INSPECTION FOR FERRYFLIGHT. REFERENCE LOG PAGE 4445943 ITEM-C/A-THIS AIRCSDR SIMA201812241003Hydraulic System · leakingINBND MIA DECLARED EMRGENCY FOR BURNING OIL SMELL. LNDD SAFELY.IN REFERENCE TO LG PG 4445943 ITEM 1 STRONG BURNING SMELL, FOUND EVIDENCE OF A POSSIBLE EXTERNAL HYDRAULIC LEAK DOWN THE BOTTOM OF THE FUSELAGE LEADING TO THE APU.CHECK GALLEY ARE FOR EVIDENCE OF SSDR HNAA2018122100327Bulb · malfunctionedR/H FWD FUSELAGE EMERGENCY LIGHT DIM. R/R BULB IAW AMM 33-50-10-400-801-ASDR HNAA2018122100326Bulb · inoperativeMAIN DOOR EMERGENCY LIGHT INOP. R&R LIGHT BULBSDR HNAA2018122100325Warning Message · illuminatedEICAS MESSAGE ON CLIMB OUT...AIRCRAFT CURRENTLY DOWN IN PHL FOR REPAIRSSDR RAIA201812190004Door Sill · corrodedRT SILL FROM FRAMES 58-61 HAS CORROSION. REMOVED AND REPLACED RT SILL FROM FRAMES 58-61.SDR RAIA201812190003Door Sill · corrodedLT SILL FROM FRAMES 58-61 HAS CORROSION. REMOVED AND REPLACED LT SILL FROM FRAMES 58-61.SDR RAIA201812180009Gusset · corrodedCENTER GUSSET AT FRAMES 58-61 HAS CORROSION. REMOVED AND REPLACED CENTER GUSSET AT FRAMES 58-61.SDR RAIA201812180008Gusset · corrodedLT GUSSET AE FRAMES 58-61 HAS CORROSION. REMOVED AND REPLACED L/H GUSSET AT FRAMES 58-61.SDR RAIA201812180007Gusset · corrodedRT GUSSET AT FRAMES 58-61 HAS CORROSION. REMOVED AND REPLACED RT GUSSET AT FRAMES 58-61.SDR ASOA2018122685354Battery Pack · inoperativeDURING MX INSPECTION THE FORWARD CABIN EMERGENCY LIGHT WERE DISCOVERED INOP. MX REMOVED AND REPLACED THE #1 EMERGENCY LIGHT BATTERY PACK WITH OPERATIONAL CHECK GOOD. A/C WAS RELEASED FOR RETURN TO SERVICE.SDR ASOA2018122685352Battery Pack · inoperativePILOT REPORTED EMERGENCY LIGHTS INOP FROM ROW 7 AND AFT.MX REMOVED AND REPLACED #1, #3, AND #4 EMERGENCY BATTERIES WITH OPS CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20181218002Light · inoperativeAFT CEILING EMERGENCY LIGHT INOP. REMOVED AND REPLACED AFT CEILING EMERGENCY LIGHT BULB IAW AMM 33-50-10, OPS CHECK GOOD.SDR RAIA2018122217001Floor Support · corrodedCENTER OMEGA BEAM UPPER GUSSET HAVE CORROSION FROM FRAME 30 THRU 36....REMOVED AND REPLACED CENTER OMEGA BEAM UPPER GUSSET AT FRAME 30 THRU 36SDR SIMA201812187001Seal · leakingRAPID DECOMPRESSION @ FL < CABIN ALT SHOWED AND MASTER WARNING SOUNDED> O@ MASKS DEPLOYED FA NOTED SQUEALING NOISE FROM SERVICE DOOR.-C/A-DEFERRED PRESSURIZATION SYSTEM. M PROCEDURES C/W. REMOVED AND REPLACED PAX O2 GENERATORS AND MASKS IAW AMM 35-20-01. REMOSDR SIMA201812187003Light · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH OVERWING EMERGENCY LIGHT IAW EMB AMM 33-50-10 OPS CHECK GOODSDR RAIA2018122816001Floor Support · crackedFLOOR SUPPORT IS CRACKED AT FRAME 52 BETWEEN CENTER AND R/H OMEGA BEAM....REMOVED AND REPLACED FLOOR SUPPORT AT FRAME 52 BETWEEN CENTER AND R/H OMEGA BEAM.SDR HNAA2018121800323Battery · not seatedDIS 654 33-51 0003990 16DEC18 SBY CLOSE
EMERGENCY LIGHT ABOVE F/A SEAT INOP
31253 00 BAD
FACT 16DEC18 10:20 SBY
RESEATED #1 BATTERY BEHIND COAT CLOSET. RESECURED
PANELSSDR HNAA2018121800320Clamp · loosePDIS 657 21-11 1915522 16DEC18 PHL CLOSE
AFTER TAKEOFF BLD 1 LEAK EICAS MSG ALONG WITH RED INSCRIPTION ON BLEED SWITCH. AFTER QRH, MESSAGES EXTINGUISHED. HISTORY: YES
FACT 16DEC18 14:35 PHL
INSPECTED ENGINE 1 BLEED VALVE AND FSDR HNAA2018121800317Wire · brokenMDIS 602 33-51 1978093 16DEC18 CLT ASSGN
EMERGENCY LIGHT AT AFT GALLEY WALL HAS BROKEN WIRE A
T SPLICE.
26390 00 DS
HISTORY: .
DFRL 16DEC18 13:40 CLT
INSTALLED TSDR HNAA2019010400008Door Sill · corrodedDISCREPANCY: DURING HVY CHK MAINTENANCE FOUND SERVICE DOOR CENTER SILL CORRODED AROUND FWD AND AFT NUTPLATE HOLES. ACTION TAKEN: RAR SERVICE DOOR CENTER SILL IAW SRM 51-40-02.