SDR HNAA2019010400007Floor Support · corrodedDISCREPANCY: DURING HVY CHK MAINTENANCE FOUND LT NR 1 OMEGA BEAM REPAIR AT FR 20 CORRODED. ACTION TAKEN: REPLACED LT NR 1 OMEGA BEAM REPAIR AT FR 20 IAW SRM 53-00-10.Dec 15, 2018 · N637AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA2018122015003Fitting · missingRH AILERON PCA FITTING MISSING 2EA BUSHINGS-C/A-REMOVED AND REPLACED PCA FITTING ASSEMBLY IAW EO EM-27MR-112.Dec 15, 2018 · N942LL · Emb EMB145LR · AileronsSDR HNAA2018121800324Wire · disconnectedNDIS 641 33-51 0020380 15DEC18 SBY CLOSE EMERGENCY LIGHT UNDER MAIN DOOR HINGE IS INOP 34166 00 CRH FACT 15DEC18 09:34 SBY FOUND WIRES FOR THE EMERGENCY LIGHT DICONNECTED AT T Dec 15, 2018 · N641AE · Emb EMB145LR · Light System WiringSDR HNAA2018121800319Battery Pack · inoperativeMDIS 602 33-51 1978082 15DEC18 CLT CLOSE L/H AND R/H EXTERIOR OVERWING EMERGENCY LIGHTS INOP FACT 16DEC18 11:56 CLT R\R EMERGENCY BATTERY PACK AT ROW 15A OPS CHECK GOOD , OK FOR SERVICE. CLEAR MEL.Dec 15, 2018 · N602AE · Emb EMB145LR · Emergency LightingSDR HNAA2018121800318Filter · not reportedPDIS 640 30-14 1858621 15DEC18 PHL CLOSE SHORTLY AFTER TAKEOFF ICE COND - A/I INOP EICAS MSG, FOLLOWED BY BLD 1 OVTEMP. 26905 00 DS FACT 15DEC18 16:34 PHL RNR FAN AIR VALVE FILTER IDec 15, 2018 · N640AE · Emb EMB145LR · Pneumatic Distribution SystemSDR ASOA201812185472Skin · dentedIAH - DURING MAINTENANCE INSPECTION THREE SMALL DENTS WERE FOUND ON THE R/H FUSELAGE SKIN JUST BELOW THE FIRST OFFICERS' DV WINDOW. MAINTENANCE RECONTOURED TWO DENTS AND PERFORMED A DOUBLER REPAIR ON THE MIDDLE DENT. ALL OPERATIONAL / PRESSURIZATION CHECKS WERDec 15, 2018 · N16976 · Emb EMB145LR · Fuselage Main, Plate/SkinSDR RAIA2018122214001Floor Support · corrodedL/H FLOOR SILL SPLICE BETWEEN FR 23 & 24 IS CRACKED....REMOVED AND REPLACED L/H FLOOR SILL SPLICE AT FR 23 & 24Dec 14, 2018 · N844HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20181214003Support Angle · crackedRT WING TORQUE BOX NR 1, L SUPPORT ANGLE IS CRACKED. REPLACED SUPPORT ANGLE IAW SRM 51-40-02.Dec 14, 2018 · N942LL · Emb EMB145LR · Wing Miscellaneous StructureSDR HNAA2018121800322Connector · damagedDISCREPANCY: CEILING PANEL EMERGENCY LIGHT (AFT) AT EMERGENCY EXIT ROW DOES NOT ILLUMINATE. ACTION TAKEN: R&R CONNECTORS ON WIRE ENDS. OPS CHECK GOODDec 14, 2018 · N649PP · Emb EMB145LR · Light System WiringSDR HNAA2018121800321Lamp · inoperativeNDIS 640 33-51 0021060 14DEC18 RIC CLOSE EMERGENCY LIGHT ON MAIN DOOR ENTRANCE CEILING DOES NOT ILLUMINATE FACT 14DEC18 06:58 RIC R&R MAIN DOOR ENTRANCE EMERGENCY CEILING LIGHT LAMP IDec 14, 2018 · N640AE · Emb EMB145LR · Emergency LightingSDR 4VAA20181213009Contactor · overheatedCREW REPORTED LEFT WINDSHIELD HEAT WAS INOPERATIVE AND FOGGING UP. MAINTENANCE FOUND WINDSHIELD HEAT FUSE 100FU01-080 FAILED (OPEN), THIS WAS CAUSED BY THE OVERHEATING OF HEAT CONTROL CONTACTOR 480CC01. THE CONTACTOR TERMINAL “A” HAD OVERHEATED CAUSING MELTINGDec 13, 2018 · N824HK · Emb EMB145LR · Windshield/Door Rain/Ice RemovalSDR SIMA2018121413003Oxygen Mask · disconnectedOBSERVER MASK LEAKING O2 IN FLIGHT. CREW O2 840 PSI AT 23 C -C/A-INSPECTED FOUND TO BE OBSERVER OXYGEN MASK DISCONNECTED MASK AND RESTOWED REF 4389396 ITEM 1. SERVICED CREW O2 IAW EMB 145 AMM 12-14-00 OK FOR SERVICEDec 13, 2018 · N697AB · Emb EMB145LR · Crew Oxygen SystemSDR SIMA2018121712010Unknown · odorON DESCENT AT FLIGHT IDLE, MUSKY SMELL / ODOR FOR ABOUT A MINUTE, WENT AWAY WHEN TAKEN OUT OF IDLE. NO NOTICE OF SMELL AFTER LANDING / TAXI. TRANSFERED TO NRWC # 676-MIA-03291.-C/A-PERFORMED INSPECTION OF L/H AND R/H ENGINES IAW RRMM 72-00-00-200-802. PERFORMDec 12, 2018 · N676AE · Emb EMB145LR · Air Distribution SystemSDR SIMA2018121412009Seal · damagedF/A HAVING DIFFICULTY CLOSING AND UNABLE TO OPEN DOOR W/O ASSISTANCE FROM THE AGENT ON THE BRIDGE-C/A-FOUND MAIN PAX DOOR FRAME SEAL DAMAGED AND INHIBITING PROPER OPERATION OF THE MAIN PAX DOOR. RAR MAIN PAX DOOR FRAME SEAL IAW EMB 145 AMM 53-21-01. PRESSURIZADec 12, 2018 · N902BC · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA2018121412006Cradle · brokenFWD CABIN FLASHLIGHT CRADLE BROKEN-C/A-RAR FWD CABIN FLASHLIGHT CRADLE IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A..NO FURTHER DEFECTS NOTED AT THIS TIME END.Dec 12, 2018 · N694AE · Emb EMB145LR · Emergency EquipmentSDR SIMA2018121412005Charger · failedDURING EMERGENCY LIGHT OPC FOUND EMERGENCY LIGHT FWD OF RH WING, SERVICE DOOR LIGHTING AND FLOOR EMERGENCY LIGHT STRIPS 1A-6A INOP.-C/A-TROUBLE SHOT. FOUND #2 EPSU INOP. REMOVED AND REPLACED #2 EMERGENCY LIGHT POWER SUPPLY AND CHARGER IAW ENVOY W/C 33-700-19. Dec 12, 2018 · N680AE · Emb EMB145LR · Emergency LightingSDR SIMA2018121412007Unknown · odorON DESCENT AT FLIGHT IDLE, MUSKY SMELL / ODOR FOR ABOUT A MINUTE, WENT AWAY WHEN TAKEN OUT OF IDLE. NO NOTICE OF SMELL AFTER LANDING / TAXI. TRANSFERED TO NRWC # 676-MIA-03291.-C/A-PERFORMED INSPECTION OF L/H AND R/H ENGINES IAW RRMM 72-00-00-200-802. PERFORMDec 12, 2018 · N676AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20181212001Outflow Valve · malfunctionedA/C DID NOT PRESSURIZATION / PRESSURIZE. RETURNED TO DFW. NO EICAS ALERTS, LANDED AT APPROX 39,000 LBS. DEFERRED AUTOMATIC PRESSURIZATION MODE .C/W MAINT ACTION. PERFORMED MANUAL PRESSURIZATION & FOUND WORKING PROPERLY IAW MM 21-31-00. C/W "M" PROCEDURES AND Dec 12, 2018 · N918AE · Emb EMB145LR · Cabin Pressure Control SystemSDR SIMA20181212004Gcu · failedGEN1-4 OFF BUS EICAS MESSAGE DISPLAYED INTERMITTENTLY THEN RETURNED TO GEN 1 OFF BUS WHICH IS NORMAL CONDITION DUE TO CURRENT MEL. REMOVED AND REPLACED NR 4 GCU IAW AMM 24-31-02. OPS CHECK GOOD.Dec 12, 2018 · N623AE · Emb EMB145LR · AC RegulatorSDR SIMA20181212003Not Reported · malfunctionedAIRCRAFT WOULD NOT PRESSURIZE AFTER TAKE OFF. ON DESCENT COMING THROUGH 10,000 FEET AIRCRAFT APPEARED TO BEGIN PRESSURIZING NORMALLY. PERFORMED FUNCTIONAL TEST OF PRESSURIZATION CONTROL SYSTEM IN AUTOMATIC MODE IAW AMM 21-31-00-700-802-A. FUNCTIONAL TEST GOODDec 12, 2018 · N612AE · Emb EMB145LR · Cabin Pressure Control SystemSDR RAIA201812110023Floor Support · corrodedAT FRAMES 71-73 RT FLOOR SUPPORT HAS CORROSION. REMOVED AND REPLACED RT FLOOR SUPPORT AT FRAMES 71-73.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110022Floor Support · corrodedLT OMEGA BEAM FROM FRAMES 53-58 HAS SIGNS OF CORROSION. REMOVED AND REPLACED LT OMEGA BEAM FROM FRAMES 53-58.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110021Support · corrodedLT CROSS SUPPORT AT FRAME 39 HAS SIGNS OF CORROSION. REMOVED AND REPLACED LT CROSS SUPPORT AT FRAME 39.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110020Gusset · corrodedLT GUSSET FROM FRAMES 53-58 HAS SIGNS OF CORROSION. REMOVED AND REPLACED LT GUSSET FROM FRAMES 53-58.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110019Floor Support · corrodedCENTER OMEGA BEAM FROM FRAMES 35-38 HAS CORROSION. REMOVED AND REPLACED CENTER OMEGA BEAM FROM FRAMES 35-38.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110018Fitting · crackedRT SHEAR CLIP AT FRAME 26 STRINGER 15R AND 16R IS CRACKED. REMOVED AND REPLACED SHEAR CLIP AT FRAME 26 STRINGER 15R AND 16R.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110017Gusset · corrodedCENTER GUSSET FROM FRAMES 53-58 HAS CORROSION. REMOVED AND REPLACED CENTER GUSSET FROM FRAMES 53-58.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110016Door Sill · corrodedLT SILL FROM FRAMES 53-58 HAS CORROSION. REMOVED AND REPLACED LT SILL FROM FRAMES 53-58.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110015Door Sill · corrodedLT SILL FROM FRAMES 41-48 HAS CORROSION. REMOVED AND REPLACED LT SILL FROM FRAMES 41-48.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110014Gusset · corrodedLT GUSSETT FROM FRAMES 35-38 HAS CORROSION. REMOVED AND REPLACED L/H GUSSETT FROM FRAMES 35-38.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110013Door Sill · corrodedLT SILL FROM FRAMES 35-41 HAS CORROSION. REMOVED AND REPLACED LT SILL FROM FRAMES 35-41.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110012Door Sill · corrodedRT SILL FROM FRAMES53-58 HAS CORROSION. REMOVED AND REPLACED SILL FROM FRAMES 53-58.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110011Gusset · corrodedLT GUSSETT FROM FRAMES 38-45 HAS CORROSION. REMOVED AND REPLACED LT GUSSETT FROM FRAMES 38-45.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110010Door Sill · corrodedRT SILL FROM FRAMES 29-35 HAS SIGNS OF CORROSION. REMOVED AND REPLACED RT SILL FROM FRAMES 29-35.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110009Floor Support · corrodedLT OMEGA BEAM FROM FRAMES 38-45 HAS CORROSION. REMOVED AND REPLACED LT OMEGA BEAM AT FRAMES 38-45.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110008Door Sill · corrodedLT FLOOR SILL AT FRAMES 61-65 HAS CORROSION. REMOVED AND REPLACED LT FLOOR SILL AT FRAMES 61-65.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110007Floor Support · corrodedAT FRAME 65-68R FLOOR SUPPORT HAS CORROSION. REMOVED AND REPLACE RT FLOOR SUPPORT AT FRAME 65-68.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110006Floor Support · corrodedAT FRAME 68-71 RT FLOOR SUPPORT HAS CORROSION. REMOVED AND REPLACED R/H FLOOR SUPPORT AT FRAMES 68-71.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110005Floor Support · corrodedAT FRAME 61-65 O/B OMEGA BEAM HAS CORROSION. REMOVED AND REPLACED O/B OMEGA BEAM ASSY AT FRAME 61-65.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110004Door Sill · corrodedRT FLOOR SILL AT FRAMES 61-65 HAS CORROSION. REMOVED AND REPLACED RT FLOOR SILL AT FRAMES 61-65.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110003Floor Support · corrodedCENTER OMEGA BEAM AT FRAME 61-71 HAS CORROSION. REMOVED AND REPLACED CENTER OMEGA BEAM ASSY AT FRAME 61-71.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110002Gusset · corrodedCENTER GUSSET FROM FRAMES 35-38 HAS CORROSION. REMOVED AND REPLACED CENTER GUSSET FROM FRAMES 35-38.Dec 11, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201812110001Channel · crackedCARGO DOOR TORSION ROD SUPPORT HAT CHANNEL IS CRACKED AT FRAME 61. REMOVED AND REPLACED CARGO DOOR ROD SUPPORT HAT CHANNEL.Dec 11, 2018 · N847HK · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA20181211008Smoke Detector · failedBAGGAGE COMPARTMENT SMOKE EICAS MESSAGE DOES NOT POST DURING FIRE TEST. CARGO FIRE PUSHBUTTON WILL NOT ILLUMINATE DURING FIRE TEST. INSPECTED SMOKE DETECTORS AND PERFORMED OPS CHECK OF SYSTEM IAW AMM 26-15-00 TEST FAILED MEL 26-03 REMAINS OPEN A/C OK FOR SERVIDec 11, 2018 · N663AR · Emb EMB145LR · Smoke DetectionSDR HNAA2018121200314Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOP. REMOVED THE MAIN DOOR EMERGENCY LIGHT COVER IAW AMM TASK #25-23-04-000-801-A. REMOVED THE EMERGENCY LIGHT ASSEMBLY FROM THE MAIN DOOR EMERGENCY LIGHT COVER AND REPLACED WITH NEW ASSEMBLY AND RETAINED HARDWARE INSTALLED MAIN DOORDec 11, 2018 · N625AE · Emb EMB145LR · Emergency LightingSDR SIMA2018121211006Battery · failed12C UPPER EMERGENCY EXIT SIGN INOP-C/A-T/S PER WM 33-50-50 REMOVED AND REPLACED #3 EMERGENCY BATTERY AND CHARGER IAW W/C 33-700-19 NO FIX, FURTHER T/S RAR #5 INVERTER IAW EMB AMM 33-50-11-000-801-A AND 33-50-11-400-801-A OPC GOOD NO DEFECTS NOTED AT THIS TIME Dec 11, 2018 · N678AE · Emb EMB145LR · Emergency LightingSDR SIMA2018121211005Light · inoperativeCOCKPIT EMERGENCY LT INOP-C/A-RAR COCKPIT EMERGENCY LIGHT IAW EMB AMM 33-50-05-000-801-A AND 33-50-05-400-801-A. NO FURTHER DISCREPANCIES WERE FOUND. END.Dec 11, 2018 · N678AE · Emb EMB145LR · Emergency LightingSDR SIMA2018121211004Bulb · inoperativeMAIN ENTRANCE DOOR EMERGENCY FLOOD LIGHT INOP-C/A-REMOVED AND REPLACED MAIN ENTRANCE DOOR EMERGENCY FLOOD LIGHT BULB IAW EMB 145 AMM 33-50-10. OPS CHECK GOODDec 11, 2018 · N649PP · Emb EMB145LR · Emergency LightingSDR SIMA20181211001Screw · missingPASSENGER DOOR HARD TO OPEN AND SCREWS MISSING FROM PANELING.-C/A-REPLACED SCREWS AS REQUIRED AND OPS CHECKED PAX DOOR REF. AMM 52-10-01. OPS CHECK GOOD.Dec 11, 2018 · N900AE · Emb EMB145LR · Passenger/Crew DoorsSDR RAIA201812100045Threshold · corrodedSERVICE DOOR THRESHOLD PLATE IS CORRODED. REMOVED AND REPLACED SERVICE DOOR THRESHOLD PLATE.Dec 10, 2018 · N847HK · Emb EMB145LR · Fuselage Miscellaneous Structure
Back to Embraer EMB-145LR