Service difficulty report · Contactor · Emb EMB145LR

Difficulty date
December 13, 2018
Submitted
January 3, 2019
Operation
Air carrier
Aircraft
N824HK
Make and model
Emb EMB145LR
Aircraft serial
145498
Aircraft time
36,665 hours, 30,311 cycles
Part
Contactor
Part number
480CC01
Part serial
8674
Condition
Overheated
Location
Window Heat
Stage of operation
DE
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED LEFT WINDSHIELD HEAT WAS INOPERATIVE AND FOGGING UP. MAINTENANCE FOUND WINDSHIELD HEAT FUSE 100FU01-080 FAILED (OPEN), THIS WAS CAUSED BY THE OVERHEATING OF HEAT CONTROL CONTACTOR 480CC01. THE CONTACTOR TERMINAL “A” HAD OVERHEATED CAUSING MELTING OF WIRE INSULATION AND DAMAGING THE TERMINAL (SEE PHOTO). THE CREW DID NOT REPORT ANY BURNING OR UNUSUAL ODORS IN THE COCKPIT. THE CONTACTOR AND FUSE WERE REPLACED AND SYSTEM OPERATIONAL CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.