SDR HNAA2018103100269Light · out of positionNDIS 907 33-20 0004610 28OCT18 RIC CLOSE ROW 13 FLOOR PROXIMITY LIGHT PULLED OUT OF HOLDER 27625 00 NGR FACT 28OCT18 10:29 RIC R/R FLOOR PROXIMITY LIGHT AT ROW 13 IN REF TO AMM 33-50-12-000/400-801-A. OK FOR SERVICE.SDR SIMA2018110527002Door Frame · corrodedFWD LOWER CORNER OF AFT CARGO DOOR CUTOUT HAS CORROSION.-C/A-REMOVED AND REPLACE D CARGO DOOR SILL IAW SRM 51-40-02.SDR ASOA201810255287Unknown · smokeFLIGHT 4137 YHZ-EWR CREW REPORTED LAV SMOKE ON CLIMBOUT. SMOKE IN CABIN. A/C RETURNED TO YHZ AND LANDED SAFELY. CONTRACT MX PERFORMED ABNORMAL SMELL INSPECTION WITH NO DEFECTS NOTED. RAN ENGINE WITH CREW COULD NOT DUPLICATE FAULT. A/C OK FOR SERVICE.SDR SIMA2018102925001Control Lever · failedDURING GEAR RETRACTION NOISE SIMILAR TO GEAR DOORS OPEN- NORMAL EICAS INDICATIONS DURING RETRACTION + EXTENSION-C/A-TROUBLESHOT IAW FIM TASK 32-32-00. REMOVED AND REPLACED LANDING GEAR CONTROL LEVER IAW AMM TASK 32-32-02. NO DISCREPANCIES FOUND OPS CHECK GOOD.SDR HNAA2018102600268Door Sill · corrodedCARGO ENTRANCE SILL CORRODED. CLASSIFIED AS LEVEL 1 CORROSION PER MP&P SECTION 5.11.17 FIGURE 3. R&R CARGO ENTRANCE SILL IAW SRM 51-40-02.SDR RAIA2018110624001Structure · corrodedSTRUCTURE ON TOP OF LAV CUP HAS CORROSION................REMOVED AND REPLACED STRUCTURE ON TOP OF LAV CUPSDR SIMA2018110524001Support Bracket · crackedSUPPORT BRACKET FOR CARGO DOOR TORSION BAR/CABLE DRUM BETWEEN FRAMES 67-68 HAS 1/4 " CRACK -C/A-REMOVED AND REPLACED SUPPORT BRACKET FOR CARGO DOOR TORSION BAR/CABLE DRUM BETWEEN FRAMES 67-68 IAW SRM 51-40-02.SDR ASOA201810237174Wire · brokenFLOOR PROXIMITY STRIP HAS BROKEN WIRES AT FRAME 46. REPAIRED FLOOR PROXIMITY STRIP WIRES AT FRAME 46 IN ACCORDANCE WITH SWPM 20-21-00.SDR SIMA201810232001Computer · failedSTALL PROTECTION TEST LIGHT STAYS ILLUMINATED AFTER TEST. NO AURAL WARNING DURING TEST. C/A-FOUND CMC MESSAGE SPC FAIL. REPLACED STALL PROTECTION COMPUTER IAW AMM 27-36-02-000-801-A & 27-36-02-400-801-A. OPERATIONAL TEST IAW WORK CARD 27-700-20 GOOD. NO FURTHESDR 4VAA201810221006Unknown · odorWHILE ON SHORT FINAL TO KAUS, THE FLIGHT DECK CREW AND FORWARD FLIGHT ATTENDANT REPORTED AN ELECTRICAL BURNING ODOR. AIRCRAFT CONTINUED APPROACH AND LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED CHECKS IAW FIM 21-20-00 AND 25-31-00 TASK AND INSPECTED GALLEY ASDR SIMA2018102220003Flashlight · inoperativeCOCKPIT FLASHLIGHT INOP. C/A-REMOVED AND REPLACED COCKPIT FLASHLIGHT IAW AMM 33-50-16 OPS CHECK GOOD.SDR SIMA2018102220002Flashlight · inoperativeAFT CABIN FLASHLIGHT INOP. C/A-REMOVED AND REPLACED AFT CABIN FLASHLIGHT IAW AMM 33-50-16 OPS CHECK GOOD.SDR SIMA2018102919004Skin · crackedSKIN CRACKED AROUND RIVETS ON FRAME 80. C/A-ACCOMPLISHED REPAIR IAW SRM 53-32-01.SDR SIMA2018102219002Light · inoperativeGALLEY AREA EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED GALLEY AREA EMERGENCY LIGHT LAMP IAW AMM TASK 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECK GOOD.SDR SIMA20181019001Unknown · odorFA REPORTS BURNING SMELL COMING FROM FORWARD TO MID CABIN. C/A-PERFORMED ETN- EM-72-034. COULDN'T REPLICATE DISCREPANCY OF RUBBER BURNING SMELL ANYWHERE IN COCKPIT OR CABIN.SDR RAIA2018110518004Angle · corrodedLOWER Z ANGLE AT CARGO DOOR SHEAR CLIP AT FRAME 65 IS CORRODED................REMOVED AND REPLACED LOWER Z ANGLE AT CARGO BAY DOOR SHEAR CLIP AT FRAME 65SDR RAIA201810180003Floor Support · corrodedOMEGA BEAM AT FRAME 61 HAS CRACKS AT NUTPLATE. FABRICATED AND INSTALLED DOUBLER ON OMEGA BEAM AT FRAME 61.SDR SIMA2018102918003Light · inoperativeNUMBER NR 4 EMERGENCY LIGHT STRIP INOP. C/A-REMOVED AND REPLACED NR 4 EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA201810198001Inverter · inoperativeEMERGENCY EXIT LIGHT ABOVE SERVICE DOOR INOP. C/A-REMOVED AND REPLACED NR 2 EMERGENCY LIGHT INVERTER OPS CHECK GOOD IAW AMM 33-50-11.SDR RAIA2018111170013Floor Support · corrodedL PROFILE AT FRAME 53 O/B OF R/H OMEGA BEAM HAS CORROSION.............REMOVED AND REPLACED L PROFILE AT FRAME 53 O/B OF R/H OMEGA BEAMSDR RAIA2018111170012Floor Support · corrodedL PROFILE AT FRAME 30 O/B R/H OMEGA BEAM HAS CORROSION................REMOVED AND REPLACED L PROFILE AT FRAME 30 O/B R/H OMEGA BEAMSDR RAIA2018110870011Floor Support · corrodedL PROFILE AT FRAME 34 O/B OF R/H OMEGA BEAM HAS CORROSION.................REMOVED AND REPLACED L PROFILE AT FRAME 34 O/B OF R/H OMEGA BEAMSDR RAIA2018111067010Profile · corrodedL PROFILE AT FRAME 39 O/ OF R/H OMEGA BEAM HAS CORROSION............REMOVED AND REPLACED L PROFILE AT FRAME 39 O/B OF R/H OMEGA BEAM THIS IS A SUPPLEMENTAL REPORT CONTOL # AND DATE WHERE WRONGSDR RAIA201810170009Support · corrodedFRAME 62 RT LOWER CARBON RING SUPPORT HAS CORROSION. REMOVED AND REPLACED FRAME 62 RT LOWER CARBON RING SUPPORT.SDR RAIA201810170008Floor Support · corrodedFRAME 60 CENTER OMEGA BEAM HAS CORROSION. FABRICATED AND INSTALLED DOUBLER AT FRAME 60 CENTER OMEGA BEAM AT FRAME 60.SDR RAIA201810170007Floor Support · corrodedFRAME 62 CENTER OMEGA BEAM HAS CORROSION. FABRICATED AND INSTALLED DOUBLER ON CENTER OMEGA BEAM AT FRAME 62.SDR RAIA201810170006Floor Support · corrodedFRAME 60 RT OMEGA BEAM HAS CORROSION. FABRICATED AND INSTALLED DOUBLER ON RT OMEGA BEAM AT FRAME 60.SDR RAIA201810170005Floor Support · corrodedFRAME 62 RT OMEGA BEAM HAS CORROSION. FABRICATED AND INSTALLED DOUBLER ON RT OMEGA BEAM AT FRAME 62.SDR RAIA201810170004Floor Support · corrodedL PROFILE AT FRAME 44 O/B OF RT OMEGA BEAM HAS CORROSION. REMOVED AND REPLACED L PROFILE AT FRAME 44 O/B OF RT OMEGA BEAM.SDR RAIA2018103070003Structure · corrodedL PROFILE AT FRAME 44 I/B OF RT OMEGA BEAM HAS CORROSION. REMOVED AND REPLACED L PROFILE AT FRAME 44 I/B OF RT OMEGA BEAM.SDR RAIA2018103070002Structure · corrodedL PROFILE AT FRAME 49 I/B OF RT OMEGA BEAM HAS CORROSION. REMOVED AND REPLACED L PROFILE AT FRAME 49 I/B OF RT OMEGA BEAM.SDR SIMA2018102917005Structure · dentedSERVICE DOOR LOWER EDGE IS DENTED. C/A-REPAIRED SERVICE DOOR LOWER EDGE IAW ERS-EM-52MR-911.SDR HNAA2018101900262Fan · odorPDIS 638 21-24 1595132 17OCT18 PHL CLOSE ELECTRICAL SMELL OBSERVED AFTER APU ATTEMPTED START. OUTSIDE OF AIRCRAFT NEAR GPU PLUG-IN. 76840 00 VAG HISTORY: FACT 17OCT18 22:20 PHL INSP AND FOUND EXHAUST FAN SMELLING BURNT R&R EXHAUST FAN. OPS CHECK FAILED. SEE SESDR ASOA201810187173Skin · dentedDENT AT FRAME 22A AND STRINGER 11R AREA. CUTOUT DAMAGE AREA, FABRICATED FILLER AND DOUBLER. INSTALLED, SEALED AND REFINISHED. AIRCRAFT STILL IN C CHECK.SDR ASOA201810187172Stringer · dentedBETWEEN FRAME 23 AND 24 STRINGER 19R AND 20R DENTED. REMOVED AND REPLACED A SECTION OF STRINGER 19R AT FRAME 23 TO 25. AIRCRAFT STILL IN C CHECK.SDR SIMA20181017001Unknown · odorRAMPERS REPORT ELECTRICAL SMOKE SMELL IN BAGGAGE COMPARTMENT. PERFORMED INSPECTION OF CARGO COMPARTMENT VERIFIED COMPARTMENT LIGHTING AND NO SMELLS NOTED. IAW AMM 33-31-00 NO DEFECTS NOTED NO SMELL NOTED AT THIS TIME. A/C OK FOR SERVICE.SDR RAIA2018101870001Glowstrip · loosePHOTO ILLUMINSCENT FLOOR STRIPO LOOSE AT ROW 1. RESECURED FLOOR STRIP.SDR SIMA20181016005Light · crackedNR 6 FLOOR LIGHTING STRIP IS CRACKED AT THE HOLES. C/A-COMPLETE:INSTALLED NEW NR 6 FLOOR LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20181016004Light · crackedNR 4 FLOOR LIGHT STRIP IS CRACKS BY THE HOLES. C/A-COMPLETE:INSTALLED NEW NR 4 FLOOR LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20181016006Wire · brokenNR 8 FLOOR LIGHT STRIP HAS A BROKEN WIRE. C/A-COMPLETE:INSTALLED NEW FLOOR PROXIMITY LIGHT STRIP ON AIRCRAFT IAW AMM 33-50-12.SDR SIMA20181016007Light · cracked1 EACH EMERGENCY LIGHT STRIP CRACKED. C/A-COMPLETE:INSTALLED 2 EACH NEW FLOOR PROXIMITY LIGHT STRIPS ON LIGHT STRIP EXTRUSION IAW AMM 33-50-12.SDR SIMA20181016009Apu · fireTRANSFERRED FROM AML PAGE 4399798/1 - REF TDMI 909T4951. APU FIRE COWL LEAVING RIVET HEAD MARKS ON APU FIREWALL AND FRAME BOTTOM. SEE NRTC E520460. E WESTFALL 437731. REF LOG PAGE 4030028 ITEM 3. C/A-COMPLETE:C/W PERM REPAIR APU FIREWALL IAW ERS-EM-49MR-074. TSDR SIMA20181016008Light · crackedNR 5 FLOOR LIGHT STRIP IS CRACKS BY THE HOLES. C/A-COMPLETE: INSTALLED NEW EMERGENCY LIGHT STRIP FOR NR 5 POSITION IAW 33-50-12.SDR ASOA2018101864061Light · odorIAH - FLIGHT 4363 THE CREW REPORTED AN ELECTRICAL SMELL ON THE LEFT SIDE OF THE AIRCRAFT. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE LIGHT BULB AT SEAT 1A. OPERATIONAL TESTS WERE PERFORMED SATISFACTORALLY, AND THE AIRCRAFT WAS APPROVED FORSDR SIMA20181016003Light · inoperativeDURING PS-1 CHECK FOUND EMERGENCY OVERWING DOOR LT EXIT SIGN INOP, INSIDE CABIN. REMOVED AND REPLACED LT EMERGENCY DOOR EXIT SIGN LIGHT ASSY IAW AMM 33-50-14 OPS CHECK GOOD.SDR HNAA2018101700261Engine · smokeNR 1 ENG EXHAUST SMOKED ON S/D. INSPECTED NR 1 ENG AND FOUND NO DEFECTS.SDR HNAA2018101700255Warning System · false activationPDIS 660 36-10 1722792 16OCT18 PHL CLOSE DURING INFLIGHT DEICE CHECK BLD 2 VLV FAIL AND BLD 2 VLV CLOSED EICAS MESSAGE ILLUMINATED. 28769 00 PCS HISTORY: NONE FACT 16OCT18 12:00 PHL RAN ENGINE NR 2 AND OPERATED BLEED VALVE. NO ISSUES NOTED. NO RELATED MESSAGESSDR RAIA2018111350004Floor Support · corrodedCENTER OMEGA BEAM FROM FRAMES 38-46 HAS CORROSION..........REMOVED AND REPLACED CENTER OMEGA BEAM FROM FRAMES 38-45SDR RAIA2018111250003Floor Support · corrodedCENTER OMEGA BEAM FROM FRAMES 45-52 HAS CORROSION.............REMOVED AND REPLACED CENTER OMEGA BEAM ASSY FROM FRAMES 45-52 THIS IN CLUDES CENTER OMEGA BEAM GUSSETT FROM FRAMES 45-52SDR RAIA201810150001Floor Support · corrodedLT OMEGA BEAM FROM FRAMES 46-52 HAS CORROSION. REMOVED AND REPLACED LT OMEGA BEAM FROM FRAMES 46-52.
Back to Embraer EMB-145LR