Embraer EMB-145LR
Service difficulty reports · 36,795
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2026022700158Unknown · odorSULFER BURNING SMELL IN FLIGHT DECK AND CABIN WITH PACK 2 RUNNING. PERFORMED A GVI AND PACK 2 OPERATIONAL TEST IAW AMM 21-51-00 NO DEFECTS NOTED. A/C OK FOR SERVICE AT THIS TIME.SDR HNAA2026032600244Pin · damagedPILOT'S BULKHEAD OTBD GUIDE PIN HOLE ELONGATED. PERFORMED PERMANENT REPAIR OF PILOT'S BULKHEAD OTBD GUIDE PIN HOLE IAW EO1-53-26-0135 AND SRM 53-21-02RE, ITEM 4, FIG 204.SDR HNAA2026032600235Crossbeam · corrodedGALLEY CROSSBEAM AT FR 18 IS CORRODED. REMOVED AND REPLACED WITH A SERVICEABLE GALLEY CROSSBEAM AT FR 18 IAW SRM 51-40-02.SDR HNAA2026032600240Floor Support · corrodedCARGO RT FLOOR SUPPORT NR 4 IS CORRODED. REMOVED AND REPLACED CARGO RT FLOOR SUPPORT NR 4 IAW SRM 51-40-02.SDR HNAA2026032600239Floor Support · corrodedLH FLOOR SUPPORT NR 2 HAS CORROSION IN MULTIPLE SPOTS. REMOVED AND REPLACED LT FLOOR SUPPORT NR 2 IAW SRM 51-40-02SDR HNAA2026032600234Floor Support · corrodedRIGHT CABIN FLOOR SUPPORT NR 6 IS CORRODED. REMOVED AND REPLACED RT CABIN FLOOR SUPPORT NR 6 IAW SRM 51-40-02.SDR HNAA2026032600232Floor Support · corrodedCARGO L/H FLOOR SILL #2 IS CORRODED. REMOVED AND REPLACED CARGO L/H FLOOR SILL #2 IAW EMB 145 SRM 51-40-02.SDR HNAA2026022500157Apu · odorAFTER LANDING DURING APU START, JET FUEL SMELL IN FLT DECK AND IN CABIN FOR APPROX 20 SECONDS. APU AUXILIARY POWER UNIT FACT 25FEB26 04:09 PHL OPERATED APU AND ENGINES. NO JET FUEL SMELL PRESENT IN FLIGHT DECK AND CABIN IRT AMM 71-00-01. A/C OK FOR SESDR HNAA2026032600247Rib · crackedRIGHT WING RIB 21 IS CRACKED. PERFORMED CUTOUT OF CRACKED SECTION OF RT WING RIB 21 AND PERFORMED PERMANENT REPAIR OF RIB IAW PIEDMONT EO1-57-26-0136 AND EMB 145 SRM 57-20-07RE ITEM 4, FIG 203.SDR HNAA2026032600246Rib · crackedLEFT WING RIB 21 IS CRACKED. PERFORMED CUT OUT OF DAMAGE, AND INSTALLED DOUBLER, FILLER AND SHIM FOR REPAIR ON L/H WING RIB 21 IAW EMB 145 SRM 57-20-07RE ITEM 4 FIG. 203, ETD2026-145-004869 AND EO1-57-26-0140.SDR HNAA2026022400154Unknown · odorFUEL SMELL ENTERED COCKPIT AFTER APU START ON LANDING WITH PACKS 1 & 2 RUNNING. INSPECTED E1 & E2 INLETS & DUCTS, NO DEFECTS NOTED. INPSECTED APU INLETS & EXHAUST & COWLING W/NO DEFECTS NOTED. RAN PACKS FOR 10-15 MINUTES W/NO ODOR. NOTICED. OPS CHECK DONESDR HNAA2026022400153Wire · damagedEMERGENCY LIGHT ON SERVICE DOOR IS NOT ILLUMINATING. FOUND W76-0007-20 BROKEN. REPAIRED W76-0007-20 IAW SWPM 20-21-00. OP CHECKED SERVICE DOOR EMERGENCY LIGHT IAW AMM 33-50-00-700-801-A. OP CHECK GOOD.SDR HNAA2026022400152Pressure Switch · faultedHS VLV 2 FAIL ON TAKEOFF ROLL. REJECTED TAKEOFF AT 50 TO 60 KNOTS. FACT 23FEB26 12:10 PHF R & R HIGH STAGE PRESSURE SWITCH IRT AMM TASK 36-11-07-000/400-801-A. R+R #200 HIGH STAGE VALVE IRT AMM TASK 36-11-02-00/400-801-A. OPS CHECK GOOD. OK FOR SERVICE.SDR HNAA2026022400155Unknown · odorFUEL SMELL ENTERED COCKPIT AFTER APU START ON LANDING WITH PACKS 1 & 2 RUNNING INSPECTED E1 & E2 INLETS & DUCTS, NO DEFECTS NOTED. INPSECTED APU INLETS & EXHAUST & COWLING W/NO DEFECTS NOTED. RAN PACKS FOR 10-15 MINUTES W/NO ODOR NOTICED. OPS CHECK DONE IASDR HNAA2026022400151Control Unit · faultedPTRIM BACK UP INOP IN FLIGHT AND RTF. T/S SYST3M WIRES AND CONNECTORS IAW FIM 27-43-00-810-802-A OPS CHECK GOOD COULD NOT DULICATE EICAS OR CMC MESSAGE DURING T/SPER MOC POITIVE MAINT R/R HSCU IAW AMM 27-40-01 OPS CHECK IAW AMM 27-40-00-700-802A OPS CHECK GOSDR HNAA2026022400150Transducer · faultedWING A/ICE FAIL DISPLAYED IN ICING DURING DECENT. CMC SAYS WING 2 A/ICE LOW PRESS-E1-2 A/ICE VLV FAIL. FOUND WING 2 A/ICE LOW PRESS ON CMC. T/S IRT FIM 30-11-00-810-811-A TO STEP 24. R & R WING 2 A/ICE PRESS TRANSDUCER IRT EMB 145 AMM 30-11-11. OPS CHECKSDR HNAA2026032600243Skin · crackedREAR FUSELAGE EXTERNAL SKIN HAS POSSIBLE CRACK AROUND RIVET AT FR 78 BETWEEN STGR 4L / 5L. PERFORMED CUTOUT OF CRACK AROUND RIVET ON REAR FUS EXTERNAL SKIN AT FR 78 AND BTW STR 4L-5L AND PERFORMED PERMANENT REPAIR OF SKIN AT FR 78 AND BTW STR 4L-5L IAW PIEDMOSDR HNAA2026022400149Warning Message · intermittentWING ANTI ICE FAIL MESSAGE DISPLAYED INTERMITENT IN CRUISE AND DECENT. NO RELATED CMC MESSAGES PERFORMED OPS TEST OF A/I SYSTEM IAW AMM 30-00-00-700-802-A. OPS TEST GOOD. CREW RAN ENGINES FOR TEST.SDR HNAA2026032600238Skin · corrodedLEFT MAIN LANDING GEAR BAY LOWER SKIN FWD OF MAIN LANDING GEAR MAIN SIDE STRUT CORRODED. R & R THE LT MAIN LANDING GEAR BAY LOWER SKIN FWD OF THE MAIN LANDING GEAR SIDE STRUT IAW SRM 51-40-02.SDR HNAA2026030400194Shear Tie · cracked00738 CRACK FOUND IN SHEAR TIE AT FRAME 24 BETWEEN STR 15L AND 16L. REMOVED AND INSTALLED NEW SHEAR TIE AT FR 24 BETWEEN STR 15L AND 16L. REF EMB 145 SRM 51-40-02-PR,SDR 4DPA2026021900001Smoke Detector · dirtyPILOT REPORTED-AFTER TAKEOFF & PASSING THROUGH 2,000 FT, CREW RECEIVED A MASTER WARNING FOR LAV SMOKE. STOPPED THE CLIMB AT 3,000 FT AFTER ASKING THE FLIGHT ATTENDANT IF THERE WAS ANY SMOKE COMING FROM THE LAV. THE FLIGHT ATTENDANT CONFIRMED SMOKE COMING FROM SDR HNAA2026022000146Power Supply · inoperativeEXTERNAL EMERGENCY LIGHT ON RH SIDE OF FWD WING TO FUSE FAIRING IS INOP. R & R NR 2 EMERGENCY BATTERY POWER SUPPLY IAW AMM 33-50-04.SDR HNAA2026021900138Unknown · odorON CLIMB FLIGHT DECK SMELLED OF BURNING RUBBER DISAPATED AT 5000 FEET AND DID NOT REOCCUR. CHECKED PACK 1, 2, & FWD AVIONICS BAY, NO ODOR FOUND. RAN ENG 1 TWICE, COUND NOT DUPLICATE SMELL. A/C OK FOR SERVICE AT THIS TIME.SDR HNAA2026031800226Angle · crackedRIGHT OVERWING FAIRING 1ST ANGLE CRACKED. REPAIRED ANGLE IAW SRM 57-20-01RESDR HNAA2026031700217Angle · crackedLT OVERWING FAIRING 1ST ANGLE CRACKED. REMOVED, FABRICATED ANGLE, AND INSTALLED IAW SRM 57-20-01SDR HNAA2026031100207Angle · crackedLEFT OVERWING FAIRING 4TH ANGLE CRACKED. REPAIRED ANGLE IAW SRM 57-20-01 ITEM 3 (FIG 205)SDR HNAA2026030400196Angle · crackedRIGHT OVERWING FAIRING 4TH ANGLE CRACKED. R A R ANGLE IAW SRM 51-40-02SDR HNAA2026030200164Angle · crackedRIGHT OVERWING FAIRING 5TH ANGLE CRACKED. CUTOUT PERFORMED, REPAIR DOUBLER AND FILLER INSTALLED IAW SRM 57-20-01 AND EO1-57-26-0079SDR HNAA2026022400156Angle · crackedRIGHT OVERWING FAIRING 2ND ANGLE CRACKED. RAR ANGLE IAW SRM 51-40-02SDR HNAA2026022000144Fairing · crackedLEFT OVERWING FAIRING CRACKED AT 2ND ANGLE. RAR ANGLE IAW SRM 51-40-02SDR HNAA2026021600119Dau · intermittentDAU 2A FAIL INTERMITENLY IN FLIGHT. R&R DAU #200 IAW AMM 31-41-01. OPS CHECK GOOD. NO MSG ON EICAS OK FOR SAERVICE AT THIS TIME.SDR HNAA2026021600128Switch · abnormalYAW DAMPER FAIL'D JUST BEFORE RUD SYS 1-2 INOP DISPLAYED. C/W QRH. R&R RUDDER SYSTEM 2 PSI SWITCH IAW 27-23-04 OPS AND LEAK CHECK GOOD. PERFORMED INTEGRATED COMPUTOR OPS CHECK IAW AMM 31-42-00 AND FOUND NO DEFECTS. MX ACTION COMPLETE SUBJECT TO SAT EVAL SDR HNAA2026021600121Contactor · arcedAPU GEN OVERLOAD FOLLOWED BY APU GEN FAIL FOLLOWED WITH APU SHUTDOWN WITH BURNING SMELL IN FLIGHT DECK WITH SMOKE FROM APU EXHAUST MEL 14FEB26 13:49 CLT C04522 49-1 APU AUXILIARY POWER UNIT DFRL 15FEB26 06:26 ALB SEE HA 300 SEQ 7 OF ALB RON PACKAGSDR HNAA2026021600120Ballast · abnormalRIGHT AFT EXTERNAL EMERGENCY LIGHT INOPERATIVE. R & R AFT EXTERNAL EMERGENCY LIGHT RT BALLAST IAW AMM 33-50-10-000/400-801-A, OPS CHECK PERFORMED WITH NO DEFECTS NOTED.SDR HNAA2026032600245Trunnion · damagedRIGHT NLG BEARING HOUSING HAS TEMPORARY REPAIR IAW ETD2023-145-026080A REQUIRES REPLACEMENT. R & R THE RT NLG TRUNNION IAW ETD2023-145-026080 REV. A AND PIEDMONT EO1-53-26-0127 DMT 10.SDR HNAA2026031700221Rib · cracked53-2200 LH AND RH WHEEL WELL REAR RIBS CRACKED. RAR RIBS IAW SRM 51-40-02SDR HNAA2026030400193Frame · damaged00705 AFTER REMOVAL OF SILL FROM RH SIDE BETWEEN FR 61 TO FR 64 FOUND ELONGATED HOLE AT FR 62. COMPLIED WITH REPAIR TO FRAME 62 AT STR 16R PER EMB 145 SRM 53-00-04 ITEM 14 FIGURE 206.SDR HNAA2026031000206Bracket · cracked54-2176 RH PYLON HAS CRACKED FORE PRECOOLER STRUCTURE BRACKET. RAR BRACKET IAW SRM 51-40-02SDR HNAA2026030400195Bracket · crackedLEFT PYLON FWD AND AFT PRECOOLER STUCTURE BRACKETS CRACKED. RAR BRACKETS IAW SRM 51-40-02SDR HNAA2026031100208Shear Tie · crackedSHEAR TIE CRACKED AT FR67 BTW STR8-9L. REMOVED, FABRICATED NEW PART IAW DWG 145-24766-013 WITH ETD145-26-003130, AND INSTALLED SHEAR TIE IAW SRM 51-40-02SDR HNAA2026030400192Floor Support · damagedAFTER REMOVAL OF LH FLOOR SILL AT FR 23 TO FR 29 FOUND ELONGATED HOLE AT FR 24. COMPLIED WITH PERMANENT REPAIR ON FR 24 BETWEEN STR 15L - 16L PER EMB145 SRM 53-00-04 ITEM 14 FIGURE 206, ETD2026-145-002730 REV.:/, AND EO1-53-26-0088SDR HNAA2026030400191Floor Support · damaged00691 AFTER REMOVAL OF LH SILL FROM FR23 TO FR29 FOUND ELONGATED HOLE AT FR 28. COMPLIED WITH PERMANENT REPAIR ON FR 28 BETWEEN STR 15L - 16L PER EMB 145 SRM 53-00-04 ITEM 14 FIGURE 206, ETD2026-145-002725 REV.:/, AND EO1-53-26-0086.SDR HNAA2026022000148Angle · crackedLWR ANGLE CRACKED AT FR67. R & R ANGLE IAW SRM 51-40-02SDR HNAA2026022000147Angle · crackedLWR ANGLE CRACKED AT FR66. R & R ANGLE IAW SRM 51-40-02.SDR HNAA2026022000143Tee Angle · corrodedCORROSION ON RT FLOOR T PROFILE AT FR61. RAR PROFILE IAW SRM 51-40-02SDR HNAA2026022000142Angle · crackedANGLE CRACKED AT FR62 BTW STR4-5R. RAR ANGLE IAW SRM 51-40-02SDR HNAA2026022000141Support Angle · corrodedSUPPORT ANGLE CORRODED AT BTW FR67-68 STR4R. RAR SUPPORT IAW SRM 51-40-02SDR HNAA2026021700135Shear Tie · crackedSHEAR TIE CRACKED AT FR65 BTW STR18 - 19L. R & R SHEAR TIE IAW SRM 51-40-02.SDR HNAA2026031700216Floor Support · crackedLEFT OMEGA BEAM CRACKED AT BTW FR23-24. REPAIRED IAW ETD2026-145-00206 AND EO1-53-26-0099SDR HNAA2026031700215Floor Support · crackedLEFT OMEGA BEAM CRACKED AT FR21. REPAIRED IAW ETD2026-145-002736
Back to Embraer EMB-145LR