Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20171213005Lamp · inoperativeL/H OVERWING EMERGENCY LT INOP-C/A-REMOVED AND REPLACED L/H OVERWING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A..OPC GOOD AT THIS TIME.END.SDR SIMA20171213003Engine · odorLEVEL @ 16000' BOTH ACS ON BUILDING CHEMICAL LIKE SMELL WAS DETECTED BY BOTH FLIGHT CREW MEMBERS AND ALSO THE F/A WHEN SHE CAME TO THE FORWARD CABIN. THE SMELL WAS IRRITATING TO THE THROAT. "TRANSFERRED TO NRWC 692-CMI-03243"-C/A-TRANSFERRED FROM NRWC 692-CMI-SDR SIMA20171213004Connector · disconnectedEMERGENCY LIGHTS #4,5 FLOOR PROX. LIGHTS AND ALL OVERWING EMERGENCY EXIT INTERI0R EMERGENCY LIGHTS WILLL NOT ILLUMINATE.-C/A-T/S IAW WM 33-50-50 REMOVED FLOOR PANEL 251JF IAW AMM 53-01-02 AND FOUND ELECT. CONNECTOR P8031 COMPLETELY DISCONNECTED. FROM #3 BATTERSDR SIMA20171213006Bushing · damagedALL 4 FLANGED BUSHINGS FOR RIGHT HAND AILERON TO PCA ATTACH POINTS ARE DAMAGED. -C/A-INSTALLED NEW PCA FITTING ON THE RIGHT HAND AILERON IAW EO WORK CARD EM-27M2-112.SDR ASOA201712137031Stringer · crackedDURING THE "C" CHECK/"5A" CHECK INSPECTION, A CRACK WAS IDENTIFIED ON STRINGER 2L, LOCATED AT FRAME 75. THIS DISCREPANCY WAS CORRECTED BY REMOVING THE DAMAGED SEGMENT OF THE STRINGER, ADDING A NEW SEGMENT, AND DOUBLER. THE REPAIR WAS PERFORMED IN ACCORDANCE SDR SIMA20171213001Cradle · inoperativeINOP AFT CABIN FLASHLIGHT HOLDER-C/A-REPLACE BASE IAW AMM 33-50-16SDR SIMA20171212004Angle · crackedAPU FIREWALL ANGLE AT FRAME 80 STR 9L IS CRACKED.SDR SIMA20171212003Attach Bracket · crackedRT. OVERWING PANEL, #2 LOWER ATTACHMENT BRACKET CRACKED. -C/A-REMOVED, FABRICATED AND INSTALLED NEW ATTACHMENT BRACKET IAW ETN-EM-53-142.SDR SIMA20171212002Charger · inoperativeRH FWD OVERWING EMERG, AND OVRHD ISILE EMERG LIGHTS ARE OUT.-C/A-REMOVED AND REPLACED #2 EMER POWER SUPPLY AND CHARGER IAW EMB-145 AMM 33-50-04. OPS CHK GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 105196SDR SIMA20171211002Engine · failed#2 ENGINE FAILED IN FLIGHT APPROXIMATELY 2 MIN AFTER TAKEOFF. FAILURE WAS ABRUPT, CREW FELT A THUMP THROUGH THE FLOOR. FO REPORTS HEARING A BANGING SOUND. N2 WENT TO 0.0%IMMEDIATELY E2 NO DISP AND HS VLV 2 FAIL ON SHUTDOWN, E2 NO DISP DISAPPEARED WHEN SWITCHSDR SIMA20171211006Unknown · odorAFTER TAKEOFF FLIGHT ATTN ADVISED CABIN FILLING WITH SMOKE LAV SMOKE WARNING ON EICAS. CONFIRMED APU IS NOT THE SOURCE OF THE ODOR. OPC APU IAW EMB AMM 49-13-00. OPC GOOD.SDR HNAA2017121500390Wire · brokenNDIS 683 33-51 0001790 11DEC17 RIC CLOSE
SERVICE DOOR EMERGENCY LIGHT WONT ILLUMINATE
28805 00 SJU
FACT 11DEC17 08:17 RIC
FOUND BROKEN WIRES W716-0007-20 AND W716-0008-20 REP
SDR SIMA20171211005Lamp · inoperativeSERVICE DOOR EMERGENCY LT INOP-C/A-REMOVED AND REPLACED SERVICE DOOR EMERGENCY LAMP IN REFERENCE WITH EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FURTHER DISCREPANCIES FOUND. END.SDR SIMA20171211004Battery Pack · inoperativeBOTH EXTERIOR OVERWING EMERGENCY LTS INOP-C/A-REMOVED AND REPLACED #4 EMERGENCY BATTERY AND POWER SUPPLY IAW ENVOY W/C 33-700-19 AND 33-700-17 OPS CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 12701SDR SIMA20171211003Battery Pack · inoperativeEMERGENCY EXIT LIGHTS OVER THE WINGS INOP-C/A-REMOVED AND REPLACED FUSE ON #4 EMERGENCY BATTERY IAW RADIANT CMM 25-60-03 AND EMB AMM 33-50-00.OPS TEST OF EMERGENCY LIGHTS GOOD.NO OTHER DEFECTS NOTED AT THIS TIME.SDR ASOA201712117030Skin · crackedR/H REAR FUSELAGE SKIN AT FRAME 75 STRINGER 1R-3R CRACKED.CUT-OUT DAMAGE SECTION OF EXT FUSELAGE SKIN, FABRICATED REPAIR PARTS AND INSTALLED. AIRCRAFT STILL IN C CHECK.SDR 4VAA20171211010Bleed Air Sys · failedAIRCRAFT AT GATE. AFTER APU BLEED AIR WAS SELECTED ON WITH CROSS BLEED VALVE OPEN, CREW IMMEDIATELY RECEIVED A CROSS BLEED VALVE FAIL MESSAGE. ONE MINUTE LATER THE BLEED APU LEAK MESSAGE APPEARED. CREW FOLLOWED PROCEDURES AND SHUT APU DOWN.
MAINTENANCE FOUNDSDR HNAA2017121500389Power Supply · inoperativeNDIS 640 33-51 0013530 08DEC17 SBY CLOSE
FWD EMERGENCY EXIT LIGHT UNDER COCKPIT DOOR INOP.
FACT 08DEC17 13:29 SBY
SLAVED IN EMERGENCY EXIT LIGHT SIGN NO FIX. R&R EMER
GENCY BATT POWER SUPPLY 1 IAW AMM 33-50-04-000-SDR SIMA20171210003Charger · inoperativeFOUND AFT EXTERIOR RH EMERGENCY LIGHT TO BE INOP DURING PS-1 CHECK-C/A-REMOVED AND REPLACED #4 BATTERY POWER SUPPLY IAW EMB 145 AMM 33-50-04-04. OPS CHECK GOODSDR SIMA20171210001Lamp · inoperativeRH WING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED THE RH WING EXTERNAL EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-10, OPS CHECK GOODSDR SIMA20171209005Floor Support · crackedLEFT CABIN OMEGA BEAM SUPPORT, CRACKED AT FRAME 50. -C/A-REMOVED AND REPLACED INDICATED L/H CABIN OMEGA BEAM SUPPORT IAW SRM 51-40-02.SDR SIMA20171209004Door Frame · crackedBAGGAGE DOOR FORWARD FRAME BOX FOR LIFT/LOERING MECHANISM HAS CRACK AT FORWARD LOWER END.-C/A-COMPLETED REPAIR IAW SRM 53-23-02.SDR SIMA20171209003Shear Tie · crackedSHEAR CLIP AT FRAME 80, BETWEEN STRINGERS 05R AND 07R IS CRACKED.-C/A-REMOVED AND REPLACED SHEAR CLIP AT FRAME 80 BETWEEN STRINGERS 5R AND 7R IAW SRM 51-40-02.SDR SIMA20171209006Floor Support · crackedRIGHT CABIN OUTBRD OMEGA BEAM SUPPORT, CRACKED BETWEEN FRAMES 47-48.-C/A-COMPLETED REPAIR IAW SRM 53-23-02.SDR SIMA20171209001Charger · unknownREPLACE EPSU CHARGER-C/A-REMOVED & REPLACED EPSU BATTERY #1 IAW WC 33-700-19 OPS CHECK GOOD IAW WC 33-700-17SDR SIMA20171209002Charger · failedLH AND RH AFT OVERWING EXIT LIGHTS INOP-C/A-REMOVED AND REPLACED #4 EMRG BATT IAW ENVOY MTX WC 33-700-17. OPC GOODSDR HNAA2017121100388Power Supply · inoperativeL/H AND R/H EXTERIOR OVER WING EMERGENCY LIGHTS INOP..........R&R #4 EMERGENCY BATTERY AND POWER SUPPLY ASSY WITH RETAINED HARDWARE AND SECURED OVERHEAD PANEL AND LIGHT COVER WITH RETAINED HARDWARESDR HNAA2017121100387Unknown · odorPDIS 633 05-50 1094931 09DEC17 PHL CLOSE
DURING CLIMB OUT, ELECTRICAL ODOR IN BOTH FLT DECK A
ND CABIN, ENG BLEEDS WERE ON AND APU WAS OFF. WHILE
RETURNING TO FIELD SMELL DISIPATED
FACT 09DEC17 02:19 PHL
PERFORMSDR ASOA201712074065Battery Pack · dischargedIAH - DURING MAINTENANCE INSPECTION EMERGENCY LIGHT STRIPS 1, 2, & 3 WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO (2) EMERGENCY LIGHT BATTERY PACK, OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR RETURN TSDR SIMA20171207001Valve · failedCLIMBING THROUGH 11,000 FT CABIN WARNING. WOULD NOT WORK IN AUTO OR MAN MODE. RETURN TO AIRPORT. PERFORMED INSTALL NEW GROUND CONNECTION VALVE IAW AMM 21-22-04 OPS AND PRESSURIZATION CHECK GOOD. INSTALL BOTH ESCAPE HATCHES IAW AMM 52-21-00 OPS AND PRESSURE CSDR RAIA201712060001Skin · crackedCARGO DOOR SKIN CRACKED AT UPPER AFT CORNER OF DOOR HANDLE CUTOUT. INSTALLED A FILLER AND DOUBLER.SDR SIMA20171206004Attach Fitting · damagedLEFT HAND AILERON PCA ATTACH FITTING OUTBOARD LUG HAT BUSHING MIGRATING OUT OF FITTING. -C/A-REPLACED AILERON WITH NEW. SEE NRWC E609824 FOR INSTALLATION AND E611839 FOR FCFSDR SIMA20171206003Attach Fitting · damagedRIGHT HAND AILERON PCA ATTACH FITTING OUTBOARD LUG HAT BUSHING MIGRATING OUT OF FITTING. -C/A-REMOVED AND REPLACED R/H AILERON PCA FITTING ASSY IAW EO EM-27MR-112.SDR RAIA201712050001Skin · damagedREAR FUSELAGE EXTERNAL SKIN DENTED AND SCRATCH BETWEEN FRAMES 72 - 73, STRINGERS 10R-13R. FABRICATED AND INSTALLED A STRAP AND REPAIR PARTS.SDR ASOA201712054064Battery Pack · weakIAH- DURING MAINTENANCE INSPECTION THE EMERGENCY LIGHT BATTERY PACKS AT LOCATIONS 3 & 4 WERE FOUND TO BE NOT HOLDING A CHANRGE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BATTERY PACKS, OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR SDR ASOA201712054063Battery Pack · weakIAH- DURING MAINTENANCE INSPECTION THE EMERGENCY LIGHT BATTERY PACKS AT LOCATIONS 3 & 4 WERE FOUND TO BE NOT HOLDING A CHANRGE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BATTERY PACKS, OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR SDR SIMA20171205002Acm · seizedWHILE CRUISING AT FL250 SMOKE WAS SMELLED IN COCKPIT THE FOLLOWED BY SMOKE ENTERING THE COCKPIT VIA OVERHEAD VENTS. PERFORMED RUNS AND PACK SYSTEMS TROUBLESHOOTING AND FOUND THAT NR 1 PACK SYSTEM ACM IS CEASED UP. DEFERRED NR 1 AC PACK SYSTEM REF 21-30 AUTH 12SDR SIMA20171203002Cradle · malfunctionedREAR CABIN EMERGENCY FLASHLIGH IS DIM-C/A-DURING INSPECTION OF CABIN EMERGENCY EQUIPMENT NOTICED REAR FLASHLIGHT WAS DIM REMOVED AND REPLACED BATTERY NO FIX REMOVED AND REPLACED FLASHLIGHT ASSY AND CRADLE IAW EMB 145 AMM 33--50-16 PER EEL OPS CHECK GOODSDR SIMA20171203001Flashlight · not reportedAFT CABIN EMERGENCY FLASHLIGHT NEEDS TO BE REPLACED-C/A-REMOVED AND REPLACED EMERGENCY FLASHLIGHT AS REQUIRED, NO OTHER DEFECTS NOTED AT THIS TIME.SDR ASOA201712037029Tray · defectiveEMERGENCY LIGHTS LT FORWARD OF WING AND 2ND LIGHT AFT OF PAX DOOR INOP. REMOVED AND REPLACED POWER SUPPLY TRAY. OPS CHECKED GOOD. AIRCRAFT RELEASED AND RETURNED TO SERVICE.SDR SIMA20171202005Transducer · not reportedE2 A/ICE FAIL "TRANSFERRED TO NRWC 687-DFW-02432"-C/A-REMOVED AND REPLACED R/H ENGINE PRESSURE TRANSDUCER IAW EMN MM 30-21-06 OPS CHECKED IAW EMBMM 30-21-00 OPS CHECK GOODSDR SIMA20171202002Bleed Valve · failed"BLD 2 VLV FAIL" MESSAGE ON EICAS AFTER TAKE OFF. "BLD 1 OVERTEMP" MESSAGE ON EICAS REDUCTION IN THRUST RETURNED TEMP TO NORMAL -C/A-DEFERRED BOTH BLEED VALVES MEL 36-4 AUTH 120021DM-C. REMOVED AND REPLACED #2 BLEED VALVE IAW AMM 36-11-05-400-801, MEL RESTOREDSDR SIMA20171201003Inverter · inoperativeEMERGENCY FLOOR LIGHT STRIP #1 INOP.-C/A-REMOVED AND REPLACED #2 INVERTER IAW EMB 145 AMM 33-50-11 OPS CHECK GOODSDR SIMA20171201002Light · inoperativeOVERHEAD ENTRANCE EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED OVERHEAD ENTRANCE EMERGENCY LIGHT OPC GOOD IAW EMB AMM 33-50-06SDR SIMA20171201001Flashlight · inoperativeFA FOWARD FLASHLIGHT INOP.-C/A-REMOVVED AND REPLACED FLASHLIGHT IAW AMM 33-50-16. OPS CK GOOD.SDR SIMA20171130003Support · wornRT AILERON #3 HINGE INBOARD LUG BORE IS WORN-C/A-REMOVED AND REPLACED THE RH AILERON #3 HINGE IAW EM-27MR-112.SDR SIMA20171130002Fitting · wornLT AILERON DAMPER FITTING OUTBOARD LUG BORE IS WORN-C/A-REPLACED AILERON WITH NEW. SEE NRWC E609824 FOR INSTALLATON AND E611839 FOR FCF.SDR SIMA20171130001Support · wornRT AILERON #4 HINGE OUTBOARD LUG BORE IS WORN-C/A-REMOVED AND REPLACED HINGE FITTING #4 ON R/H AILERON IAW EO EM-27MR-112.SDR ASOA201711305242Battery Pack · inoperativePILOT REPORTED 3RD & 4TH EMERGENCY LIGHTS IN CABIN CEILING ARE INOP. MX REMOVED AND REPLACED #3 EMERGENCY LIGHT BATTERY ASSY RELAMPED #3 & #4 ZONAL LAMPS WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA201711307028Uplock · failedNOSE GEAR WOULDN'T RETRACT AFTER TAKEOFF AND RETURNED TO DEPARTURE. FOUND THE NLG UPLOCK BOX AND NLG PROXIMITY SWITCHED BAD. MAINTENANCE REMOVED AND REPLACED THE NLG UPLOCK BOX AND PROXIMITY SWITCHES IAW AMM 32-33-07; 32-61-01; IPC32-33-07 PAGE 1, ITEM 30A,