Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20170331003Charger · failedDURING PS-2 FOUND LT AND RT OVERWING EMERGENCY LIGHTS INOP. REMOVED AND REPLACED LT SIDE CENTER FAIRING EXTERNAL EMERGENCY LIGHT ASSEMBLY IAW AMM 33-50-10. REMOVED AND REPLACED BATTERY POWER SUPPLY 3 AND 4 IAW AMM 33-50-04. R&R BATTERY CHARGER 4 IAW AMM 33-50-SDR SIMA20170331001Inverter · inoperativeEMERGENCY LIGHT ON AFT GALLEY WALL INOP. REMOVED AND REPLACED 3 EMERGENCY LIGHT INVERTER, OPC GOOD IAW AMM 33-50-11.SDR HNAA2017040300101Switch · failedWING ANTI ICE FAIL MESSAGE, ICE CONDITION ANTI ICE WARNING, AND BLEED 1 LEAK EICAS MESSAGES DISPLAYED. RETURNED TO THE FIELD. FOUND BROKEN WIRES TO THE THERMAL SWITCH ON THE NR 1 ANTI ICE VALVE. R & R THE THERMAL SWITCH IAW AMM 36-20-02-400-801-A. PERFORMESDR SIMA20170330003Battery · dischargedNR 3 EMERGENCY LIGHT BATTERY INOP. REMOVED AND INSTALLED 3 EMERGENCY LIGHT BATTERY IAW EMERGENCY LIGHT WORKCARD 33-700-19, OPS. CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 12334.SDR SIMA20170330002Unknown · odorLIGHTNING STRIKE ENROUTE W/ AN ELECTRICAL SMOKE SMELL NOTED IN COCKPIT AND THE CABIN. LIGHTNING STRIKE INSPECTION ACCOMPLISHED IAW MTX W/C 05-200-00. REFERENCE NRWC 645-ORD-03378 FOR ELECTRICAL SMOKE SMELL NOTED IN COCKPIT AND CABIN. C/W ODOR EVENT T/S PER ETNSDR 4VAA20170318003Unknown · odorWHILE ON APPROACHB, COCKPIT CREW NOTICED A BURNING ODOR WHEN WINDSHIELD HEAT WAS SELECTED ON. APPROACH WAS CONTINUED AND ODOR WENT AWAY WHEN THE WINDSHIELD HEAT WAS SELECTED OFF. MAINTENANCE CONFIRMED POWER AND GROUND WIRES SECURED AS WELL AS THE SENSOR TERMSDR SIMA20170330001Skin · cracked3 CRACKS AROUND RIVETS ON RT FRAME 78. PERFORMED PERMANENT REPAIR OF 3 CRACKS AROUND RIVETS ON RT FRAME 78 IAW ERS-EM-53MR-2633.SDR ASOA201703303064Channel · corrodedSERVICE DOOR LOWER CHANNEL CORRODED. THE CHANNEL WAS REPLACED IAW SRM 51-40-02.SDR ASOA20170329014Light · inoperativeMAINTENANCE DISCOVERED THAT THE NR 5 AISLE EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE LIGHT, OPS TESTED WITH NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20170329002Battery · dischargedEMERG LIGHT INOP FLOOR. R&R NR 4 BATTERY AND BATTERY CHARGER AND INVERTER FOR EMERGENCY SEAT 15A,16A,17A AND 18A IAW AMM 33-50-04 AND AMM 33-50-11 OPS GOOD AT THIS TIME. CHARGER ASSY BATTERY P/N BA5-0933-901 S/N C02722. INVERTER P/N 7824-1SDR SIMA20170329001Pressure Switch · failedRUDDER SYSTEM 1 -2 INOP MSG ON EICAS AUTOPILOT AND YAW DAMPER KICKED OFF ABOUT THE SAME TIME. PERFORMED FIM TASK, 27-22-00-810-804-A AND REMOVED AND REPLACED THE RUDDER SYSTEM NR 2 PRESSURE SWITCH, IAW AMM 27-23-04, OPS CHECK GOOD. PERFORMED FUNCTIONAL TEST OSDR ASOA201703293063Floor Support · corrodedREAR FUSELAGE FLOOR SUPPORT CORRODED. REPLACED IAW SRM 51-40-02.SDR ASOA201703293062Floor Support · corrodedCABIN NR 1 FLOOR SUPPORT CORRODED. REPLACED IAW SRM 51-40-02.SDR ASOA201703293061Gusset · corrodedLEFT GUSSET CORRODED AROUND ANCHOR NUT BETWEEN FRAMES 16 AND 17. THE GUSSET WAS REPAIRED IAW SRM 53-21-10, ITEM 2, FIG 201.SDR ASOA201703293060Seat Track · corrodedCABIN LT INBOARD SEAT TRACK NR 1 CORRODED. LT INBOARD SEAT TRACK NR 1 REPLACED AS PER 53-01-06.SDR SIMA20170328004Light · crackedLT EMERGENCY LIGHT EXTRUSION NR 1 AND NR 3 CRACKED. REMOVED AND REPLACED LT EMERGENCY LIGHT EXTRUSION NR 1 AND NR 3 IAW AMM 33-50-12. SEE NRTC BOW246051 FOR INSTALLATIONSDR ASOA201703285029Battery Pack · dischargedDURING SCHEDULED MX INSPECTION THE ROW 18 TOP CENTER AISLE FORWARD EMERGENCY SIGN WILL NOT ILLUMINATE. MX REMOVED AND REPLACED THE NR 4 BATTERY PACK WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20170328002Shutoff Valve · failedBLD 2 VALVE FAIL THEN PHL LANDING A/I INOP. THEN A/I FAIL IN CLOUDS W/ICE COND AT 12000 ON CLIMBOUT. REMOVED AND REPLACED E-2 PRSOV IAW AMM CH 36-11-05 OPS CK GOODSDR SIMA20170328003Light · inoperativeSERVICE DOOR SWING ARM COVER EMERGENCY LIGHT INOP. R&R SERVICE DOOR SWING ARM EMERGENCY LIGHT LAMP IAW AMM 33-50-09. OPC GOOD.SDR HNAA2017032900097Warning Message · false activationDURING FLIGHT IN ICING CONDITIONS, AN EICAS MESSAGE FOR THE STAB ANTI-ICE FAILED, FOLLOWED BY A WARNING MESSAGE. GROUND RAN THE ACFT AND PERFORMED AN ANTI ICE VALVE TEST IAW AMMM 30-21-00-700-804-A/500, NO DEFECTS NOTED AT THIS TIME. OK FOR SERVICE.SDR SIMA20170327003Frame · crackedFRAME 73 CRACKED AT STRINGER 16R-17R. REPAIRED FR 73 AT STRINGER 16R-17R IAW SRM 53-31-04.SDR SIMA20170327002Profile · corrodedSERVICE DOOR UPPER AND LOWER U PROFILES NUTPLATE HOLES CORROSION. REPAIRED SERVICE DOOR UPPER AND LOWER U PROFILES NUTPLATE HOLES CORROSION IAW ERS-EM-52MR-720.SDR ASOA201703275028Control Unit · faultyPILOT REPORTED INBOARD BRAKES DID NOT WORK ON LANDING BOTH TEMP PROBES SHOWING COLD AND COLD TO THE TOUCH. MX REMOVED AND REPLACED BCU WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR HNAA2017032900098Unknown · odorSTRONG FUEL ODOR IN COCKPIT AND CABIN WHEN APU IS STARTED. INSPECTED THE APU FUEL LINES AND SURROUNDING AREAS WHILE APU RUNNING. NO DEFECTS OR LEAKS NOTED. NO ODOR IN CABIN AT THIS TIME. OK FOR SERVICE.SDR SIMA20170327001Valve · faultyNR 1 BLEED OVERTEMP. REMOVED AND REPLACED NR 1 FAN AIR VALVE IAW AMM 36-11-03. OPS CK GOOD IAW AMM 36-00-00 LEAK CK GOODSDR ASOA201803264017Unknown · odorFLIGHT 4454 THE CREW REPORTED AN ELECTRICAL TYPE ODOR AROUND THE GALLEY AREA. OPENSDR SIMA20170326010Profile · corrodedSERVICE DOOR CORRODED AROUND LOWER NUTPLATE HOLES. REPAIRED SERVICE DOOR LOWER PROFILE IAW ERS-EM-52MR-739.SDR SIMA20170326011Frame · chafedSERVICE DOOR FWD FRAME WEB PAINT DAMAGED BTW NR 3 AND NR 5 STOP. REPAIRED SERVICE DOOR FWD FRAME WEB CHAFE BTW NR 3 AND NR 5 STOP IAW ERS-EM-52MR-738.SDR SIMA20170326009Cup · corrodedDURING IMBV INSPECTION, QA FOUND THE TOILET WASTE DRAIN VALVE CUP CORRODED. AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE VALVE CUP IAW SRM 51-40-02, 51-20-01, 51-40-06, AND 51-20-03.SDR SIMA20170326008Skin · dentedDURING IMBV INSPECTION, QA FOUND A DENT BELOW GPU DOOR. AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED THE SKIN IAW SRM 53-11-01RE, ITEM 2.SDR SIMA20170326006Connector · out of positionEMERGENCY EXIT SIGN ON CEILING ABOVE 1A INOP. CORRECTLY ARRANGED CONNECTORS ON CEILING PANEL 233 BLC IAW AMM 25-22-04 AND 33-50-15.SDR SIMA20170326007Connector · out of positionEMERGENCY EXIT SIGN UNDER COCKPIT DOOR INOP. CORRECTLY ARRANGED CONNECTORS ON CEILING PANEL 233 BLC IAW AMM 25-22-04 AND 33-50-15.SDR SIMA20170326005Connector · intermittentEMERGENCY EXIT FLOOR STRIP BTW 1A AND 2A INTERMITTENT. CORRECTLY ARRANGED CONNECTORS ON CEILING PANEL 233 BLC IAW AMM 25-22-04 AND 33-50-15.SDR SIMA20170326004Light · inoperativeEMERGENCY EXIT FLOOR STRIP BTW 8A AND 9A INOP. REMOVED AND REPLACED EMERGENCY EXIT FLOOR STRIP BTW 8A AND 9A IAW AMM 33-50-12.SDR SIMA20170326003Connector · intermittentEMERGENCY EXIT SIGN BOTTOM LEFT OF SERVICE DOOR INTERMITTENT. CORRECTLY ARRANGED CONNECTORS ON CEILING PANEL 233 BLC IAW AMM 25-22-04 AND 33-50-15.SDR ASOA201703265024Smoke Warning · false activationPILOT REPORTED LAV SMOKE MESSAGE ON CLIMB-OUT LASTED ABOUT TWO MINUTES THEN DISAPPEARED. CONTRACT MX PREFORMED LAV SMOKE TEST WITH NO FAULTS FOUND THIS TIME. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20170326002Rib · crackedSHEET METAL UNDER NR 2 WING LOOKS CRACKED BY WHEEL WELL. INSPECTED A/C AND FOUND 5.5" CRACK ON RT MLG AFT RIB PN 145-72166-002 ITEM TRANSFERRED TO LOG PAGE 4069199 ITEM 1. C/W PERMANENT REPAIR ON RT MLG AFT RIB IAW ERS-EM-5300-2647.SDR SIMA20170326001Battery Pack · inoperativeNR 2 AND 3 FLOOR EMERGENCY LIGHTS DID NOT ILLUMINATE. REMOVED AND REPLACED BATTERY AND CHARGER ASSEMBLY IAW 33-700-19. OPS CHECKED GOOD IAW 33-700-17. NO DEFECTS FOUND.SDR HNAA2017032700096Circuit Breaker · trippedPITCH TRIM MAIN INOPERATIVE EICAS MESSAGE DURING CLIMB, FOUND THE CIRCUIT BREAKER TRIPPED. RESET THE CIRCUIT BREAKER C9 AND OPS CHECKED IAW AMM 27-40-00-700-802-A. OPS CHECKED GOOD. OK FOR SERVICE.SDR SIMA20170325007Skin · crackedLT REAR FUSELAGE I SKIN CRACKS AT FRAME 75 AFT OF FRAME ABOVE 2L AND FIRST FASTENER BELOW STRINGER 2L. PERFORMED PERMANENT REPAIR OF LT REAR FUSELAGE I SKIN AT FRAME 75 IAW SRM 53-31-01.SDR SIMA20170325006Frame · gougedDURING IMBV INSPECTION, QA FOUND FRAME 68 GOUGED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED THE FRAME IAW ERS-EM-53MR-2634.SDR SIMA20170325005Frame · gougedDURING IMBV INSPECTION, QA FOUND FRAME 65 GOUGED AT NUT PLATE HOLE ON RT SIDE JUST ABOVE FLOOR LEVEL. AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED THE FRAME IAW ERS-EM-53MR-2636.SDR SIMA20170325004Frame · crackedFRAME 73 CRACKED AT STRINGER 17R. REPAIRED FR 73 AT STRINGER 17R IAW ERS-EM-53MR-2638 PART A.SDR ASOA201703254012Battery Pack · dischargedMAINTENANCE REPORTED THAT THE NR 1 & 2 OVERWING EMERGENCY LIGHTS AND AFT INTERIOR EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACK, OPERATIONALLY TESTED WITH NO DEFECTS NOTESDR ASOA201703254011Power Supply · inoperativeMAINTENANCE REPORTED THAT THE NR 1 & 2 OVERWING EMERGENCY LIGHTS AND AFT INTERIOR EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACK, OPERATIONALLY TESTED WITH NO DEFECTS NOTSDR SIMA20170325002Inverter · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE NR 1 INVERTER IAW AMM 33-50-11 OPS CHECKED GOOD.SDR HNAA2017032700095Line · crackedEICAS MESSAGE. ANTI-ICE FAILED. DOWNLOAD SHOWED WING ANTI-ICE FAILED MESSAGE.FOUND LEFT WING REFERENCE LINE CRACKED. R & R THE LINE, OPS CHECKED GOOD, OK FOR SERVICE.SDR SIMA20170324006Skin · crackedRT REAR FUSELAGE I SKIN CRACK AT FRAME 75, AND STRINGER 2R. PERFORMED PERMANENT REPAIR OF RT REAR FUSELAGE I SKIN AT FRAME 75 AND STR 2R IAW SRM 53-31-01.SDR SIMA20170324005Inverter · failedEMERGENCY LIGHTS AND NR 2 EPSU INOPERATIVE. R & R NR 2 EMERGENCY LIGHT POWER SUPPLY INVERTER IAW AMM 33-50-11-000-801-A, & 33-50-11-400-801-A, OPS CHECKED GOOD.SDR SIMA20170324004Inverter · inoperativeFIRST SET OF AISLE FLOOR LIGHTS AND LOWER SERVICE DOOR LIGHT INOPERATIVE. REMOVED AND REPLACED NR 2 INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD.
Back to Embraer EMB-145LR