Embraer EMB-145LR

Service difficulty reports · 36,797

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SIMA20160731001Valve · failedHIGH STAGE VALVE 1 FAILED ON DECENT, LATER CLEARED. NOTICED POSSIBLE OIL IN PACK, ODOR. RT ENGINE 1 HIGH STAGE VALVE IAW AMM 36-11-02. OPS AND LEAKS CHECK GOOD. SEE ITEM 1, LOG PAGE 4010164 FOR POSSIBLE OIL AND PACK SMALL. PERFORMED ENGINE ODOR EVENT TROUJul 31, 2016 · N653AE · Emb EMB145LR · Pneumatic Distribution SystemSDR SIMA20160730003Floor Support · corrodedCABIN CENTER OMEGA BEAM CORRODED AT NUTPLATE HOLE JUST FWD OF CENTER AISLE CROSSBEAM BETWEEN FRAMES 24-25. PERFORMED REPAIR OF CABIN CENTER OMEGA BEAM AT NUTPLATE HOLE JUST FWD OF CENTER AISLE CROSSBEAM IAW SRM 53-22-10.Jul 30, 2016 · N909AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160730004Door Sill · corrodedCARGO DOOR CUTOUT LOWER SILL CORRODED. REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER SILL IAW SRM 51-40-02Jul 30, 2016 · N909AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160730005Angle · crackedRIGHT OMEGA BEAM INBD SUPPORT IS CRACKED BETWEEN FRAMES 47-48. REPAIRED IAW SRM 53-23-02, 51-20-03, AND 51-40-02.Jul 30, 2016 · N909AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201607300001Duct · detachedAT APPROXIMATELY 4000 FT, LOUD BANG HEARD FOLLOWED BY CALL FROM F/A REPORTING SMOKE IN CABIN AT ROW 9. INSPECTED AREA UNDER FLOORBOARDS IN CABIN AT ROW 9 AND FOUND RECIRC FAN MUFFLER NOT ATTACHED. RESECURED DUCT IAW AMM 21-20-01. NO SMOKE DETECTED, ONLY WATJul 30, 2016 · N621AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20160730001Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. R AND R SERVICE DOOR EMERGENCY LIGHT LAMP IAW AMM TASK 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD.Jul 30, 2016 · N668HH · Emb EMB145LR · Emergency LightingSDR SIMA20160729002O-Ring · damagedBLD 2, LEAK AFTER TAKEOFF. R & R BLEED LINE O-RINGS AT 18 AND 23 IAW AMM 36-11-10, 36-11-09. CHECK GOOD, NO LEAKS NOTED.Jul 29, 2016 · N905JH · Emb EMB145LR · Pneumatic Distribution SystemSDR SIMA20160729004Light · inoperativeCOCKPIT EMERGENCY LIGHT LAMP BURNED OUT. R & R COCKPIT EMERGENCY LIGHT LAMP. OPC GOOD IAW 33-50-05.Jul 29, 2016 · N908AE · Emb EMB145LR · Emergency LightingSDR SIMA20160729005Flashlight · inoperativeFORWARD F/A FLASHLIGHT NOT CHARGING. R & R FOWARD F/A FLASHLIGHT IAW AMM 33-50-16.Jul 29, 2016 · N603KC · Emb EMB145LR · Emergency EquipmentSDR SIMA20160729003Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R MAIN CABIN DOOR EMERGENCY LIGHT LAMP IAW AMM 33-50-06-000-801-A AND 33-50-06-400-801-A. OPC GOOD AT THIS TIME.Jul 29, 2016 · N632AE · Emb EMB145LR · Emergency LightingSDR SIMA20160729001Wire · damagedNR 1 EMEGENCY LIGHT STRIP WIRES TORN OFF. FOUND ON CLOSE-UP. R & R NR 1 EMERGENCY LIGHT STRIP IAW AMM 33-50-12Jul 29, 2016 · N908AE · Emb EMB145LR · Light System WiringSDR SIMA20160728008Light · damagedNR 5 LT EMERGENCY LIGHT IS DAMAGED. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-50-12.Jul 28, 2016 · N655AE · Emb EMB145LR · Emergency LightingSDR SIMA20160728007Trunnion · crackedRT MLG AFT UPPER TRUNNION CRACKED. CRACK VERIFIED BY HFEC INSPECTION. REMOVED AND REPLACED THE MLG AFT UPPER TRUNNION IAW ERS-EM-57MR-678.Jul 28, 2016 · N655AE · Emb EMB145LR · Wing, Landing Gear Attach FittingsSDR SIMA20160728006Skin · chafedFUSELAGE EXTERNAL SKIN CHAFED INSIDE RT PYLON PANEL 424DB FWD OF CONNECTOR J0816. PERFORMED REPAIR OF THE SKIN AREA IAW SRM 53-31-01.Jul 28, 2016 · N655AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160728005Shear Tie · corrodedCARGO DOOR CUTOUT FRAME 65 SHEAR TIE CORRODED AT LOWER END. REPAIRED THE SHEAR TIE IAW SRM 53-31-04 AND ETN EM-53-272Jul 28, 2016 · N909AE · Emb EMB145LR · Fuselage Internal Mounting StructureSDR SIMA20160728004Crossbeam · corrodedFRAME 20 AISLE CROSSBEAM CORRODED. REMOVED AND REPLACED THE CROSSBEAM IAW SRM 53-21-10 AND ETN-EM-53-139 R4.Jul 28, 2016 · N909AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20160728001Power Supply · failedEMERGENCY LIGHTS IN COCKPIT, CEILING, AISLE CEILING, AND LT EXTERIOR FWD WING LIGHTS INOPERATIVE. REMOVED AND REPLACED THE NR 1 EPSU IAW WC 33-700-19. OPS CHECKED GOOD IAW 33-700-17.Jul 28, 2016 · N653AE · Emb EMB145LR · Emergency LightingSDR ASOA20160727039Unknown · odorCREW REPORTED A STRONG TOXIC, OILY ODOR FROM NR 1 PACK IN FLIGHT DECK. MX PERFORMED OPS CHECK OF THE NR 1 PACK WITH NO UNUSUAL ODORS AND OPS CHECKED GOOD. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.Jul 27, 2016 · N13538 · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20160725005Valve · corrodedTOILET WASTE VALVE SUPPORT BUCKET IS CORRODED. REMOVED AND REPLACED TOILET WASTE VALVE SUPPORT BUCKET IAW SRM 51-40-02Jul 25, 2016 · N600BP · Emb EMB145LR · Waste Disposal SystemSDR SIMA20160725003Bleed Valve · malfunctionedBLEED 1 VALVE CLOSED ADVISORY ON CLIMB OUT.PERFORMED AOM1 PROCEDURE. REMOVED AND REPLACED BLEED 1 PBA IAW AMM 20-13-04. BLEED OPERATIONAL CHECKED GOOD IAW AMM 36-11-05.Jul 25, 2016 · N647AE · Emb EMB145LR · Compressor Bleed ValveSDR SIMA20160725002Charger · failedDURING PS-1 INSPECTION, FOUND LAST THREE EMERGENCY FLOOR LIGHT STRIPS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHTING BATTERY AND BATTERY CHARGER ASSEMBLY IAW AMM 33-50-04. OPS CHECKED GOOD.Jul 25, 2016 · N647AE · Emb EMB145LR · Emergency LightingSDR SIMA20160724003Switch · lack of lubeSERVICE DOOR INDICATION SHOWS OPEN WHEN CLOSED. DEFERRED SERVICE DOOR WARNING SYSTEM REF MEL 52-04, AUTH 070580-B. ACCOMPLISHED CLEANING AND LUBRICATION OF SERVICE DOOR MICROSWITCHES, OPS CHECK GOOD IAW AMM 52-74-00.Jul 24, 2016 · N644AE · Emb EMB145LR · Door Warning SystemSDR SIMA20160724007Skin · crackedLEFT UPPER FUSELAGE SKIN CRACKED JUST AFT OF FRAME 75 AND ABOVE STRINGER 2L, CRACK IS APPROX. 3/8" LONG. REPAIRED THE SKIN IAW SRM 53-31-01 REV 54.Jul 24, 2016 · N908AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160724006Structure · corrodedTHE LAV BUCKET IS CORRODED. REMOVED AND REPLACED THE LAV BUCKET IAW SRM 51-40-02.Jul 24, 2016 · N908AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20160724005Skin · crackedRIGHT UPPER FUSELAGE SKIN CRACKED JUST AFT OF FRAME 75 AND ABOVE STRINGER 2R, CRACK IS APPROX. 3/8" LONG. REPAIRED THE SKIN IAW SRM 53-31-01 REV 54.Jul 24, 2016 · N908AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160724002Display · failedFO'S MFD WENT DARK ENROUTE AND THEN SMELLED AN ACRID ELECTRICAL ODOR THAT LASTED A FEW MINUTES. AFTER 15 MINS FO'S MFD CAME BACK ON-C/A-REMOVED AND REPLACED FOS MFD OPC GOOD IAW EMB AMM 31-22-01Jul 24, 2016 · N900AE · Emb EMB145LR · Flight Management Computing Hardware SystemSDR SIMA20160723004Wire · damagedEMERGENCY LIGHT INOPERATIVE. REPAIRED THE WIRE IAW SWPM 20-21-00 AND AMM 33-50-12. OPS CHECKED GOOD.Jul 23, 2016 · N908AE · Emb EMB145LR · Light System WiringSDR SIMA20160723003Roller · lack of lubeFA STATED THAT THE MAIN CABIN DOOR WAS STICKING. DIFFULCT TO OPEN. LUBRICATED ROLLERS IAW TASK 53-21-02-400. NO OTHER DEFECTS NOTED AT THIS TIME.Jul 23, 2016 · N647AE · Emb EMB145LR · Passenger/Crew DoorsSDR ASOA20160723038RDisplay · odorCREW REPORTED THE FLIGHT DECK SMELLS OF ROTTEN FISH AND SPOILED MILK. ODOR INTENSIFIED AFTER FLIGHT IS COMPLETED. MX FOUND ODOR FROM FO'S PFD. REMOVED AND REPLACED THE PFD, OPS CHECKED GOOD AND NO FURTHER EVIDENCE OF ODOR. ACFT WAS APPROVED FOR RETURN TO SJul 23, 2016 · N14905 · Emb EMB145LR · Attitude and Direction Data SystemSDR SIMA20160722001Hydraulic Line · chafedHYD SYS 1 QTY WENT TO ZERO. HYD SYS 1 FAIL, RAN LIST, EMERGENCY LANDING GEAR EXTENSION. FOUND NR 1 HYDRAULIC PUMP PRESSURE LINE CHAFED. R & R PRESSURE HOSE IAW MM 29-10-03. NO LEAKS NOTED AT THIS TIME.Jul 23, 2016 · N939AE · Emb EMB145LR · Hydraulic System, MainSDR SIMA20160723001Acm · failedNOTICED BURNED ODOR FUMES IN COCKPIT AND CABIN WHEN OPERATING PACK 1 USING THE APU AT THE GATE. DETERMINED ODOR FROM NR 1 PACK AND DEFERRED NR 1 PACK. MEL REF 21-30 AUTH 070552D-C. R & R NR 1 PACK ACM IAW AMM 21-51-03. OPS CHECK GOOD. MEL 2130 RESTORED.Jul 23, 2016 · N918AE · Emb EMB145LR · Cabin Cooling SystemSDR ASOA20160722037Bulb · arcedPILOT REPORTED AN ELECTRICAL BURNING ODOR COMING FROM THE LAVATORY. REMOVED THE LIGHT BULB AND DISCONNECTED FROM BALLAST. REPLACED LAVATORY LIGHT BULBS WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Jul 22, 2016 · N14905 · Emb EMB145LR · Passenger Compartment LightingSDR SIMA20160722002Charger · failedLEFT FORWARD OVERWING EMERGENCY LIGHT INOPERATIVE. T/S AND FOUND THERE WAS NO VOLTAGE AT CONNECTOR PLUG. R & R NR 1 EMERGENCY BATTERY AND POWER SUPPLY IAW W/C 33-700-19. OPC GOOD AT THIS TIME. EMERGENCY LIGHTING BATTERY, PN 2013-1ASMI, SN 82630.Jul 22, 2016 · N653AE · Emb EMB145LR · Emergency LightingSDR SIMA20160720011Battery · dischargedALL EMERGENCY LIGHT BATTERIES ARE DEAD. R & R ALL EMERGENCY LIGHT BATTERY ASSEMBLIES IAW WC 33-700-19, OPS CK GOOD. BATTERY CHARGER ASSY, PN 11-0049, SN 18284, NR 4; SN 13704, NR 3; SN 20134, NR 2; PN BA5-0933-901, SN C02557, NR 1 EMERGENCY LIGHTING BATTERYJul 20, 2016 · N690AE · Emb EMB145LR · Emergency LightingSDR SIMA20160720010Skin · damagedDAMAGED SKIN PANEL. REMOVED AND REPLACED DAMAGED THE SKIN PANEL IAW SRM 51-40-02. MAJOR REPAIR.Jul 20, 2016 · N690AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160720008Door Sill · corrodedLOWER CARGO DOOR SILL HAS CORROSION. R & R CARGO DOOR CUTOUT LOWER SILL IAW SRM 51-40-02.Jul 20, 2016 · N908AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160720006Wire · brokenNR 1 EMERGENCY LIGHT HAS A BROKEN WIRE. REMOVED AND REPLACED THE EMERGENCY LIGHT STRIP IAW AMM 33-50-12.Jul 20, 2016 · N600BP · Emb EMB145LR · Light System WiringSDR SIMA20160720004Floor Support · crackedLEFT OMEGA BEAM IS CRACKED AT NUTPLATE HOLE ABOVE FRAME 69. REPAIRED THE OMEGA BEAM IAW ERS-EM-53MR-2199Jul 20, 2016 · N600BP · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160720007Wire · brokenLEFT NR 1 EMERGENCY LIGHT CONNECTION BROKEN. REPAIRED THE WIRE IAW SWPM 20-50-00Jul 20, 2016 · N600BP · Emb EMB145LR · Light System WiringSDR SIMA20160720005Skin · damagedRUDDER LOWER RT SIDE TRAILING EDGE SKIN HAS A BLEND-OUT AREA. ACCOMPLISHED PERMANENT REPAIR OF THE RUDDER IAW ERS-EM-55MR-441Jul 20, 2016 · N600BP · Emb EMB145LR · Rudder, Plate/SkinSDR SIMA20160720001Acm · seizedCRUISE ALTITUDE OF 25000 FT, DENSE SMOKE THRU COCKPIT VENTS AS WELL AS CABIN. SMOKE CLEARED AT 18000 FT. FOUND NR 2 ACM SEIZED. REMOVED AND REPLACED NR 2 ACM IAW MM 21-51-03. OPS AND LEAK CHECKED GOOD. NO SMOKE NOTED. COMPLIED WITH ENGINE ODOR EVENT T/S PEJul 20, 2016 · N902BC · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20160720002Valve · malfunctionedIN FLIGHT, ACFT PRESSURIZATION WOULD NOT STOP CLIMBING. CABIN WHENT AS HIGH AS 10,000 FT. AUTO MODE WAS CLIMMING AT 1,000 FT + MIN AND WOULD NOT STOP. AUTO MODE AND MANUAL MODES VIRTUALLY UNRESPONSIVE. R & R GROUND CONNECTION VALVE AND SEAL IAW AMM 21-22-0Jul 20, 2016 · N603KC · Emb EMB145LR · Cabin Pressure Control SystemSDR SIMA20160719002Door Sill · corrodedCARGO DOOR LOWER SILL CORRODED. PERFORMED REPAIR IAW SRM 53-31-15 ITEM 2 FIG 202.Jul 19, 2016 · N923AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160719001Flashlight · inoperativeFORWARD CABIN FLASHLIGHT INOPERATIVE. REPLACED FWD CABIN FLASHLIGHT.Jul 19, 2016 · N642AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20160718005Tee Fitting · corrodedCARGO DOOR LOWER SILL AFT TEE BRACKET CORRODED. REMOVED AND REPLACED THE TEE BRACKET IAW SRM 51-40-02, AND 51-20-03.Jul 18, 2016 · N923AE · Emb EMB145LR · Fuselage Main, Attach FittingsSDR RAIA201607180001Solenoid Valve · inoperativeLANDING GEAR DISAGREEMENT MESSAGE. R & R LANDING GEAR SOLENOID VALVE. LEAK CHECK AND GEAR SWING GOOD.Jul 18, 2016 · N811HK · Emb EMB145LR · Landing Gear Retraction/Extension SystemSDR ASOA20160718036Warning Message · false activationPILOT REPORTED EICAS MESSAGE FOR CARGO BAY SMOKE FOR 5 SECONDS, CLIMBING THROUGH 14000 FEET. MX PERFORMED OPS CHECK OF CARGO SMOKE DETECTION SYSTEM WITH NO DEFECTS NOTED. ACFT WAS APPROVED FOR RETURN TO SERVICE.Jul 18, 2016 · N16981 · Emb EMB145LR · Smoke DetectionSDR ASOA20160718042Inverter · inoperativeDURING ROUTINE MAINTENANCE THE LT EMERGENCY EXIT EXIT SIGN WAS FOUND INOPERATIVE. MAINTENANCE REPLACED THE NR 4 EMERGENCY LIGHT DC/AC INVERTER. OPS CHECKS WERE GOOD.Jul 18, 2016 · N14998 · Emb EMB145LR · Emergency LightingSDR SIMA20160718001Light · inoperativeOVERHEAD MAIN DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LIGHT IAW AMM 33-50-06. OPS CHECKED GOODJul 18, 2016 · N693AE · Emb EMB145LR · Emergency LightingSDR SIMA20160718002Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. DISCONNECTED AND CONNECTED EMERGENCY LIGHT FROM BATTERY HARNESS IAW 33-26-05-400-801-A. OPS CHECKED NORMAL.Jul 18, 2016 · N690AE · Emb EMB145LR · Emergency Lighting
Back to Embraer EMB-145LR