Embraer EMB-145LR

Service difficulty reports · 36,797

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASOA20160425018Charger · inoperativeDURING MAINTENANCE INSPECTION THE NR 2 AND NR 3 FLOOR EMERGENCY LIGHT STRIPS WERE FOUND INOPERATIVE. MAINTENANCE R & R NR 3 EMERGENCY LIGHT BATTERY CHARGER AND INVERTER WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 25, 2016 · N15572 · Emb EMB145LR · Emergency LightingSDR ASOA20160427013Skin · dentedDENT LOCATED BETWEEN FRAME 19 AND FRAME 20 AT STR 15L AND 16L. CUTOUT DAMAGED SECTION FABRICATED FILLER AND DOUBLER, INSTALLED AND REFINISHED. ACFT RELEASED AND RETURNED TO SERVICE.Apr 25, 2016 · N15983 · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160425002Fire Detector · failedE2 FIRE DETECTOR FAIL PASSING FL 230. R & R NR 2 ENG FIRE DETECTOR IAW AMM 26-11-01. OPERATIONS CHECKED GOOD.Apr 25, 2016 · N933JN · Emb EMB145LR · Fire DetectionSDR SIMA20160425001Holder · defectiveFIRST OFFICERS FLASHLIGHT NOT SECURE TO FLASHLIGHT BASE. R & R FIRST OFFICERS FLASHLIGHT BASE IAW AMM 33-50-16.Apr 25, 2016 · N601DW · Emb EMB145LR · Emergency EquipmentSDR RAIA201604240001Seal · leakingMAIN CABIN DOOR SEAL EXTREMELY LOUD ON CLIMB OUT. REPAIRED LEAK ON AFT SIDE LOWER PASSENGER DOOR. OPS CHECK GOOD.Apr 24, 2016 · N855HK · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20160423001Bulb · unsecureFORWARD FLIGHT ATTENDANT FLASHLIGHT DOES NOT TURN ON. AT THIS TIME SECURED FWD FLIGHT ATTENDANT FLASHLIGHT BULB. OPERATIONS CHECKED GOOD IAW AMM 33-51-01.Apr 23, 2016 · N939AE · Emb EMB145LR · Emergency EquipmentSDR ASOA20160423037Ballast · inoperativeTHE CREW REPORTED THAT THE SIDEWALL LIGHTS AT SEAT 1A HAD AN ELECTRICAL ODOR. THE ACFT LANDED WITHOUT INCIDENT. WHERE MAINTENANCE R & R THE SIDEWALL LIGHT BALLAST AT SEAT 1A, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TApr 23, 2016 · N14543 · Emb EMB145LR · Passenger Compartment LightingSDR ASOA20160423021Fitting · crackedDURING C-CHECK, THE RT ENGINE LOWER FWD MOUNT YOKE FITTING WAS FOUND TO BE CRACKED. MAINTENANCE R & R THE FITTING IAW EC5450-01199. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 23, 2016 · N29917 · Emb EMB145LR · Engine Mount SectionSDR ASOA20160422017Unknown · odorF/A REPORTED ELECTRICAL ODOR IN CABIN. NO OBSERVED SMOKE, NO ODOR IN COCKPIT. MAINTENANCE PERFORMED OPS CHECK OF AIR DISTRIBUTION SYS AND COULD NOT DUPLICATE ODOR. ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 22, 2016 · N13908 · Emb EMB145LR · Air Distribution SystemSDR SIMA20160422002Control Unit · failedPTRIM MAIN INOPERATIVE WARNING ON CLIMB OUT. R & R HORIZONTAL STABILIZER CONTROL UNIT IAW AMM 27-40-01. OPERATIONS CHECKED GOOD.Apr 22, 2016 · N659AE · Emb EMB145LR · Stabilizer Control SystemSDR SIMA20160420002Skin · crackedRIGHT UPPER FUSELAGE SKIN CRACKED, CRACK IS AT THE FIRST FASTENER BELOW STRINGER 2R ON FRAME 75, CRACK IS 1/4" LONG. PERFORMED REPAIR AT RT UPPER FUSELAGE SKIN CRACK AT FIRST FASTENER, BELOW STRINGER 2R ON FRAME 75, ERS-EM-53MR-2099. SEE TASKS & WIPS FOR DETApr 20, 2016 · N647AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160420001Inverter · inoperativeRIGHT OVERWING EMER EXIT SIDEWALL EXIT SIGN INOPERATIVE. R & R EMER LIGHT INVERTER NR 5 IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.Apr 20, 2016 · N918AE · Emb EMB145LR · Emergency LightingSDR SIMA20160418004Frame · corrodedFRAME 22 IS CORRODED BELOW SERVICE DOOR LOWER FRAME STOP. REPAIRED FRAME 22 IAW ERS-EM-53MR-2053.Apr 18, 2016 · N636AE · Emb EMB145LR · Fuselage Main, FrameSDR ASOA20160418022Power Supply · inoperativeDURING ROUTINE MAINTENANCE THE AFT OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. MAINTENANCE REPLACED THE NR 4 EMERGENCY BATTERY POWER SUPPLY. OPS CHECKS WERE GOOD.Apr 18, 2016 · N11535 · Emb EMB145LR · Emergency LightingSDR SIMA20160417001Flashlight · inoperativeCAPTAIN FLASHLIGHT INOPERATIVE. R & R CAPTAINS FLASHLIGHT IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.Apr 17, 2016 · N646AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20160417002Inverter · inoperativeTHREE AFT EMER FLOOR LIGHT STRIPS INOPERATIVE. R & R NR 6 EMER LIGHT DC & AC INVERTER. OPERATIONS CHECKED GOOD FOR ALL EMER FLOOR LIGHT STRIPS IAW AMM 33-50-11.Apr 17, 2016 · N600BP · Emb EMB145LR · Emergency LightingSDR SIMA20160416004Connector · looseAFTER TAKEOFF, ELEC EMER ABNORM, ON EICAS. ACCOMPLISHED THE CHECKLIST & LANDED AT AIRPORT. ELEC EMER ABNORM, MSG REMAINED ON THROUGHOUT FLIGHT. EMER LIGHT NOT ARMED, MSG ALSO ON FOR FLIGHT. BOTH MSGS CAME ON AFTER TAKEOFF. TIGHTENED CONNECTOR P1153, BATTEApr 16, 2016 · N941LT · Emb EMB145LR · Electrical Power System WiringSDR SIMA20160416003Light · inoperativeRIGHT LOWER EMER LIGHT INOPERATIVE. R & R RT EXTERNAL LOWER EMER LIGHT IAW AMM 33-50-10-000-801 & 33-50-10-400-801. OPERATIONS CHECKED GOOD.Apr 16, 2016 · N654AE · Emb EMB145LR · Emergency LightingSDR SIMA20160416002Battery · dischargedSEVERAL EMER LIGHTS INOPERATIVE. R & R NR 2 EMER BATTERY & CHARGER. OPERATIONS CHECKED GOOD IAW AMM 33-50-04. BATTERY CHARGER ASSEMBLY, PN 11-0049 & SN 18196.Apr 16, 2016 · N639AE · Emb EMB145LR · Emergency LightingSDR UHLA201604150178Wire Harness · damagedMAIN DOOR EICAS INDICATION INOP WHEN DOOR IS CLOSED. VERIFIED CLOSED. R & R MAIN ENTRY DOOR HARNESS IAW AMM 20-10-01, AMM 52-73-01. OPS CHECK GOOD.Apr 15, 2016 · N281SK · Emb EMB145LR · Door System WiringSDR SIMA20160415001Battery · dischargedEXTERNAL OVERWING EMER LIGHTS INOPERATIVE. TROUBLE SHOT IAW FIM TASK 33-50-00-810-804-A. FOUND NR 4 BATTERY & CHARGER TO BE BAD. R & R NR 4 BATTERY & CHARGER IAW WC 33-700-19. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED AT THIS TIME ENDS. EMER LIGHT BATTERYApr 15, 2016 · N941LT · Emb EMB145LR · Emergency LightingSDR SIMA20160414008Skin · corrodedSSI 53-30-07 CARGO UNDER FLOOR SKIN IS CORRODED ON BOTH SIDES OF FRAME 67, BETWEEN STRINGERS 21L - 21R. ACCOMPLISHED REPAIR TO CARGO UNDER FLOOR SKIN IAW ERS-EM-53MR-2017.Apr 14, 2016 · N640AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR RAIA201604140001Bulb · inoperativeRIGHT AFT WING, FUSLAGE FAIRING EXTERIOR FLOOD LIGHT, NR 6 INOPERATIVE. R & R RT AFT WING/FUSLAGE FAIRING EXTERIOR FLOOD LIGHT NR 6 BULB. OPS CHECKED GOOD.Apr 14, 2016 · N855HK · Emb EMB145LR · Emergency LightingSDR UHLA201604140168Rod · unknownMAIN ENTRY DOOR HARD TO OPEN AND STAIRS NOT DEPLOYING. R & R HASTE CONJUNCTION ROD IAW AMM 52-10-03, OPS CHECK GOOD.Apr 14, 2016 · N270SK · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20160414001Light · inoperativeEMERGENCY LIGHT, BETWEEN ROW 8 - 11 INOPERATIVE. R & R TWO FLOOR PROXIMITY LIGHTING STRIPS AT ROWS 8 -11 IAW MM CH 33-50-12. R & R DAMAGED FEMALE CONNECTOR AT ROW 11 IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD.Apr 14, 2016 · N900AE · Emb EMB145LR · Emergency LightingSDR SIMA20160414003Pressure Switch · faultyWHILE IN CRUISE WE RECEIVED HYD PUMP 1 FAIL ADVISORY, IT WAS INTERMITTENTLY, COME OFF & THEN ON, DIVERTED. R & R EDP PRESS SWITCH IAW AMM 29-10-19. OPERATIONS CHECKED GOOD.Apr 14, 2016 · N697AB · Emb EMB145LR · Hydraulic System, MainSDR SIMA20160414004Light · inoperativeLEFT OVERWING PANEL EMER LIGHT INOPERATIVE. R & R IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.Apr 14, 2016 · N604AE · Emb EMB145LR · Emergency LightingSDR SIMA20160414005Light · inoperativeEMERGENCY FLOOR PROXIMITY LIGHT STRIP, FOURTH FROM FRONT INOPERATIVE. DEFERRED IAW MEL 33-30. R & R EMER FLOOR PROXIMITY LIGHT STRIP, 4TH FROM FRONT IAW AMM 33-50-12. OPERATIONS CHECKED GOOD. MEL ITEM RESTORED.Apr 14, 2016 · N600BP · Emb EMB145LR · Emergency LightingSDR SIMA20160413008Door Frame · corrodedSSI 53-20-07 FRAME 22 IS CORRODED BELOW SERVICE DOOR LOWER FRAME STOP. REPAIRED CORROSION BELOW SERVICE DOOR LOWER FRAME STOP AT CTR FUSELAGE I IAW ERS-EM-53MR-2053. SEE WIPS & TASKS FOR DETAILS OF WORK PERFORMED.Apr 13, 2016 · N636AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20160413007Hinge · corrodedPASSENGER DOOR UPPER NUTPLATE HOLES HAVE SURFACE CORROSION. ACCOMPLISHED PERMANENT REPAIR OF PAX DOOR UPPER NUTPLATE HOLES IAW ERS-EM-52MR-530.Apr 13, 2016 · N640AE · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20160413006Unknown · fumes10 - 15 MINS AFTER TAKEOFF ELEC FUMES CAME INTO THE COCKPIT. THE SMELL WOULD COME THEN DISSIPATE DIVERTED, LANDED UNDERWEIGHT CAN STILL SMELL FUMES IN THE COCKPIT. NO SMOKE OBSERVED, NO FUMES WERE SMELLED IN THE CABIN, COCKPIT ONLY. COMPLIED WITH RECIRCULATApr 13, 2016 · N900AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20160413005Uplock · failedUPON GEAR RETRACTION, LT MAIN & NOSE GEAR RETRACTED NORMALLY. RT MAIN SHOWED IN TRANSIT & UNSAFE INDICATION WITH A LOUD THUMPING SOUND COMING FROM FUSELAGE BEHIND THE COCKPIT. SIMILAR WRITE UP ON LOG PAGE 4013565. R & R RT UPLOCK OX IAW AMM 32-33-10. OPERAApr 13, 2016 · N609DP · Emb EMB145LR · Landing Gear Retraction/Extension SystemSDR HNAA2016041500105Unknown · odorCREW REPORTS ODOR FROM LT ELECTRICAL DISTRIBUTION PANEL AREA. INSPECTED ELECTRICAL DISTRIBUTION PANEL AREA AND ASSOCIATED WIRING C/N/D AFTER POWERING UP SEVERAL TIMES. OK FOR SERVICE.Apr 13, 2016 · N627AE · Emb EMB145LR · Air Distribution SystemSDR HNAA2016041500104Warning Light · false activationBAGGAGE DOOR OPEN INDICATION ON T/O ROLL. ABORTED T/O, RETURN TO GATE AND CONFIRMED DOOR CLOSED.Apr 13, 2016 · N641AE · Emb EMB145LR · Door Warning SystemSDR SIMA20160413002Door Sill · corrodedCARGO DOOR CTR SILL CORRODED AT FRAME 66. REPAIRED CARGO DOOR CTR SILL IAW SRM 51-40-02 & SRM 51-20-01.Apr 13, 2016 · N932AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160413003Cradle · brokenPASSENGER CABIN AFT EMER FLASHLIGHT CRADLE IS BROKEN. R & R FLASHLIGHT ASSEMBLY IAW AMM 33-50-16. OPERATIONAL CHECKED GOOD.Apr 13, 2016 · N664MS · Emb EMB145LR · Emergency EquipmentSDR RAIA201604120001Light · misinstalledRIGHT OUTER OVERWING EMERGENCY LIGHT IS UPSIDE DOWN. CORRECTLY REPOSITIONED RT OUTER OVERWING EMERGENCY LIGHT.Apr 12, 2016 · N614AE · Emb EMB145LR · Emergency LightingSDR SIMA20160412001Light · malfunctionedEMERGENCY LIGHTS AT ROWS 1 - 5 DO NOT ILLUMINATE. RESET EMER LIGHTS & OPERATIONS CHECKED GOOD IAW AMM 33-50-00.Apr 12, 2016 · N639AE · Emb EMB145LR · Emergency LightingSDR SIMA20160412002Light · inoperativeLEFT OVERWING EXTERIOR EMER LIGHT INOPERATIVE. RELAMPED LT OVERWING EXTERIOR EMER LIGHT IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.Apr 12, 2016 · N602AE · Emb EMB145LR · Emergency LightingSDR SIMA20160411007Wire · brokenEMERGENCY LIGHT STRIP NR 3, BROKEN WIRE AT BASE ASSEMBLY. FOUND ON CLOSE UP. R & R EMER LIGHT STRIP NR 3 IAW AMM 33-50-12.Apr 11, 2016 · N640AE · Emb EMB145LR · Light System WiringSDR ASOA20160411016RCharger · inoperativeDURING MAINTENANCE INSPECTION, THE EXTERIOR OVERWING EMERGENCY LIGHTS WERE DISCOVERED INOPERATIVE. MAINTENANCE R & R THE NR 4 EMERGENCY LIGHT BATTERY CHARGER WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 11, 2016 · N11544 · Emb EMB145LR · Emergency LightingSDR SIMA20160411005Drain Line · contaminatedFIRST OFFICER AIRSPEED INDICATOR UNRELIABLE, FL 370 CAPTAINS SIDE SHOWS 240, FIRST OFFICERS & STAND BY AGREE DURING DECENT. ALL AIRSPEED INDICATIONS NORMALIZED & WERE READING IN SYNC & NORMAL. FOUND WATER & MOISTURE IN PITOT DRAIN LINE IAW AMM 34-13-00. ADCApr 11, 2016 · N647AE · Emb EMB145LR · Pitot/Static SystemSDR SIMA20160411001Carbon Seal · not reportedA SLIGHT HINT OF OIL SMELL WHEN ICE PROTECTION SYS WAS ACTIVATED. TRANSFERRED TO NRWC 664-ORD-02423. THIS DISCREPANCY TRANSFERED. EM 1 NEXT LOG PAGE FOR AN INTENDED SFP. IAW NRWC 664-ORD-02423 FOR ADDITIONAL MX IFO. R & R NR 0 CARBON SEAL ASSEMBLY IAW R & Apr 11, 2016 · N664MS · Emb EMB145LR · Turbine Engine Oil SystemSDR SIMA20160411003Proximity Switch · failedDEPARTED & UPON GEAR RETRACTION A LOUD CONTINUOUS THUMPING NOISE COULD BE HEARD A LOUD WITH RT MAIN GEAR INDICATION ON EICAS CYCLING, BETWEEN UP & IN TRANSIT EXTENDED GEAR WHICH EXTENDED NORMALLY & LT DOWN. WHEN GEAR HANDLE WAS UP THE LT MAIN & NOSE SHOWED UP Apr 11, 2016 · N609DP · Emb EMB145LR · Landing Gear Position and WarningSDR SIMA20160410001Unknown · odorFUNCTIONAL CHECK FLIGHT REQUIRED DUE TO ELEC BURN SMELL ON APPROACH. ACFT RELEASED FOR FCF PURPOSES ONLY. CHECK FOR PRESENCE OF ELEC ODOR. RAN PACKS OFF, BOTH APU & ENG BLEED AIR FOR 4 HOURS. TURNED ALL LIGHTING & AVIONICS SYSTEMS & PROBE HEATS. NO EVIDENApr 10, 2016 · N907AE · Emb EMB145LR · Air Distribution SystemSDR ASOA20160410034Bulb · burnedTHE CREW REPORTED AN ELECTRICAL BURNING ODOR IN THE CABIN. THE ACFT LANDED WITHOUT INCIDENT. MAINTENANCE R & R THE LIGHT BULB AT SEAT 8A, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 10, 2016 · N14916 · Emb EMB145LR · Passenger Compartment LightingSDR SIMA20160409005Skin · dentedSERVICE DOOR LOWER AFT CORNER DENTED. PERFORMED PERMANENT REPAIR ON SERVICE DOOR AFT CORNER IAW ERS-EM-52MR-531.Apr 9, 2016 · N932AE · Emb EMB145LR · Service DoorsSDR SIMA20160409004Skin · damagedSIX EACH LIGHTNING STRIKES. REPAIR AT FRAME 10 - 12, STRINGER 20R - 21R. PERFORMED PERMANENT REPAIR OF SIX EACH LIGHTNING STRIKES IAW ERS-EM-53MR-2016.Apr 9, 2016 · N932AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR ASOA20160409035HSmoke Detector · defectiveTHE CREW REPORTED A LAV SMOKE WARNING AFTER TAKEOFF WITH NO SMOKE NOTED. THE ACFT CONTINUED TO WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE R & R THE LAV SMOKE DETECTOR, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERApr 9, 2016 · N14923 · Emb EMB145LR · Smoke DetectionSDR SIMA20160409001Light · inoperativeMAIN ENTRANCE OVERHEAD EMER LIGHT INOPERATIVE. R & R MAIN DOOR OVERHEAD EMER LIGHT BULB IAW AMM 33-50-06-000-801-A & 33-50-06-400-801. OPERATIONS CHECKED GOOD.Apr 9, 2016 · N643AE · Emb EMB145LR · Emergency Lighting
Back to Embraer EMB-145LR