Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR HNAA2016041200100Unknown · odorAPU RUNNING, WITH NR 2 ENGINE BLEEDS ON 30 SEC LATER STRONG ODOR IN FLIGHT DECK AND FWD CABIN SHUTOFF BLEEDS AND RECIRCULATING FAN ODOR DISSAPATED. GROUND RAN A/C. C/W FIM 21-20-00-810-801A, NO DEFECTS NOTED. C/W FIG FIM 21-20-00-810-803A, NO ODOR FROM EITHEApr 8, 2016 · N627AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20160408002Light · inoperativeMAIN CABIN DOOR EMER LIGHT INOPERATIVE. R & R MAIN DOOR EMER LIGHT BULB IAW AMM 33-50-10-000-801-A & 33-50-01-400-801-A. OPERATIONS CHECKED GOOD.Apr 8, 2016 · N620AE · Emb EMB145LR · Emergency LightingSDR ASOA20160408017VSkin · crackedDURING C-CHECK THE LT AFT SKIN WAS FOUND TO BE CRACKED AROUND FASTENERS AT FRAME 75 STR 1L-2L. MAINTENANCE PERFORMED A DOUBLER REPAIR IAW EC5330-03099. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 8, 2016 · N29917 · Emb EMB145LR · Fuselage Main, Plate/SkinSDR ASOA20160408016Skin · crackedDURING C-CHECK THE RT AFT SKIN WAS FOUND TO BE CRACKED AROUND FASTENERS AT FRAME 75 AND STRINGERS 2R-3R. MAINTENANCE PERFORMED A DOUBLER REPAIR IAW EC5330-03099. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 8, 2016 · N29917 · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160408001Skin · crackedRIGHT REAR FUSELAGE I SKIN CRACKS AFT OF FRAME 75, BETWEEN STRINGERS 1R & 2R. PERFORMED PERMANENT REPAIR OF RT REAR FUSELAGE I SKIN AFT OF FRAME 75, BETWEEN STRINGERS 1R & 2R IAW ERS-EM-53MR-2008.Apr 8, 2016 · N907AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160407003Floor Support · corrodedFOUND CORROSION ON LT OMEGA BEAM BETWEEN FRAME 33 & 34. REPAIRED LT OMEGA BEAM IAW SRM 53-00-10 FIGURE 202 SHEET 1.Apr 7, 2016 · N640AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160407004Floor Support · corrodedFOUND CORROSION ON CTR OMEGA BEAM BETWEEN FRAME 33 & 34. REPAIRED CTR OMEGA BEAM IAW SRM 53-00-10 FIGURE 203 SHEET 1.Apr 7, 2016 · N640AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160407005Floor Support · corrodedFOUND CORROSION ON LT OMEGA BEAM BETWEEN FRAME 28 & 29. INSTALLED DOUBLER, FILLER, SHIMS ON LT OMEGA BEAM IAW SRM 53-00-10 & 51-40-02.Apr 7, 2016 · N640AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160407007Door Frame · corrodedSERVICE DOOR CUT OUT STRUCTURE LOWER AFT NUTPLATE HOLE PREVIOUS REPAIR HAS CORROSION. INSTALLED EXTERNAL DOUBLER, INTERNAL DOUBLER & FILLER FOR SERVICE DOOR CUT OUT STRUCTURE LOWER AFT NUTPLATE HOLE IAW SRM 53-00-04 FIG 208.Apr 7, 2016 · N640AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20160407006Floor Support · corrodedFOUND CORROSION ON CTR OMEGA BEAM BETWEEN FRAME 28 & 29. INSTALLED DOUBLER, EXTERNAL ANGLE, FILLER, SHIM ON CTR BEAM IAW SRM 53-00-10 & 51-40-02.Apr 7, 2016 · N640AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201604060001Flashlight · inoperativeCAPTAIN`S EMERGENCY FLASHLIGHT WILL NOT TURN ON. R & R CAPTAIN`S FLASHLIGHT, OPS CHECK GOOD.Apr 6, 2016 · N621AE · Emb EMB145LR · Emergency EquipmentSDR ASOA20160406015Fmu · failedPILOT REPORTED A NR 2 ENGINE OUT MESSAGE ENGINE UNCOMMANDED SHUTDOWN, DID NOT INDICATE ON GROUND OR IN FLIGHT. MAINTENANCE INSPECTED AND FOUND DEBRIS IN FUEL FILTER AND BOWL THEN R & R ENGINE NR 2 FMPU WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERApr 6, 2016 · N13992 · Emb EMB145LR · Fuel Controlling SystemSDR SIMA20160406004Light · inoperativeSERVICE DOOR EMER EXIT LIGHT IN DOOR HINGE TRIM COVER INOPERATIVE. R & R SERVICE DOOR EMER EXIT LIGHT LAMP IN DOOR HINGE TRIM COVER IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.Apr 6, 2016 · N654AE · Emb EMB145LR · Emergency LightingSDR SIMA20160406001Fcu · malfunctionedAT CRUISE RECEIVED FUEL IMBALANCE EICAS MSG. LT WING TANK INDICATED ZERO POUNDS FUEL, FUEL FLOW MATCHED RT SIDE FUEL FLOW. INSPECTED ACFT FOR LEAKS, NO LEAKS NOTED. FOUND LT FUEL QTY INDICATION INTERMITTENT. FOUND FCU LT FAIL FAULT CODE ON REPEATER PANEL. Apr 6, 2016 · N652RS · Emb EMB145LR · Fuel Control/Reciprocating EnginesSDR SIMA20160405001Unknown · odorSTRONG ELEC BURNING SMELL WITH NO SIGN OF SMOKE AFTER STARTING BOTH ENGS BEFORE TAXI. DEFERRED PACK ONE. PERFORMED OPERATIONS CHECK OF COOLING PACK SYS IAW AMM TASK 21-51-00-700-802-A. OPERATIONS CHECKED GOOD, PACK 1 SOUNDS, SMELLS & FUNCTIONS NORMALLY. MEApr 5, 2016 · N631AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20160405003Light · brokenRIGHT EXTERIOR EMER LIGHT ABOVE PACK PANEL IS BROKEN. R & R RT EXTERIOR EMER LIGHT ABOVE PACK PANEL IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.Apr 5, 2016 · N652RS · Emb EMB145LR · Emergency LightingSDR ASOA201704044016Skin · gougedDURING MAINTENANCE INSPECTION, THE AIRCRAFT SKIN WAS FOUND TO BE GOUGED UNDER THE GPU DOOR. MAINTENANCE CUT OUT THE DAMAGE AND INSTALLED A DOUBLER AND FILLER REPAIR, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.Apr 4, 2016 · N11548 · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160404003Skin · crackedPOSSIBLE CRACK AROUND RIVET AT FRAME 78, BETWEEN STRINGER 6R - 7R. PERFORMED PERMANENT REPAIR OF RT REAR FUSELAGE I SKIN IAW SRM 53-32-01 REPAIR TYPE B.Apr 4, 2016 · N932AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR ASOA20160404014Smoke Detector · faultyCREW REPORTED A "LAV SMOKE" INDICATION IN FLIGHT. MAINTENANCE R & R LAV SMOKE DETECTOR WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 4, 2016 · N14923 · Emb EMB145LR · Smoke DetectionSDR ASOA20160404032HInverter · inoperativeDURING MAINTENANCE INSPECTION THE NR 4 AND 5 AISLE PATH LIGHTING STRIPS AND EXIT IDENTIFIERS ON THE LT AND RT OVER WING EXIT SHROUDS WERE FOUND TO BE INOPERATIVE. MAINTENANCE R & R THE NR 5 EMERGENCY LIGHT DC/AC INVERTER, OPERATIONALLY TESTED WITH NO DEFECTSApr 4, 2016 · N15574 · Emb EMB145LR · Emergency LightingSDR SIMA20160404002Power Supply · inoperativeLOWER RT OVERWING EMER LIGHT INOPERATIVE. R & R NR 2 EMER LIGHT POWER SUPPLY. OPERATIONS CHECKED GOOD EMB AMM 33-50-04.Apr 4, 2016 · N697AB · Emb EMB145LR · Emergency LightingSDR SIMA20160404001Light · inoperativeMAIN DOOR EXTERNAL EMER LIGHT INOPERATIVE. RELAMPED MAIN DOOR EXTERNAL EMER LIGHT IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.Apr 4, 2016 · N900AE · Emb EMB145LR · Emergency LightingSDR ASOA20160404031Light · inoperativeTHE CREW REPORTED THAT THE AISLE EMERGENCY LIGHTS BETWEEN ROWS 17 & 18 WERE FOUND TO BE INOPERATIVE. MAINTENANCE R & R THE AFFECTED LIGHT STRIP, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 4, 2016 · N673AE · Emb EMB145LR · Emergency LightingSDR SIMA20160403001Power Supply · inoperativeLEFT WING FWD FAIRING EXTERNAL EMER LIGHT INOPERATIVE. R & R BT8500 NR 1 BATTERY POWER SUPPLY. OPERATES OK IAW AMM 33-50-04.Apr 3, 2016 · N692AE · Emb EMB145LR · Emergency LightingSDR ASOA20160402020Battery Pack · dischargedTHE CREW REPORTED EMERGENCY LIGHT ABOVE F/A WAS INOPERATIVE. MAINTENANCE PERFORMED RECHARGE OF EMERGENCY LIGHT BATTERY WITH APU RUNNNING. OPS CHECK OF EMERGENCY LIGHTS WERE GOOD.Apr 2, 2016 · N14920 · Emb EMB145LR · Emergency LightingSDR SIMA20160401005Door · corrodedBAGGAGE DOOR CORROSION AROUND NUTPLATE HOLE, FWD LOWER. REPAIRED BAGGAGE DOOR CORROSION AROUND NUTPLATE HOLE IAW ERS-EM-52MR-513.Apr 1, 2016 · N932AE · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA20160401004Door Frame · corrodedCARGO DOOR CUT OUT UPPER FRAME HAS CORROSION AFT OF FRAME 65. REPAIRED CARGO DOOR UPPER FRAME IAW SRM 51-14-02 & 51-10-03.Apr 1, 2016 · N932AE · Emb EMB145LR · Fuselage Main, StructureSDR UHLA201604010160Step · malfunctionedMED STEPS WILL NOT STOW. R & R STEP SPRING AT STEP 3, OPS CHECK IAW AMM 52-10-01. OPS CHECK GOOD.Apr 1, 2016 · N577RP · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20160401003Transducer · failedABORTED TAKEOFF AT 80KTS. BRAKE DEGRADED MSG & AT THE SAME TIME ACFT SWERVED TO THE LEFT. R & R NR 4 WHEEL SPEED TRANSDUCER IAW AMM 32-41-03. PERFORMED FUNCTIONAL CHECK OF THE MAIN BRAKE SYS IAW AMM TASK 32-41-00-700-801. CHECK IS GOOD.Apr 1, 2016 · N600BP · Emb EMB145LR · Brake Anti-Skid SectionSDR SIMA20160331008Door Sill · corrodedCARGO DOOR CUT OUT LOWER FLOOR SILL CORRODED. INSTALLED SERVICEABLE CARGO DOOR CUT OUT LOWER FLOOR SILL IAW SRM 51-40-02.Mar 31, 2016 · N902BC · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160331007Fitting · corrodedFRAME 68 SHEAR CLIP CORRODED LOWER AFT CORNER OF CARGO DOOR CUT OUT. REPAIRED SHEAR CLIP AT FRAME 68 IAW SRM 53-31-04 & ETN EM-53-272.Mar 31, 2016 · N902BC · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160331006Door Sill · corrodedSERVICE DOOR ENTRANCE SILL CORRODED. REPAIRED SERVICE DOOR ENTRANCE SILL IAW SRM 53-21-02 ITEM 2 FIG 201.Mar 31, 2016 · N932AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20160331004Light · inoperativeAFT CEILING EMER LIGHT INOPERATIVE. R & R AFT CEILING EMER LIGHT LAMP. OPERATIONS CHECKED GOOD IAW AMM 33-50-08.Mar 31, 2016 · N922AE · Emb EMB145LR · Emergency LightingSDR SIMA20160331002Warning Unit · failedTRIPLE CHIME & AURAL TAKEOFF CONFIG TRIM. TAKEOFF CONFIG FLAPS, FROM CLIMB OUT TO FL 240 BEFORE WE RETURNED, NOT PRESENT ON THE DESCEND ON LANDING. NO EICAS MSGS ASSOCIATED, NO FLASHING RED MASTER WARNING. NO OVERWEIGHT LANDING. R & R AWU IAW AMM 31-51-01.Mar 31, 2016 · N662EH · Emb EMB145LR · Central WarningSDR SIMA20160331003Electronic Unit · failedAFTER TAKEOFF CLIMBING THROUGH 8,000 FT TAKEOFF CONFIG WARNING. TAKEOFF CONFIG TRIM & FLAPS STARTED REPEATING. RETURNED, LG WEIGHT 43,300. TRANSFERRED TO NRWC 662 02488. R & R LGEU IAW AMM 32-32-01. OPERATIONS CHECKED GOOD.Mar 31, 2016 · N662EH · Emb EMB145LR · Landing Gear Retraction/Extension SystemSDR SIMA20160331001Rod · defectiveMAIN CABIN DOOR WILL NOT OPEN. DEPLANED VIA SERVICE DOOR. R&R ROD CONNECTED TO CAM ASSEMBLY FOR PAX DOOR FLAP ASSEMBLY IAW AMM 52-18-02. OPERATIONS CHECKED GOOD.Mar 31, 2016 · N617AE · Emb EMB145LR · Service DoorsSDR RAIA201603300001Bulb · inoperativeSERVICE DOOR EXTERIOR FLOOD LIGHT NR 2 INOPERATIVE. R & R SERVICE DOOR EXTERIOR FLOOD LIGHT BULB. OPS CHECKED GOOD.Mar 30, 2016 · N615AE · Emb EMB145LR · Emergency LightingSDR SIMA20160330005Skin · crackedLEFT REAR FUSELAGE I SKIN CRACKS AFT OF FRAME 75, BETWEEN STRINGERS 1L & 2L. PERFORMED PERMANENT REPAIR OF LT REAR FUSELAGE I SKIN AFT OF FRAME 75, BETWEEN STRINGERS 1L & 2L IAW ERS-EM-53MR-2007.Mar 30, 2016 · N907AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160330004Outflow Valve · malfunctionedDURING CLIMB THROUGH 7800 FT CABIN WAS DESCENDING 3300, APPROX FPM. AMBER EICAS MSG PRESN AUTO FAIL. CAB ALT, CAB DELTA P 8.0 PSI. R & R ELECTRO PNEUMATIC OUTFLOW VLV IAW 21-31 03. OPERATIONS CHECKED GOOD IAW 21-31-03, REF NRWC 628-DFW-02555.Mar 30, 2016 · N628AE · Emb EMB145LR · Pressure Regulator/Outflow ValveSDR SIMA20160330002Hinge · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPEN & CLOSE. LUBED MAIN CABIN DOOR FLAP HINGE. OPERATIONAL CHECKED GOOD IAW AMM 52-10-00.Mar 30, 2016 · N654AE · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20160329001Flashlight · inoperativeFIRST OFFICERS, CAPTAINS & FLIGHT ATTENDANT ALL SMELL ELEC BURNT SMELL EMANATING FROM FWD CLOSET. FOUND FLIGHT ATTENDANT FLASHLIGHT BURNED OUT. REPLACED FLIGHT ATTENDANT FLASHLIGHT IAW ACFT MX PRACTICES.Mar 29, 2016 · N668HH · Emb EMB145LR · Emergency EquipmentSDR ASOA20160328030HSAcm · inoperativeSUP: MAINTENANCE R & R THE NR 2 ACM, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, REMOVED THE MEK, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Mar 28, 2016 · N678AE · Emb EMB145LR · Cabin Cooling SystemSDR ASOA20160328030HA/C Pack · smokeTHE CREW REPORTED THAT SMOKE COMES OUT WHEN NR 2 PACK WAS TURNED ON. MAINTENANCE PLACED THE NR 2 PACK ON MEL 21-51-00-3, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Mar 28, 2016 · N678AE · Emb EMB145LR · Cabin Cooling SystemSDR ASOA20160328029HWarning Light · false activationTHE CREW REPORTED AN ENGINE 1 FIRE INDICATION IN FLIGHT. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE ACFT, OPERATIONALLY TESTED THE ENGINE 1 FIRE DETECTION SYS WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Mar 28, 2016 · N13995 · Emb EMB145LR · Fire DetectionSDR SIMA20160328002Unknown · odorSTRONG SOLVENT SMELL ON FLIGHT DECK. SOLVENT ODOR INCREASED SUBSTANTIALLY WHEN ACFT CONFIGURED FOR GATE DEPARTURE. CLEANED COCKPIT PEDESTAL AREA, VENTED COCKPIT BY OPENED SIDE WINDOW FOR A COUPLE OF MINUTES. PERFORMED OPERATIONAL CHECK OF RECIRCULATING SYS Mar 28, 2016 · N658AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20160327001Flashlight · inoperativeCAPTAINS FLASHLIGHT INOPERATIVE. FLIGHT CREW PLACARDED CAPTAINS FLASHLIGHT INOPERATIVE, MEL 25-53. INSTALLED FLASHLIGHT IAW EMB 145 AMM 33-50-16. FLASHLIGHT OCK GOOD. MEL ITEM RESTORED.Mar 27, 2016 · N683AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20160327002Controller · failedAT GATE ON APU GEN & PACK 2 NOTICED BURNING SMELL IN FLIGHT DECK & FOUND PRESS SPIKE & CONTROLLER DISPLAYED WENT BLANK, NO DISPLAY. ALSO NOTICED CB F8 POPPED. OPENED DV WINDOWS TO RELIEVE CABIN PRESS. REMOVED DIGITAL CONTROLLER & FOUND TO SMELL BURNT DIS-COMar 27, 2016 · N661JA · Emb EMB145LR · Cabin Pressure ControllerSDR ASOA20160326027Light · inoperativeDURING CREW INSPECTION AN EMERGENCY LIGHT WAS FOUND TO BE DIMLY LIT. MAINTENANCE R & R THE AFFECTED EMERGENCY LIGHT, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Mar 26, 2016 · N21537 · Emb EMB145LR · Emergency LightingSDR SIMA20160326002Sign · looseEMERGENCY EXIT SIGN ON LT CEILING LOOSE. SECURED EMER EXIT SIGN ON LT CEILING AS REQUIRED.Mar 26, 2016 · N689EC · Emb EMB145LR · Emergency LightingSDR SIMA20160325005Yoke · crackedLEFT FWD PYLON LOWER YOKE CRACKED. REMOVED & INSTALLED SERVICEABLE YOKE IAW EO EM-54MR-386. FOUND DURING INSPECTION WC 54-200-00.Mar 25, 2016 · N907AE · Emb EMB145LR · Nacelle/Pylon, Main Frame
Back to Embraer EMB-145LR