Embraer EMB-145LR

Service difficulty reports · 36,797

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SIMA20160108004Light · inoperativeGALLEY CEILING PANEL EMER LAMP INOPERATIVE. R & R GALLEY CEILING PANEL EMER LIGHT LAMP IAW AMM 33-26-05-000-802-A & 33-26-05-400-802-A.Jan 8, 2016 · N693AE · Emb EMB145LR · Emergency LightingSDR SIMA20160108003Light · inoperativeSERVICE DOOR EMER LIGHT INOPERATIVE. R & R SERVICE DOOR EMER LIGHT LAMP IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.Jan 8, 2016 · N654AE · Emb EMB145LR · Emergency LightingSDR ASOA201601070004Battery · dischargedDURING ROUTINE MAINTENANCE THE NR 4 EMERGENCY LIGHT BATTERY WOULD NOT TAKE A CHARGE. MAINTENANCE REPLACED THE NR 4 EMERGENCY LIGHT BATTERY. OPS CHECKS WERE GOOD.Jan 7, 2016 · N13538 · Emb EMB145LR · Emergency LightingSDR ASOA201601070003Battery Pack · inoperativeDURING ROUTINE MAINTENANCE, THE LT AND RT OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. MAINTENANCE REPLACED THE NR 4 EMERGENCY LIGHT BATTERY. OPS CHECKS WERE GOOD.Jan 7, 2016 · N11535 · Emb EMB145LR · Emergency LightingSDR SIMA20160107003Flap System · malfunctionedFLAP FAIL MSG ON EICAS, OCCURRED WHEN SELECTED FLAPS 9. IMMEDIATE MSG ON EICAS, FLAPS REMAINED AT 0. COMPLIED WITH FIM TASK 27-51-00-810-816A. CONSIDERED TO BE TRANSITORY CONDITION OF THE INBD & OTBD FLAP CONTROL SYS. PERFORMED OPERATIONAL CHECK OF THE FLAJan 7, 2016 · N659AE · Emb EMB145LR · Trailing Edge Flap Control SystemSDR SIMA20160107001Battery · dischargedEXTERIOR OVERWING EMER LIGHTS ON LT & RT WING INOPERATIVE. R & R BATTERY & CHARGER HOLDER ASSEMBLY IAW AMM 33-50-04. OPERATIONS CHECKED GOOD. BATTERY CHARGER PN 11-0049 & SN 19000.Jan 7, 2016 · N640AE · Emb EMB145LR · Emergency LightingSDR SIMA20160107002Inverter · inoperativeFOUND FLOOR STRIPS NR 2 AT NR 3 NOT WORKING. R & R NR 3 INVERTER IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.Jan 7, 2016 · N600BP · Emb EMB145LR · Emergency LightingSDR ASOA2016010700003Frame Splice · corrodedDURING C-CHECK, RIVETS AT CIRCUMFERENTIAL SPLICE SHOW SIGNS OF CORROSION FRAME 13. INSTALLED FILLER AND 2 DOUBLERS AT FRAME 13 SPLICE IAW SRM 53-00-02. ACFT APPROVED FOR RETURN TO SERVICE.Jan 7, 2016 · N12922 · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20160106007Light · crackedLEFT NR 1 EMER LIGHT STRIP CRACKED. R & R LT NR 1 EMER LIGHT STRIP IAW AMM 33-50-12.Jan 6, 2016 · N643AE · Emb EMB145LR · Emergency LightingSDR SIMA20160106009Light · crackedRIGHT NR 1 EMER LIGHT STRIP CRACKED. R & R RT NR 1 EMER LIGHT STRIP IAW AMM 33-50-12.Jan 6, 2016 · N643AE · Emb EMB145LR · Emergency LightingSDR SIMA20160106008Splice · miswiredGALLEY CEILING & COCKPIT STEP EMER EXIT LIGHTS WILL NOT ILLUMINATE. RECONNECTED WIRE SPLICES SP9009 & SP9010 ON PANEL 231AF CORRECTLY IAW WM 33-50-50, AMM 53-01-02 & SWPM 20-21-00. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.Jan 6, 2016 · N643AE · Emb EMB145LR · Light System WiringSDR SIMA20160106006Spar Cap · crackedTRANSFERRED FROM NRTC E488766, RT WING SPAR I LOWER CAP CRACKED AT RIB 9. COMPLIED WITH ERS-EM-57MR-575, RT SPAR I LOWER CAP CRACKED AT RIB 9.Jan 6, 2016 · N643AE · Emb EMB145LR · Wing SparSDR SIMA20160106005Wire · brokenEMERGENCY LIGHT ON CEILING PANEL 253CLC HAS A BROKEN WIRE. REPAIRED 2 CUT WIRES IAW SWPM 20-21-00. FOR OPERATIONS CHECK SEE BOW 208622.Jan 6, 2016 · N632AE · Emb EMB145LR · Light System WiringSDR SIMA20160106004Skin · crackedRIGHT AFT FUSELAGE FRAME 75, BELOW STRINGER 2 SKIN CRACKED AT FASTENER MARKED, SETTINGS 400KHZ 135 V-65.0 H-75.0 FILTER LO 100. CRACKED FUSELAGE SKIN AT FRAME 75, STRINGER 2R AREA WILL BE CUT OUT & REPAIRED WITH FILLER & DOUBLER, SEE NRTC E487295 FOR ACCOMPLIJan 6, 2016 · N632AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20160106003Wire · brokenPROXIMITY LIGHT 2 EACH WITH ARROWS, 1 EACH OVERWING EXIT & 1 EACH WITHOUT ARROWS HAVE BROKEN WIRES. R & R PROXIMITY LIGHTS IAW AMM 33-50-12. SEE NRTC BOW 208622 FOR FINAL INSTALL & OPERATIONS CHECKS.Jan 6, 2016 · N632AE · Emb EMB145LR · Light System WiringSDR SIMA20160106002Wire · brokenEMERGENCY EXIT LIGHT ON CEILING PANEL 233BLC HAS A BROKEN WIRE. REPAIRED CUT WIRE IAW SWPM 20-21-00. FOR OPERATIONS CHECK SEE BOW 208622.Jan 6, 2016 · N632AE · Emb EMB145LR · Light System WiringSDR SIMA20160106001Flashlight · inoperativeFIRST OFFICERS FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT IAW AMM 25-61-02. OPERATIONS CHECKED GOOD.Jan 6, 2016 · N941LT · Emb EMB145LR · Emergency EquipmentSDR SIMA20160105004Pump · unknownTAKEOFF 1, AFTER THRUST WAS SET, RECEIVED AN E1 FUEL LOW PRESSURE EICAS MSG, WITH ASSOCIATED RELAYS CLICKING CYCLING THE FUEL PUMPS. NR 1 ENG WAS ON PUMP C. ABORT BELOW 80 KTS HIGH SPEED. E1 FUEL LOW PRESS WITH PUMP 1C SELECTED. 1C FUEL PUMP & LOW PRESS WAJan 5, 2016 · N654AE · Emb EMB145LR · Engine Fuel PumpSDR SIMA20160105003Holder · crackedPILOTS FLASHLIGHT BASE CRACKED. R & R PILOTS FLASHLIGHT ASSEMBLY IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.Jan 5, 2016 · N663AR · Emb EMB145LR · Emergency EquipmentSDR SIMA20160105001Light · inoperativeRIGHT WING, EXT EMER LIGHT INOPERATIVE. R & R BULB RT WING LIGHT EMER IAW AMM 33-50-10. NO DEFECT NOTED.Jan 5, 2016 · N638AE · Emb EMB145LR · Emergency LightingSDR SIMA20160104001Unknown · leakingSMALL FUEL LEAK IN BELLY AREA. COMPLIED WITH LEAK CHECK BOTH WING TANKS & REFUEL SYS IAW AMM 28-11-00. NO LEAKAGE OR SEEPAGE NOTED AT THIS TIME. COULD NOT DUPLICATE.Jan 4, 2016 · N645AE · Emb EMB145LR · Fuel StorageSDR ASOA201601040012Charger · inoperativeDURING ROUTINE MAINTENANCE THE LT WING EXTERNAL EMERGENCY LIGHT AND 1 AISLE PATH EMERGENCY LIGHT WAS FOUND INOPERATIVE. MAINTENANCE REPLACED THE NR 1 EMERGENCY LIGHT BATTERY CHARGER ASSY. OPS CHECKS WERE GOOD.Jan 4, 2016 · N18557 · Emb EMB145LR · Emergency LightingSDR ASOA201601040011Beam · corrodedDURING C-CHECK, BAGGAGE DOOR CUTOUT LOWER BEAM HAS CORROSION, FR 65-68. R & R BAGGAGE DOOR CUTOUT LOWER BEAM IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.Jan 4, 2016 · N12922 · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20160102002Flashlight · inoperativeFIRST OFFICERS FLASHLIGHT INOPERATIVE. FLIGHT CREW PLACARDED FIRST OFFICERS FLASHLIGHT MEL 2553. R & R FIRST OFFICERS FLASHLIGHT. OPERATIONS CHECKED GOOD. MEL ITEM RESTORED.Jan 2, 2016 · N942LL · Emb EMB145LR · Emergency EquipmentSDR SIMA20160102001Flashlight · inoperativeCAPTAINS FLASHLIGHT INOPERATIVE. R & R CAPTAINS FLASHLIGHT IAW AMM 33-50-16-000-801 & 33-50-16-400-801. OPERATIONS CHECKED GOOD.Jan 2, 2016 · N932AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20160101001Smoke Detector · faultyLAVATORY SMOKE INDICATOR, FLIGHT ATTENDANT CHECKED WITH NO SMOKE. INDICATOR LAVATORY SMOKE PERSISTED & WE DIVERTED. R & R LAVATORY SMOKE DETECTOR PANEL IAW AMM 26-14-02.Jan 1, 2016 · N617AE · Emb EMB145LR · Smoke DetectionSDR SIMA20151231005Spar Cap · crackedLEFT WING SPAR I LOWER SPAR CAP CRACKED AT RIB 9. REPAIRED LT WING SPAR I LOWER CAP IAW ERS-EM-57MR-567.Dec 31, 2015 · N634AE · Emb EMB145LR · Wing SparSDR SIMA20151231004Fitting · chafedINBOARD LUG ON THE LT AILERON DAMPENER FITTING IS CHAFED ON THE INBD SIDE. DAMPENER FITTING REPLACED IAW EO EM-27MR-112.Dec 31, 2015 · N690AE · Emb EMB145LR · AileronsSDR SIMA20151231003Rib · bentRUDDER 1 HAS 2 BENT RIBS. 1 NEAR THE UPPER CTR HINGE POINT & 1 BY THE LOWER CTR HINGE POINT. INSTALLED RIB IAW SRM 51-40-02.Dec 31, 2015 · N690AE · Emb EMB145LR · Rudder, Spar/RibSDR SIMA20151231002Holder · defectiveCAPTAINS SIDE COCKPIT FLASHLIGHT HOLDER DOES NOT RETAIN THE FLASHLIGHT. R & R FLASHLIGHT HOLDER IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.Dec 31, 2015 · N682AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151231001Outflow Valve · failedCLIMBING THROUGH 350 TO 360 WE HAD THE PRESSURIZATION CLIMB TO 11300' FEET. DEFERRED AUTO & MANUAL PRESSURIZATIONS. M PROCEDURES COMPLIED WITH. PERFORMED TROUBLESHOOTING IAW FIM 21-31-00, DID NOT FIX. SEE KVA FOR UPDATE. MEL 21-18 REMAINS OPEN. M PROCEDUDec 31, 2015 · N648AE · Emb EMB145LR · Pressure Regulator/Outflow ValveSDR SIMA20151230003Flashlight · inoperativeCAPTAINS FLASHLIGHT STOPPED WORKING ON POSTFLIGHT. R & R CAPTAINS FLASHLIGHT IAW AMM 33-50-16-4.Dec 30, 2015 · N695AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151230002Light · inoperativeRIGHT AFT OVERWING EMER LIGHT INOPERATIVE. RELAMPED RT AFT OVERWING EMER LIGHT IAW AMM 33-50-07. TESTED SATISFACTORY IAW WC 33-700-17.Dec 30, 2015 · N674RJ · Emb EMB145LR · Emergency LightingSDR SIMA20151229005Light · damagedLEFT 1 & 5 PROXIMITY LIGHT STRIP EXTRUSIONS DAMAGED. R & R LT 1 & 5 PROXIMITY LIGHT STRIP EXTRUSIONS IAW AMM 33-50-12. SEE BOW 208816 FOR OPERATIONAL CHECK.Dec 29, 2015 · N634AE · Emb EMB145LR · Emergency LightingSDR SIMA20151229006Support · crackedLEFT FLOORBEAM OTBD SUPPORT CRACKED, BETWEEN FRAME 47 & 48. R & R LT FLOORBEAM OTBD SUPPORT, TWO PIECES, BETWEEN FRAME 47 & 48, OVER WING BOX AREA, IAW SRM 53-23-02 & SRM 51-40-02.Dec 29, 2015 · N634AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20151229007Support · crackedLEFT FLOORBEAM INBD SUPPORT AFT END, CRACKED AT FRAME 50. R & R LT FLOORBEAM INBD SUPPORT AT FRAME 50, OVER WING BOX AREA, WITH NEW SERVICEABLE SUPPORTS, TWO PIECES, IAW SRM 53-23-02 & SRM 51-40-02.Dec 29, 2015 · N634AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20151229009Support · corrodedCENTER FLOORBEAM INBD SUPPORT CORRODED ON AFT END AT FRAME 5. R & R CTR FLOORBEAM INBD SUPPORT AT FRAME 50 IAW SRM 51-40-02 & 51-20-03.Dec 29, 2015 · N634AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20151229008Skin · crackedINVESTIGATE POSSIBLE SKIN CRACK AROUND FASTENER AT FRAME 78, BETWEEN STRINGER 06R - 07R. FOUND TO BE CRACKED, INSTALLED SERVICEABLE SKIN BUSHING TO FRAME 78, BETWEEN STRINGER 06R & 07R IAW ERS-EM-5300-1883.Dec 29, 2015 · N634AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151229003Holder · brokenCAPTAINS FLASHLIGHT HOLDER BROKEN. R & R CAPTAINS FLASHLIGHT HOLDER IAW AMM 33-50-16-000-801-A & 33-50-16-400-801-A. OPERATIONS CHECKED GOOD.Dec 29, 2015 · N660CL · Emb EMB145LR · Emergency EquipmentSDR SIMA20151229001Door · lack of lubeFLIGHT ATTENDANT REPORTS MAIN CABIN DOOR DIFFICULT TO OPEN. MAIN CABIN DOOR LUBRICATED & OPERATIONS CHECKED FOR OPENING & CLOSING, GOOD IAW AMM52-18-06.Dec 29, 2015 · N908AE · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20151228005Brake Assy · failedNUMBER 2 BRAKE FAILED CARBON INSPECTION. R & R NR 2 BRAKE IAW WC 32-600-14.Dec 28, 2015 · N647AE · Emb EMB145LR · BrakeSDR SIMA20151228004Brake Assy · failedBRAKE CARBON INSPECTION DUE ON BRAKE ASSEMBLY NR 4. COMPLIED WITH BRAKE ASSEMBLY NR 4 CARBON INSPECTION & BRAKE FAILED. BRAKE ASSEMBLY NR 4 NEEDS REPLACEMENT. SEE ITEM NR 2 LOG PAGE 3962950 FOR DISCREPANCY. R & R NR 4 MLG BRAKE ASSEMBLY IAW WC 32-600-14.Dec 28, 2015 · N645AE · Emb EMB145LR · BrakeSDR SIMA20151228002Unknown · odorWHILE STARTING AT THE GATE, APU FIRE WARNING ON EICAS MSG WITH A BURNING SMELL. DEFERRED APU M PROCEDURES COMPLIED WITH IAW 49-1. PERFORMED INSPECTION OF APU FIRE WARNING IAW TASK 05-50-11-200-801-A. PERFORMED SEVERAL START CYCLES OF APU IAW 49-10-00-910-80Dec 28, 2015 · N647AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20151228003Sign · inoperativeFORWARD RT BULKHEAD PANEL EMER LIGHT FOUND NOT WORKING. R & R FWD RT BULKHEAD EMER EXIT SIGN IAW AMM 33-50-13, DID NOT FIX PROBLEM.Dec 28, 2015 · N645AE · Emb EMB145LR · Emergency LightingSDR RAIA201512270001Seal · wornBLEED 2 LEAK EICAS MSG DURING CLIMB, RETURNED TO BLOCK. MAINTENANCE REPLACED BLEED SEALS AT POSITION 14 ON NR 2 BLEED IN FWD CARGO BULKHEAD, OPS CHECK GOOD.Dec 27, 2015 · N606AE · Emb EMB145LR · Pneumatic Distribution SystemSDR SIMA20151227006Pitot Line · contaminatedGOT IAS COMPARATOR ALERT ON BOTH PFD'S DURING DESCENT FROM FL 310. FIRST OFFICERS IAS WAS EQUAL TO THE STBY ISIS IAS. DURING DESCENT THE CAPTAINS IAS WAS INDICATING SLOWER AT AN INCREASING DIFFERENCE TO 100 KNTS. SELECTED ADC ON CAPTAINS REVERSIONARY PANEL WDec 27, 2015 · N670AE · Emb EMB145LR · Pitot/Static SystemSDR SIMA20151227005Unknown · odorELECTRIC BURN SMELL IN COCKPIT & CABIN NO ABNORMAL INDICATIONS IN COCKPIT SYSTEMS. PERFORMED OPERATIONS CHECK WITH PACK RUNNING IAW 21-00-00. WITH ENG RUNNING IAW RR MM 72-00-00, LIGHTING SYS & NO ELECTRICAL SMELL NOTED AT THIS TIME.Dec 27, 2015 · N669MB · Emb EMB145LR · Air Distribution SystemSDR SIMA20151227004Light · inoperativeRIGHT CTR FAIRING EMER LIGHT INOPERATIVE. R & R RT CTR FAIRING EMER LAMP IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.Dec 27, 2015 · N908AE · Emb EMB145LR · Emergency LightingSDR RAIA201512260002Trim Switch · inoperativePITCH TRIM MAIN INOPERATIVE, FOLLOWED BY BACK UP PITCH TRIM INOPERATIVE, FOLLOWED QRH. BACK UP PITCH TRIM CAME BACK, RETURNED TO BLOCK. MAINTENANCE INSPECTED AND REPLACED THE PITCH TRIM SWITCH AND RERACKED THE HSCU, OPS CHECKED GOOD.Dec 26, 2015 · N810HK · Emb EMB145LR · Stabilizer Control SystemSDR RAIA201512260001Light · inoperativeCEILING EMERGENCY EXIT LIGHT AT ROW 23 IS INOPERATIVE. MAINTENANCE REPLACED EMERGENCY EXIT LIGHT, OPS CHECK GOOD.Dec 26, 2015 · N842HK · Emb EMB145LR · Emergency Lighting
Back to Embraer EMB-145LR