Embraer EMB-145LR

Service difficulty reports · 36,797

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SIMA20151030006Skin · damagedLIGHTNING STRIKE BETWEEN FRAME 62 - 63, BETWEEN STRINGER 21L & 21R. REMOVED DAMAGE BY DRILLING NR 21 HOLE AT THE STRIKE. INSTALLED BUTTON HEAD RIVET & WASHER IN DRILLED LOCATION IAW SRM 53-00-01 & 51-20-03.Oct 30, 2015 · N620AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151030005Frame · gougedFRAME 65 GOUGED UPPER CTR AREA. REPAIRED FRAME 65 GOUGE IAW ERS-EM-53MR-1731.Oct 30, 2015 · N620AE · Emb EMB145LR · Fuselage Main, FrameSDR ASOA20151030063Skin · dentedGROUND PERSONAL REPORTED DENT DAMAGE AROUND RT REAR AREA OF ACFT FUSELAGE BETWEEN STRINGERS 18R & 19R AND FRAMES 62 & 63A. MAINTENANCE INSPECTED AND PERFORMED REPAIR, FILLER AND DOUBLER OF DENT DAMAGE IAW ETD 2015-145-101284 AND SRM 51-40-02. DAMAGE MEASUREMOct 30, 2015 · N15983 · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151030001Unknown · odorSTRONG SMELL OF ELEC FUMES IN COCKPIT. OPERATED PACKS IAW GHC, OPERATED COCKPIT LIGHTING SYS IAW MM CH 33. OPERATIONS CHECKED OF W/S ONE & TWO HEAR GOOD IAW MM 30-42-01. PERFORMED GENERAL OLFACTORY INSPECTION OF COCKPIT, NO ABNORMAL SMELL OF ANY KIND NOTED.Oct 30, 2015 · N655AE · Emb EMB145LR · Air Distribution SystemSDR SIMA20151030004Flashlight · inoperativeAFT CABIN FLASHLIGHT IS INOPERATIVE. R & R AFT CABIN FLASHLIGHT IAW AMM 33-50-00.Oct 30, 2015 · N635AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151029011Structure · crackedFLOOR EXTRUSION AT 231FF IS CRACKED. R & R FLOOR EXTRUSION AT 231FF IAW AMM 33-50-12.Oct 29, 2015 · N694AE · Emb EMB145LR · Emergency LightingSDR SIMA20151029012Skin · crackedRIGHT AFT FUSELAGE SKIN CRACKED AT FASTENER AREA FRAME 75, BELOW STRINGER 2R. REPAIR SATISFACTORILY ACCOMPLISHED IAW ERS-EM-53MR-1791.Oct 29, 2015 · N694AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151029013Skin · crackedLEFT AFT FUSELAGE SKIN CRACKED AT FASTENER AREA FRAME 75, BELOW STRINGER 2L. LEFT AFT FUSELAGE SKIN CRACKED FRAME 75 SATISFACTORILY ACCOMPLISHED IAW ERS-EM-53MR-1790. SEE TURNOVER FOR DETAILS.Oct 29, 2015 · N694AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151029010Check Valve · failedEMERGENCY PARKING BRAKE SYS RETURN LINE CHECK VLV FAILED OPERATIONAL CHECK. R & R EMER PARKING BRAKE SYS RETURN LINE CHECK VLV IAW AMM 32-44-08. LEAK CHECKED GOOD. TQ WR EASI 8301.Oct 29, 2015 · N694AE · Emb EMB145LR · Master Cylinder/Brake ValveSDR SIMA20151029008Flashlight · intermittentAFT CABIN FLASHLIGHT INTERMITTENT. R & R CABIN FLASHLIGHT IAW 145-EEL-08-12.Oct 29, 2015 · N694AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20151029009Support · crackedRIGHT BEAM INBD SUPPORT IS CRACKED, BETWEEN FRAME 47 & 48. REMOVED CRACKED RT BEAM INBD SUPPORT, BETWEEN FRAME 46 - 50. INSTALLED SERVICEABLE RT BEAM INBD SUPPORT, BETWEEN 46 - 50 IAW SRM 51-40-02.Oct 29, 2015 · N694AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20151029005Light · inoperativeMAIN CABIN DOOR EMER LIGHT INOPERATIVE. R & R LAMP IN MAIN CABIN DOOR EMER LIGHT FIXTURE IAW AMM 33-50-06-000-801 & 33-50-06-400-801. OPERATIONS CHECKED GOOD AT THIS TIME.Oct 29, 2015 · N907AE · Emb EMB145LR · Emergency LightingSDR SIMA20151029007Module · failedBACKLIGHT AROUND EMER LIGHT SWITCH & BRIGHTNESS KNOB INOPERATIVE. R & R EMER LIGHT OVERHEAD MODULE IAW AMM 33-12-00. OPERATIONS CHECK FOUND OK.Oct 29, 2015 · N908AE · Emb EMB145LR · Flight Compartment LightingSDR SIMA20151029002Light · inoperativeBLEED 2 PUSH BUTTON LIGHTS INOPERATIVE. R & R BLEED 2 PUSH BUTTON LIGHT LAMP IAW AMM 20-13-04-000-801-A & 20-13-04-400-801-A. OPERATIONS CHECKED GOOD.Oct 29, 2015 · N690AE · Emb EMB145LR · Pneumatic Indicating SystemSDR SIMA20151029006Light · inoperativeLEFT FWD EXTERIOR EMER LIGHT INOPERATIVE. TRANSFERRED TO AML PAGE 3909957 ITEM 1. DEFERRED IAW MEL 33-29. R & R EXTERNAL LT FWD LIGHT ASSEMBLY IAW MM 33-50-10. OPERATIONS TESTED GOOD IAW MM 38-50-00. MEL RESTORED & PLACARD REMOVED.Oct 29, 2015 · N647AE · Emb EMB145LR · Emergency LightingSDR UHLA201510290776Handle · unsecureTHE MAIN ENTRY DOOR HANDLE WAS FOUND NOT SECURE. MAINTENANCE SECURED THE HANDLE IAW AMM 52-11-06 AND ALL OPS CHECKS WERE GOOD.Oct 29, 2015 · N280SK · Emb EMB145LR · Passenger/Crew DoorsSDR ASOA20151028055Light · arcedCREW REPORTED AN ACRID BURNING ODOR OBSERVED AROUND ROW 10A. MAINTENANCE R & R PASSENGER CABIN LIGHT ASSY AT SEAT 10A WITH OPS CHECK GOOD. ACFT APPROVED FOR RETURN TO SERVICE.Oct 28, 2015 · N21537 · Emb EMB145LR · Passenger Compartment LightingSDR SIMA20151028003Warning System · false activationDURING CONFIGURATION FOR LANDING FLAP FAIL MSG DISPLAYED UPON SELECTION OF FLAPS 9. FLAPS FAILED AT 0. RAN AOM 1 PROCEDURE LANDED FLAPS UP, TOUCHDOWN NORMAL. VREF 158 KTS USED MAX REVERSE. TROUBLE SHOT IAW FIM 27-51-00-810-817. CHECKED SCREWS, NO DEFECTS Oct 28, 2015 · N647AE · Emb EMB145LR · Trailing Flap Position Indicating SystemSDR SIMA20151028004Warning System · activatedDURING CLIMB, IN ICING CONDITIONS, EICAS DISPLAYED WING ANTI-ICE FAIL & WING PB OPEN INSCRIPTION DID NOT ILLUMINATE. IAW AOM 1 PROCEDURE SELECTED OVERRIDE TO ALL VLV SEEMED TO OPEN BUT BROKE OUT ON TOP & EXITED ICING CONDITIONS. KNOWING WE WOULD HAVE TO DESCOct 28, 2015 · N647AE · Emb EMB145LR · Airfoil Anti/De-ice SystemSDR SIMA20151028001Inverter · inoperativeAFT GALLEY EMER EXIT LIGHT INOPERATIVE. R & R NR 3 INVERTER. AFT GALLEY EMER EXIT LIGHT. OPERATIONS CHECKED GOOD IAW AMM 33-50-11.Oct 28, 2015 · N645AE · Emb EMB145LR · Emergency LightingSDR ASOA20151027084Battery Pack · dischargedDURING MAINTENANCE INSPECTION THE PROXIMITY LIGHTS AND OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE R & R THE NR 4 EMERGENCY LIGHT BATTERY, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 27, 2015 · N11551 · Emb EMB145LR · Emergency LightingSDR SIMA20151026004Wire · brokenCEILING PANEL 253 CLC HAS BROKEN WIRE, FOUND ON OPEN UP. REPAIRED EMER EXIT LIGHT WIRE ON PANEL 253CLC IAW SWPM 20-21-00.Oct 26, 2015 · N620AE · Emb EMB145LR · Light System WiringSDR RAIA2015260003Light · inoperativeSERVICE DOOR EMERGENCY LIGHT NR 2 INOPERATIVE. R & R SEVICE DOOR EMERGENCY FLOOD LIGHT NR 2. OPS CHECK GOOD.Oct 26, 2015 · N615AE · Emb EMB145LR · Emergency LightingSDR RAIA201510260002Power Supply · inoperativePAX DOOR EMERGENCY FLOOD LIGHT NR 1 INOPERATIVE. R & R EMERGENCY BATTERY POWER SUPPLY. OPS CHECK GOOD.Oct 26, 2015 · N615AE · Emb EMB145LR · Emergency LightingSDR SIMA20151026003Skin · chafedRIGHT FUSELAGE IS CHAFED INSIDE 424DB. REPAIRED RT FUSELAGE CHAFED INSIDE 424DB IAW ERS-EM-53MR-1729.Oct 26, 2015 · N683AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151026002B-Nut · looseENGINE 1 ANTI-ICE FAIL ON CLIMB AT 12 - 14,000 FT. RAN CHECKLIST E1 INLET AIR OPEN. ASSOCIATED MSGS, NO ICE ANTI-ICE ON, ENG ANTI-ICE OVERPRESS. TROUBLE SHOT IAW FIM 30-21-00-810-803-A, FOUND B NUT ON LT ENG ANTI-ICE DUCT TO BE LOOSE. TIGHTENED B NUT IAW AOct 26, 2015 · N682AE · Emb EMB145LR · Air Intake Anti/De-Ice SystemSDR ASOA20151030188Seal · misinstalledDURING CRUISE THE SERVICE DOOR SEAL WAS FOUND TO HAVE GAPS WHERE LIGHT WAS VISIBLE AND WAS MAKING A LOUD SQUEALING SOUND. THE AIRCREW DIVERTED AND LANDED SAFELY WITHOUT INCIDENT. NO EMERGENCY WAS DECLARED. UPON INSPECTION, MAINTENANCE FOUND THE SEAL TO BE Oct 25, 2015 · N633AE · Emb EMB145LR · Service DoorsSDR ASOA20151025061Smoke Detector · no testTHE CREW REPORTED F/A COULD NOT TEST SMOKE DETECTOR. MAINTENANCE INSPECTED AND REPLACED THE SMOKE DETECTOR SENSOR. OPS CHECKS WERE GOOD.Oct 25, 2015 · N12921 · Emb EMB145LR · Smoke DetectionSDR SIMA20151025001Skin · damagedHAIL DAMAGE EVENT. REPLACE LT STAB UPPER SKIN. ACFT WAS REMOVED FROM SERVICE FOR SKIN REPLACEMENT & WILL BE RETURNED TO SERVICE AFTER SKIN REPLACEMENT. R & R LT STAB UPPER SKIN IAW SRM 51-40-02, 51-20-03, 51-40-06, 51-40-03, 51-20-01, 55-10-01SI, ETN-EM-55-Oct 25, 2015 · N674RJ · Emb EMB145LR · Horizontal Stabilizer, Plate/SkinSDR SIMA20151025002Skin · damagedHAIL DAMAGE EVENT. REPLACE RT STAB UPPER SKIN. ACFT WAS REMOVED FROM SERVICE FOR SKIN REPLACEMENT & WILL BE RETURNED TO SERVICE AFTER SKIN REPLACEMENT. R & R RT STAB UPPER SKIN IAW SRM 51-40-02, 51-20-03, 51-40-06, 51-40-03, 51-20-01, 55-10-01SI, ETN-EM-55-Oct 25, 2015 · N674RJ · Emb EMB145LR · Horizontal Stabilizer, Plate/SkinSDR SIMA20151025003Valve · failedWHILE CLIMBING THOUGH 190 - 200, OAT 7*C TAT BLEED 1 OVER TEMP MSG, WITH ICE PROTECTION ON, IN ICING CONDITIONS. R & R FAN AIR VLV IAW AMM 36-11-03 & 36-00-00. OPERATIONS CHECKED GOOD.Oct 25, 2015 · N628AE · Emb EMB145LR · Pneumatic Distribution SystemSDR SIMA20151024004Skin · damagedLIGHTNING STRIKE, BETWEEN FRAME 71 - 72, STRINGER 21R, FOUND DURING LIGHTNING STRIKE INSPECTION. REMOVED DAMAGE BY DRILLING NR 10 HOLE AT THE STRIKE & INSTALLED BUTTON HEAD RIVET & WASHER IN DRILLED LOCATION IAW SRM 53-00-01 & 51-20-03.Oct 24, 2015 · N620AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151024003Flashlight · inoperativeFORWARD FLIGHT ATTENDANT FLASHLIGHT INOPERATIVE. R & R FWD FLIGHT ATTENDANT FLASHLIGHT IAW AMM 33-50-16.Oct 24, 2015 · N699AE · Emb EMB145LR · Emergency LightingSDR SIMA20151024001Fitting · damagedHAIL DAMAGE EVENT. DURING CTR I LT FUSELAGE SKIN REPLACEMENT, FOUND DAMAGED SHEAR CLIP ON FRAME 23, BETWEEN STRINGER 5L & 6L. ACFT WAS REMOVED FROM SERVICE FOR SKIN REPLACEMENT & WILL BE RETURNED TO SERVICE AFTER SKIN REPLACEMENT. FABRICATED SHEAR CLIP IAW Oct 24, 2015 · N674RJ · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201510240002Stop · inoperativeEMERGENCY EXIT ROW TRAY TABLE 18D STOPS INOPERATIVE. ADJUSTED TRAY TABLE STOP AT 18D. OPS CHECK GOOD.Oct 24, 2015 · N855HK · Emb EMB145LR · Passenger Compartment EquipmentSDR RAIA201510240001Terminal · dirtyAFT EMERGENCY EXIT SIGN AT 18A, LIGHT NR 23, IS INOPERATIVE. DISCONNECTED, CLEANED AND RECONNECTED TERMINALS AND PERFORMED OPS CHECK OF EMERGENCY LIGHTING SYSTEM. OPS CHECK GOOD.Oct 24, 2015 · N811HK · Emb EMB145LR · Light System WiringSDR UHLA201510230774Step · brokenTHE MAIN ENTRY DOOR STEPS WERE FOUND TO BE BROKEN. MAINTENANCE ADJUSTED THE SPRINGS ON THE MAIN ENTRY DOOR STEPS IAW AMM 52-10-01 AND ALL OPS CHECKS WERE GOOD. NO FURTHER DEFECTS HAVE BEEN NOTED.Oct 23, 2015 · N563RP · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20151023001Thermostat · failedWHILE CLIMBING THROUGH FLIGHT LEVEL 180 - 190, IN ICING CONDITIONS BLEED 1 OVER TEMP WARNING ON EICAS. COMPLIED WITH AOM EMER PROCEDURES. DEFERRED THE NR 1 BLEED SYS. M PROCEDURES COMPLIED WITH IAW 36-01. R & R FAN CONTROL THERMOSTAT IAW AMM 36-11-06. OPOct 23, 2015 · N628AE · Emb EMB145LR · Pneumatic Distribution SystemSDR ASOA20151022054Wire Harness · damagedPILOT REPORTED A FUNNY ODOR IN CABIN NEAR MCD. MAINTENANCE R & R CABIN CEILING LIGHT HARNESS AT SEAT 1A WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 22, 2015 · N16911 · Emb EMB145LR · Light System WiringSDR RAIA201510220001Socket · burnedBURNING ODOR IN CABIN. FOUND BURNED LIGHT SOCKET AT ROW 17 AND 18A. DEACTIVATED BULB AND REMOVED CONNECTOR.Oct 22, 2015 · N832HK · Emb EMB145LR · Passenger Compartment LightingSDR SIMA20151022006Light · inoperativeMAIN DOOR EMER LIGHT INOPERATIVE. R & R LAMP IN MAIN DOOR EMER LIGHT ASSEMBLY IAW AMM 33-50-06-000-801 & 33-50-06-400-801. OPERATIONS CHECKED GOOD AT THIS TIME.Oct 22, 2015 · N900AE · Emb EMB145LR · Emergency LightingSDR SIMA20151022004Frame · gougedFRAME 65 GOUGED AT TOP, AROUND NUTPLATE HOLE. REPAIRED FRAME 65 GOUGED AT TOP, AROUND NUTPLATE HOLE IAW ERS-EM-53MR-1711.Oct 22, 2015 · N683AE · Emb EMB145LR · Fuselage Main, FrameSDR UHLA201510210770Roller · bentTHE MAIN ENTRY DOOR ROLLER WAS FOUND BENT. MAINTENANCE R & R THE MAIN DOOR FRAME ROLLER SUPPORT ACTUATOR IAW AMM 53-21-02 AND ALL OPS CHECKS WERE GOOD. NO FURTHER DEFECTS HAVE BEEN NOTED.Oct 21, 2015 · N567RP · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20151021005Yoke · crackedLEFT PYLON LOWER FWD YOKE IS CRACKED. REPAIRED LT PYLON LOWER FWD YOKE IAW EO EM-54MR-386.Oct 21, 2015 · N683AE · Emb EMB145LR · Nacelle/Pylon, Attach FittingsSDR SIMA20151021004Skin · crackedFRAME 75 FUSELAGE SKIN CRACKED ABOVE STRINGER 2R, RT SIDE. PERFORMED PERMANENT REPAIR OF FRAME 75, FUSELAGE SKIN CRACK ABOVE STRINGER 2R, RT SIDE IAW ERS-EM-53MR-1726.Oct 21, 2015 · N630AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20151021002Uplock · failedAFTER TAKEOFF & GEAR RETRACT, HEARD A LOUD CONTINUOUS THUMPING UNDER ACFT & RT MAIN GEAR LIGHT CHANGING FROM GREEN TO AMBER. RETURNED TO FIELD FOR LANDING. TRANSFERRED TO NRWC 635-ABI-02482. R & R RT UPLOCK BOX IAW AMM 32-33-10. OPERATIONS & LEAK CHECKED GOct 21, 2015 · N635AE · Emb EMB145LR · Landing Gear Retraction/Extension SystemSDR SIMA20151021003Battery · dischargedALL EMER LIGHTS CONNECTED TO BATTERY NR 4, DO NOT COME ON. R & R BATTERY & CHARGER IAW WC 33-700-19. OPERATIONS CHECKED GOOD IAW WC 33-700-17.Oct 21, 2015 · N630AE · Emb EMB145LR · Emergency LightingSDR ASOA20151021083HFirewall · crackedDURING MAINTENANCE INSPECTION, A CRACK WAS FOUND IN THE APU FIREWALL AT APPROXIMATELY THE 2 O'CLOCK POSITION NEAR AN EXISTING DOUBLER. MAINTENANCE REMOVED THE EXISTING DOUBLER AND PERFORMED A COMBINATION REPAIR IAW SRM 53-32-13 AND THE ACFT WAS APPROVED FOR ROct 21, 2015 · N17984 · Emb EMB145LR · APU Cowling/ContainmentSDR SIMA20151021001Door Frame · corrodedLEFT EMER EXIT LOWER FRAME, CORRODED UNDER CIRCULAR TEFLON GUIDE. R & R NEW LT EMER EXIT LOWER FRAME IAW SRM 51-40-02.Oct 21, 2015 · N630AE · Emb EMB145LR · Emergency ExitsSDR SIMA20151020022Skin · damagedHAIL DAMAGE EVENT. R & R LT CTR FUSELAGE I UPPER SKIN IAW SRM 51-40-02, 53-21-01-SI, 51-20-01, 51-20-03, 51-40-06, ETN-EM-51-118, ETN-EM-53-262 & ERS EM-5300-1759.Oct 20, 2015 · N648AE · Emb EMB145LR · Fuselage Main, Plate/Skin
Back to Embraer EMB-145LR