Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20150714005Battery · unknownA3265 R & R EMER LIGHTING BATTERY ASSEMBLY & BATTERY CHARGER NR 1 IAW WC 33-700-19, WC 33-002 & SN109808.SDR SIMA20150714006Connector · damagedELECTRICAL CONNECTOR P8563 TO THE LT EXTERIOR OVERWING EMER LIGHT HAS A DAMAGED HEAT SHRINK BOOT. R & R HEAT SHRINK BOOT AT ELEC CONNECTOR P8563 TO THE LT EXTERIOR OVERWING EMER LIGHT IAW SWPM 20-50-00 STEP 17.SDR SIMA20150714007Battery · dischargedNUMBER 4 EMER BATTERY & CHARGER INOPERATIVE. R & R NR 4 EMER BATTERY & CHARGER IAW AMM 33-50-04. OPERATIONS CHECKED GOOD.SDR SIMA20150714004Yoke · crackedRIGHT ENG FWD YOKE CRACKED, LOWER FWD CORNER. R & R RT ENG FWD YOKE IAW EO-EM-54MR-386.SDR SIMA20150714008Battery · dischargedNUMBER 2 EMER BATTERY & CHARGER INOPERATIVE. R & R NR 2 EMER BATTERY & CHARGER IAW AMM 33-50-04. OPERATIONS CHECKED GOOD.SDR RAIA201507140002Power Supply · dischargedLEFT OVERWING EXTERIOR EMERGENCY FLOOD LIGHT NR 5 INOPERATIVE. MAINTENANCE REPLACED NR 4 POWER SUPPLY BATTERY, OPS CHECKED GOOD.SDR RAIA201507140001Power Supply · dischargedRIGHT OVERWING EXTERIOR EMERGENCY FLOOD LIGHT NR 6 INOPERATIVE. MAINTENANCE REPLACED NR 4 BATTERY POWER SUPPLY, OPS CHECKED GOOD.SDR SIMA20150714003Light · inoperativeLAST ROW CTR AISLE FLOOR EMER LIGHTS INOPERATIVE. R & R LAST ROW CTR AISLE FLOOR EMER LIGHT IAW AMM 33-50-12. OPERATIONS CHECKED NORMAL.SDR SIMA20150714002Flashlight · brokenAFT CABIN EMER FLASHLIGHT BASE BROKEN. R &R AFT CABIN EMER FLASHLIGHT CRADLE IAW AMM 33-50-16-000-801-A & 33-50-16-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20150714001Clamp · looseBLEED 1 LEAK AFTER ACCEL ALT IN CLIMB THRUST, MODE WARNING EXTINGUISHED 30 SECONDS AFTER BLEED 1 SELECTED OFF. FOUND CLAMP LEAKING IN LT PYLON, RETIGHTENED CLAMPS ON Y DUCT IN LT PYLON IAW AMM 36-11-09.SDR RAIA201507130001Light · inoperativePASSENGER DOOR EMERGENCY EXIT LIGHT NR 1 INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSY, OPS CHECKED GOOD.SDR RAIA201507130004Light · malfunctionedEMERGENCY EXIT LIGHT NR 20 INOPERATIVE. MAINTENANCE CYCLED POWER TO RESET SYSTEM, OPS CHECK GOOD.SDR RAIA201507130003Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT NR 8 INOPERATIVE. MAINTENANCE REPLACED THE LAMP, OPS CHECKED GOOD.SDR RAIA201507130002Light · malfunctionedEMERGENCY EXIT LIGHT NR 19 INOPERATIVE. MAINTENANCE CYCLED ACFT POWER TO RESET SYSTEM, OPS CHECK GOOD.SDR SIMA20150713002Control Unit · faultyCLIMBING THROUGH 7,000 FT, PITCH TRIM INDICATION HAD DASHES & POINTER DISAPPEARED. AFTER INDICATIONS RETURNED NORMALLY. THE AUTO PILOT DISCONNECTED APPROX 3 TIMES & THE PITCH TRIM DASHES REAPPEARED. OBSERVED FAULT CODE 274M0700. TROUBLE SHOT IAW FIM TASK 2SDR SIMA20150713001Flashlight · brokenFIRST OFFICERS FLASHLIGHT BROKEN. R & R FLASHLIGHT IAW SMP. OPERATIONS CHECKED GOOD.SDR SIMA20150712008Connector · missingEMERGENCY LIGHT STRIPS NR 3 & 5 MISSING FLOOR CONNECTORS. INSTALLED CONNECTORS PN MS39029-31-229 & 48-7191 ON WIRE NRS, W192-8678-22 NR 3 & W192-8760-22 NR 5 IAW SWPM 20-21-00.SDR SIMA20150712007Connector · missingEMERGENCY LIGHT STRIP NR 6, ACFT SIDE, MISSING CONNECTOR. INSTALLED CONNECTORS PN MS39029-31-229 & 48-7191 ON WIRE NUMBERS W192-8830-22 IAW SWPM 20-21-00.SDR RAIA201507120001Jackscrew · underservicedFLAP FAIL MESSAGE ON EICAS DURING APPROACH, EMERGENCY LANDING. MAINTENANCE INSPECTED AND SERVICED FLAP SCREWJACK ACTUATORS, OPS CHECK GOOD.SDR SIMA20150712002Inverter · inoperativeGALLEY DOOR UPPER EMER LIGHT INOPERATIVE. R & R EMER LIGHT DC & AC INVERTER 2 IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.SDR SIMA20150712001Flashlight · defectiveAFT EMER FLASHLIGHT STAYS ON ALL THE TIME. R & R AFT EMER FLASHLIGHT IAW AMM 33-50-16 STEPS 2 J 1, 3 I 4. OPERATIONS CHECKED GOOD.SDR SIMA20150711010Skin · damagedHAIL DAMAGE EVENT, REPLACE FWD FUSELAGE II SKIN, WIPER. R & R FWD FUSELAGE II SKIN IAW SRM 53-12-01 SI, 51-20-01, 51-20-03, 51-40-06, 51-40-02, CPM 51-21-04, ETN-EM-51-118 & ETN-EM-53-206.SDR SIMA20150711011Skin · damagedHAIL DAMAGE EVENT, REPLACE RT ELEVATOR UPPER CTR SKIN. R & R RT ELEVATOR UPPER CTR SKIN 145-27270-006 IAW SRM 55-20-01, 51-20-01 03, 51-40-02 06, ETN-EM-55-073 & ETN-EM-55-076.SDR SIMA20150711012Skin · damagedHAIL DAMAGE EVENT, REPLACE CTR FUSELAGE IV TOP SKIN. R & R CTR FUSELAGE IV TOP SKIN IAW SRM 53-24-01SI, SRM 51-2003, 51-40-03, 51-20-01, 51-40-02, 51-40-06, ETN-EM-51-118 & ETN-EM-53-265.SDR SIMA20150711009Skin · damagedHAIL DAMAGE EVENT, REPLACE LT ELEVATOR MID SKIN TIP. R & R LT ELEVATOR MID SKIN TIP IAW SRM 51-40-02, 51-2001, 512003, 51-40-06, 55-20-01, ETN EM-55-073R2 & ETN-EM-55-076.SDR SIMA20150711008Skin · damagedHAIL DAMAGE EVENT, REPLACE LT ELEVATOR OTBD UPPER SKIN TIP. R & R LT ELEVATOR OTBD UPPER SKIN TIP IAW SRM 55-20-01, 51-40-02, ETN-EM-55-073 & ETN-EM-55-076.SDR SIMA20150711006Skin · gougedSURROUNDING EXTERIOR STRUCTURE AT PAX WINDOW 4BC IA GOUGED. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-1464.SDR SIMA20150711005Skin · crackedRIGHT REAR FUSELAGE I, SKIN CRACKS AT FRAME 75 BETWEEN STRINGERS 1R & 3R. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR1462.SDR SIMA20150711003Light · inoperative12A EMER LIGHT ASSEMBLY INOPERATIVE. R & R EMER LIGHT ASSEMBLY IAW 33-50-00 AMM.SDR SIMA20150711004Sign · inoperativeFORWARD EMER EXIT SIGN AT 3B INOPERATIVE. R & R EMER LIGHT ASSEMBLY. OPERATIONS CHECKED GOOD IAW 33-50-00 AMM.SDR SIMA20150711002Flashlight · inoperativeRED LIGHT ON CAPTAINS FLASHLIGHT IS NOT ILLUMINATED. R & R CAPTAINS FLASHLIGHT ASSEMBLY IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.SDR SIMA20150711001Fan · inoperativeFLIGHT ATTENDANT REPORTED SMOKE FUMES IN CABINET BELOW CB PANEL IN GALLEY. PERFORMED GVI OF GALLEY AREA WITH NO DEFECTS NOTED. PERFORMED ENG ODOR EVENT IAW ETN-EM-72-034, NO DEFECTS NOTED. FOUND RECIRC FAN 2 INOPERATIVE, SEE LOG PAGE 3829649 ITEM 1. INSPECSDR ASOA20150711064Battery Pack · dischargedTHE CREW REPORTED THAT THE FWD EMERGENCY LIGHTS WERE FOUND TO BE INTERMITTENT. MAINTENANCE R & R THE AFFECTED EMERGENCY LIGHT BATTERY IN THE GALLEY, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150710035Control Valve · faultyPILOT REPORTED AFTER LANDING AT 120 KTS THE BRAKE EFFECTIVENESS WAS REDUCED BY HALF. INBD BRAKE INDICATION REMAINED COLD AND OTBD BRAKES IN THE YELLOW. MX R & R THE INBD BRAKE CONTROL VALVE AND NR 3 WHEEL SPEED TRANSDUCER WITH TAXI AND OPS CHECK GOOD. ACFT WASDR ASOA20150710036Battery Pack · dischargedTHE CREW REPORTED THE FIRST 3 AISLE PATH EMERGENCY LIGHT STRIPS DID NOT TEST. MAINTENANCE INSPECTED AND REPLACED THE NR 2 EMERGENCY LIGHT BATTERY PACK. OPS CHECKS WERE GOOD.SDR SIMA20150710002Light · inoperativeRIGHT OVERWING EMER LIGHT INOPERATIVE. RT OVERWING EMER LIGHT LAMP R & R IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR SIMA20150710003Light · inoperativeRIGHT EXTERIOR OVERWING EMER LAMP INOPERATIVE. R & R RT EXTERIOR OVERWING EMER LAMP IAW AMM 33-50-10-000-801-A & 33-50-10-400-801-A. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20150710001Acm · failedSMOKE IN THE COCKPIT AT CRUISE, DECLARED EMER. ACCOMPLISHED FIM TASK 21-20-00-810-801, SEE LOG PAGE 3924161 ITEM 1 FOR DISCREPANCY. FOUND LT ACM NEARLY SEIZED CAUSING SMOKE IN COCKPIT. DEFERRED LT PACK INOPERATIVE. R & R ACM IAW MM 21-51-03. OPERATIONS CHSDR SIMA20150709002Washer · missingFLIGHT ATTENDANT REPORTS MAIN PAX DOOR IS HARD TO OPEN & CLOSE. TROUBLE SHOT IAW FIM 52-18-00. INSTALLED MISSING WASHER ON MAIN DOOR UPPER SUPPORT LINK ON NUT SIDE. PERFORMED MAIN DOOR LUBRICATION ON ALL INTERNAL ACTUATING & LOCKING MECHANISMS, ALSO PERFORMSDR ASOA20150709146Door Sill · corrodedDURING C-CHECK THE SERVICE DOOR CENTER SILL WAS FOUND TO BE CORRODED. MAINTENANCE R & R THE SILL IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150709145Beam · corrodedDURING C-CHECK THE CARGO DOOR CUTOUT LOWER BEAM WAS FOUND TO BE CORRODED. MAINTENANCE R & R THE BEAM IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150709144Floor Support · corrodedDURING C-CHECK THE RT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 19. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EC5320-02057. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150709143VSkin · crackedDURING C-CHECK THE RT AFT SKIN AT FRAME 75 STR 2-3R WAS FOUND TO BE CRACKED. MAINTENANCE PERFORMED A DOUBLER REPAIR IAW EC5330-03041. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR UHLA201507080612Floor Support · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE CENTER OMEGA BEAM AT FRAMES 59 AND 61. REPAIRED IAW ETD2015-145-064770 AND SRM 53-24-10.SDR UHLA201507080611Floor Support · corrodedDURING INSPECTION, CORROSION WAS FOUND AT THE RT OMEGA BEAM AT FRAME 59-61. REPAIRED IAW SRM 53-24-10RE.SDR UHLA201507080610Frame · crackedDURING INSPECTION, THE LT FRAME 10 WAS FOUND TO BE CRACKED AT TOP. A SEGMENT OF FRAME 10 WAS R & R IAW SRM 51-40-02.SDR UHLA201507080609Window Frame · gougedDURING INSPECTION, A GOUGE WAS FOUND ON THE PILOTS WINDSHIELD CUTOUT UPPER FRAME. REPAIRED IAW ETD2015-145-064691.SDR UHLA201507080608Window Frame · cutDURING INSPECTION, A GOUGE WAS FOUND ON THE COPILOTS WINDSHIELD CUTOUT UPPER UPPER FRAME. THE GOUGE WAS REPAIRED IAW ETD2015-145-064691.SDR UHLA201507080607Frame · corrodedDURING INSPECTION, CORROSION WAS FOUND AT THE BAGGAGE DOOR LATERAL L SHAPE ON FRAME 65 AT THE LOWER DOOR STOP. THE SHEAR CLIP WAS REPLACED IAW ETD2015-145-065107 AND SRM 51-40-02.SDR SIMA20150708005Light · inoperativeAFT EMERGENCY LIGHT STRIP FOUND INOPERATIVE. LIGHT R & R IAW AMM 33-50-12. OPS CHECKED GOOD.
Back to Embraer EMB-145LR