Embraer EMB-145LR
Service difficulty reports · 36,797
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA20150409035Smoke Detector · false activationTHE CREW REPORTED A SMOKE INDICATION FROM THE CARGO BAY, THE QRH WAS FOLLOWED AND THE CARGO FIRE BOTTLES WERE DISCHARGED. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE ACFT, FOUND NO EVIDENCE OF SMOKE OR FIRE, OPERATIONALLY TESTED THE CARGSDR SIMA20150409005Duct · cutSTRONG BURNING SMELL WITH PACK 2 ON. COMPLIED WITH ETN EM 72-034 ENG ODOR EVENT NO EFFECTS NOTED. FOUND NR 2 PACK RAM AIR VLV DUCT CUT. R & R IAW AMM 21-25-01. OPERATIONS CHECKED GOOD.SDR SIMA20150409003Inverter · inoperativeEMERGENCY LIGHT ON AFT GALLEY WALL INOPERATIVE. R & R NR 3 EMER LIGHT INVERTER. OPERATIONS CHECKED GOOD IAW AMM 33-50-11.SDR ASOA20150409092Skin · corrodedDURING C-CHECK, FUSELAGE SKIN CORRODED BETWEEN FRAME 57-58, STR 20R-19R. REPAIRED SKIN IAW EC5330-03001. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150409091Door Sill · corrodedDURING C-CHECK, SERVICE DOOR AFT SILL CORRODED. REPAIRED SERVICE DOOR SILL IAW SRM 53-21-10. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150409090Skin · crackedDURING C-CHECK, SKIN CRACKS AROUND RIVETS FRAME 75 STR 2R-3R. REPAIRED SKIN CRACKS IAW EC5330-02997. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150409089Skin · crackedDURING C-CHECK, SKIN CRACKS AROUND RIVETS FRAME 78, STR 3L-5L. REPAIRED SKIN CRACKS AROUND RIVETS IAW EC 5330-03000. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150409088Frame · crackedDURING C-CHECK, FRAME 25 CRACKED AT STR 15R-16R. REPAIRED FRAME 25 IAW SRM 53-00-04. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20150409001Flashlight · missingFLASHLIGHT AT 18 BC MISSING. FLIGHT CREW PLACARDED IAW MEL 25-53.SDR SIMA20150408010Support · crackedLEFT LOWER AFT FAIRING SUPPORT IS CRACKED. REPAIRED AFT BELLY PANEL, LT LOWER ATTACHMENT SUPPORT IAW ERS-EM-5300-122.SDR UHLA2015040900264Floor Support · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE RT CENTER OMEGA BEAM BETWEEN FRAME 59 AND 61. THE BEAM WAS REPLACED IAW ETD 2015-145-033910.SDR UHLA2015040800263Floor Support · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE LT OMEGA BEAM SUPPORT AT FRAME 20. THE SUPPORT WAS REPLACED IAW SRM 51-40-02.SDR UHLA2015040800261Floor Support · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE CENTER OMEGA BEAM AT FRAME 59. THE BEAM WAS REPAIRED IAW ETD 2015-145-033589.SDR SIMA20150408008Light · inoperativeOVERWING LT AFT EMER LIGHT INOPERATIVE. R & R LT EXTERNAL EMER LIGHT LAMP ASSEMBLY IAW AMM 33-50-10. OPERATIONS CHECKED GOOD LT & RT EXTERNAL EMER LIGHTS.SDR SIMA20150408006Power Supply · inoperativeAISLE EMER LIGHT AT ROW 3 INOPERATIVE. R & R AISLE EMER LIGHT LAMP AT ROW 3 IAW AMM 33-50-08-000-801-A & 33-50-08-400-801-A, NO FIX. R & R NR 1 EMER LIGHT BATTERY POWER SUPPLY IAW WC 33-700-19. OPERATIONS CHECKED GOOD. EMER LIGHT BATTERY PN 2013-1ASMI, SN SDR SIMA20150408007Light · inoperativeCOCKPIT EMER LIGHT INOPERATIVE. R & R COCKPIT EMER LIGHT LAMP IAW AMM 33-50-08-000-801-A & 33-50-08-400-801-A.. OPERATIONS CHECKED GOOD.SDR SIMA20150408003Light · inoperativeRIGHT OVERWING EMER EXIT PSU LAMP INOPERATIVE. R & R RT OVERWING EXIT PSU LAMP. OPERATIONS CHECKED GOOD IAW AMM TASK 33-50-07-000-801-A & TASK 33-50-07-400-801-A.SDR SIMA20150408004Battery Pack · dischargedAFT OVERWING EMER LIGHT INOPERATIVE AT LOWER HAND. R & R BATTERY PACK & POWER SUPPLY IAW AMM 33-50-04. OPERATIONS CHECK FAILED, SEE NRWC 603-DFW-02208. CHARGER ASSEMBLY BATTERY PN BA5-0933-901 & SN C01494.SDR SIMA20150408001Roller · lack of lubeFLIGHT ATTENDANT REPORTS MAIN CABIN DOOR HARD TO OPEN. CHECKED & LUBRICATED MAIN DOOR FRAME ROLLERS IAW AMM 53-21-02. OPERATIONS CHECKED IAW AMM 52-10-01 SATISFACTORY.SDR ASOA20150408011Fuse · blownLT AND RT OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R FUSE ON NR 4 EMERGENCY LIGHT BATTERY TRAY. OPS CHECK GOOD.SDR SIMA20150407014Rib · crackedRIGHT WING RIB 5 HAS A 1 INCH CRACK LOCATED 1ST LARGE CUT OUT FROM AFT EDGE, 7:OO POSITION, OTBD SIDE. COMPLIED WITH REPLACEMENT OF RT WING RIB 5 IAW EO EM-57MR-595.SDR SIMA20150407013Support Bracket · crackedLEFT BLEED DUCT SUPPORT BRACKET JUST AFT OF FRAME 68 & BELOW THE FLOOR LEVEL IS CRACKED, APPROX 1 1/2 INCH. COMPLETED FABRICATION & INSTALLATION OF NEW BRACKET IAW SRM 51-40-02.SDR SIMA20150407012Skin · damagedTWO EACH OVERSIZED & ELONGATED HOLES AT FRAME 22 STRINGER 13 RT - 14 RT & ONE EACH JUST FWD OF FRAME 22 AT STRINGER 16 RT. REPAIRED TWO EACH OVERSIZED & ELONGATED HOLES IAW ERS-EM-53MR-1208.SDR UHLA2015040700265Threshold · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE SERVICE DOOR THRESHOLD. THE THRESHOLD WAS REPLACED IAW SRM 51-40-02.SDR SIMA20150407011Support Angle · crackedLEFT OMEGA BEAM SUPPORT ANGLE IS CRACKED. OTBD ANGLE BETWEEN FRAMES 47 - 48. R & R LT OMEGA BEAM SUPPORT ANGLE IAW SRM 53-23-02.SDR SIMA20150407010Door Sill · corrodedCARGO DOOR SILL IS CORRODED. REPLACED CARGO DOOR SILL IAW SRM 51-40-02.SDR SIMA20150407008Angle · crackedLEFT WING UPPER SURFACE L ANGLE SUPPORT FOR PANEL 195EL IS CRACKED. R & R THE LT WING UPPER SURFACE L ANGLE SUPPORT FOR PANEL 195EL IAW SRM 51-40-02.SDR SIMA20150407009Support Angle · crackedRIGHT OMEGA BEAM SUPPORT ANGLE IS CRACKED. INBD ANGLE BETWEEN FRAMES 47 - 48. R & R RT OMEGA BEAM SUPPORT ANGLES IAW SRM 53-23-02 & SRM 51-40-02.SDR SIMA20150407007Firewall · crackedAPU FIREWALL CRACKED ON THE AFT RT SIDE. COMPLETED REPAIR OF APU FIREWALL IAW ETN-EM-53-244 & EO-EM-53AD-1883.SDR SIMA20150407005Bracket · crackedRIGHT FWD PRE-COOLER BRACKET CRACKED. REPLACED RT FWD PRE-COOLER BRACKET IAW SRM 51-40-02 & ETN EM-54-056.SDR SIMA20150407006Bracket · crackedLEFT FWD PRE-COOLER BRACKET CRACKED. REPLACED LT FWD PRE-COOLER BRACKET IAW SRM 51-40-02 & ETN EM-54-056.SDR SIMA20150407002Light · inoperativeRIGHT AFT EMER EXTERIOR LIGHT FAILS TO ILLUMINATE. R & R BULB FOR RT AFT EMER EXTERIOR LIGHT. OPERATIONAL CHECKED GOOD.SDR SIMA20150407003Light · inoperativeCENTER AISLE OVERHEAD EMER LIGHT AT ROW 7 INOPERATIVE. R & R CTR AISLE OVERHEAD EMER LAMP AT ROW 7 IAW TASK 33-50-08-000-801-A & TASK 33-50-08-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20150406006Fitting · crackedFRAME 80 HAS A CRACKED SHEAR CLIP BETWEEN STRINGERS 6L & 7L 3/4 INCH LONG. R & R SHEAR CLIP BETWEEN STRINGERS 6L & 7L ON FRAME 80 IAW SRM 51-40-02.SDR SIMA20150406005Support Fitting · crackedSUPPORT CLIP AT FRAME 72 BETWEEN 16L & 17/L HAS A 1/2" CRACK. R & R SHEAR CLIP AT FRAME 72 BETWEEN STRINGER 16L & 17L IAW SRM 51-40-02.SDR SIMA20150406004Fitting · gougedRIGHT AILERON DAMPER FITTING IS GOUGED. RT AILERON PCA FITTING FLANGED BUSHINGS ARE PITTED, SCORED & GOUGED. INSTALLED NEW RT AILERON DAMPER FITTING IAW EO EM-27MR-112. REPLACED PCA FITTING IAW EO EM-27MR-112. FITTING PN 145-6982-610.SDR SIMA20150406003Door · corrodedBAGGAGE DOOR UPPER TRIM & LOWER TRIM SCREWS HOLES CORRODED. REMOVED CORROSION FROM BAGGAGE DOOR UPPER & LOWER TRIM SCREW HOLES IAW SRM 51-10-03 & ERS-EM-52MR-313.SDR UHLA2015040600238Wire Harness · damagedTHE CREW REPORTED THAT THEY RECEIVED A LANDING GEAR LEVER DISAGREE MESSAGE IN FLIGHT. THE CREW RETURNED TO FIELD AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE NLG UPLOCK SWITCHES AND THE NOSE LANDING GEAR UPLOCK PROXIMITY SWITCH HARNESS. OPS SDR ASOA20150406087Mount · crackedDURING C-CHECK ENGINE NR 1 FORWARD MOUNT POSSIBLE CRACK AT LOWER FWD HINGE. MAINTENANCE R & R ENGINE NR 1 FORWARD MOUNT LOWER FORWARD HINGE IAW EC5450-01139. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150406086Frame · corrodedDURING C-CHECK, FRAME 65 BETWEEN STRINGERS 16L-17L HAS CORROSION, LOCAL LEVEL 2. MAINTENANCE R & R FRAME 65 BETWEEN STRINGER 16L-17L IAW EC5330-02995 OIG. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150406085VThreshold · corrodedDURING C-CHECK, CARGO DOOR LOWER BEAM NEEDS REMOVED. MAINTENANCE R & R CARGO DOOR CUTOUT LOWER BEAM FRAME 65-68 IAW SRM 51-40-02 AND IS DETERMINED TO BE MAJOR IAW SOP 5702. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150406084VPartition · gougedDURING C-CHECK LT COCKPIT PARTITION UPPER AND LOWER GIUDE PIN HOLES ELONGATED. MAINTENANCE PERFORMED REPAIR TO LT COCKPIT UPPER AND LOWER GUIDE PIN HOLES IAW EC5320-02021. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20150406083Frame · gougedDURING C-CHECK, FRAME 70 GOUGED STRINGER 12R-13R. MAINTENANCE REPAIRED FRAME 70 STRINGER 12R-13R IAW EC5320-02022. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20150405004Yoke · crackedLEFT ENG FWD LOWER YOKE CRACKED IN CTR FWD UPPER RADIUS. COMPLIED WITH EO EM-54MR-386 R1 LT OR RT ENG FWD LOWER YOKE REPAIR & REPLACEMENT.SDR SIMA20150405003Wire · brokenNUMBER 6 EMER LIGHT STRIP HAS BROKEN WIRE. REPAIRED WIRE ON NR 6 EMER LIGHT STRIP IAW SWPM 20-21-00.SDR UHLA2015040500237Strut · low pressureTHE CREW REPORTED THAT THEY RECEIVED A LANDING GEAR AIR/GND FAIL MESSAGE. THE ACFT RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MAINTENANCE SERVICED THE NLG STRUT. OPS CHECKS AND LANDING GEAR SWINGS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR RAIA201504050001Apu · overheatedAPU OVER HEAT FOLLOWED BY APU FAIL EICAS MSGS DURING CLIMB, RETURNED TO BLOCK.SDR ASOA20150405034A/C Pack · odorTHE CREW REPORTED THAT THE PACK SYS HAD A STANGE ODOR. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE ACFT AND FOUND PACK 2 TO BE CAUSING THE ODOR. PACK 2 WAS PLACED ON MEL, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE. MAINTENANCE OPERSDR SIMA20150404001Structure · bentLEFT LE NR 1 INBD FLANGE BENT. REPAIRED LT LE NR 1 INBD FLANGE IAW ERS-EM-5700-418.SDR RAIA201504040002Bulb · inoperativeSERVICE DOOR EMERGENCY EXIT LIGHT NR 2 IS INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECKED GOOD.
Back to Embraer EMB-145LR