Embraer EMB-145LR
Service difficulty reports · 36,799
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20140416007Power Supply · inoperativePAX DOOR EMERGENCY LIGHT INOPERATIVE ON DOOR HINGE. REMOVED & INSTALLED NR 1 EMERGENCY BATTERY POWER SUPPLY IAW WORK CADR 33-700-17 & 33-700-19, OPERATIONAL CHECKED GOOD.SDR SIMA20140416006Seal · failedCAPTAIN`S WINDSHIELD HUMP SEAL APPROXIMATELY 8 INCHES TOP RT CAME LOOSE IN FLIGHT & FINALLY BROKE OUT. REPAIRED SEAL IAW AMM 56-10-01. ITEM 2. NO OTHER DEFECTS NOTED.SDR SIMA20140416005Power Supply · inoperativeBOTH OVERWING EMERGENCY LIGHTS ARE INOPERATIVE. TROUBLESHOT WITH OVERWING EMERGENCY LIGHT ASSEMBLY & PROBLEM PERSISTED. R & R NR 4 POWER SUPPLY & BATTERY HOLDER ASSEMBLY IAW AMM 33-50-04. OPS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20140416002Flashlight · inoperativeFIRST OFFICER`S EMERGENCY FLASHLIGHT CHARGE LIGHT IS NOT LIT. R & R FIRST OFFICER`S EMERGENCY FLASHLIGHT ASSEMBLY AS REQUIRED, OPERATIONS CHECKED OK IAW CMM 25-60-11.SDR SIMA20140416003Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R MAIN DOOR EMERGENCY LIGHT LAMP IAW AMM TASK 33-50-06-000-801-A & 33-50-06-400-801-A, OPERATIONS CHECKED GOOD.SDR SIMA20140416004Epsu · inoperativeLAST 3 FLOOR PROXIMITY LIGHTS ARE INOPERATIVE. R & R ESPU NR 4 IAW WC 33-700-19, OPERATIONS CHECKED GOOD.SDR SIMA20140416001Roller · lack of lubeFLIGHT ATTENDANT REPORTS MAIN CABIN DOOR DIFFICULT TO OPEN. LUBRICATED MAIN DOOR FWD UPPER ROLLER OPERATED DOOR SEVERAL TIMES IAW AMM 52-10-00, NORMAL OPERATION NOTED.SDR SIMA20140415013Antenna · faultyELT FAILED BIT TEST, THREE FLASHES SHOWS A 406.025 MHZ TRANSMITTER PROBLEM. R & R ELT ANTENNA IAW AMM 25-61-03 & ETN GN-34-013. OPERATIONS CHECKED GOOD IAW AMM 25-61-00.SDR SIMA20140415012Light · crackedLEFT FLOOR EMERGENCY LIGHT SWITCH NR 7 IS CRACKED. REPLACED EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140415011Bracket · debondedRIGHT EMERGENCY EXIT INNER LINING HAS BROKEN SECURING POINT. INSPECTED RT EMERGENCY EXIT INNER LINING FOUND THAT IT WAS NOT BROKEN, JUST BRACKET WAS DE-BONDED FROM PANEL. RE-BONDED BRACKET TO PANEL IAW AMM 25-00-00.SDR SIMA20140415010Bracket · unsecureLEFT EMERGENCY EXIT DOOR LINING HAS 3 BRACKETS THAT CAME UNGLUED THAT HOLDS LINING ONTO DOOR. RE-BONDED 3 BRACKETS ON TO LT EMERGENCY EXIT DOOR LINING IAW AMM 25-00-00.SDR SIMA20140415017Connector · brokenFLOOR PROXIMITY STRIP LIGHTS WIRE CONNECTOR BROKEN, PAX CTR FLOOR PANEL JUST FWD OF LAVATORY ENTRANCE. R & R FLOOR PROXIMITY STRIP LIGHTS WIRE CONNECTOR AT PAX CTR FLOOR PANEL JUST FWD OF LAVATORY ENTRANCE IAW SWPM 20-50-01. OPERATIONS CHECKED GOOD IAW AMM 3SDR SIMA20140415008Trunnion · crackedRIGHT WING MLG AFT TRUNNION FITTING IS CRACKED. R & R RT WING MLG AFT TRUNNION IAW ERS-EM-57MR-141.SDR SIMA20140415007Light · crackedLEFT FLOOR EMERGENCY LIGHT STRIP NR 5 IS CRACKED. REPLACED LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140415006Frame · crackedFRAME 72 IS CRACKED AT FLOOR & WALL SUPPORT BETWEEN STRINGERS 15L & 16L. COMPLIED WITH ERS-EM-53MR-439.SDR SIMA20140415014Connector · brokenEMERGENCY LIGHT STRIP NR 2 HAS A CONNECTOR BROKEN OFF OF WIRE, OLD CONNECTOR TAPED TO WIRE. R & R SPLICE ON NR 2 LIGHT STRIP IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20140415015Light · brokenRIGHT NR 1 CTR AISLE PROX STRIP BROKEN. R & R RT NR 1 CTR AISLE PROX STRIP IAW AMM 33-50-12.SDR SIMA20140415016Wire · brokenFORWARD EMERGENCY FLOOR LIGHT STRIP FOUND WIRES BROKEN TO LIGHT STRIP. R & R FWD EMERGENCY FLOOR LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140415009Support · crackedWEB SUPPORT BENEATH THE LT SIDE COCKPIT AILERON TORQUE TUBE IS CRACKED AT THE LIGHTENING HOLE, APPROXIMATELY 1/2 INCH IN LENGTH. REPAIRED DAMAGED AREA IAW ERS-EM-53MR-421.SDR RAIA201404150001Coupling · disconnectedDURING CLIMB AT AROUND 10000 FT, THERE WAS A LOUD POPPING NOISE FOLLOWED BY LOUD NOISE OF AIR RUSHING UNDER CABIN FLOOR AND DIFFICULTY MAINTAINING CABIN PRESSURIZATION FOLLOWED BY NR 2 A/C PACK OVERLOAD MESSAGE, ACFT RETRURNED. MAINTENANCE INSPECTED AND FOUNDSDR SIMA20140415003Smoke Detector · false activationBAGG SMOKE WARNING CAME ON JUST PRIOR TO LANDING, BAGG EXTINGUISHER WAS PRESSED WARNING REMAINED ON CFR CALLED. TRANSFERRED TO NRWC 660-MIA-01582. R & R BAGG COMPARTMENT HIGH RATE & METERING EXTINGUISHER BOTTLE IAW AMM 26-23-01. R & R BAGG SMOKE TEST RELAY SDR SIMA20140415001Support · brokenBUTTERFLY KNOB ON CRASH AXE BROKEN. R & R CRASH AXE SUPPORT ASSEMBLY IAW CMM 25-11-71 & STANDARD PRACTICES.SDR ASOA20140414062Pitot System · contaminatedCREW REPORTED AT FL 370 A NOTICEABLE ICE BUILD UP ON THE UNPROTECTED SURFACES AS WELL AS THE TAT. SHORTLY AFTER IAS AND ALT INSTRUMENTS BEGAN TO FAIL FOLLOWED BY A NR 2 PACK OVERHEAT MESSAGE ON THE EICAS DISPLAY. DECLARED AN EMERGENCY AND BEGAN AN IMMEDIATE SDR ASOA201404140350Coffeemaker · failedCREW REPORTED COFFEE POTS WERE NOT WARMING AND A BURNING ODOR. ODOR DISSIPATED WHEN THEY WERE TURNED OFF. MAINTENANCE INSPECTED AND REPLACED THE COFFEE BREWER LT RAIL AND PUMP ASSEMBLY. OPS CHECKS WERE GOOD.SDR SIMA20140414005Charger · inoperativeCABIN CEILING DIRECTION EMERGENCY LIGHT INOPERATIVE. R & R NR 4 EMERGENCY BATTERY & CHARGER, OPERATIONS CHECKED GOOD IAW AEWC 33-700-19 CC 678051.SDR SIMA20140414006Light · inoperativeLEFT AFT OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. R & R LT AFT OVERWING EMERGENCY EXIT LIGHT LAMP, OPERATIONS CHECKED GOOD IAW AMM 33-50-10.SDR SIMA20140414003Door · lack of lubeACFT MAIN ENTRY DOOR HARD TO OPEN, HANDLE HARD TO MOVE FULLY UP. LUBED MAIN DOOR IAW AMM 52-18-00.SDR SIMA20140414002Roller · lack of lubeMAIN CABIN DOOR HANGS UP ON SOMETHING WHEN OPENING. LUBRICATED MAIN CABIN DOOR ROLLERS, OPERATIONS CHECKED GOOD IAW AMM 52-10-01.SDR SIMA20140414001Carbon Seal · damagedNR 1 ENG OIL LEAK IN FLIGHT. IN CRUSE FLIGHT OIL LEVEL WAS 6 QT, LANDED WITH 3QT. REPLACED AGB BREATHER CARBON SEAL & O RING IAW MM 72-63-10. LEAK CHECKED GOOD IAW NRWC 669-ORD-01585 RII LAW 173773.SDR SIMA20140413010Light · inoperativeNR 1 FLOOR EMERGENCY LITE STRIP NOT WORKING DURING TEST. R & R NR 1 FLOOR EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140413007Charger · inoperativeLEFT EXTERNAL OVERWING EMERGENCY LAMP INOPERATIVE. R & R NR 4 BATTERY POWER SUPPLY & CHARGER IAW AE WC 33-700-17 & 33-700-19, OPERATIONS CHECKED GOOD.SDR SIMA20140413001Warning System · false activationAFTER ROTATION BAGGAGE DOOR OPEN INDICATION, FOUND CARGO STRAP IN DOOR NO INDICATION ON GND, CHECKED OK FOR SERVICE.SDR SIMA20140413006Flashlight · missingFLIGHT ATTENDANT`S FLASHLIGHT MISSING. REPLACED FLIGHT ATTENDANT`S FLASHLIGHT IAW STANDARD PRACTICES.SDR SIMA20140413005Light · inoperativeEMERGENCY LIGHTS OVER FLIGHT ATTENDANT`S SEAT NOT WORKING. R & R COURTESY LIGHT LAMP IAW AMM 33-26-04. OPERATIONS CHECKED GOOD. LAMP USED FROM SPARE BULB KIT.SDR SIMA20140412002Holder · brokenFLIGHT ATTENDANT'S EMERGENCY FLASHLIGHT HOLDER BROKEN. R & R FLASHLIGHT BRACKET IAW AMM 33-50-16, OPERATIONS CHECKED GOOD.SDR ASOA20140413081Shear Tie · crackedSHEAR TIE CRACKED AT FRAME 24, STRINGERS 16 AND 17R. R & R SHEAR TIE.SDR ASOA20140413080Floor Support · corrodedCORROSION BEYOND LIMITS AROUND FASTENERS IN RT OTBD FLOOR SUPPORT AT FRAME 20. R & R FLOOR SUPPORT.SDR CHQA20140411118Doubler · corrodedDURING INSPECTION, A PREVIOUS REPAIR DOUBLER ON THE RT OMEGA BEAM AT FRAME 61 WAS FOUND TO BE CORRODED. THE DOUBLER WAS REPLACED IAW ETD 2014-145-031092.SDR SIMA20140411003Skin · damagedHOLE IN RUDDER II LT SKIN LOWER AFT CORNER NEAR TE. REPAIRED RUDDER II SKIN IAW AE ERS-EM-55MR-069.SDR CHQA20140411110O-Ring · leakingCREW REPORTED THAT THEY RECEIVED A BLEED 1 LEAK MSG AFTER TAKEOFF. THE CREW RETURNED TO FIELD & LANDED WITHOUT INCIDENT. REPLACED THE O RING AT JOINT 3. OPERATIONAL & LEAK CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA20140411002Battery · dischargedCAPTAIN` S EMERGENCY FLASHLIGHT INOPERATIVE. R & R CAPTAIN`S EMERGENCY FLASHLIGHT BATTERY IAW ETN-EM-33-038, OPERATIONS CHECKED GOOD.SDR SIMA20140411001Latch · openAFTER TAKEOFF FUELING PANEL DOOR LIGHT ON & MSG ON EICAS. FOUND FUEL DOOR LATCH OPEN, CLOSED LATCH. FUEL DOOR INDICATION OPERATIONS CHECKED GOOD IAW AMM 52-78-00.SDR ASOA20140410033CWire Harness · burnedTHE CREW REPORTED BURNING ODOR IN THE CABIN AND GALLEY AREA. MAINTENANCE INSPECTED AND FOUND THE OVERHEAD LIGHT AT 5A TO BE BURNED. MAINTENANCE R & R THE CABIN LIGHT ELECTRICAL HARNESS. ALSO RELAMPED LIGHT. OPS CHECKS WERE GOOD.SDR SIMA20140410003Battery · dischargedAFT NR 4 EMERGENCY LIGHT INOPERATIVE. R & R NR 4 BATTERY & CHARGER IAW AMM 33-50-04, OPERATIONS CHECKED GOOD.SDR SIMA20140410004Light · inoperative7A AISLE EMERGENCY LIGHT CEILING INOPERATIVE. R & R 7A CEILING AISLE EMERGENCY LIGHT BULB IAW AMM 33-50-08. OPERATIONS CHECKED GOOD IAW 33-50-00.SDR SIMA20140410006Flashlight · missingFLIGHT ATTENDANT`S FLASHLIGHT ABOVE JUMP SEAT MISSING. INSTALLED FLIGHT ATTENDANT`S FLASHLIGHT AT JUMP SEAT IAW CMM 25-60-02.SDR ASOA20140411079Profile · corrodedCORROSION AROUND NUTPLATES ON BOTTOM OF PAX DOOR IS OUT OF LIMITS. R & R PROFILE.SDR ASOA20140411078Floor Support · crackedCRACK IN INBD SPLICE ANGLE UNDER FLOOR SUPPORT AT LT OMEGA BEAM BETWEEN FRAMES 16-17. R & R CRACKED SPLICE ANGLE.SDR ASOA20140411077TFloor Support · crackedOTBD RT OMEGA BEAM SUPPORT CRACKED AT FRAME 47. R & R BEAM SUPPORT.SDR ASOA20140411076Seat Track · corrodedCORROSION IN MULTIPLE AREAS ALONG LT SIDEWALL SEAT TRACK SUPPORT. CORROSION OUT OF LIMITS AFTER BLEND-OUT. R & R SUPPORT.
Back to Embraer EMB-145LR