Embraer EMB-145LR
Service difficulty reports · 36,799
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CHQA20140423141Structure · corrodedDURING INSPECTION, CORROSION WAS FOUND & A CRACK WAS FOUND ON THE STRUCTURE UNDER THE MIDDLE FWD STAIR SUPPORT ON THE MAIN ENTRY DOOR. THE STRUCTURE UNDER THE MIDDLE FWD STAIR SUPPORT WAS REPLACED IAW SRM 51-40-02.SDR CHQA20140423140Structure · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE INNER STRUCTURE OF THE LOWER FWD AREA OF THE MAIN ENTRY DOOR. THE INNER STRUCTURE OF THE LOWER FWD AREA OF THE MAIN ENTRY DOOR WAS REPLACED IAW SRM 51-40-02.SDR CHQA20140423139Reinforcement · corrodedDURING INSPECTION, CORROSION WAS FOUND AROUND THE THE REINFORCEMENT FOR THE BOTTOM DOOR STOP INSIDE THE AFT STRUCTURE OF THE MAIN ENTRY DOOR. THE DOOR STOP WAS REPLACED IAW SRM 51-40-02.SDR CHQA20140423138Door Frame · corrodedDURING INSPECTION, CORROSION WAS FOUND ON FRAME 65 AT THE CARGO DOOR FRAME JUST BELOW THE DOOR BUMPER PLATE. THE FRAME WAS REPAIRED IAW ETD 2014-145-034902.SDR CHQA20140423137Fitting · damagedDURING INSPECTION, THE LT AILERON ACTUATOR ATTACH LUG OTBD HAT BUSHING WAS FOUND TO BE MIGRATING AWAY FROM THE LUG. THE LT AILERON PCA FITTING WAS REPLACED IAW SRM 51-20-01 & SRM 51-40-02.SDR CHQA20140423133Door · chafedDURING INSPECTION, A CHAFE WAS FOUND ON THE INNER AFT FACE OF THE MAIN ENTRY DOOR FOLDING FLAP. THE CHAFE WAS REPAIRED IAW ETD 2014-145-034319.SDR RAIA201404250001Bulb · inoperativeSIDEWALL EMERGENCY EXIT LIGHT AT ROW 23 IS INOPERATIVE. MAINTENANCE INSPECTED AND REPLACED THE BULB, OPS CHECKED GOOD.SDR SIMA20140423007Fitting · crackedSHEAR CLIP AT FRAME 14 RT SIDE BETWEEN STRINGER 6R - 8R CRACKED. REPAIRED SHEAR CLIP AT FRAME 14 RT SIDE BETWEEN STRINGER 6R - 8R IAW ERS-EM-53MR-424 PART A.SDR RAIA201404230001Bulb · inoperativeMAIN PASSENGER DOOR EXTERIOR FLOOD LIGHT ON BOTTOM SIDE OF DOOR IS INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECK GOOD.SDR SIMA20140423004Unknown · malfunctionedAIRCRAFT WOULD NOT PRESSURIZE ON TAKEOFF. RETURNED FOR EMERGENCY LANDING. CABIN ALTITUDE REMAINED WITH AMBIENT RETURNED FOR LANDING AT 6000' ALTITUDE. ACCOMPLISHED PRESSURIZATION FUNCTIONAL TEST OF AUTOMATIC & MANUAL MODE IAW AMM 21-31-00, FOUND NO DISCREPSDR SIMA20140423005Strap · brokenFIRST OFFICER`S SMOKE GOGGLE STRAP BROKEN. INSTALLED FIRST OFFICER'S SMOKE GOGGLE STRAP AS REQUIRED.SDR ASOA20140424082Power Supply · inoperativeLEFT AND RT OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R NR 4 BATTERY POWER SUPPLY. OPS CHECKED GOOD.SDR SIMA20140423001Mechanism · lack of lubeCABIN DOOR IS DIFFICULT TO OPEN FROM INSIDE THE ACFT. LUBRICATED MAIN DOOR MECHANIC SYS, OPERATION OF DOOR WORKING GOOD AMM 52-10-01.SDR CHQA20140422135Support · corrodedDURING INSPECTION, THE LT SIDEWALL SEAT TRACK SUPPORT WAS FOUND TO BE CORRODED AT FRAME 45. THE SEAT TRACK SUPPORT WAS REPLACED IAW SRM 51-40-02.SDR CHQA20140422134Doubler · corrodedDURING INSPECTION, A PREVIOUS REPAIR DOUBLER ON THE LT FWD OMEGA BEAM FWD CAP AT FRAME 20 WAS FOUND TO BE CORRODED. THE REPAIR DOUBLER WAS REPLACED IAW SRM 51-40-02.SDR SIMA20140422003Bracket · crackedDURING HMBV INSPECTION FOUND THE RT MLG BAY AFT FAIRING SUPPORT PLATE IS CRACKED. R & R BRACKET IAW AMM CHAPTER 20-10-11.SDR SIMA20140422002Firewall · crackedDURING HMBV INSPECTION FOUND APU FIREWALL LOWER RT SIDE JUST ABOVE THE MOUNTING BRACKET HAS A 1 INCH CRACK BY A RIVET. COMPLIED WITH REPAIR OF THE APU FIREWALL LOWER RT SIDE IAW EO-EM-53AD-1883 PART C STEP 5.SDR ASOA20140422049Light · malfunctionedPILOT REPORTED THE OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. MX RESET SYS AND PERFORMED OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20140422001Inverter · inoperativeRIGHT INTERIOR OVERWING EXIT SIGN INOPERATIVE. R & R EMERGENCY LIGHT DC & AC INVERTER NR 5 IAW AMM 33-50-11, OPERATIONS CHECKED GOOD.SDR RAIA201404220001Door Sill · corrodedPASSENGER DOOR SILL CORRODED. MAINTENANCE REPLACED DOOR SILL.SDR SIMA20140421011Fitting · crackedDURING HMBV INSPECTION FOUND FRAME 73 HAS CRACKED SHEAR CLIP & FRAME SUPPORT BETWEEN STRINGERS 15L & 16L. R & R FRAME 73 SHEAR CLIP & FRAME SUPPORT BETWEEN STRINGERS 15L & 16L IAW SRM 51-40-02.SDR SIMA20140421010Frame · crackedDURING HMBV INSPECTION FOUND RT COCKPIT FRAME 10 IS CRACKED ON THE TOP END AT THE RIVET HOLES. REMOVED & INSTALLED NEW FRAME IAW SRM 51-40-02.SDR SIMA20140421008Support Bracket · crackedDURING HMBV INSPECTION FOUND LT COCKPIT FRAME 10 FWD SUPPORT BRACKET IS CRACKED BENEATH THE DV WINDOW. R & R LT COCKPIT FRAME 10 FWD SUPPORT BRACKET IAW SRM 51-40-02.SDR SIMA20140421009Support Bracket · crackedDURING HMBV INSPECTION FOUND RT COCKPIT FRAME 10 FWD SUPPORT BRACKET CRACKED BENEATH THE DV WINDOW. R & R RT COCKPIT FRAME 10 FWD SUPPORT BRACKET IAW SRM 51-40-02.SDR SIMA20140421007Fitting · crackedDURING HMBV INSPECTION FOUND SHEAR CLIP CRACKED AT FRAME 24 AT STRINGER 15RT. R & R SHEAR CLIP AT FRAME 24 AT STRINGER 15RT IAW SRM 51-40-02.SDR SIMA20140421006Fitting · crackedDURING HMBV INSPECTION FOUND SHEAR CLIP CRACKED AT FRAME 24 BETWEEN STRINGER 15RT & 16RT. R & R SHEAR CLIP AT FRAME 24 AT STRINGER 15RT & 16RT IAW SRM 51-40-02.SDR SIMA20140421005Support Bracket · crackedDURING HMBV INSPECTION FOUND FRAME 68 CARGO DOOR HOLD OPEN STRUT RETAINER CUP. AFT SIDE SUPPORT BRACKET IS CRACKED. R & R FRAME 68 CARGO DOOR HOLD OPEN STRUT RETAINER CUP, AFT SIDE SUPPORT BRACKET IAW SRM 51-40-02.SDR CHQA20140921121Duct · crackedCREW REPORTED THAT THEY RECEIVED A BLEED 2 LEAK MSG DURING CLIMB OUT. THE CREW RETURNED TO FIELD & LANDED WITHOUT INCIDENT. SECURED THE BLEED VLV, CLOSED & DEFERRED THE BLEED 2 SYS. THE DEFERRAL WAS CLEARED LATER THAT DAY WHEN THE DUCT FROM THE RT ENG BLEEDSDR SIMA20140421002Light · inoperativeAISLE AFT OVERHEAD EXIT EMERGENCY LIGHT INOPERATIVE. R 7 R AISLE AFT OVERHEAD EXIT LIGHT ASSEMBLY. OPERATIONS CHECKED GOOD ALL WORK PERFORMED IAW AMM CH 33-50-15.SDR SIMA20140420005Inverter · inoperativeEMERGENCY PROXIMITY LIGHTS AFT OF EMERGENCY EXIT INOPERATIVE. R & R NR 6 EMERGENCY LIGHT INVERTER IAW AMM 33-50-11, OPERATIONS CHECKED GOOD.SDR SIMA20140420006Wire · brokenNR 8 EMERGENCY PROXIMITY LIGHT STRIP WIRES BROKEN. R & R NR 8 EMERGENCY PROXIMITY LIGHT STRIP AS REQUIRED.SDR SIMA20140420007Wire · damagedNR 4 & NR 6 EMERGENCY PROXIMITY LIGHT STRIP HAS DAMAGED WIRES. R & R NR 4 & NR 6 EMERGENCY PROXIMITY LIGHT STRIP AS REQUIRED.SDR SIMA20140420004Inverter · inoperativeEMERGENCY PROXIMITY LIGHTS NR 1, 2, 3 & FWD LOWER SERVICE DOOR EMERGENCY LIGHT INOPERATIVE. R & R EMERGENCY LIGHT INVERTER NR 2 & NR 3 IAW AMM 33-50-11. OPERATIONS CHECKED GOOD.SDR SIMA20140420003Roller · lack of lubeFLIGHT ATTENDANT REPORTED MAIN CABIN DOOR HARD TO OPEN & CLOSE. SERVICED MAIN DOOR ROLLERS IAW AMM 53-21-02, OPERATIONS CHECKED GOOD.SDR SIMA20140420001Charger · inoperativeLEFT EXTERNAL OVERWING EMERGENCY LAMP INOPERATIVE. R & R LT EXTERNAL OVERWING LAMP IAW AMM 33-50-10-000-801-A & 33-50-10-400-801-A, NO FIX. R & R NR 4 EMERGENCY BATTERY & CHARGER ASSEMBLY IAW WC 33-700-19, NO FIX. TROUBLE SHOT HARNESS USING WM 33-50-50 NO FSDR ASOA20140419036Bolt · shearedDURING FLIGHT, AFTER A SERIES OF BUMPS OR WHAT SOUNDED LIKE A BACKFIRE. NR 2 ENGINE ITT SPIKED INTO THE RED FOLLOWED BY NR 2 ENGINE OUT. RESTART WAS SUCCESSFUL, FOLLOWED SHORTLY BY REPEAT OF UNCOMMANDED ENGINE SHUTDOWN. THE ACFT LANDED WITHOUT FURTHER INCIDESDR RAIA201404190002Light · inoperativeCEILING EMERGENCY EXIT LIGHT IN GALLEY IS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT IN THE GALLEY.SDR RAIA201404190001Sensor · dirtyLAVATORY SMOKE INDICATION CAME ON DURING CRUISE, THERE WAS NO SMOKE OR ODOR REPORTED. MAINTENANCE INSPECTED LAVATORY AND NO DEFECTS WERE FOUND. MAINTENANCE CLEANED SENSOR AND OPS CHECK GOOD.SDR CHQA20140418111Strut · underservicedCREW REPORTED THAT AFTER TAKEOFF THEY RECEIVED A LG AIR & GND FAIL MSG. THE CREW RETURNED TO FIELD & LANDED WITHOUT INCIDENT. THE ACFT WAS FOUND SAFE FOR FERRY FLIGHT & FLEW TO KCMH FOR REPAIR. REPACKED THE NOSE LG STRUT. OPERATIONAL CHECKS WERE GOOD WITH SDR RAIA201404170006Floor Support · corrodedLEFT OMEGA BEAM GUSSET AT FRAME 59-FRAME 61 HAS LEVEL 2 CORROSION. MAINTENANCE REPLACED LT OMEGA BEAM GUSSET.SDR RAIA201404170005Structure · corrodedLEFT SILL FROM FRAMES 61-65 CORRODED. REPLACED LT SILL.SDR RAIA201404170004Structure · corrodedRIGHT SILL FRAME 59-61 HAS LEVEL 2 CORROSION. REPLACED RT SILL.SDR RAIA201404170003Floor Support · corrodedRIGHT OMEGA BEAM GUSSET AT FRAMES 59-61 CORRODED. MAINTENANCE REPLACED RT GUSSET.SDR RAIA201404170002Floor Support · corrodedCENTER OMEGA BEAM GUSSET AT FRAMES 59-61 CORRODED. MAINTENANCE REPLACED CENTER OMEGA BEAM GUSSET.SDR RAIA201404170001Structure · corrodedLEFT SILL AT FRAMES 59-61 CORRODED. MAINTENANCE REPLACED LT SILL.SDR ASOA20140417046Coffeemaker · dirtyF/A REPORTED AN ODOR COMING FROM THE GALLEY COFFEEMAKERS. MAINTENANCE CLEANED THE WARMERS ON BOTH COFFEE BREWERS AND PERFORMED AN OPS CHECK, CHECKED GOOD, WITH NO BURNING ODORS DETECTED. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20140417005Conditioner · faultyDURING TAKEOFF MC FUEL IMBALANCE & MASTER WARNING FUEL 1 LOW LEVEL LIGHTS ILLUMINATED AS SOON AS THE GEAR RETRACTED. RESET FUEL CONDITION UNIT IAW AMM 28-41-01, OPERATIONS CHECKED GOOD, FUEL INDICATOR OK.SDR SIMA20140417004Battery · dischargedLT & RT OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R BATTERY POWER SUPPLY & BATTERY IAW AMM 33-50-04, OPERATIONS CHECKED GOOD.SDR SIMA20140417002Holder · brokenFLASHLIGHT HOLDER REAR CABIN FLASHLIGHT BROKEN. R & R FLASHLIGHT SYS IAW 25-60-00.SDR SIMA20140417001Control Panel · defectiveDURING DESCENT & APPROACH TO MIA, FLIGHT ATTENDANT REPORTS FAINT SMOKE SMELL IN GALLEY. AOM1 PROCEDURES COMPLIED WITH. INSPECTED GALLEY & FOUND ELEC CONTROL PANEL TO THE GALLEY, THE BOARD WITH BURN SMELL. R & R GALLEY ELEC CONTROL PANEL, OPERATIONS CHECKED
Back to Embraer EMB-145LR