Embraer EMB-145LR
Service difficulty reports · 36,799
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA20140308034RDisplay · shortedPILOT REPORTED DURING PARKING CHECK, THE CAPTAINS PFD WENT BLANK AND SOON AFTER, SMOKE WAS NOTICED RISING FROM BEHIND PFD. MAINTENANCE R & R NR 1 PFD DU-870 WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140308033Light · arcedA BURNED PLASTIC ODOR REPORTED IN CABIN BY SEAT 2A. MX INSPECTED ACFT CABIN AND FOUND SEAT 6A LIGHT TO BE THE CAUSE. MX R & R SEAT 6A CEILING LIGHT ASSY WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20140308002Flashlight · inoperativeFWD CABIN EMERGENCY FLASHLIGHT INOPERATIVE. R & R FWD CABIN EMERGENCY FLASHLIGHT IAW AMM 33-50-16, OPERATIONS CHECKED GOOD.SDR ASOA20140307032Flapper Valve · leakingPILOT REPORTED AFTER TAKEOFF RT WING LEAKING FUEL TANK NR 2 SHOWING 800 LBS LOWER THAN TANK 1 FUEL IMBALANCE AND TANK NR 2 DASHED OUT. MX R & R THE RT WING FLAPPER VALVE WITH LEAK CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20140307008Hydraulic System · lowHYD SYS NR 1 LOW QTY AT FL 350 GEAR & FLAPS UP MACH 72 NO ICE. COMPLIED WITH HYD SYS TRANSFER IAW ETN EN-27-023, CHECKED GOOD, OK FOR SERVICE.SDR SIMA20140307003Wire · brokenNR 7 EMERGENCY LIGHT STRIP WIRE BROKEN. R & R EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140307004Wire · brokenNR 4 EMERGENCY LIGHT STRIP WIRE BROKEN. R & R EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140307005Connector · missingNR 5 EMERGENCY LIGHT STRIP WIRE CONNECTORS MISSING. REPLACED CONNECTORS ON THE EMERGENCY LIGHT STRIP NR 5 WIRES IAW SWPM 20-00-03 & 20-50-01.SDR SIMA20140307006Insulation · damagedNR 3 EMERGENCY LIGHT STRIP WIRE INSULATION DAMAGED. REPAIRED WIRE INSULATION IAW SWPM 20-21-00 STEP 7.SDR SIMA20140307007Fitting · corrodedFRAME 65 SHEAR CLIP CORRODED. REPAIRED IAW EO EM-53MR-1129.SDR SIMA20140307001Flashlight · inoperativeCAPTAIN'S FLASHLIGHT WILL NOT ILLUMINATE. R & R CAPTAIN'S FLASHLIGHT IAW AMM 33-50-16, OPERATIONS CHECKED GOOD AT THIS TIME.SDR ASOA20140307024Switch · failedNR 2 PACK OVERLOAD ASSOCIATED WITH BURNING ODOR THROUGHOUT THE ACFT AND LIGHT SMOKE. MAINTENANCE R & R NR 2 PACK OVERTEMP SWITCH. OPS CHECKED GOOD, NO ODOR OR LIGHT SMOKE DETECTED IAW AMM 21-51-08, - IPC FIG 27, ITEM 270. THE ACFT WAS APPROVED FOR RETURN TOSDR CHQA20140306082Floor Support · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE LT OMEGA BEAM AT FRAME 20. THE FRAME WAS REPAIRED IAW SRM 53-0010 & SRM 51-40-02.SDR CHQA20140306081Floor Support · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE LT OMEGA BEAM AT FRAME 23. THE LT OMEGA BEAM WAS REPAIRED IAW ETD 2014-145-014567.SDR CHQA20140306080Service Door · corrodedDURING INSPECTION THE SERVICE DOOR BOTTOM STRUCTURE ATTACHMENT FOR THE LINER NUT PLATE AREAS WAS FOUND TO BE CORRODED. THE SERVICE DOOR WAS REPAIRED IAW ETD 2014-145-019393-A.SDR RAIA201403060003Clamp · unsecureCABIN DID NOT PRESSURIZE DURING CLIMB IN AUTO MODE, RETURNED BLOCK. MAINTENANCE INSPECTED AND SECURED LOOSE OUTFLOW VALVE CLAMP, OPS CHECK GOOD.SDR SIMA20140306008Cup · damagedRT EMERGENCY EXIT LOWER RECESS CUP DAMAGED. INSTALLED NEW RT EMERGENCY EXIT LOWER RECESS CUP IAW SUB TASK 25-23-03-420-001 STEP I 1 D PART TASK.SDR ASOA20140306031RDuct · loosePILOT REPORTED AN UNUSUAL ODOR IN COCKPIT WITH BLEED 1 LEAK MESSAGE. F/A REPORTED UNUSUAL NOISE IN CABIN. MX FOUND LOOSE DUCT AND SECURED THE DUCT TO HEAT EXCHANGER WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20140306006Flashlight · inoperativeFLIGHT ATTENDANT FWD FLASHLIGHT INOPERATIVE. REPLACED FWD FLIGHT ATTENDANT FLASHLIGHT, OPERATIONS CHECKED NORMAL IAW AMM 33-51-01.SDR SIMA20140306005Proximity Sensor · failedLG AIR, GND FAIL MESSAGE ON EICAS AFTER GEAR RETRACTION. R & R RT MLG WOW NR 1 SWITCH & LT MLG WOW NR 1 SWITCH IAW AMM 32-63-01. ADJUSTED THE TARGET ON LT MLG WOW NR 2 SWITCH IAW AMM 32-63-05. OPERATIONS CHECKED GOOD IAW AMM 32-63-00.SDR SIMA20140306002Acm · seizedA LITTLE SMOKE IN COCKPIT AFTER ENG NR 1 WAS STARTED 30 SEC LATER PACK NR 1 OVERHEAT MSG. FOUND NR 1 ACM SEIZED. R & R NR 1 ACM IAW AMM 21-51-03, OPERATIONS CHECKED GOOD AT THIS TIME. PERFORMED ETN EM 72-034 ENG ODOR EVENT SUPPLEMENT, NO DEFECTS NOTED AT THSDR ASOA20140306049Bleed Valve · stuckENROUTE, RECEIVED AN EICAS MESSAGE FOR ANTI-ICE INOPERATIVE. WING AND STAB ANTI-ICE FAIL. ACFT DIVERTED TO MAINTENANCE R & R THE NR 1 ENGINE BLEED VALVE IAW AMM 36-11-05, IPC REF IPC 36-11-05, FIGURE 01A, OPS CHECK GOOD AND WAS RELEASED BACK TO SERVICE.SDR SIMA20140306001Roller · lack of lubeFLIGHT ATTENDANT SAID MAIN CABIN DOOR STICKS & HARD TO OPEN. LUBRICATED ROLLERS IAW SMP, DOOR OPERATED NORMALLY.SDR SIMA20140305041Bracket · crackedRIGHT OVERWING PANEL LOWER BRACKET NR 2 IS CRACKED. RT OVERWING PANEL LOWER BRACKET NR 2 CRACKED HAS BEEN REMOVED & REPLACED WITH SERVICEABLE NR 2 BRACKET IAW ETN-EM-53-142.SDR SIMA20140305040Bracket · crackedLEFT OVERWING PANEL LOWER BRACKET NR 2 IS CRACKED. LT OVERWING PANEL LOWER BRACKET NR 2 CRACKED HAS BEEN REMOVED & INSTALLED SERVICEABLE LT NR 2 LOWER BRACKET IAW ETN-EM-53-142.SDR SIMA20140305034Light · crackedLEFT NR 7 EMERGENCY LIGHT STRIP IS CRACKED. R & R LT NR 7 EMERGENCY LIGHT STRIP IAW AMM 33-50-12 SEE BOW 150877 FOR OPERATIONAL CHECK.SDR SIMA20140305033Light · crackedLEFT NR 1 EMERGENCY LIGHT STRIP IS CRACKED. REMOVED & ACQUIRED LT NR 1 EMERGENCY LIGHT STRIP SEE BOW 150844 FOR INSTALLATION IAW AMM 33-50-12.SDR SIMA20140305032Support Bracket · crackedRIGHT ENG STARTER CONTROL VLV OTBD SUPPORT BRACKET CRACKED. R & R RT ENG STARTER CONTROL VLV OTBD SUPPORT BRACKET IAW AMM 80-10-02.SDR SIMA20140305031Fitting · crackedSHEAR CLIP CRACKED ON FRAME 26 BETWEEN STRINGERS 15R - 16R. R & R SHEAR CLIP AT FRAME 26, BETWEEN STRINGER 15R & 16R IAW SRM 51-40-02.SDR SIMA20140305030Fitting · crackedSHEAR CLIP CRACKED ON FRAME 24 BETWEEN STRINGERS 15R - 16R. R & R SHEAR CLIP ON FRAME 24, BETWEEN STRINGER 15R & 16R IAW SRM 51-40-02.SDR SIMA20140305029Seat Track · corrodedCENTER BEAM NR 1 SEAT TRACK IS CORRODED. R & R CTR BEAM NR 1 SEAT TRACK IAW AMM 53-01-06.SDR SIMA20140305028Firewall · crackedAPU FIREWALL CRACKED ON RT SIDE AT 3 O'CLOCK POSITION, REPAIR IAW EO EM-53AD-1883 PART C. FABRICATED & INSTALLED FILLER & DOUBLER FOR CRACKED RIVET HOLES & CRACK THAT WAS PREVIOUSLY STOP DRILLED AT THE 3 O'CLOCK POSITION ON THE APU FIREWALL IAW AMM 53-32-13, SDR SIMA20140305027Wire · brokenLEFT NR 2 EMERGENCY LIGHT STRIP WIRE UNDER FLOOR IS BROKEN. REPAIRED LT NR 2 EMERGENCY LIGHT STRIP WIRE UNDER FLOOR IAW SWPM 20-21-00 STEP 5 & WM 20-00-03. REFER TO BOW 150877 FOR OPERATIONS CHECK.SDR SIMA20140305026Fitting · crackedFRAME 73 SHEAR CLIP BETWEEN STRINGER 8L & 10L CRACKED. R & R FRAME 73 SHEAR CLIP BETWEEN STRINGER 8L & 10L IAW SRM 53-31-04.SDR SIMA20140305025Support Bracket · crackedRIGHT OVERWING FAIRING UPPER ATTACHMENT FLANGE SUPPORT BRACKET BETWEEN FRAME 48 & 49 CRACKED. R & R RT OVERWING FAIRING UPPER ATTACHMENT FLANGE SUPPORT BRACKET BETWEEN FRAME 48 & 49 IAW SRM 51-40-02.SDR SIMA20140305024Structure · corrodedBAGGAGE DOOR LOWER NUTPLATE HOLES HAVE SURFACE CORROSION. REPAIRED BAGGAGE DOOR LOWER NUTPLATE HOLES IAW ERS-EM-5200-104.SDR SIMA20140305037Sill · corrodedRIGHT CARGO FLOOR SILL IS CORRODED FWD OF FRAME 61 & LAVATORY CARBON BEAM. R & R RT FLOOR SILL AT FRAME 61 IAW SRM 51-40-02.SDR SIMA20140305035Support Angle · crackedCARGO DOOR CUT OUT RAMP SUPPORT ANGLE AT FRAME 66 CRACKED. REMOVED & INSTALLED NEW CARGO DOOR CUT OUT RAMP SUPPORT ANGLE AT FRAME 66 IAW SRM 51-40-02.SDR SIMA20140305038Sill · corrodedLEFT CARGO FLOOR SILL IS CORRODED FWD OF FRAME 61 & LAVATORY CARBON BEAM. R & R LT CARGO FLOOR SILL FWD OF FRAME 61 IAW SRM 51-40-02.SDR SIMA20140305036Support · crackedCARGO UNDERFLOOR LT BLEED AIR TUBE SUPPORT BETWEEN FRAME 68 & 69 CRACKED. REMOVED & INSTALLED LT BLEED AIR TUBES UNDER & ABOVE BLEED AIR TUBE SUPPORT BETWEEN FRAME 66 & 69 IAW AMM 36-11-09, LEAK CHECKED GOOD.SDR SIMA20140305039Gusset · corrodedLAVATORY CTR BEAM GUSSET IS CORRODED AT CARBON CTR BEAM. R & R LAVATORY CTR BEAM GUSSET IAW SRM 51-40-02.SDR SIMA20140305022Skin · crackedFUSELAGE EXTERNAL SKIN CRACKED AROUND 1 FASTENER RT SIDE FRAME 79 BELOW VERTICAL STABILIZER. CUT OUT DAMAGED AREA TO 0.375" IAW ERS-EM-5300-319. INSTALLED REPAIR BUSHING ON EXTERNAL SKIN AT RT SIDE FRAME 79 BELOW VERTICAL STABILIZER IAW ERS-EM-5300-319.SDR SIMA20140305021Power Supply · inoperativeNUMEROUS INTERIOR EMERGENCY LIGHTS NOT FUNCTIONING. R & R BATTERY POWER SUPPLY 2 IAW AMM 33-50-04, OPERATIONS CHECKED GOOD.SDR SIMA20140305018Support · crackedLEFT OVERWING UPPER BRACKET AFT SUPPORT IS CRACKED. R & R LT OVERWING UPPER BRACKET AFT SUPPORT IAW SRM 51-40-02 & 51-20-03.SDR SIMA20140305020Door Frame · corrodedCARGO DOOR FWD FRAME HAS CORROSION AROUND SEVERAL NUTPLATE HOLES. CARGO DOOR FWD FRAME CORROSION AROUND SEVERAL NUTPLATE HOLES ACCEPTED IAW ERS-EM-5200-098.SDR SIMA20140305019Wire · exposedNR 6 EMERGENCY PROXIMITY LIGHT STRIP WIRES EXPOSED. R & R NR 6 EMERGENCY PROXIMITY LIGHT STRIP AS REQUIRED SEE BOW151123 FOR INSTALLATION OF EMERGENCY PROXIMITY LIGHT STRIPS.SDR SIMA20140305017Floor Support · corrodedCO-PILOTS RT FLOOR SUPPORT CORRODED AROUND YOKE MOUNTING BASE. BLENDED OUT CORROSION ON CO-PILOTS RT FLOOR SUPPORT AROUND YOKE MOUNTING BASE IAW CPM 51-14-00. MAPPED DAMAGE IAW AE ETN-GN-51-013R2. ACCEPTED AS IS IAW ERS-EM-5300-313.SDR SIMA20140305016Support · corrodedFWD RT PULLEY SUPPORT CORRODED BETWEEN FRAME 16 & FRAME 17 AT STRINGER 21R. R & R FWD RT PULLEY SUPPORT BETWEEN FRAME 16 & 17 & STRINGER 21L - 21R IAW SRM 51-40-02.SDR SIMA20140305015Connector · brokenEMERGENCY LIGHT STRIP AT SEAT 10A HAS A BROKEN CONNECTOR, AIRFRAME SIDE. INSTALLED CONNECTOR ON EMERGENCY LIGHT STRIP WIRE AT SEAT 10A IAW SWPM 20-21-00. SEE NRTC BOW151123 TASK NR 2 FOR OPERATIONAL CHECK.SDR SIMA20140305014Charger · inoperativeBATTERY CHARGER EMERGENCY LIGHT NOT OPERATING. REMOVED BATTERY CHARGER.
Back to Embraer EMB-145LR