SDR SIMA20130924003Controller · failedDURING CLIMBOUT, CABIN PRESSURE CLIMBED RAPIDLY. SWITCHED TO MANUAL PRESSURE MODE ACFT STILL DIDN`T PRESSURIZE. DECLARED EMERGENCY AND LANDED WITHOUT EVENT. FOUND DIGITAL PRESSURE CONTROLLER TO READ ERRATICALLY AND MANUAL BUTTON WOULD NOT STAY DEPRESSED. SDR SIMA20130923007Structure · dentedMAIN PAX DOOR DENTED 10 INCHES FROM AFT EDGE 15 INCHES FROM BOTTOM. PERFORMED PERMANENT REPAIR IAW EO EM-5200-329.SDR SIMA20130923009Structure · dentedMAIN PAX DOOR DENTED. PERFORMED PERMANENT REPAIR IAW EO EM-5200-329.SDR SIMA20130923008Light · crackedNR 1 EMERGENCY LIGHT CRACKED. R & R FLOOR EMERGENCY LIGHT IAW AMM 33-50-12.SDR SIMA20130923010Wire · brokenNR 5 EMERGENCY LIGHT HAS A BROKEN WIRE. NEW EMERGENCY LIGHT INSTALLED IAW AMM 33-50-12.SDR SIMA20130923006Connector · missingAFT EMERGENCY LIGHT UNDERFLOOR WIRING IS MISSING A CONNECTOR. REPLACED BOTH EMERGENCY LIGHT CONNECTORS IAW SWPM 20-50-00.SDR SIMA20130923005Wire · brokenEMERGENCY LIGHT HAS A BROKEN WIRE. R & R FLOOR EMERGENCY LIGHT IAW AMM 33-50-12.SDR CHQA20130923356Frame · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE CARGO DOOR CUT OUT LATERAL L SHAPE ON FRAME 65. THE FRAME WAS REPAIRED IAW SRM 53-31-04 AND ETD 2013-145-044011.SDR CHQA20130923355Shear Tie · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR TIE AT FRAME 68 BETWEEN STRINGERS 7 - 8L. THE SHEAR TIE REPLACED IAW SRM 53-31-04.SDR CHQA20130923354Shear Tie · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR TIE AT FRAME 62, BETWEEN STRINGERS 7 - 9R. SHEAR TIE REPLACED IAW SRM 51-40-02.SDR ASOA20130923112Ballast · overheatedCREW REPORTED A BURNING ELECTRICAL ODOR LIKE A SOLDERING IRON OR HAIR CURLER, ABOVE SEAT 1A. DETERMINED THE ODOR TO BE COMING FROM THE SEAT 1A BALLAST. R & R CEILING LIGHT ASSY AT SEAT 1A WITH OPS CHECK GOOD.SDR SIMA20130923002Light · inoperativeRT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R RT OVERWING EMERGENCY LIGHT IAW AMM TASK 33-50-07-000-801-A AND 33-50-07-400-801-A. OPS CHECKED GOOD.SDR ASOA20130922110RFitting · brokenNR 1 ENGINE SHUTDOWN INFLIGHT AND DIVERTED. MX INSPECTED NR 1 ENGINE AND FOUND MAIN FUEL LINE ADAPTER FITTING BROKEN. MX R & R FUEL LINE FITTING, LEAK AND OPS CHECKED SUCCESSFUL. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20130925377Skin · dentedTHREE DENTS ON LT FUSELAGE SKIN. CUT-OUT DAMAGED SKIN AND INSTALLED TYPE B1 PATCH.SDR ASOA20130925376Skin · dentedTHREE DENTS ON LT FUSELAGE. CUT-OUT DAMAGED SKIN AND INSTALLED TYPE B1 PATCH.SDR SIMA20130922002Handle · malfunctionedF/A REPORTS MAIN DOOR HANDLE ROTATES TO CLOSED POSITION WHEN DOOR ABOUT HALF OF THE WAY TO FULL OPEN POSITION. LUBRICATED DOOR HANDLE MECHANISM. NO DEFECTS NOTED.SDR SIMA20130921003Lamp · inoperativeEMERGENCY LIGHT INOPERATIVE AT MAIN DOOR. R & R LAMP IAW AMM TASK 33-50-06-000-801-A AND 33-50-06-400-801-A. OPS CHECKED GOOD.SDR SIMA20130920011Mount · crackedCRACK ON LT FWD LOWER, FWD ENGINE YOKE INBD SIDE UPPER OTBD RADIUS. PERFORMED REPAIR IAW AEA EO EM-54MR-386.SDR SIMA2013093000011Frame · corrodedDURING HMBV INSPECTION, FOUND FRAME 65 ZEE FRAME CORRODED AROUND LOWER NUTPLATE HOLE ON LT SIDE. ACFT REMOVED FROM SERVICE. PERFORMED PERMANENT REPAIR ON FRAME 65 IAW EO-EM-53MR-2199.SDR SIMA20130920008Flashlight Assy · brokenCAPTAIN`S FLASHLIGHT BROKEN. R & R FLASHLIGHT IAW AMM 33-50-16.SDR SIMA20130920007Bulb · inoperativeRIGHT OVERWING AFT EMERGENCY LIGHT INOPERATIVE. R & R BULB IAW AMM 33-50-07, OPS CHECKED GOOD.SDR SIMA20130920006Flashlight Assy · inoperativeCAPTAIN`S FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT IAW AMM 33-50-16. OPS CHECKED GOOD.SDR SIMA20130920004Engine · odorTHE CREW REPORTED THAT DURING THE TAKEOFF ROLL THE NOTICED A BURNING ODOR IN THE COCKPIT. THE CREW ABORTED THE TAKEOFF. CONFIRMED ODOR IN CABIN. THE ACFT WAS REMOVED FROM SERVICE. R & R THE LT ENGINE IAW WC 71-000-00. OPS AND LEAK CHECKED GOOD IAW MM 72-0SDR SIMA20130920002Unknown · odorTHE CREW REPORTED A BURNING ODOR ON DESCENT THROUGH FT 280 AND AGAIN AROUND FT 180. THE ACFT LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. COMPLIED WITH ETN EM-72-034R4. NO ODOR NOTED AT THIS TIME. THE ACFT WAS RETURNED TO SERVICE.SDR SIMA20130920001Charger · inoperativeLT FWD EXTERNAL EMERGENCY LIGHT INOPERATIVE. TROUBLESHOT DOWN TO NR 1 BACK-UP BATTERY SUPPLY CHARGER. R & R BACKUP BATTERY CHARGER IAW AMM 33-50-04. OPS CHECK GOOD.SDR ASOA20130919111Battery Pack · inoperativeDURING MX INSPECTION, AFT CABIN FLASHLIGHT FOUND INOPERATIVE. MX R & R FLASHLIGHT BATTERY. OPS CHECKED GOOD. ACFT APPROVED FOR RETURN TO SERVICE.SDR RAIA201309190001Bulb · inoperativeRIGHT AFT WING/FUSELAGE FAIRING EXTERIOR FLOOD LIGHT INOPERATIVE. MX REPLACED RIGHT AFT WING/FUSELAGE FAIRING LIGHT AND OPS CHECK GOOD.SDR SIMA20130919002Pressure Switch · inoperativeAT FL370, RUDDER SYS 1-2 INOPERATIVE ON EICAS AS WELL AS HYD QTY 1 LOW AUTO PILOT DISENGAGE AND WEREN`T ABLE TO RE-ENGAGE. HYD QTY 1 BECAME NORMAL WHEN GEAR EXTENDED. AFTER LANDING ONLY RUDDER SYS 2 INOPERATIVE INDICATED ON EICAS. R & R RUDDER NR 1 PRESSURSDR SIMA20130919006Battery · inoperativeAFT ISLE ROW EMERGENCY LIGHT INOPERATIVE. R & R NR 4 EMERGENCY BATTERY AND CHARGER IAW AE WC 33-700-19. PERFORMED EMERGENCY LIGHTING SYS, OPS CHECK IAW AE WC 33-700-17. OPS CHECKED GOOD. NO DEFECTS NOTED.SDR SIMA20130919005Switch · brokenF/O FLASHLIGHT HAS A BROKEN SWITCH. R & R F/O FLASHLIGHT AND BATTERY IAW AMM TASK 33-50-16-000-801-A AND TASK 33-50-16-400-801-A. OPS CHECKED NORMAL.SDR SIMA20130919004Unknown · odorFAINT FUEL ODOR IN COCKPIT WHEN APU BLEEDS ARE TURNED ON. PERFORMED ENGINE RUN IAW AMM 71-00-01, PERFORMED ENGINE ODOR EVENT TROBLESHOOTING IAW ETN EM-72-034 R4. NO ODORS DETECTED.SDR ASOA20130919373Skin · dentedDURING C-CHECK INSPECTION, FOUND EXTERIOR SKIN BETWEEN FRAMES 19 AND 20, STR 11-12L CREASED. MX CUTOUT AND REMOVED THE CREASED AREA. FABRICATED A NEW PART IAW EC 5320-01842 AND INSTALL NEW PART.SDR SIMA20130919001Spar · crackedRT WING SPAR CRACKED AT HARNESS CUTOUT BETWEEN FSA 1 AND GROUND SPOILER ACTUATOR. REPAIRED RT WING SPAR 3 CRACK IAW AEA EO EM-57MR-709.SDR SIMA20130918009Frame · crackedFRAME 4 IS CRACKED NEAR TO THE STRINGER, DUE TO BIRD STRIKE. REPAIRED FRAME 4 IAW EO EM-53MR-2206.SDR CHQA20130918351Door Frame · corrodedDURING INSPECTION, SERVICE DOOR LOWER FRAME WAS FOUND TO BE CORRODED. THE FRAME WAS REPAIRED IAW SRM 51-10-03 AND ETD 2013-145-042010.SDR CHQA20130918350Floor Support · corrodedDURING INSPECTION, CORROSION WAS FOUND IN THE REPAIR DOUBLER AT LEFT OMEGA BEAM AT FRAME 20. MX REPLACED THE REPAIR DOUBLER IAW SRM 51-40-02.SDR SIMA20130918006Light · inoperativeSERVICE DOOR UPPER EXIT LIGHT INOPERATIVE. R & R SERVICE DOOR UPPER EXIT LIGHT ASSY IAW AMM 33-50-14. OPS CHECKED GOOD IAW AMM 33-50-00-700-801-A.SDR SIMA20130918005Wire · looseSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. FOUND WIRE PULLED OUT OF END OF CONNECTOR AT FIRST DISCONNECT FROM LIGHT ASSY. R & R WIRE SOCKED AND CONNECTOR IAW WM CHAPTER 20-50-01, OPS CHECKED GOOD.SDR SIMA20130918004Roller · lack of lubeMAIN CABIN ENTRY DOOR IS HARD TO OPEN. F/O FOUND IT HARD TO OPEN ALSO. PERFORMED LUBRICATION ON ROLLERS AND ACTUATING AND LOCKING MECHANISM ON MAIN DOOR IAW AMM 52-11-00.SDR SIMA20130917013Bulb · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. R & R BULB IAW AMM 33-50-05, OPS CHECKED GOOD.SDR SIMA20130917012Spar · crackedLT WING SPAR III CRACKED. REPAIRED LT SPAR III CRACK IAW EO EM-57MR-711. FOUND DURING EO EM-5700-662, ACCOMPLISHMENT.SDR ASOA20130917109Light · inoperativeDURING MX INSPECTION THE AISLE FLOOR EMERGENCY LIGHT AT ROW 16 WAS DISCOVERED INOPERATIVE. MX R & R LIGHT, OPS CHECKED SUCCESSFUL. ACFT APPROVED FOR RETURN TO SERVICE.SDR SIMA20130917006Light · inoperativeNR 4 FROM AFT FLOOR PROXIMITY LIGHT STRIP INOPERATIVE. R & R FLOOR PROXIMITY LIGHTSTRIP, NR 4 FROM AFT, IAW AMM 33-50-12. OPS CHECKED GOOD.SDR SIMA20130917005Door · dirtyF/A REPORTS MAIN CABIN DOOR IS DIFFICULT TO OPERATE. CLEANED, LUBED AND PERFORMED OPS CHECK OF MAIN DOOR IAW AMM 52-10-01. CLEANED AND LUBED DOOR ROLLERS, REQUIRED 30LBS ON FISH SCALE TO OPEN.SDR SIMA20130917008Radio Altimeter · malfunctionedAT APPROXIMATELY 300 FT AURAL WARNING TO LOW GEAR, GO AROUND RETURN. EMERGENCY GEAR, EXT 3 GREEN INDICATION. R & R RADIO ALTIMETER UNIT IAW AMM 34-31-00. PERFORMED OPS CHECK AND NO DEFECTS FOUND.SDR SIMA20130917004Skin · corrodedEXTERNAL SKIN CORRODED BETWEEN FRAMES 13-14, STR 20L-19R. REPAIRED IAW AEA EO EM-53MR-2198.SDR SIMA20130917003Cradle · brokenF/A FLASHLIGHT CRADLE IS BROKEN. R & R F/A FLASHLIGHT CRADLE IAW AMM 33-50-165, OPS CHECKED GOOD.SDR SIMA20130917002Cradle · brokenFLASHLIGHT CRADLE ABOVE F/A SEAT IS BROKEN. R & R FLASHLIGHT ASSEMBLY ABOVE F/A SEAT IAW AMM 33-50-16.SDR SIMA20130916009Battery · inoperativeAFT TWO FLOOR PROXIMITY LIGHTS INOPERATIVE. R & R NR 4 EMERGENCY POWER SUPPLY IAW AMM 33-50-04. OPS CHECKED GOOD.SDR SIMA20130916006Cart · odorF/A REPORTS THAT ONE OF THE GALLEY CARTS SMELLS LIKE A DEAD ANIMAL. CLEANED INSIDE OF BOTH GALLEY CARTS. NO DEFECTS OR ODORS NOTED. OK FOR SERVICE.
Back to Embraer EMB-145LR