Embraer EMB-145LR

Service difficulty reports · 36,799

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SIMA20130916005Control Panel · smokeSMOKE SEEN COMING FROM STALL PROTECTION TEST PANEL. SMOKE AND ELECTRIC ODOR PRESENT IN COCKPIT. SMOKE ALSO SEEN COMING FROM STALL PROTECTION TEST BUTTON. R & R STALL PROTECTION PANEL IAW AMM 20-13-10. OPS CHECKED GOOD IAW AMM 27-36-00.Sep 16, 2013 · N646AE · Emb EMB145LR · Stall Warning SystemSDR SIMA20130916004Door · lack of lubeTHE MAIN CABIN DOOR IS HARD OPEN. LUBRICATED MAIN CABIN CABIN DOOR FRAME ROLLERS IAW AMM 53-21-02. TESTED SATISFACTORY.Sep 16, 2013 · N642AE · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA20130916003Flashlight Assy · inoperativeF/O FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT IAW AMM 33-50-16. OPS CHECKED GOOD.Sep 16, 2013 · N631AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20130916002Shear Tie · corrodedFR 68L SHAPE CORROSION ON LOWER PORTION ABOVE CARGO DOOR SILL. REPAIRED FR 68 SHEARCLIP IAW AEA EO EM-53MR-1129, PART B.Sep 16, 2013 · N611AE · Emb EMB145LR · Fuselage Internal Mounting StructureSDR ASOA20130916235Battery Pack · inoperativeLOWER LT EMERGENCY LIGHT IN GALLEY INOPERATIVE. MX R & R NR 2 EMERGENCY LIGHT BATTERY IAW AMM 33-50-04, ACFT RETURNED TO SERVICE.Sep 16, 2013 · N15980 · Emb EMB145LR · Emergency LightingSDR SIMA20130916001Cradle · brokenF/O FLASHLIGHT HOLDER BROKEN. R & R F/O FLASHLIGHT HOLDER IAW AMM 33-50-16; OPS CK GOOD.Sep 16, 2013 · N685AE · Emb EMB145LR · Emergency EquipmentSDR CHQA20130915342Connector · looseDURING INSPECTION, THE LT OVERWING EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MX RESOLDERED A LOOSE CONNECTION, AFTER WHICH ALL OPS CHECKS WERE GOOD.Sep 15, 2013 · N293SK · Emb EMB145LR · Light System WiringSDR CHQA20130915341Wire · looseDURING INSPECTION, THE GALLEY AISLE CEILING PANEL EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MX RECONNECTED A LOOSE WIRE ON THE LIGHT AND ALL OPS CHECKS WERE GOOD.Sep 15, 2013 · N293SK · Emb EMB145LR · Light System WiringSDR SIMA20130915004Flashlight · missingFWD EMGERGENCY FLASHLIGHT MISSING. REPLACED FWD EMG FLASHLIGHT AS REQUIRED.Sep 15, 2013 · N906AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20130915003Lamp · inoperativeMAIN DOOR OVERHEAD EMERGENCY LIGHT INOPERATIVE. R & R MAIN DOOR OVERHEAD EMERGENCY LIGHT LAMP IAW AMM 33-50-06-000-801-A AND 33-50-06-400-801-A. OPS CHECKED GOOD.Sep 15, 2013 · N900AE · Emb EMB145LR · Emergency LightingSDR SIMA20130915002Lamp · inoperativeSERVICE DOOR OVERHEAD EMERGENCY LIGHT INOPERATIVE. R & R SERVICE FOOR OVERHEAD EMERGENCY LIGHT LAMP IAW AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECKED GOOD.Sep 15, 2013 · N638AE · Emb EMB145LR · Emergency LightingSDR SIMA20130915001Unknown · unknownTHE CREW REPORTED THEY WERE UNABLE TO ROTATE ON TAKEOFF ROLL WITH YOKE FULL AFT. HIGH SPEED ABORT PERFORMED. THE ACFT WAS REMOVED FROM SERVICE. ELEVATOR DEFLECTION CHECK COMPLIED WITH IAW 27-31-00 ALSO OPS CHECK OF AURAL WARNING UNIT IAW AMM 31-51-00. ELEVASep 15, 2013 · N616AE · Emb EMB145LR · Flight Control SystemSDR SIMA20130914003Light · malfunctionedEMERGENCY LIGHTS ON REAR HALF OF ACFT REMAIN ON AFTER POWER DOWN. COMPLIED WITH EMERGENCY LIGHT SYSTEM RESET. OPS CHECK OF EMERGENCY LIGHT SYSTEM PASSED IAW AMM 33-50-00-700-801-A.Sep 14, 2013 · N928AE · Emb EMB145LR · Emergency LightingSDR SIMA20130914002Cradle · brokenFLASHLIGHT ABOVE FWD F/A SEAT HOLDER BROKEN. R & R FWD F/A FLASHLIGHT HOLDER IAW MM 33-50-16, OPS CHECKED GOOD.Sep 14, 2013 · N634AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20130913015Wire · damagedEMERGENCY LIGHT STRIP WIRING EXTENDING FROM UNDERFLOOR AT POSITIONS 2,3,4,AND 6 DAMAGED. REPAIRED WIRING IAW SWPM 20-50-01.Sep 13, 2013 · N621AE · Emb EMB145LR · Light System WiringSDR SIMA20130913014Light · brokenRIGHT NR 1 EMERGENCY LIGHT STRIP BROKEN. R & R RT LIGHT STRIP IAW AMM 33-50-12.Sep 13, 2013 · N621AE · Emb EMB145LR · Emergency LightingSDR SIMA20130913013Wire · cutFWD EMERGENCY LIGHT WIRING CUT. REPAIRED WIRE IAW SWPM 20-50-01. OPS CHECKED.Sep 13, 2013 · N621AE · Emb EMB145LR · Light System WiringSDR SIMA20130913012Light · brokenRIGHT NR 3 EMERGENCY LIGHT STRIP BROKEN. REMOVED AND INSTALLED SERVICABLE EMERGENCY LIGHT IAW AMM 33-50-12.Sep 13, 2013 · N621AE · Emb EMB145LR · Emergency LightingSDR SIMA20130913011Profile · corrodedFRAME 65 LT PROFILE CORRODED AROUND CARGO DOOR SILL AREA. REPAIRED IAW EO EM-53MR-1129.Sep 13, 2013 · N621AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20130913010Lamp · inoperativeMAIN CABIN DOOR EMERGENCY LIGHT IN CEILING PANEL INOPERATIVE. R & R EMERGENCY LIGHT LAMP AT CEILING OF MAIN CABIN DOORWAY IAW AMM TASK 33-50-06-000-801-A AND 33-50-06-400-801-A. OPS CHECKED GOOD.Sep 13, 2013 · N677AE · Emb EMB145LR · Emergency LightingSDR SIMA20130913009Display · failedDURING APU START WITH GPU POWER, THE F/O MFD SCREEN WENT BLANK. THE MFD 2 CIRCUIT BREAKER POPPED WITH ODOR OF ELECTRICAL SMOKE. R & R F/O MFD UNIT, OPS CHECKED GOOD IAW AMM 34-22-02.Sep 13, 2013 · N663AR · Emb EMB145LR · Integrated Flight SystemSDR SIMA20130913006Proximity Sensor · inoperativeTHE CREW REPORTED JUST AFTER LEVELING AT FL 360 THEY HEARD & FELT A LOUD THUMP UNDER THE COCKPIT FLOORBOARD. THE ACFT DID NOT GIVE ANY AN INDICATION OF A MALFUNCTION , BUT THE CREW HEARD THE THUMP AGAIN. THE CREW DIVERTED SO THAT MX COULD INSPECT THE ACFT. Sep 13, 2013 · N647AE · Emb EMB145LR · Landing Gear Position and WarningSDR SIMA20130913005Sleeve · inoperativeTHE CREW REPORTED PACK NR 1 VALVE CLOSED DURING CLIMB, RESET IAW AOM V1, STAYED OK FOR 5 MINUTES THEN CLOSED AGAIN. THE CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. THE ACFT WAS REMOVED FROM SERVICE. R & R NR 210 AND NR 230 LT ACM SLEEVES IN REFR Sep 13, 2013 · N909AE · Emb EMB145LR · Flight Control SystemSDR SIMA20130913004Actuator · inoperativeTHE CREW REPORTED THAT AT FL 320 WITH AUTOPILOT ENGAGED, WE RECEIVED EICAS "AP ELEV MISTRIM". THE CREW DISCONNECTED THE AUTOPILOT AND SHORTLY AFTER RECEIVED EICAS "PTRIM MAIN INOP". THE CREW DECLARED AN EMERGENCY AND UTILIZED BACKUP PITCH TRIM FOR LANDING. TSep 13, 2013 · N622AE · Emb EMB145LR · Elevator Control SystemSDR SIMA20130913003Flashlight Assy · inoperativeF/O FLASHLIGHT INOPERATIVE. REPLACED F/O FLASHLIGHT IAW AMM 25-60-00. OPS CHECKED GOOD.Sep 13, 2013 · N663AR · Emb EMB145LR · Emergency EquipmentSDR SIMA20130913002Flashlight Assy · inoperativeELECTRICAL BURNING ODOR IN COCKPIT AND CABIN. R & R EMERGENCY FLASHLIGHT IN FLIGHT DECK, BEHIND CAPTAINS SEAT IAW AMM 33-50-16. OPS CHECKED GOOD.Sep 13, 2013 · N699AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20130913001Inverter · unserviceableRT UPPER EMERGENCY EXIT SIGN AT ROW 12 INOPERATIVE. R & R EMERGENCY LIGHT NR 5 INVERTER IAW MM 33-50-11. OPS CHECKED GOOD.Sep 13, 2013 · N658AE · Emb EMB145LR · Emergency LightingSDR SIMA20130912001Lamp · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R LAMP IAW AMM TASK 33-50-06-000-801-A AND 33-50-06-400-801-A. OPS CHECKED GOOD.Sep 12, 2013 · N654AE · Emb EMB145LR · Emergency LightingSDR SIMA20130911012Frame · gougedFRAME 70 BETWEEN STR 12-13R GOUGED. REPAIRED IAW AEA EO EM-53MR-2193.Sep 11, 2013 · N611AE · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20130911011Skin · crackedREAR ELECTRONICS DOOR 272DR SKIN CRACKED AROUND ANGLE RIVETS. REPAIRED IAW AEA EO EM-52MR-371.Sep 11, 2013 · N611AE · Emb EMB145LR · Electrical/Electronic Compartment DoorsSDR SIMA20130911010Battery · inoperativeFLOOR EMERGENCY PROXIMITY LIGHTS 2 AND 3 INOPERATIVE. R & R BATTERY PACK AND CHARGER IAW AMM 33-50-01. OPS CHECKED GOOD.Sep 11, 2013 · N622AE · Emb EMB145LR · Emergency LightingSDR SIMA20130911009Flashlight Assy · intermittentF/O'S FLASHLIGHT IS INTERMITTENT DURING USE. CONNECTED F/O'S FLASHLIGHT BATTERY OPS CHECKED GOOD IAW AMM 33-51-01Sep 11, 2013 · N621AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20130911005Fitting · damagedLT AILERON PCA FITTING DAMAGED. REMOVED AND INSTALL PCA FITTING IAW EO EM-27MR-112.Sep 11, 2013 · N611AE · Emb EMB145LR · AileronsSDR SIMA20130911003Cradle · brokenCAPTAIN FLASHLIGHT HOLDER BROKEN. R & R CAPTAINS FLASHLIGHT ASSY IAW AMM 33-50-16. OPS CHECK GOOD.Sep 11, 2013 · N922AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20130911001Cradle · brokenCOCKPIT FLASHLIGHT MOUNT IS BROKEN. R & R FLASHLIGHT BASE IAW CMM 25 60 11. OPS CHECK GOOD.Sep 11, 2013 · N612AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20130910010Flashlight Assy · inoperativeCO-PILOTS EMERGENCY FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT ASSY IAW AMM 33-50-16. OPS TESTED GOOD.Sep 10, 2013 · N623AE · Emb EMB145LR · Emergency EquipmentSDR SIMA20130910013Light · wrong partNR 8 EMERGENCY LIGHT STRIP INCORRECT PN INSTALLED. R & R NR 8 EMERGENCY LIGHT STRIP IAW EMB 145, AMM 33-50-12. OPS CHECK GOOD.Sep 10, 2013 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20130910011Wire · brokenLT NR 4 EMERGENCY LIGHT HAS A BROKEN WIRE. REPAIRED BROKEN WIRE ON LT NR 4 EMERGENCY LIGHT STRIP HARNESS, AIRCRAFT SIDE IAW SWPM 20-21-00. BOW139255 FOR OPS CHECK, TURN OVER FOR DETAILS.Sep 10, 2013 · N623AE · Emb EMB145LR · Light System WiringSDR SIMA20130910014Connector · brokenNR 1 AND NR 4 PROXIMITY LIGHT STRIPS HAVE BROKEN CONNECTORS. R & R CONNECTORS IAW WM 90-10-02, AND SWPM 20-00-03.Sep 10, 2013 · N623AE · Emb EMB145LR · Light System WiringSDR SIMA20130910015Battery · inoperativeEMERGENCY LIGHT AT MAIN ENTRANCE CEILING PANEL (233 ALC) INOPERATIVE. R & R BATTERY POWER SUPPLY NR 1 IAW AMM 33-50-04. OPS TESTED GOOD.Sep 10, 2013 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20130910012Skin · corrodedINNER FUSELAGE SKIN CORRODED BETWEEN FRAMES 9-10 AND S20-21L. REPAIRED IAW EO-EM-53MR-2211.Sep 10, 2013 · N623AE · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20130910009Light · brokenEMERGENCY LIGHT NR 7 BROKEN. R & R IAW AMM 33-50-12, STEPS 2.I. AND 3.I.(1) AND (3).Sep 10, 2013 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20130910007Charger · inoperativeBATTERY POWER SUPPLY INOPERATIVE.Sep 10, 2013 · N623AE · Emb EMB145LR · Emergency LightingSDR SIMA20130910008Cradle · inoperativeREMOVE BATTERY HOLDER ASSY, REMOVE BATTERY HOLDER ASSY.Sep 10, 2013 · N623AE · Emb EMB145LR · Emergency LightingSDR ASOA20130910106Unknown · odorA BURNING ODOR COMING FROM THE COFFEEMAKER WAS REPORTED. MX INSPECTED COFFEE BREWERS WIRING, TERMINALS IAW EA2530-01035 WITH NO DEFECTS NOTED. ALSO, PERFORMED OPS CHECK, TEST OF COFFEE BREWERS 1 AND 2 AND COULD NOT DUPLICATE FAULT. BREWERS OPS CHECK GOOD. Sep 10, 2013 · N18557 · Emb EMB145LR · Buffet/GalleysSDR ASOA20130910105Light · inoperativeDURING SCHEDULED MX INSPECTION, THE ROWS 10 & 11 EMERGENCY LIGHT STRIP WAS FOUND INOPERATIVE. MX R & R THE LIGHT STRIP AT ROW 10 & 11 WITH OPS CHECK SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.Sep 10, 2013 · N14542 · Emb EMB145LR · Emergency LightingSDR SIMA20130910006Skin · tornAFT RT EDGE OF RUDDER 1 CRACKED/ TORN. CUT-OUT DAMAGE, FABRICATE AND INSTALLED REPAIR DOUBLER, FILLER IAW EO-EM-53MR-438.Sep 10, 2013 · N622AE · Emb EMB145LR · Rudder, Plate/SkinSDR ASOA20130909104Light · inoperativeDURING SCHEDULED MX INSPECTION THE NR 1 FLOOR PROXIMITY EMERGENCY LIGHT STRIP WAS FOUND TO BE INOPERATIVE. MX R & R THE NR 1 FLOOR PROXIMITY LIGHT STRIP WITH OPS CHECK SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.Sep 9, 2013 · N13975 · Emb EMB145LR · Emergency LightingSDR SIMA20130909003Sill · corrodedDURING HMBV INSPECTION, FOUND CARGO DOOR SILL CORRODED BETWEEN FRAMES 65-68. R & R CARGO DOOR SILL IAW SRM 51-40-02.Sep 9, 2013 · N629AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20130909005Skin · corrodedINNER FUSELAGE SKIN IS CORRODED BETWEEN S21L AND 21R AT FR 67. REPAIRED SKIN IAW EO EM-53MR-2189.Sep 9, 2013 · N629AE · Emb EMB145LR · Fuselage Main, Plate/Skin
Back to Embraer EMB-145LR