Embraer EMB-145LR
Service difficulty reports · 36,799
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20130807006Flashlight · inoperativeCAPTAIN`S EMERGENCY FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT IAW AMM 33-50-16. OPS CHECKED GOOD.SDR SIMA20130807004Lock · lack of lubeMAIN DOOR DIFFICULT TO OPEN. LUBRICATED MAIN DOOR LOCK MECHANISM IAW AMM 52-18-00.SDR SIMA20130807005Lamp · inoperativeF/A OVERHEAD EMERGENCY LIGHT INOPERATIVE. R & R EMERGENCY LAMP IAW AMM 33-50-06-000-801-A AND 33-50-06-400-801-A.SDR SIMA20130807002Roller · lack of lubeMAIN CABIN DOOR HARD TO OPEN AND CLOSE. INSPECTED MAIN CABIN DOOR AND FOUND ALL 4 GUIDE ROLLERS VERY DRY CLEANED AND LUBRICATED ROLLER OPS. CK OF OPENING AND CLOSING MECHANISM WORKING NORMAL IAW AMM 52-10-00.SDR SIMA20130807003Door · lack of lubeMAIN CABIN DOOR WILL NOT OPEN FROM INSIDE. SERVICED AND LUBRICATION OF MAIN CABIN DOOR IAW AMM 52-11-00. OPS CHECKED GOOD.SDR SIMA20130806002Battery Pack · dischargedWHEN GPU POWER WAS REMOVED FROM ACFT, EMERGENCY LIGHTS ILLUMINATED WITH EMERGENCY LIGHT SWITCH IN OFF POSITION. RECHARGED EMERGENCY BATTERIES IAW CMM 25-60-03 FOR 3.5 HRS AND OPS CHECKED EMERGENCY LIGHTS IAW AMM 33-50-00. OPS CHECKED GOOD NO DEFECTS NOTED.SDR ASOA20130806350TBearing · wornACFT LT AND RT HORIZONTAL STABILIZER SPHERICAL BEARINGS HAD PLAY IN THE HOUSING. MX REAMED BOTH HOUSINGS AND REPAIRED AND INSTALLED SPHERICAL BEARINGS IAW SRM 55-30-02. COMPLIED WITH BACKLASHES IAW AMM 27-40-00; ALL WORK ACCOMPLISHED AND WAS RELEASED TO SERSDR CHQA20130805313Door Frame · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE BOTTOM OF THE PASSENGER DOOR FRAME. THE FRAME WAS REPLACED IAW SRM 51-20-03 AND 51-40-02.SDR ASOA20130805090Flapper Valve · leakingAFTER TAKEOFF, FUEL REPORTED TO BE VENTING FROM LT WING. CREW PEFORMED UNEVENTFUL AIR TURN BACK. R & R LT WING FLAPPER VALVE AND LEAK CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA2013080500006Fan · failedCREW REPORTED ODOR IN COCKPIT & FORWARD CABIN. ODOR IS SIMILAR TO HOT ANTI-FREEZE FLUID. R & R FWD LT AVIONICS FANS IAW AMM 21-26-02. OPS CHECKED GOOD. NO ODORS NOTED.SDR SIMA20130805005Battery Pack · inoperativeFLOOR EMERGENCY LIGHT FROM SEAT 8 TO 10 INOPERATIVE. R & R NR 3 EPSU BATTERY AND CHARGER OPS CHECKED GOOD IAW AE WC 33-700-19.SDR SIMA20130805004Manifold · inoperativeAFTER TAKEOFF AT ABOUT 600 AGL, HYD SYS 1 LOW QTY, HYD 1 SYS LOW PRESSURE HYD 1 SYS 1 FAIL, RUDDER SYS 1 INOPERATIVE AND AILERON 1 SYS 1 PRESSURE DROPPED TO ZERO, SYS 1 QTY DROPPED TO ZERO. DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE. LANDED WITHOUT INSDR SIMA20130805002Engine · shutdownWHILE AWAITING GPU CONNECTION WITH NR 2 ENGINE RUNNING, ENGINE SHUTDOWN ON ITS OWN BOTH FUEL PUMPS WERE OFF. PERFORMED A FUEL LOW PRESSURE WARNING TEST ALSO PERFORMED ENGINE RUN AND SHUTDOWN IAW GROUND HANDLING CHECKLIST SYS FOUND TO BE OPERATING NORMAL IAW ASDR ASOA20130805344Lamp · inoperativeRT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R LIGHT BULB. OPS CK GOOD.SDR SIMA20130805006Structure · crackedDURING HMBV INSP, FOUND A CRACK ON INNER UPPER SURFACE OF DOOR 272DR AT MOUNTING ANGLE. ACFT WAS REMOVED FROM SERVICE. CUT OUT DAMAGE, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW EO EM-53MR-364. ACFT RETURNED TO SERVICE.SDR ASOA20130803089Smoke Detector · false indicationCREW REPORTED A LAVATORY SMOKE INDICATION ON EICAS TWICE DURING FLIGHT. CREW PERFORMED QRH AND CONTINUED TO DESTINATION. MX INSPECTED AND FOUND NO EVIDENCE OF LAVATORY FIRE. MX PERFORMED OPS CHECK OF LAVATORY SMOKE SYS, SUCCESSFUL. ACFT WAS APPROVED FOR RETSDR CHQA20130803308Battery Pack · inoperativeDURING INSPECTION, THE LT AND RT EXTERNAL OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MX REPLACED THE NR 4 EMERGENCY LIGHT BATTERY. OP CHECKED GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA20130803002Bulb · inoperativeGALLEY OVERHEAD EMERGENCY LIGHT INOPERATIVE. GALLEY OVERHEAD EMERGENCY LIGHT BULB IAW AMM 33-50-09, OPS CHECKED GOOD IAW 33-50-00.SDR SIMA20130803001Sleeve · failedTHE CREW REPORTED A MASTER CAUTION BLEED LEAK IN NR 1 ENGINE. DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE. ACFT REMOVED FROM SERVICE. R & R THE LT DTCV AFT SLEEVES AND BLEED SYS 1 LEAK CHECK, NO LEAKS NOTED AMM 21-60-01 AND 36-11-09. ACFT RETURNED TSDR SIMA20130802001Flashlight · inoperativeF/O'S FLASHLIGHT IS INOPERATIVE. R & R FLASHLIGHT IAW AMM 25-60-00, OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR CHQA20130802312Frame · bentDURING INSPECTION, FRAME 72 WAS BENT BETWEEN STRINGERS 14-15R. FRAME REPAIRED IAW SRM 53-00-04.SDR CHQA20130802311Shear Tie · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIPS AT FRAME 65 BETWEEN STINGERS 7L AND 9L. MX REPLACED THE SHEAR CLIPS IAW SRM 51-40-02.SDR CHQA20130802310Shear Tie · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIPS AT FRAME 65 BETWEEN STINGERS 7L AND 9L. MX REPLACED THE SHEAR CLIPS IAW SRM 51-40-02.SDR CHQA20130802307Light · inoperativeDURING INSPECTION, THE LT AFT OVERWING EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MX REPLACED THE LT HOUSING ASSY AND OPS CHECKED GOOD.SDR ASOA20130802088Flapper Valve · leakingCREW REPORTED FUEL LEAKING FROM THE RT WING AFTER TAKEOFF ALONG WITH FUEL IMBALANCE. CREW PERFORMED UNEVENFUL AIR RETURN. MX R & R THE RT WING FLAPPER VALVE WITH LEAK CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA20130802306Light · inoperativeDURING INSPECTION, EMERGENCY LIGHT AT ROW EIGHT WAS FOUND TO BE INOPERATIVE. MX REPLACED THE LIGHT AND OPS CHECKED GOOD.SDR SIMA20130802004Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R MAIN DOOR EMERGENCY LIGHT IAW AMM TASK 33-50-06-000-801-A, 33-50-06-400-801-A.. OPS CHECKED GOOD.SDR SIMA20130802008Battery Pack · inoperativeBATTERY PACK NR 4 INOPERATIVE. R & R NR 4 BATTERY PACK IAW AMM 33-50-04. OPS CHECKED GOOD.SDR SIMA20130802006Battery Pack · inoperativeNR 1 BATTERY PACK, INOPERATIVE. R & R NR 2 BATTREY PACK IAW AMM 33-50-04, OPS CHECKED GOOD.SDR SIMA20130802007Battery · inoperativeNR 1 BATTERY PACK INOPERATIVE. R & R NR 3 BATTREY PACK IAW AMM 33-50-04. OPS CHECKED GOOD.SDR CHQA20130802301Smoke Detector · dirtyCREW REPORTED THAT THEY RECEIVED A BAGGAGE COMPARTMENT SMOKE WARNING MESSAGE IN FLIGHT. THE CREW RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MX CLEANED BOTH BAGGAGE COMPARTMENT SMOKE DETECTORS. OPS CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR CHQA20130802300Smoke Detector · dirtyCREW REPORTED THAT THEY RECEIVED A BAGGAGE COMPARTMENT SMOKE WARNING MESSAGE IN FLIGHT. RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MX CLEANED BOTH BAGGAGE COMPARTMENT SMOKE DETECTORS. OPS CHECKED GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA20130802003Flashlight Assy · inoperativeTHE CREW REPORTED THE FWD FLASHLIGHT IN CABIN WAS INOPERATIVE. ACFT OK FOR SERVICE. R & R FLASHLIGHT AND CRADLE ASSY. OPS CHECKED GOOD IAW AMM 33-50-16. ACFT RETURNED TO SERVICE.SDR SIMA20130805001Wire · brokenDURING CRUISE, FL 280, EXPERIENCED A SYS 2 BLEED LEAKING WARNING. APPLIED AOM VOL 1 PROCEDURES AND WERE UNABLE TO RESOLVE ANOMALY. DIVERTED. A CHECKLIST DRIVEN "PRECAUTIONARY" ENGINE SHUTDOWN WAS APPLIED AND AN EMERGENCY WAS DECLARED. LANDED WITHOUT INCIDSDR SIMA20130801009Skin · corrodedINNER FUSELAGE SKIN IS CORRODED BETWEEN STRINGERS 21L AND 21R AT FRAME 67. REPAIRED FUSELAGE SKIN IAW EO EM-53MR-2189.SDR SIMA20130801007Plate · corrodedPLATE IN BELLY OF ACFT FWD OF FRAME 67 BETWEEN STR'S 21L AND 20L IS CORRODED AROUND THE RIVETS. PLATE IN BELLY OF ACFT FWD OF FRAME 67 BETWEEN STR'S 21L AND 20L REMOVED REFER TO EO EM-53MR-2189, STEP 12 AND ETA EM-5300-3088.SDR SIMA20130801008Wire · misinstalledEMERGENCY LIGHT WIRING SEEMS TO BE IMPROPERLY CLAMPED AT FRAME 51. ROUTED WIRING IAW SWPM 20-21-00.SDR SIMA20130801006Flashlight · inoperativeTHE CREW REPORTED THE AFT F/A FLASHLIGHT WAS INOPERATIVE. ACFT OK FOR SERVICE. R & R THE AFT FLASHLIGHT ASSY. OPS CHECKED GOOD IAW 33-50-16. ACFT RETURNED TO SERVICE.SDR SIMA20130801005Display · odorCAPTAIN'S MFD WENT DARK AND STRONG ELECTRICAL ODOR. R & R CAPT'S MFD IAW MM 34-22-01. OPS CHECKED GOOD. NO ELECTRICAL ODOR.SDR SIMA20130801003Inverter · inoperativeEMERGENCY LIGHT ON AFT WALL OF GALLEY IS INOPERATIVE. R & R NR 3 EMERGENCY LIGHT INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD IAW AE W/C 33-700-17.SDR SIMA20130801004Light · inoperativeRAMP REPORTS EMERGENCY LIGHTS INOPERATIVE.SDR ASOA20130731086Bracket · unsecureMX REPORTED THE MAIN CABIN DOOR WOULD NOT OPEN. MX SECURED THE MAIN DOOR HANDLE BRACKET. OPS CHECK OF THE MAIN DOOR SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20130731008Support Beam · corrodedDURING HMBV INSPECTION, QC FOUND LAVATORY CENTER BEAM CORRODED AT FWD NUT PLATE HOLES. ACFT WAS REMOVED FROM SERVICE AND RETURNED TO SERVICE AFTER HMBV INSPECTION.SDR SIMA20130731005Roller · lack of lubeF/A REPORTS MAIN PAX DOOR HANDLE GET STUCK AND DOOR HARD TO CLOSE AND OPEN. LUBRICATED MAIN CABIN DOOR FRAME ROLLERS IAW AMM 52-18-00. TESTED SATISFACTORY.SDR SIMA20130731004Power Supply · inoperativeRT OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED NR 4 EPSU IAW AMM 33-50-04, OPS CHECKED GOOD.SDR SIMA20130731007Spar · crackedCRACK ON LT WING SPAR, STARTING ON MLG WIRE HARNESS ACCESS HOLE GOING UPWARDS TO 1 O'CLOCK, CRACK APROX 2.4". ACCOMPLISHED EDDY CURRENT INSP IAW ETN-EM-51-113. FOUNDED LINEAR INDICATION ON DISPLAY UNIT.SDR SIMA20130731001Cradle · crackedCAPTAIN`S FLASHLIGHT BASE IS CRACKED. R & R CAPTAIN'S FLASHLIGHT ASSY IAW AMM 33-50-16. OPS CHECKED GOOD.SDR SIMA20130730006Support Bracket · crackedPAX DOOR INNER HANDLE HOUSING SUPPORT BRACKET CRACKED. REPAIRED PAX DOOR INNER HANDLE HOUSING SUPPORT ASSY IAW EO EM-52MR-250.SDR SIMA20130730005Wire · brokenLT NR 6 FLOOR PROXIMITY LIGHT STRIP HAS A BROKEN WIRE. R & R LT NR 6 FLOOR PROXIMITY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20130730004Wire · brokenLEFT NR 2 FLOOR PROXIMITY LIGHT STRIP HAS A BROKEN WIRE. R & R LT NR 2 FLOOR PROXIMITY LIGHT STRIP IAW AMM 33-50-12.
Back to Embraer EMB-145LR