Embraer EMB-145LR
Service difficulty reports · 36,799
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20130814003Inverter · inoperativeOVERWING EXIT LOCATOR FWD SIDE INOPERATIVE. R & R EMERGENCY LIGHT INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD.SDR SIMA20130814007Light · inoperativeGALLEY EMERGENCY LIGHT ON CEILING PANEL INOPERATIVE. R & R EMERGENCY LIGHT IAW AMM 33-50-14; OPS CHECKED BAD.SDR SIMA20130814006Inverter · inoperativeNR 3 AC/DC INVERTER FOR EMERGENCY LIGHT IN GALLEY INOPERATIVE. R & R NR 3 INVERTER IAW AMM 33-50-11; OPS CHECKED GOOD.SDR SIMA20130814001Lamp · inoperativeEXTERNAL MAIN CABIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R LAMP IAW AMM TASKS 33-50-10-000-801-A/33-50-10-400-801-A. OPS CHECKED GOOD.SDR SIMA20130814005Light · looseEMERGENCY EXIT PANEL LIGHT INOPERATIVE. AT ROW 12 BC. RESECURED EMERGENCY EXIT PANEL LIGHT 12 BC IAW AMM 33-50-08 AND OPS TESTED IAW AMM 33-50-00. TESTED SATISFACTORY.SDR ASOA20130814203Mount · crackedDURING C-CHECK, NR 1 ENGINE FWD LOWER MOUNT CRACKED. MX R & R ENG NR 1 FWD LOWER YOKE FITTING IAW EC5450-01073. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130814202Stringer · corrodedC-CHECK, STRINGER 17R HAS CORROSION, LOCAL LEVEL 2, BETWEEN FRAMES 21-22. MX PERFORMED, COMPLETED AND COMPLIED WITH ALL WORK IAW EC5330-02798. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA20130813309Battery · dischargedDURING INSPECTION, BOTH EMERGENCY LIGHT EXIT SIGNS WERE FOUND TO BE INOPERATIVE. MX REPLACED THE NR 3 EMERGENCY LIGHT BATTERY. OPS CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA20130813006Battery · abnormalBATTERY FAILS TO HOLD A CHARGE. R & R NR 1 EMERGENCY BATTERY IAW AMM 33-50-04, CHECK GOOD.SDR ASOA20130814208VBeam · corrodedDURING C-CHECK THE CARGO DOOR CUTOUT LOWER BEAM WAS FOUND TO BE CORRODED. MX R & R THE BEAM IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130814207VSkin · crackedDURING C-CHECK, THE LT AFT FUSELAGE SKIN WAS FOUND TO BE CRACKED AROUND A FASTENER AT FRAME 79, STRINGERS 3L-4L. MX REAMED THE CRACK AND PERFORMED A BUSHING REPAIR IAW EC5330-02796. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130814206Frame · corrodedDURING C-CHECK THE PASSENGER DOOR LOWER FRAME WAS FOUND TO BE CORRODED. MX REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EC5210-01154, REV B. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130814205Hinge Fitting · wornDURING C-CHECK THE SERVICE DOOR MAIN HINGE LOWER BRACKET UPPER FITTING WAS FOUND TO BE WORN AND WOULD NOT RETAIN THE HAT BUSHING. MX REPAIRED THE HINGE ASSY IAW EC5240-01036, REV A. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130814204Fitting · corrodedDURING C-CHECK THE FRAME 75 VERTICAL STAB FITTING WAS FOUND TO HAVE FRETTING CORROSION BETWEEN STRINGERS 2R-2L. MX REMOVED THE CORROSION AND REPAIRED THE FITTING IAW EC5310-01317, REV C. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20130813004Lamp · inoperativeCEILING EMERGENCY LIGHT INOPERATIVE AT ROW 12. R & R LAMP IAW AMM 33-50-08.SDR SIMA20130813005Light · wrong partF/A REPORTED EMERGENCY FLOOR LIGHT STRIP IS INCORRECT AT OVERWING EXIT. R & R EMERGENCY LIGHT STRIP AT EMERGENCY ROW SEAT 9A IAW AMM 33-50-12. OPS CHECK GOODSDR SIMA20130813002Splice · looseAFT OVERWING CEILING EXIT SIGN INOPERATIVE. FOUND LOOSE SPLICE SP 9124, RECONNECTED. OPS CHECK GOOD IAW 33-50-15.SDR SIMA20130813003Connector · brokenSERVICE DOOR EMERGENCY LIGHT CONNECTOR BROKEN. REPAIRED SLICE SP7376 IAW SWPM 20-21-00.SDR SIMA20130812002Lamp · inoperativeLEFT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R LAMP IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A, OPS CHECKED GOOD.SDR ASOA20130812094Flapper Valve · leakingFUEL LEAK FROM LT WING REPORTED. MX R & R THE LT WING FLAPPER VALVE WITH LEAK CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130812062Valve · leakingTHE CREW REPORTED A SUSPECTED FUEL LEAK IN OTBD LT WING DURING FLIGHT. MX INSPECTED AND REPLACED A LT WING FUEL FLAP VALVE. OPS CHECKS WERE GOOD .SDR ASOA20130812148HFlapper Valve · leakingTHE CREW REPORTED FUEL LEAKING FROM THE LT WING. THE ACFT RETURNED TO DEPARTURE WITHOUT INCIDENT. MX R & R THE AFFECTED FLAPPER VALVE, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20130812004Skin · corrodedCENTER FUSELAGE SKIN CORROSION, FRAME 17-19, STRINGERS 21L-21R. INSTALLED DOUBLER IAW EO-EM-53MR-2179.SDR SIMA20130812003Crossbeam · crackedDURING MBV INSPECTION, FOUND CROSSBEAM SUPPORT IN THE NOSE WHEELWELL CRACKED. R & R CROSSBEAM IAW SRM 51-40-02.SDR SIMA20130813001Skin · crackedDURING MBV INSPECTION, FOUND REAR FUSELAGE SKIN HAS A CRACK APPROXIMATELY .2500 IN LONG AT FR 75, STR 2L. REPAIRED FUSELAGE SKIN IAW EO EM-53MR-2174.SDR SIMA20130811006Acm · failedCREW REPORTED, WHEN NR 2 PACK IS RUNNING THERE IS CLUNKING NOISE AND BAD ODOR. WHEN NR 2 PACK IS TURNED OFF, NOISE AND ODOR GOES AWAY. PERFORMED FIM TASK 21-51-00-810-824-A BLOCK 1 THRU 7 AND R & R NR 2 PACK VALVE IAW AMM 21-51-01 AND R & R OVER TEMPERATUSDR RAIA201308110001Handle · lack of lubeMAIN CABIN DOOR HARD TO OPEN FROM INSIDE. MX LUBRICATED HANDLE AND LOCKING MECHANISM AND OPS CHECK GOOD.SDR SIMA20130811003Battery · inoperativeLEFT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R NR 4 BATTERY AND CHARGER IAW WC 33-700-19, OPS CHECKED GOOD, NO DEFECTS NOTED.SDR SIMA20130811002Flashlight Assy · inoperativeCHARGING LIGHT INOPERATIVE FOR AFT CABIN FLASHLIGHT. R & R AFT FLASHLIGHT ASSY IAW AMM 33-50-16. OPS CHECKED GOOD.SDR SIMA20130811004Rib · crackedDURING HMBV INSPECTION, FOUND RT WING RIB 5 CRACKED. ACFT REMOVED FROM SERVICE. R & R RT WING RIB 5 IAW EO-EM-57MR-595R1.SDR SIMA20130811005Rib · crackedLEFT RIB 5 CRACKED AT AFT LIGHTNING HOLE. RIB REPAIRED IAW EO EM-57MR-699.SDR SIMA20130810003Skin · corrodedDURING HMBV INSPECTION, FOUND FUSELAGE OUTER SKIN CORRODED AFT OF FRAME 14 AND S18-19R. FOUND ADDITIONAL CORROSION ON INNER SKIN BETWEEN FRAMES 13 - 14 AND S18-21R. ACFT REMOVED FROM SERVICE. CUT OUT DAMAGE, FABRICATED AND INSTALLED SKIN SECTION, EXTERNAL SDR SIMA20130810002Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. R & R LAMP IAW AMM TASK 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECKED GOOD.SDR SIMA20130810001Pump · failedDURING CLIMB, RECEIVED EICAS MESSAGE HYD 1 LOW QTY. FOLLOWED AOM PROCEDURES MONITORED HYD 1 QTY INDICATION. HYD 1 QTY INDICATION BELOW AMBER RANGE AND PRESSURE DROP TO 2900 PSI. AN EMERGENCY WAS DECLARED AND DIVERTED. LANDING WAS UNEVENTFUL AND HYD 1 QTY SDR ASOA20130809092RUnknown · odorPILOT REPORTED A STRONG EXHAUST/FUEL ODOR IN FLIGHT DECK AND CABIN THROUGHOUT FLIGHT. MX RAN THE ENGINES AND APU WITH NO FUEL OR EXHAUST ODOR NOTED. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20130809003Roller · lack of lubeMAIN CABIN DOOR LEVER HARD TO MOVE. LUBED ROLLER IAW REF AMM 20-30-02. OPS CHECKED GOODSDR SIMA20130809004Lamp · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R LAMP IAW AMM TASK 33-50-06-000-801-A AND 33-50-06-400-801-A. OPS CHECKED GOOD.SDR ASOA20130809061Windshield · crackedTHE CREW REPORTED ENROUTE, THE CAPTAINS WINDSHIELD CRACKED/SHATTERED. THE ACFT DIVERTED AND LANDED WITHOUT FURTHER INCIDENT. MX REPLACED THE CAPTAINS WINDSHIELD. OPS CHECKS WERE GOOD AND THE ACFT WAS RELEASED FOR SERVICE.SDR ASOA20130811201VDoor Frame · corrodedDURING C-CHECK THE SERVICE DOOR CUTOUT AFT FRAME 22 AT STRINGER 15-16R WAS FOUND TO BE CORRODED. MX REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EC5310-01373. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130811200Shear Tie · corrodedDURING C-CHECK THE SHEAR TEI AT FRAME 65, STRINGER 16L WAS FOUND TO BE CORRODED. MX REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EC5320-01494. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130811199VBeam · corrodedDURING C-CHECK THE CARGO DOOR LOWER CUTOUT BEAM WAS FOUND TO BE CORRODED. MX R & R THE BEAM IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20130808008Wire · brokenNR 1 EMERGENCY LIGHT HAS BROKEN WIRES. R & R LIGHT IAW AMM 33-50-12, OPS CHECKED GOOD.SDR RAIA201308060001Radar · malfunctionedWEATHER RADAR PAINTING FALSE ECHO'S WHEN SWEEPING IN FLIGHT. RETURNED FLIGHT AND MX REPLACED WEATHER RADAR AND OPS CHECKED GOOD.SDR ASOA20130808061Acm · faultyTHE CREW REPORTED A PACK 1, OVERHEAT ON EICAS WITH BAD ODOR IN COCKPIT. MX REPLACED THE NR 1 ACM. OPS CHECKED GOOD.SDR SIMA20130808004Skin · crackedDURING HMBV INSPECTION, FOUND A CRACK ON FUSELAGE SKIN AFT 75 INCHES AND BELOW STRINGER 2R. ACFT REMOVED FROM SERVICE. CUTOUT DAMAGE, FABRICATED AND INSTALLED FILLER AND DOUBLER AND REPAIR ANGLE IAW EO EM-53MR-2175. INSTALLED FILLER AND DOUBLER AND REPAISDR SIMA20130808003Connector · loosePASS COMPT FWD EMERGENCY LIGHT WILL NOT ILLUMINATE. FOUND LOOSE CONNECTOR FOR CABIN FWD EMERGENCY LIGHT IAW AMM 33-50-12. OPS CHECKED GOOD.SDR SIMA20130808001Fuse · inoperativeBOTH LEFT AND RIGHT AFT OVERWING EXTERNAL EMERGENCY LIGHTS FAILED TO ILLUMINATE. R & R 5 AMP FUSE IN NR 4 EMERGENCY LIGHTING BATTERY CHARGER IAW CMM 25-60-03. OPS CHECKED GOOD.SDR SIMA20130807012O-Ring · leakingA BLEED LEAK EICAS MESSAGE ON NR 1 ENGINE. RAN CHECK LIST, DECLARED AN EMERGENCY AND DIVERTED. BLEED LEAK INDICATION WENT AWAY AFTER THE COMPLETION OF THE OF THE CHECKLIST. LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. INSPECTED ALL JOPINTS ON NR 1 SDR ASOA20130807060Unknown · unknownEMERGENCY LIGHTS OVER THE EXIT ROWS WOULD NOT LIGHT, DURING TEST. MX INSPECTED AND PERFORMED OPS CHECKS OF THE EMERGENCY LIGHTS. NO DEFECTS WERE FOUND. OPS CHECKED GOOD.SDR SIMA20130807011Flashlight · missingAFT FLASHLIGHT MISSING. FLASHLIGHT INSTALLED AND OPS CHECKED GOOD IAW AMM 33-50-16. RETURNED TO SERVICE.
Back to Embraer EMB-145LR