Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA11IA054Display · malfunctionedAUS - FLIGHT 2283, DURING POST FLIGHT INSPECTION THE CREW REPORTED THE PFD1 CIRCUIT BREAKER POPPED WITH AN ELECTRICAL SMELL. THE 31 PFD WAS PLACED ON MEL, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. THE AIRCRAFT LANDED AT IAH WHERE MAINTENANCE REMOVESDR SIMA201108010Light · inoperativeDURING MAINTENANCE BASE VISIT FOUND AFT LEFT OVERWING EMERGENCY LIGHT TO BE INOBERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE AFT LEFT WING EMERGENCY LIGHT. THE OPERATIONAL CHECK WAS GOOD IAW EMB AMM 33-50-07. THE AIRCRAFT WAS RETSDR C2XA11TY030Control Lever · brokenLANDING GEAR AIR/GRND FAIL MSG AFTER TAKEOFF. REMOVED AND REPLACED LANDING GEAR CONTROL LEVER IAW EMB 145 AMM 32-32-00, OPS CHECK GOOD.SDR C2XA11TY032Smoke Detector · defectiveTHE FORWARD SMOKE DETECTOR IN CARGO HAS A STEADY LIGHT ON. REMOVED AND REPLACED DETECTOR IAW EMB 145 AMM 26-15-01. OPS CHECK GOOD.SDR CA110318006Floor Support · corroded(CAN) CORROSION FOUND ON EXISTING REPAIR ON LT OMEGA BEAM FLANGE AT FRAME 20. SEE ALSO SDR 2011041600757 CHQA201100108.SDR CHQA201100067Light · inoperativeDURING INSPECTION THE RIGHT OVERWING EXTERIOR EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE RIGHT OVERWING EXTERIOR EMERGENCY LIGHT WITH NO FURTHER DEFECTS NOTED.SDR CHQA201100066Battery · failedDURING INSPECTION THE NR 2 EMERGENCY LIGHT BATTERY WAS FOUND TO HAVE FAILED. MAINTENANCE REPLACED THE NR 2 EMERGENCY LIGHT BATTERY WITH NO FURTHER DEFECTS NOTED.SDR SIMA201108009Cable · out of adjustFOR FLIGHT 4005 DURING PRE FLIGHT INSPECTION FOUND THE MAIN PASSENGER DOOR LEVER STUCK HALFWAY THRU UNLOCKING. THE AIRCRAFT WAS REMOVED FROM SERVICE. ADJUSTED CABLE D FOR THE MAIN DOOR IAW EMB 145 AMM 52-18-00-820-804. NO PARTS REMOVED OR REPLACED. THE AIRSDR SIMA201107702Lamp · intermittentFOR FLIGHT 3641 DURING PRE FLIGHT INSPECTION FOUND THE EXTERNAL RIGHT LOWER FORWARD FAIRING EMERGENCY LIGHT TO WORK INTRMITTENTLY. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE RIGHT LOWER FORWARD FAIRING EMERGENCY LIGHT. THE OPERATIONAL TSDR V0XR201103170001Gusset · damaged(V0XR) RT INBOARD WING LEADING EDGE TO FWD BODY FAIRING GUSSET MISS-DRILLED. REMOVED AND REPLACE GUSSET. W/C 6033,SDR RAIA201103170001Roller · out of adjustDURING POST FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE PASSENGER DOOR HARD TO OPEN. AIRCRAFT FLEW A FERRY FLIGHT TO IAD. MAINTENANCE INSPECTED AND ADJUSTED THE PASSENGER DOOR ROLLERS. PASSENGER DOOR OPS CHECKED GOOD.SDR C2XA11CL074Wire Harness · faultyORD FLT 6008 THE CREW REPORTED A LOUD "CLUNK" NOISE WHEN RETRACTING AND EXTENDING THE GEAR. MAINTENANCE INSPECTED AND REPLACED THE EXTEND/RETRACT SOLENOID. THE NOISE CAME BACK ON FLT 5809. MAINTENANCE INSPECTED AND REPLACED THE NOSE LANDING GEAR DOWNLOCK HASDR C2XA11CL072Unknown · odorORD FLT 6144 THE CREW REPORTED A BURNING SMELL IN THE COCKPIT AND FORWARD CABIN ON TAXI IN. MAINTENANCE INSPECTED AND COULD NOT DUPLICATE ANY BURNING SMELL. OPERATIONAL CHECKS WERE GOOD IAW 21-20-00-810-801-1. THE SMELL WAS ALSO NOTED ON FLIGHT 5910. MAINTESDR C2XA11CL071Module · intermittentCLE FLT 2760 THE CREW REPORTED DURING CLIMBOUT THE CABIN DIFFERENTIAL PRESSURE BEGAN TO FLUCTUATE ERRATICALLY BETWEEN 0 AND 9.0 PSI. CABIN PRESSURE AND CABIN RATE NORMAL. CONTINUED FLIGHT TO CLE WITH NO PRESSURE PROBLEMS. CABIN DIFFERENTIAL PRESSURE CHANGEDSDR CHQA201100108Floor Support · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE FLOOR STRUCTURE CENTER FUSELAGE I MIDDLE OMEGA BEAM BETWEEN FRAME 19 AND 25. MAINTENANCE REPLACED THE FLOOR STRUCTURE CENTER FUSELAGE I MIDDLE OMEGA BEAM BETWEEN FRAME 19 AND 25 AND INSTALLED WITH A SOLID RIVET IAWSDR CHQA201100063Seal · looseSHORTLY AFTER TAKEOFF, THE FLIGHT CREW REPORTED A NOISE COMING FROM JUST AFT OF THE CAPTAIN'S DV WINDOW. THEY COULD SEE SOMETHING SLAPPING THE FUSELAGE BUT COULD NOT IDENTIFY WHAT IT WAS SO THE AIRCRAFT RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MAINTENASDR CHQA201100107Angle · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE CARGO FLOOR STRUCTURE ENTRANCE FORWARD SIDE ANGLE. MAINTENANCE REPLACED THE CARGO FLOOR STRUCTURE ENTRANCE FORWARD SIDE ANGLE AND INSTALLED WITH A SOLID RIVET IAW SRM 51-40-02.SDR C2XA11IA057Acm · malfunctionedFAR - FLIGHT 6084, DURING NR 2 ENGINE START WITH THE NUMBER ONE PACK ON, THE CREW REPORTED SMOKE IN THE COCKPIT. CONTRACT MAINTENANCE INSPECTED THE AIRCRAFT AND FOUND A FINE DEBRIS TO BE COMING FROM THE PACK, AND NOT SMOKE. MAINTENANCE PLACED THE NUMBER ONE SDR C2XA11CL073Acm · faultyFAR FLT 6084 THE CREW REPORTED SMOKE IN THE COCKPIT AFTER NR 2 ENGINE START WITH NR 1 PACK ON. MAINTENANCE INSPECTED AND PLACED THE NR 1 PACK ON MEL. THE AIRCRAFT WAS RELEASED FOR SERVICE. MAINTENANCE REPLACED THE NR 1 PACK AIR CYCLE MACHINE. OPERATIONAL CSDR C2XA11CL072AUnknown · smokeFAR FLT 6084 THE CREW REPORTED SMOKE IN THE COCKPIT AFTER NR 2 ENGINE START WITH NR 1 PACK ON. MAINTENANCE INSPECTED AND PLACED THE NR 1 PACK SYSTEM ON MEL. THE AIRCRAFT WAS RELEASED FOR SERVICE. SUPPLEMENT TO FOLLOW.SDR CHQA201100062Windshield · crackedDURING CLIMBOUT, THE FLIGHT CREW REPORTED THAT THE CAPTAIN'S WINDSHIELD OUTER PANE CRACKED. THE AIRCRAFT DIVERTED TO KCMH AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE CAPTAIN'S WINDSHIELD WITH NO FURTHER DEFECTS NOTED.SDR C2XA11TY028Shim · wornTYS - A/C WAS TAXI FOR TAKEOFF AND IN CLIMBOUT, WHEN GEAR STOWED, CREW REPORTED A RATTLING NOISE WHEN GEAR STOWED. A/C WAS FERRIED TO TYS FROM BNA WHERE MAINTENANCE REMOVED THE NOSE GEAR AND FOUND THAT GEAR NEEDED TO BE SHIM. MAINTENANCE MEASURED THE BEARINSDR C2XA11SH068Frame · crackedSHV - DURING C-CHECK FR 10 IS CRACKED JUST BELOW LT DV WINDOW. REMOVED AND REPLACED FR 10 IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH067Fitting · crackedSHV - DURING C-CHECK NR 1 ENGINE FWD LOWER YOKE FITTING IS CRACKED. REMOVED AND REPLACED NR 1 ENG YOKE FITTING IAW EC5450-01028. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA201100061Velocity Sensor · faultyCREW REPORTED THAT DURING APPROACH WHEN THE FLAPS WERE SELECTED, RECEIVED A FAIL MESSAGE WITH THE FLAPS STILL AT ZERO. THE FLIGHT CREW DECLARED AN EMERGENCY AND THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE RIGHT FLAP VELOCITY SENSOR AND THESDR CHQA201100060Warning System · false activationON DESCENT THE FLIGHT CREW REPORTED A FLAP FAIL MESSAGE WHEN ATTEMPTING TO DEPLOY FLAPS. THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE WAS UNABLE TO DUPLICATE THE FAULT ON THE GROUND AND THE FLAPS WERE OPERATING NORMALLY AT THAT TIME. THE AIRCRAFT WAS TSDR SIMA201107402Beam · corrodedDURING MAINTENANCE BASE VISIT FOUND THE GALLEY CENTER HAT BEAM CORRODED AT FRAME 20. THE AIRCRAFT WAS REMOVED FROM SERVICE. COMPLIED WITH AEA EO EM-53MR-1787 FOR REPAIRS. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR C2XA11SH066Floor Support · corrodedSHV - DURING C-CHECK LT OMEGA BEAM LOWER FLANGE HAS CORROSION (LEVEL 3 LOCAL) AT FRAME 20. MAINTENANCE PERFORMED BEAM SPLICE REPAIR ON LT OMEGA BEAM AT FRAME 19-23 AND RESTORED TO ORIGINAL FINISH IAW EMB-145 EC5320-01229 REV ORIG. THE AIRCRAFT WAS APPROVED FSDR C2XA11SH065Floor Support · corrodedSHV - DURING C-CHECK RT OMEGA BEAM AT FRAME 18 IS CORRODED (LEVEL 2 LOCAL). MAINTENANCE PERFORMED REPAIR ON RT OMEGA BEAM AT FRAME 18 IAW EMB-145 SRM 51-40-02 AND CPM 51-21-06. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH064Doubler · damagedSHV - DURING C-CHECK BOUBLER AT FRAME 22 IS CORRODED (LEVEL 2 LOCAL) AND BENT. MAINTENANCE PERFORMED REPAIR ON DOUBLER AT FRAME 22 IAW EMB-145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA201107305Smoke Detector · false activationON FLIGHT 3314 ON APPROACH TO DFW THE CREW REPORTED, RECEIVED A CARGO SMOKE WARNING ON EICAS. THE CREW FOLLOWED AOM PROCEDURES AND USED FIRE BOTTLES. THE CAPTAIN DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT AND TAXIED TO RAMP. NO FIRE OR SMOKE NOTED INSDR SIMA201107404Fan · inoperativeON FLIGHT 3693 THE CREW REPORTED A LOUD WHIRRING NOISE THAT BEGAN AT 3000 FEET ON FINAL TO MIA FOLLOWED BY A HOT ELECTRIC WIRING ACRID ODOR DURING THE REMAINDER OF FLIGHT. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED SDR C2XA11CL069Actuator · faultyIAD FLT 5821 THE CREW REPORTED A LAV SMOKE WARNING MESSAGE ON TAKEOFF. ALSO REPORTED A SMOKE SMELL. NO SMOKE WAS NOTED. THE AIRCRAFT RETURNED TO IAD AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NR 2 ENGINE CVG ACTUATOR. OPERATIONAL SDR CHQA201100059Brake · failedCREW REPORTED THAT ON APPROACH THERE WAS A FLAP FAIL MESSAGE WHEN SELECTING FLAPS FROM 0-9. ON CALL MAINTENANCE COULD NOT DUPLICATE FAULT ON GROUND AND OPERATIONAL CHECKS WERE GOOD. LATER THAT DAY, DUE TO CMC MESSAGING, KSDF MAINTENANCE REPLACED THE RIGHT FLSDR SIMA201107303Fan · inoperativeON FLIGHT 3644 DURING TAXI THE CREW REPORTED A HOT ELECTRICAL WIRE INSULATION ODOR IN THE COCKPIT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE ATTITUDE HEADING REFERENCE UNIT FAN IAW AMM 34-21-03. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR CHQA201100118Floor Support · crackedDURING INSPECTION A CRACK WAS FOUND ON THE LEFT OMEGA BEAM ANGLE AT FRAME 47. MAINTENANCE REPAIRED THE LEFT OMEGA BEAM ANGLE AT FRAME 47 IAW SRM 53-23-02.SDR CHQA201100117Floor Support · crackedDURING INSPECTION A CRACK WAS FOUND ON THE RIGHT OMEGA BEAM ANGLE AT FRAME 47. MAINTENANCE REPAIRED THE RIGHT OMEGA BEAM ANGLE AT FRAME 47 IAW SRM 53-23-02.SDR CHQA201100116Floor Support · crackedDURING INSPECTION A CRACK WAS FOUND ON THE RIGHT OMEGA BEAM ANGLE AT FRAME 47. MAINTENANCE REPAIRED THE RIGHT OMEGA BEAM ANGLE AT FRAME 47 IAW SRM 53-23-02.SDR CHQA201100115Floor Support · crackedDURING INSPECTION A CRACK WAS FOUND ON THE RIGHT OMEGA BEAM ANGLE AT FRAME 47. MAINTENANCE REPAIRED THE RIGHT OMEGA BEAM ANGLE AT FRAME 47 IAW SRM 53-23-02.SDR CHQA201100106Support · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE CABIN FLOOR STRUCTURE CENTER FUSELAGE I ANGLE MIDDLE SUPPORT. MAINTENANCE REPLACED THE CABIN FLOOR STRUCTURE CENTER FUSELAGE I ANGLE MIDDLE SUPPORT AND INSTALLED WITH A SOLID RIVET IAW SRM 51-40-02.SDR CHQA201100105Rib · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE CABIN FLOOR STRUCTURE CENTER FUSELAGE I AFT GALLEY RIB. MAINTENANCE REPLACED THE CABIN FLOOR STRUCTURE CENTER FUSELAGE I AFT GALLEY RIB AND INSTALLED WITH A SOLID RIVET IAW SRM 51-40-02.SDR CHQA201100104Structure · corrodedDURING INSPECTION THE CABIN FLOOR STRUCTURE CENTER FUSELAGE I PASSENGER DOOR U SHAPE WAS FOUND TO BE CORRODED. MAINTENANCE REPLACED THE CABIN FLOOR STRUCTURE CENTER FUSELAGE I PASSENGER DOOR U SHAPE AND INSTALLED WITH A SOLID RIVET IAW SRM 51-40-02.SDR CHQA201100103Floor Support · corrodedDURING INSPECTION THE CABIN FLOOR STRUCTURE LEFT OMEGA BEAM AFT ANGLE AT FRAME 20 WAS FOUND TO BE CORRODED. MAINTENANCE REPLACED THE CABIN FLOOR STRUCTURE LEFT OMEGA BEAM AT FRAME 20 IAW SRM 51-40-02.SDR CHQA201100102Beam · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE CARGO DOOR SURROUND STRUCTURE LOWER BEAM. MAINTENANCE REPLACED THE CARGO DOOR SURROUND STRUCTURE LOWER BEAM IAW SRM 51-40-02.SDR CHQA201100101Floor Support · corrodedDURING INSPECTION CORROSION WAS FOUND ON AN EXISTING REPAIR ON THE LEFT OMEGA BEAM FLANGE AT FRAME 20. MAINTENANCE REPAIRED THE LEFT OMEGA BEAM FLANGE AT FRAME 20 AND RE-INSTALLED IAW SRM 53-00-10.SDR C2XA11IA052Proximity Sensor · faultyDURING FLIGHT THE CREW RECEIVED SPOILER FAIL AND SPOILER OPEN MESSAGES. THE AIRCRAFT RETURNED TO IAH AND LANDED WITHOUT INCIDENT WHERE MAINTENANCE REPLACED A SPOILER PROXIMITY SENSOR. OPERATIONAL CHECKS WERE PERFORMED AND THE DISCREPANCY WAS CLEARED.SDR C2XA11IA051Unknown · odorEN ROUTE TO GSO THE CREW REPORTED A BURNING SMELL IN FRONT OF THE CABIN. THE AIRCRAFT DIVERTED TO MOB WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED AN INSPECTION OF THE AIRCRAFT, HIGH-POWER ENGINE RUNS AND OPERATES THE AIR CONDITIONING PACKS HOWEVESDR CHQA201100058Unknown · odorCREW REPORTED THAT ON DESCENT, AFTER ANTI-ICE SYSTEM WAS ACTIVATED, THAT THERE WAS A BURNING SMELL IN THE COCKPIT. ON CALL MAINTENANCE INSPECTED THE ELECTRICAL AREA BEHIND THE CAPTAIN'S SEAT, AND PERFORMED OPERATIONAL CHECKS OF THE ANTI-ICING AND BLEED SYSTEMSDR C2XA11SH063Skin Panel · damagedAC N29917 FERRIED INTO SHV BECAUSE OF GROUND DAMAGE BY LAVATORY TRUCK. SKIN PANEL AT FRAME 61-66 STRINGER 16R TO 19L HAS DAMAGE. FERRY FLIGHT CONDITIONS WERE TO "SECURE BOTH OUTFLOW VALVES, TRIM JAGGED MATERIAL FROM AROUND PUNCTURED AREAS, RE-CONTOUR PUNCTURSDR RAIA201103100001Unknown · odorDURING CRUISE THE FLIGHT CREW REPORTED A STRONG SMELL OF BURNING WIRES COMING FROM THE COCKPIT RADOME AREA. MAINTENANCE INSPECTED WIRING AND HARNESSES THROUGH ACCESS PANELS FOR RADOME ZONE LT FORWARD ELECTRONIC BAY PANEL, 113CZ BELOW COCKPIT AREA ZONE 123 PAN
Back to Embraer EMB-145LR