Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CHQA201100055O-Ring · tornCREW REPORTED THAT DURING CRUISE REPORTED A BLEED 2 LEAK MESSAGE IN ICING CONDITIONS ACCOMPANIED BY A BURNT RUBBER ODOR. THE AIRCRAFT DIVERTED TO KBTV AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND A LEAK AT JOINT 19 BEHIND THE CARGO COMPARTMENT SIDE WALL. SDR C2XA11CL068Apu · failedTHE CREW REPORTED AN APU FAIL MESSAGE ALONG WITH A ELECTRICAL SMELL. MAINTENANCE INSPECTED AND REPLACED THE APU. OPERATIONAL CHECKS WERE GOOD.SDR V0XR201103090002Attach Angle · crackedLT AFT REAR RIB ATTACHMENT ANGLE CRACKED. R & R RIB.SDR C2XA11IA050Actuator · leakingON APPROACH INTO FAR THE CREW RECEIVED A GEAR AIR/GROUND FAIL MESSAGE. THE CREW ELECTED TO ABORT THE APPROACH AND THE MESSAGE EXTINGUISHED HOWEVER ON THE SECOND GEAR EXTENSION THE MESSAGE APPEARED AGAIN. THE AIRCRAFT LANDED IN FAR WITHOUT INCIDENT. THE AIRCSDR RAIA201103090001Battery · dischargedDURING PRE-FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE EMERGENCY LIGHT AT 18A WAS INOP. MAINTENANCE INSPECTED AND REMOVED AND REPLACED THE BATTERY. SYSTEM OPS CHECKED GOOD.SDR CHQA201100053Light · inoperativeDURING INSPECTION, THE RIGHT OVERWING EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE RIGHT OVERWING EMERGENCY LIGHT ASSEMBLY WITH NO FURTHER DEFECTS NOTED.SDR C2XA11CL067Unknown · malfunctionedORD FLT 5929 THE CREW REPORTED THE AIRCRAFT WOULD NOT PRESSURIZE ON CLIMB. LOUD SQUEAL FROM RIGHT SIDE WINDOW WAS REPORTED AS WELL. MAINTENANCE INSPECTED AND RELEASED AIRCRAFT IAW MEL 21-30-00/3. MAINTENANCE INSPECTED AND PERFORMED AUTO AND MANUAL PRESSURIZSDR C2XA11SH062Frame · crackedSHV - DURING C-CHECK RT FRAME 10 CRACKED. REMOVED AND REPLACED FRAME 10 IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA201106903Adc · malfunctionedON FLIGHT 2771 DURING CRUISE THE CREW REPORTED THE COCKPIT HAD A BURNING ODOR IN ICING CONDITIONS AND WINDSHIELDS WERE ICED OVER. THE CAPTAIN DECLARED AN EMERGENCY. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND RESDR RAIA2011030800001Mechanism · dirtyCREW REPORTED THAT THE PASSENGER DOOR WAS DIFFICULT TO OPEN AND CLOSE. MAINTENANCE INSPECTED, CLEANED AND LUBED THE PASSENGER DOOR MECHANISM AND PERFORMED AN OPERATIONAL CHECK OF THE DOOR. NO DEFECTS NOTED.SDR C2XA11SH061Floor Support · corrodedSHV - DURING C-CHECK CENTER OMEGA BEAM HAS CORROSION AT FR 23. REMOVED AND REPLACED OMEGA BEAM IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH060Floor Support · corrodedSHV - DURING C-CHECK RT OMEGA BEAM HAS CORROSION AT FR 29. REPAIRED OMEGA BEAM IAW EMB 145 SRM 53-00-10. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH059Floor Support · corrodedSHV - DURING C-CHECK RT OMEGA BEAM HAS CORROSION AT FR 53-59. REPAIRED OMEGA BEAM IAW EMB 145 SRM 53-00-10. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH058Floor Support · corrodedSHV - DURING C-CHECK LT OMEGA BEAM HAS CORROSION AT FR 58-59. REPAIRED OMEGA BEAM IAW EC5310-01466. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH057Floor Support · corrodedSHV - DURING C-CHECK LT OMEGA BEAM HAS CORROSION AT FR 49-50. REPAIRED OMEGA BEAM IAW EMB 145 SRM 53-00-10. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SH056Floor Support · corrodedSHV - DURING C-CHECK LT OMEGA BEAM HAS CORROSION AT FR 44. REPAIRED OMEGA BEAM IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA201100050Check Valve · damagedFLT CREW REPORTED WHILE CLIMBING THROUGH FL270, RECEIVED A "CABIN" AURAL WARNING. NO RELATED EICAS MESSAGES DISPLAYED. CABIN PRESSURE INDICATED OVER 10,000FT & REPORTED TO BE CLIMBING TO 11,000FT. MEMORY ITEMS FOLLOWED & ACFT BEGAN DESCENT TO 10,000FT & DECSDR C2XA11RI041Fire Detector · failedFLIGHT 3088 - EWR - FLIGHT CREW REPORTED E1 FIRE DETECT FAIL INDICATION ON EICAS. EWR MX REMOVED AND REPLACED NR 1 ENG FIRE DETECTOR AND PYLON FIRE DETECTOR, AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE. SDR C2XA11RI0SDR C2XA11RI040Fire Detector · failedFLIGHT 3088 - EWR - FLIGHT CREW REPORTED E1 FIRE DETECT FAIL INDICATION ON EICAS. EWR MX REMOVED AND REPLACED NR 1 ENG FIRE DETECTOR AND PYLON FIRE DETECTOR, AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE. SDR C2XA11RI0SDR C2XA11CL065Smoke Detector · intermittentPIA FLT 6118 THE CREW REPORTED A LAV SMOKE INDICATION. MAINTENANCE INSPECTED AND REPLACED THE LAV SMOKE DETECTOR. OPERATIONAL CHECKS WERE GOOD.SDR RAIA201103070002Linkage · lack of lubeDURING POST FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE PASSENGER DOOR WAS HARD TO OPEN. MAINTENANCE INSPECTED AND LUBED THE PASSENGER DOOR LINKAGES AND ROLLERS. DOOR OPS CHECKED GOOD.SDR C2XA11IA042Warning System · false activationDEN - FLIGHT 5897, THE CREW REPORTED A LANDING GEAR AIR / GRND FAIL MESSAGE ON CLIMB. THE AIRCRAFT RETURNED TO DEN WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT, OPERATIONALLY TESTED THE LANDING GEAR EXTENSION / RETRACTION SYSTEM MULTISDR C2XA11TY023Indication Sys · malfunctionedLAV SMOKE INDICATION. PERFORMED TEST OF LAV SMOKE INDICATION IAW EMB 145 AMM 26-14-00. OPS CHECK GOOD.SDR SIMA201106703Wire Harness · burnedON FLIGHT 4196 THE FLIGHT ATTENDANT REPORTED AN ELECTRICAL SMOKE ODOR OZONE SMELL FROM GASPER VENT AND OVER SEAT 1A. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND SEAT 4A CEILING LIGHT HARNESS ASSEMBLY RECEPTACLE BURNT. REMOVED AND REPLACED THE HARNESS ASSEMSDR C2XA11TY021Fuse · blownTYS - A/C WAS IN FOR A SERVICE CHECK WHEN THE LEFT AND RIGHT EXTERIOR OVERWING EMERGENCY LIGHTS WERE FOUND INOP. MAINTENANCE REMOVED AND REPLACED THE NR 4 EMERGENCY BATTERY SUPPLY FUSE IAW EMB 145 VCMM 33-21-70. OPC CHECK WAS GOOD AND THEN RELEASED TO SERVICSDR RAIA201103050002Duct · looseDURING CLIMB THE FLIGHT CREW GOT A WING A/ICE FAIL MESSAGE IN ICING CONDITIONS. AIRCRAFT MADE A RETURN FLIGHT TO IAD. MAINTENANCE INSPECTED AND FOUND A LOOSE DUCT. THE DUCT WAS RE-SECURED. ANTI-ICE SYSTEM OPS CHECK WAS PERFORMED AND SYSTEM OPS CHECKED GOODSDR C2XA11IA046Light · inoperativeIAH - DURING MAINTENANCE INSPECTION THE AISLE PATH LIGHT STRIP AT ROWS 8 & 9 WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED LIGHT STRIP, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11IA045Gasket · brokenIAH - FLIGHT 2281, THE CREW REPORTED A SMELL OF SMOKE IN THE CABIN WHEN FLYING THROUGH RAIN. THE AIRCRAFT LANDED AT OAH WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE AIRCRAFT. REMOVED AND REPLACED THE 9TH STAGE BLEED DUCT GASKETS AT THE CHECK VALVE, OPERASDR RAIA201103050001Strip · missingDURING POST FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE EMERGENCY FLOOR STRIP BY GALLEY MARKING EXIT WAS MISSING. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY LIGHT STRIP. SYSTEM OPS CHECKED GOOD.SDR C2XA11SHO54Skin · crackedSHV - DURING C-CHECK CRACK AROUND RIVET FRAME 75 STRINGER 2L-3L (VERIFIED WITH EDDY CURRENT). MAINTENANCE PERFORMED REPAIR OF FUSELAGE SKIN AT FRAME 75 STRINGER 2L-3L IAW EC5330-02353. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SHO53Floor Support · corrodedSHV - DURING C-CHECK CORROSION (LEVEL 3 LOCAL) ON LT OMEGA BEAM CROSSBEAM FLANGE AT FRAME 58-59. MAINTENANCE PERFORMED REPAIR ON LT OMEGA BEAM CROSSBEAM AT FRAME 58-59 IAW EC5310-01466 REV ORIG. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11SHO52Crossbeam · corrodedSHV - DURING C-CHECK CORROSION (LEVEL 2 LOCAL) ON LT OMEGA BEAM CROSSBEAM FLANGE AT FRAME 29. MAINTENANCE PERFORMED REPAIR ON LT OMEGA BEAM CROSSBEAM FLANGE AT FRAME 29 IAW EMB-145 SRM 53-00-10. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA11IA048Door Seal · dirtyIAH - FLIGHT 2572, THE CREW REPORTED A LOUD PRESSURIZATION SQUEAL AT FL350 AND 7.6DELTA P, AND CABIN PRESSURE WENT TO 9000 AT FL350. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT, CLEANED AND LUBRICATED THESDR RAIA201103040001Light · inoperativeDURING PRE-FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE PASSENGER DOOR EMERGENCY HANDRAIL LIGHT WAS INOP. MAINTENANCE INSPECTED AND DEFERRED THE LIGHT.SDR SIMA201106702Tube · defectiveON FLIGHT 3967 THE CREW REPORTED, RECEIVED NR 1 BLEED LEAK MESSAGE ON EICAS IN CLIMBOUT AT APPROX 5000". FOLLOWED AOM NR 1 CHECKLIST WITH NR 1 BLEED OFF MESSAGE REMAINED AFTER 3 MINUTES. TURNED NR 2 BLEED OFF MESSAGE WENT OUT AFTER APPROXIMATELY 4 MINUTES WSDR SIMA201106604Fan · seizedON FLIGHT 4111 DURING CRUISE THE CREW REPORTED THAT AT 21000FT A STRONG ELECTRICAL SMOKE ODOR WAS NOTICED BY THE COCKPIT CREW, FLIGHT ATTENDANT AND PASSENGER IN SEAT 1A. AS PER EPC WHEN SHED BUSES KNOB WAS SELECTED "OFF" ELECTRICAL SMOKE ODOR WENT AWAY. THE SDR SIMA201106603Proximity Switch · malfunctionedON FLIGHT 4067 THE CREW REPORTED THAT UPON TAKEOFF "LG AIR GROUND FAIL' APPEARED ON EICAS. THE CREW WAS UNABLE TO RETRACT THE GEAR. THE CAPTAIN DECLARED AN EMERGENCY AND ELECTED TO RETURN TO RIC. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVSDR SIMA201106602Warning System · malfunctionedON FLIGHT 3468 MAINTENANCE REPORTED THE CREW RECEIVED A SPOILER FAIL EICAS MESSAGE IN FLIGHT. MAI MAINTENANCE REPORTED THE CAPTAIN DECLARED AN EMERGENCY BUT THE CREW DID NOT CALL MOC TO REPORT THIS. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMSDR C2XA11TY022Inverter · inoperativeSECOND FLOOR PROXIMITY EMERGENCY LIGHT STRIP INOP. REMOVED AND REPLACED NR 3 EMERGENCY LIGHT INVERTER IAW EMB 145 AMM 33-50-11.SDR CHQA201100049Wire · brokenDURING INSPECTION THE NR 1 FLOOR PROXIMITY EMERGENCY LIGHT WAS FOUND TO HAVE BROKEN WIRES. MAINTENANCE REPLACED THE NR 1 FLOOR PROXIMITY LIGHT STRIP WITH NO FURTHER DEFECTS NOTED.SDR CHQA201100048Switch · intermittentFLIGHT CREW REPORTED A BLEED 1 VALVE CLOSED MESSAGE SHORTLY AFTER TAKEOFF AND RETURNED TO LGA AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE NR 1 BLEED PUSH BUTTON AND THE E1 FAN AIR VALVE FILTER AS A PRECAUTION, WITH NO FURTHER DEFECTS BEING NOTED DURSDR C2XA11CL063Sense Line · chafedCLE FLT 2659 THE CREW REPORTED A BLEED 2 OVERTEMP MESSAGE IN FLIGHT. THE AIRCRAFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NR 2 FAN AIR VALVE SENSE LINE. OPERATIONAL CHECKS WERE GOOD.SDR CHQA201100098Door Frame · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE SERVICE DOOR SURROUND LOWER PORTION AT FRAME NR 22. A THICKNESS MEASUREMENT WAS DONE BY UT IAW NDI MANUAL, INTRODUCTION P 22 (F). MINIMUM MATERIAL REMAINING IS 0.22 INCHES. A HIGH FREQUENCY EDDY CURRENT INSPECTIOSDR CHQA201100097Skin · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE SERVICE DOOR SURROUND LOWER PORTION AT FRAME NR 20. A THICKNESS MEASUREMENT WAS DONE BY UT IAW NDI MANUAL, INTRODUCTION P 22 (F). MINIMUM MATERIAL REMAINING IS 0.66 INCHES. A HIGH FREQUENCY EDDY CURRENT INSPECTIOSDR CHQA201100080Casting · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE MAIN PASSENGER DOOR STRUCTURE OPEN HANDLE BACK CASTING. THE MAIN PASSENGER DOOR OPEN HANDLE BACK CASTING WAS REPLACED.SDR CHQA201100079Channel · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE MAIN PASSENGER DOOR STRUCTURE FORWARD CHANNEL SPLICE. THE MAIN PASSENGER DOOR STRUCTURE FORWARD CHANNEL SPLICE WAS REPLACED.SDR CHQA201100092Reinforcement · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE SERVICE DOOR AFT SURROUND STRUCTURE. THE THICKNESS MEASUREMENT DONE BY UT IAW NDI MANUAL P.22 (F) ON REWORKED AREA FOUND THE MINIMUM MATERIAL THICKNESS REMAINING AT 0.022 INCHES. HFEC DONE ON THE AREA FOUND NO CRASDR CHQA201100091Floor Support · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE CABIN FLOOR STRUCTURE RIGHT OMEGA BEAM FLANGE AT FRAME 25. THE CABIN FLOOR STRUCTURE RIGHT OMEGA BEAM LOWER FLANGE AT FRAME 25 WAS REPAIRED IAW ETD2011-145/02427.SDR CHQA201100090Floor Support · corrodedDURING INSPECTION CORROSION WAS FOUND ON EXISTING REPAIR ON LEFT OMEGA BEAM FLANGE AT FRAME 20. THE REPAIR WAS REPLACED ON THE LEFT OMEGA BEAM FLANGE IAW SRM 53-00-10.SDR CHQA201100089Fitting · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE MAIN PASSENGER DOOR STRUCTURE AFT FITTING ON BOTTOM RIB. THE MAIN PASSENGER DOOR STRUCTURE AFT FITTING ON BOTTOM RIB WAS REPLACED.
Back to Embraer EMB-145LR