Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA2009010600004Warning System · malfunctionedE2 BLEED LEAK MSG. RAN E2 BLEED SYSTEM FOR OVER 45 MINUTES AND INSPECTED FOR LEAKS. NO DEFECTS NOTED AT THIS TIME PER AMM MX PROCEDURE.SDR RAIA2009010600003Light · inoperativeSTAIR EMERGENCY LIGHT INOP. PLACED ON DEFERRAL PER MX PROCEDURE.SDR C2XA09CL002Battery · dischargedDURING ROUTINE MX THE EMERGENCY FLOOR LIGHT CTR STRIP WAS FOUND INOPERATIVE. MX INSPECTED AND REPLACED THE NR3 EMERGENCY LIGHT BATTERY. OPS CHECKS WERE GOOD.SDR C2XA09CL001Switch · faultyCAE FLIGHT NR3114 THE CREW REPORTED A NO TAKEOFF CONFIG WARNING ON THE EICAS ON TAKE OFF ROLL. THE CREW ABORTED TAKEOFF AND TAXIED TO THE GATE. MX INSPECTED AND REPLACED THE PARKING BRAKE SWITCH AND RELAY K0212. OPS CHECKS WERE GOOD. RELAY P/N M83536/6-022M.SDR C2XA09TY007Bonding Strap · delaminatedBONDING STRAPES DELAMINATED ON PANEL 193. REMOVED AND REPLACED BONDING STRAPES IAW EC5750-01315. ACFT CURRENTLY IN C-CHECK.SDR C2XA09TY006Panel · damagedPANEL 193 HAS DAMAGE, SCREW HOLES. REPAIRED IAW EC5750-01315.SDR C2XA09IA004Controller · malfunctionedTHE CREW REPORTED, LEVEL AT FL360 RAPID DECOMPRESSION CABIN ALT REACHED 12,000. THE ACFT LANDED WITHOUT INCIDENT WHERE MX REMOVED AND REPLACED THE DIGITAL CONTROLLER, OPERATIONALLY TESTED AITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA200900266Battery Pack · inoperativeDURING A SERVICE CHECK THE OVER WING EMERGENCY LIGHTS WERE FOUND TO BE INOP. THE NR4 EMERGENCY LIGHT BATTERY WAS REPLACED AND THE EMERGENCY LIGHT SYS OPERATED NORMALLY.SDR FDKA2009010300005Battery Pack · dischargedFRL FLT RON CLT. BOTH OVER-WING EXTERIOR EMERGENCY LIGHTS WERE INOPERATIVE. MX REPLACED THE NR 4 BATTERY PACK AND OPS CHECKED.SDR FDKA2009010300004Battery Pack · malfunctionedFRL FLT 6254 JFK-BTV EMERGENCY LIGHT OVER ROW 12 INOP. MX RESET BATTERY PACK.SDR C2XA09RI001Bleed Valve · inoperativeBNA - FLIGHT 2573 - FLIGHT CREW REPORTED ENGINE NR 1 BLEED VALVE CLOSED IN FLIGHT AND THEY WERE UNABLE TO REOPEN. CREW PERFORMED AIR RETURN AND LANDED ACFT UNEVENTFULLY. MX R&R ENGINE BLEED VALVE AND PERFORMED OPS CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETSDR RAIA2009010600002Light · inoperativeEMERGENCY LIGHT INOP. REPLACED BULB PER AMM PROCEDURE. OPS CHK GOOD.SDR RAIA2009010600001Warning System · activatedNR 1 ENG BLEED MSG ON EICAS. MX DEFERRED NR 2 ENG BLEED PER MEL PROCEDURES.SDR FDKA20090102003Unknown · odorFRL FLT 6207 CLT-RON. PACK 2 HAS A BURNING SMELL WHEN THE APU BLEED IS ON. MX PERFORMED GROUND RUN AND OPS CHECKED SYSTEM NO DEFECT NOTED.SDR FDKA20090102002Seal · tornF/O HUMP SEAL TORN. TEMPORARY REPAIR F/O HUMP SEAL.SDR FDKA20090102001Guide · loosePAX DOOR HARD TO OPEN. MX FOUND FWD GUIDE LOOSE AND READJUSTED.SDR C2XA09IA010Connector · dirtyON TAKEOFF ROLL THE CREW REPORTED RELAYS CLICKING, AND AFTER TAKEOFF CLICKED AGAIN VERY LOUD AND A JOLT WAS FELT THROUGH THE YOLK AND RUDDER PEDALS. AT 12000 FT, THE LOUD CLICKING OCCURRED SEVERAL TIMES AND RECEIVED EMERG LIGHTS NOT ARMED AND ELEC EMERG ABNORSDR RAIA2009010500004Power Supply · dischargedDURING PRE-FLIGHT INSPECTION, SEVERAL EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MX R&R 1 OF THE EMERGENCY LIGHT POWER SUPPLIES AND R&R THE EXTERIOR LIGHT ASSEMBLY. SYSTEM OPS CHECKED GOOD.SDR RAIA2009010500003Warning System · activatedDURING CLIMB, CREW RECEIVED A BLEED 1 LEAK MSG ON THE EICAS. MX INSPECTED THE ACFT AND DEFERRED THE NR 1 ENGINE BLEED SYSTEM IAW MEL PROCEDURES. MAINTENANCE CLEARED DMI ON 01-01-09 AFTER TIGHTENING CLAMP AT NR 22 POSITION IAW WITH AMM PROCEEDURES. TESTED, OSDR RAIA2009010500002Light · inoperativeDURING PRE FLIGHT INSPECTION, THE CREW FOUND THAT THE EMERGENCY LIGHT AT THE AFT CEILING EXIT LOCATOR WAS INOPERATIVE. MX PERFORMED AN OPS CHECK OF THE EMERGENCY LIGHTING SYSTEM WITH NO DEFECTS NOTED.SDR RAIA2009010500001Light · malfunctionedDURING PRE-FLIGHT INSPECTION, THE CREW FOUND THE EMERGENCY LIGHT AT THE GALLEY TO BE INOPERATIVE. MX PERFORMED A TEST OF THE EMERGENCY LIGHT. THE SYSTEM CHECKED GOOD.SDR FDKA2008123000327Connector · looseFRL FLT 6189 JFK. OVERHEAD EMERGENCY EXIT ROW 12 INOP. MX RESECURED CONNECTOR AT LIGHT ASSY OPS GOOD.SDR C2XA08CL139Engine · malfunctionedIAH FLT THE CREW REPORTED A LAV SMOKE MESSAGE ON THE ECIAS AFTER TAKEOFF AT 3000FT. THE MESSAGE CLEARED AFTER THE CB E11 AND 12 WERE PULLED. THE ACFT RETURNED TO DEPARTURE AND LANDED WITHOUT INCIDENT. MX REPLACED THE NR 2 ENG AND OPS CHECKS WERE GOOD. SUPPLESDR C2XA08IA276Light · looseIAH - DURING MX INSPECTION THE EMERGENCY EXIT OVERHEAD LIGHT AT THE CENTER EXIT WAS FOUND TO BE INOPERATIVE. MX INSPECTED THE ACFT AND RECONNECTED THE EMERGENCY LIGHT, OPS TESTS WERE SATISFACTORY, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA2008123100001Wire · damagedDURING PREFLIGHT INSPECTION EMERGENCY LIGHT INOPERATIVE AFT OF CEILING LOCATOR. MX DISCOVERED A LOOSE WIRING CONNECTION. MX REPAIRED DISCREPANT WIRE CONNECTION. OPS CHECK GOOD.SDR SIMA200900904Smoke Detector · malfunctionedON FLIGHT 3862, CREW REPORTED JUST AFTER TAKE OFF, AS THE LANDING GEAR RETRACTED, LAV SMOKE ALARM ON EICAS AND ALARM IN THE LAV SOUNDED. BOTH WENT AWAY WHEN LANDING GEAR WAS RETRACTED. ACFT REMOVED FROM SERVICE . PERFORMED OPS CHECK OF LAV SMOKE DETECTION SYSSDR C2XA09IA001Smoke Detector · malfunctionedTHE CREW REPORTED A LAV SMOKE WARNING ION EICAS AFTER TAKEOFF. THE CREW PERFORMED QRH WITH NO SMOKE NOTED. THE ACFT LANDED WITHOUT INCIDENT WHERE MX REMOVED AND REPLACED THE LAV SMOKE DETECTOR PANEL, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROSDR RAIA2008123000001Wire · looseDURING THE PRE FLIGHT INSPECTION, MX FOUND THAT THE EMERGENCY LIGHT AT ROW 12 WAS INOPERATIVE. MX RESECURED WIRING TO THE INOPERATIVE LIGHT. SYSTEM OPS CHECKED GOOD.SDR FDKA2008122900326Door · dirtyFRL FLT 6259 CVG. MAIN CABIN DOOR HARD TO OPEN FROM THE INSIDE. MX CLEANED AND LUBED OPS GOOD.SDR C2XA08IA271Fire Loop · chafedIAH - FLIGHT 2386, THE CREW REPORTED A NUMBER ONE ENGINE FIRE DETECTOR FAIL IN FLIGHT. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE ENGINE FIRE LOOP. OPERATIONAL TESTS WERE SATISFACTORY, AND THE AIRCRAFT WSDR SIMA200900903Windshield · crackedON FLIGHT 4122, CREW REPORTED BOTH WINDSHIELDS SHATTERED ON TAKEOFF AT 125KTS. ACFT REMOVED FROM SERVICE. REMOVED AND REPLACED BOTH COCKPIT WINDSHIELDS. OPS CHECK GOOD. NO LEAKS NOTED. ACFT RETURNED TO SERVICE.
LT WINDSHIELD P/N OFF NP15131112 S/N OFF 0807SDR C2XA09IA002Smoke Detector · malfunctionedTHE CREW REPORTED A LAV SMOKE INDICATION RIGHT AFTER ROTATION. THE ACFT LANDED WITHOUT INCIDENT. MX REMOVED AND REPLACED THE LAV SMOKE SENSOR, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA08IA269Muffler · looseIAH - FLIGHT 2434, THE CREW REPORTED THAT THE PACK 2 VALVE CLOSED IN FLIGHT, AND WERE UNABLE TO RESET. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT AND RE-SECURED THE PACK 2 DISTRIBUTION MUFFLER, OPERATIOSDR C2XA08IA268Wire · brokenIAH - FLIGHT 2434, THE CREW REPORTED A PACK 1 VALVE CLOSED ADVISORY MESSAGE IN FLIGHT. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REPAIRED WIRE W101-2447-22 AT THE BUSHBUTTON FOR PACK ONE, OPERATIONALLY TESTED WITH NO DEFECTS,SDR C2XA08IA266Smoke Warning · malfunctionedIAH - FLIGHT 2356 - THE CREW REPORTED A LAV SMOKE INDICATION ON EICAS. THE CREW FOLLOWED THE QRH PROCEDURES WITH NO SMOKE NOTED. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE OPERATIONALLY CHECKED THE LAV SMOKE DETECTOR WITH NO DEFECTS NOTED,SDR RAIA2008122900005Power Supply · dischargedDURING PRE FLIGHT INSPECTION, THE EMERGENCY LIGHTS AT THE RIGHT AND LEFT OVERWING EXITS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY LIGHT POWER SUPPLY FOR THESE LIGHTS AND PERFORMED A OPERATIONAL CHECK OF THE EMERGENCY LIGHTINSDR CHQA200800262Smoke Detector · malfunctionedDURING TAXI THE CREW RECEIVED A BAGGAGE COMPARTMENT SMOKE INDICATION. THE CREW DISCHARGED THE FIRE EXTINGUISHERS FOR THE BAGGAGE COMPARTMENT AND RETURNED TO THE GATE WITHOUT INCIDENT. THE SYSTEMS AND THE BAGGAGE COMPARTMENT WERE THEN DEFERRED. MAINTENANCE LSDR RAIA2008122900004Control Panel · faultyDURING THE PRE FLIGHT INSPECTION, IT WAS FOUND THAT THE EMERGENCY LIGHTS WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACE THE FLIGHT ATTENDANT FORWARD CONTROL PANEL IAW AMM PROCEDURES. THE EMERGENCY LIGHTS FUNCTIONED PROPERLY AFTERWARDS.SDR C2XA08CL137Control Unit · faultyCLE FLT 2345 - THE CREW REPORTED A PITCH TRIM MAIN INOP MESSAGE IN FLIGHT. THE CREW RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE HORIZONTAL STAB CONTROL UNIT. OPERATIONAL CHECKS WERE GOOD.SDR FDKA2008122600325Light · malfunctionedFRL FLT 6207 ROC-JFK. ROW 12A EMERGENCY EXIT LIGHT INOP. DE-POWERED AND RE-POWERED AIRCRAFT OPS CK NORMAL.SDR FDKA2008122600324Inverter · malfunctionedFRL FLT 6289 JFK-PHL. OVERHEAD EMERG LIGHTS INOP. RESET THE INVERTER OPS CK GOOD.SDR SIMA200900902Control Unit · malfunctionedON FLIGHT 4345, CREW REPORTED UPON GEAR EXTENSION THEY RECEIVED 2 EICAS MESSAGES 1 FOR INBD BRAKES INOPERATIVE AND 1 FOR OTBD BRAKES INOPERATIVE. THEY RECYCLED GEAR WITH NO HELP. CREW DECLARED EMERGENCY AND LANDED USING THRUST REVERSERS. BRAKES APPEARED TO WSDR SIMA200836403Control Unit · malfunctionedON FLIGHT 4345, CREW REPORTED AFTER LANDING UPON GEAR EXTENSION THEY GOT 2 EICAS MESSAGES 1 FOR INBOARD BRAKES INOP AND 1 FOR OUTBOARD BRAKES INOPERATIVE. THEY RECYCLED GEAR WITH NO HELP. DECLARED EMERGENCY AND LANDED USING THRUST REVERSERS BRAKES APPEARED TSDR FDKA2008122500323Roller · lack of lubeFRL FLT 6193 PWM-JFK. MAIN DOOR HARD TO OPEN. MX LUBED DOOR ROLLERS AND SEAL OPS CHECK GOOD.SDR CHQA200800257Sensor · malfunctionedIN FLIGHT THE CREW RECEIVED A WINDSHIELD HEAT FAIL MESSAGE WHEN TURNING ON THE WINDSHIELD HEAT ON INITIAL DESCENT AT HIGHER ALTITUDES. MAINTENANCE CHANGED THE HEAT SENSOR LEADS FROM 3 AND 4 TO LEADS 5 AND 6 AND ALL OPERATIONAL CHECKS ARE GOOD.SDR CHQA200800255Light · inoperativeCREW REPORTED A SMOKE SMELL FROM EMERGENCY ROW AROUND SEAT 10A. THE FLIGHT DIVERTED TO LEX AND LANDED WITHOUT INCIDENT. FOUND SIDEWALL LIGHT AT 10A INOPERATIVE AND DEFERRED THE LIGHT. THE LIGHT WAS LATER RELAMPED, CLEARING THE MEL AND NO OTHER DEFECTS WERE SDR C2XA08CL136Circuit Breaker · burnedCLE FLT 2031 - THE CREW REPORTED A HOT ELECTRONICS’ SMELL COMING FROM THE CLOSET AREA. MAINTENANCE INSPECTED AND REPLACED CB0059. OPERATIONAL CHECKS WERE GOOD.SDR C2XA08CL135Controller · faultyCLE FLIGHT 2150 - THE CREW REPORTED THE AIRCRAFT WOULD NOT PRESSURIZE ON CLIMBOUT. THE AIRCRAFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE DIGITAL CONTROLLER. OPERATIONAL CHECKS WERE GOOD.SDR C2XA08IA273Smoke Detector · malfunctionedIAH - FLIGHT 2406, THE CREW REPORTED A LAV SMOKE INDICATION ON T/O FROM DAL. THE SYSTEM WAS RESET SUCCESSFULLY PER THE QRH, AND THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE LAV SMOKE DETECTOR, OPERATIONALLY TESTED WITH NOSDR RAIA2008122900001Thermostat · inoperativeCREW RECEIVED A BLEED 2 OVERTEMP MESSAGE ON THE EICAS. MAINTENANCE REMOVED AND REPLACED THE NR 2 THERMOSTAT. SYSTEM OPS CHECKED GOOD.
Back to Embraer EMB-145LR