Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CHQA200800254Inverter · inoperativeDURING INSPECTION THE EMERGENCY FLOOR STRIP LIGHTING FROM ROWS 12 TO 19 WERE FOUND TO BE INOP. THE NR 6 EMERGENCY LIGHT INVERTER WAS REPLACED AND THE SYSTEM OPERATED NORMALLY.SDR SIMA200836402Altimeter · malfunctionedON FLIGHT 3474, CREW REPORTED AT 300 FEET AGL THEY GOT AURAL GPWS WARNING AND LANDING GEAR WOULD NOT COME DOWN WITH GEAR TOO LOW. WITH GEAR DOWN AND CONFIGURED CORRECTLY CREW DID A GO AROUND AND RECYCLED GEAR. TOWER CONFIRMED GEAR DOWN. REQUESTED CFR AND LANSDR FDKA2008122200322Battery · dischargedFRL FLT 6208 CVG. LT AND RT AFT EXTERNAL LIGHTS OUT. MX REMOVED AND REPLACED NR 4 BATTERY OPS GOOD.SDR FDKA2008122200321Battery · dischargedFRL FLT 6172 IAD. LT AND RT EXTERNAL EMERGENCY LIGHTS OUT. MX REMOVED AND REPLACED BATTERY AND BATTERY CHARGER NR 4.SDR FDKA2008122100320Handle · dirtyFRL FLT 6190 CVG-CAE. MAIN CABIN DOOR INNER DOOR HANDLE HARD TO LOCK, AND DOOR HARD TO CLOSE. MX CLEANED AND LUBED, OPS CHECKED GOOD.SDR C2XA08IA274Unknown · odorIAH - FLIGHT 2883 THE CREW REPORTED A PITOT 3 HEAT INOP MESSAGE ON EICAS WITH A BURNT ELECTRICAL SMELL COMING FROM THE F/O'S SEATING AREA. IAH MAINTENANCE INSPECTED THE AIRCRAFT, OPERATIONALLY TESTED THE PITOT HEAT ALL WITH NO DEFECTS OR ODORS FOUND, AND THE SDR C2XA08IA260Smoke Warning · malfunctionedFLIGHT 2220 SHV-IAH - THE CREW REPORTED A MOMENTARY LAVATORY SMOKE WARNING DURING CRUISE. NO SMOKE CONDITIONS WERE NOTED AT THAT POINT AND THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT. MAINTENANCE PERFORMED ENGINE GROUND RUNS AND COULD NOT DUPLICATE THE CONDISDR RAIA2008122400001Duct · looseCREW RECEIVED A NR 1 BLEED LEAK MESSAGE ON THE EICAS. MAINTENANCE INSPECTED THE AIRCRAFT AND FOUND THE NR 1 FAN AIR DUCT TO BE LOOSE. THE DUCT WAS RE-SECURED AND THE SYSTEM OPS CHECKED GOOD.SDR CHQA200800253Battery Pack · dischargedDURING INSPECTION THE OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. THE NR 4 EMERGENCY LIGHT BATTERY PACK WAS REPLACED AND THE EMERGENCY LIGHTS OPERATED NORMALLY.SDR CHQA200800252Wire Harness · openFLIGHT 5936, CLE TO BDL. AFTER TAKEOFF THE FLIGHT CREW RECEIVED A LANDING GEAR AIR/GROUND FAIL MESSAGE ON EICAS AND THE LANDING GEAR WOULD NOT RETRACT. THE FLIGHT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE REPORTED CMC MESSAGES OF LGEU FAIL ANSDR CHQA200800251Proximity Switch · dirtyFLIGHT 7794, YYZ TO IAD. AFTER TAKEOFF WHEN THE LANDING GEAR WAS SELECTED TO UP THE FLIGHT CREW RECEIVED A LANDING GEAR AIR/GROUND FAIL MESSAGE ON EICAS AND THE LANDING GEAR WOULD NOT RETRACT. THE QRH WAS FOLLOWED AND THE AIRCRAFT RETURNED TO YYZ AND LANDED SDR FDKA2008122000319Light · malfunctionedFRL FLT 6208 CVG-JFK. OVERHEAD EMERG LIGHT ROW 12 INOP. MX RESET SYSTEM, OPS GOOD.SDR FDKA2008122000318Jumper · looseFRL FLT 6228 JFK. EMERGENCY FLOOR LIGHT STRIP OUT AT ROW 12. MX RESECURED JUMPER, OPS CHECKED GOOD.SDR C2XA08SH164Inlet · corrodedVARIOUS BOLTHOLES ON THE LT ENG AIR INLET CORRODED. REPAIRED BOLT HOLE ON LT ENG AIR INLET IAW EC 5420-01179. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA08SH163Floor Support · corrodedCENTER OMEGA BEAM HAS CORROSION IN RADIUS AT FR 20. CENTER OMEGA BEAM WAS REPAIRED IAW SRM 53-21-10. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA08IA262Inverter · faultyDURING SCHEDULED MAINTENANCE THE FORWARD OVERWING EXIT LOCATOR SIGN WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NR 6 INVERTER, OPERATIONALLY TESTED THE LIGHTING SYSTEM AND CLEARED THE DISCREPANCY.SDR RAIA2008122300002Light · inoperativeCREW REPORTED THAT 1ST WINDOW WASH LIGHT AT SEAT 1A WAS OUT AND THAT THERE WAS A SMELL OF HOT ELECTRICS. MAINTENANCE DEFERRED THE WINDOW WASH LIGHT AS PER MEL PROCEDURES.SDR FDKA2008121800317Door · lack of lubeFRL FLT 6271 CVG-IND. MAIN CABIN DOOR HARD TO OPEN. MX CLEANED AND LUBED THE DOOR.SDR C2XA08SH162Shroud · corrodedSHV DURING C-CHECK LT AILERON LOWER SHROUD HAD CORRODED BONDING PLATE. MX REPAIRED LT LOWER AILERON SHROUD IAW EC 5750-01315 (E). THE ACFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA08SH161Nut Plate · corrodedSHV DURING C-CHECK SERVICE DOOR LOWER NUTPLATE HOLES HAD CORROSION. MX REPAIRED SERVICE DOOR LOWER NUTPLATE HOLES BY REMOVING CORROSION AND FINDING SERVICE DOOR LOWER NUT PLATE HOLES TO BE WITHIN LIMITS IAW EMB SRM 51-10-03 AND EC 5210-01154. MX THEN TREATEDSDR C2XA08SH160Shroud · corrodedSHV DURING C-CHECK RT AILERON LOWER SHROUD HAD CORRODED BONDING PLATE. MX REPAIRED RT AILERON LWR SHROUD IAW EC 5750-01315 (E). THE ACFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA08SH159Plate · corrodedSHV DURING C-CHECK RT AILERON UPPER SHROUD HAD CORRODED BONDING PLATE. MX REPAIRED RT UPPER AILERON SHROUD IAW EC 5750-01315 (E). THE ACFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA08SH158Panel · corrodedSHV DURING C-CHECK PANEL 191EL WAS FOUND TO HAVE CORRODED BONDING PLATES. MX R&R BONDING PLATES ON PANEL 191EL IAW EC 5750-01315 REV "E". THE ACFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA08RI182Clamp · deformedFLIGHT 2775 - EWR - FLIGHT CREW REPORTED ENG NR 1 BLEED LEAK INDICATION ON EICAS IN FLIGHT. CREW PERFORMED AIR RETURN AND LANDED UNEVENTFULLY. EWR MX R&R BLEED V-CLAMP AND PERFORMED OPX CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR FDKA2008121700316Unknown · odorFRL FLT 6209 JFK-IAD. STRONG FUEL ODOR AFTER APU START. MX COULD NOT DUPLICATE AND FOUND NO FUEL LEAKS.SDR C2XA08CL134Thermostat · faultyCLE FLIGHT NR 2293 THE CREW REPORTED A BLEED 1 OVERTEMP MSG ON CLIMB IN ICING CONDITIONS. THE ACFT RETURNED TO CLE AND LANDED WITHOUT FURTHER INCIDENT. MX INSPECTED AND REPLACED THE NR 1 FAN AIR VALVE CONTROL THERMOSTAT. OPS CHECKS WERE GOOD.SDR SIMA200835402Engine · smokeON FLIGHT 3598, ON TAKEOFF CREW REPORTED SMOKE IN CABIN. CREW ABORTED TAKEOFF AND RETURNED TO BLOCK. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED LEFT ENGINE. OPERATION CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR CHQA200800250Battery Pack · dischargedDURING INSPECTION BOTH THE LEFT AND RIGHT OVERWING EMERGENCY LIGHTS WERE INOP. THE NR 4 EMERGENCY LIGHT BATTERY PACK WAS REPLACED AND THE SYSTEM OPERATED NORMALLY.SDR C2XA08IA255Light · malfunctionedIAH - DURING A-CK INSPECTION THE EMERGENCY LIGHT STRIPS BETWEEN ROWS 8 & 9 WERE FOUND TO BE INOPERATIVE. MX INSPECTED THE LIGHTING SYSTEM, OPS TESTED WITH NO DEFECTS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICESDR CHQA200800249Fire Detector · malfunctionedFLIGHT 5938, STL TO CLE - THE FLIGHT CREW RECEIVED A BAGGAGE SMOKE MESSAGE DURING CRUISE. THE QRH WAS FOLLOWED AND BOTH CARGO COMPARTMENT FIRE BOTTLES WERE DISCHARGED. THE ACFT LANDED WITHOUT INCIDENT IN IND. THE CARGO COMPARTMENT WAS INSPECTED WITH NO SIGNSDR C2XA08RI180Switch · inoperativeFLIGHT 2306 - EWR - DURING CLIMBING FLIGHT CREW REPORTED THE FOLLOWING MSGS ON EICAS: PACK 2 CLSD AND BLD 2 CLSD. CREW RESET THE SYSTEM BUT FAILED AGAIN AND WHEN TRIED AN ANTI ICE TEST GOT BLD 2 FAIL MSG. CREW PERFORMED AIR RETURN AND LANDED UNEVENTFULLY. MXSDR C2XA08RI179Bleed Valve · inoperativeFLIGHT 2306 EWR DURING CLIMBING FLIGHT CREW REPORTED THE FOLLOWING MSGS ON EICAS: PACK 2 CLSD AND BLD 2 CLSD. CREW RESET THE SYSTEM BUT FAILED AGAIN AND WHEN TRIED AN ANTI ICE TEST GOT BLD 2 FAIL MSG. CREW PERFORMED AIR RETURN AND LANDED UNEVENTFULLY. EWR MXSDR C2XA08CL131Valve · faultyCLE FLIGHT NR 2344 THE CREW REPORTED A BLEED 2 OVERTEMP WARNING WITH THE ANTI-ICE SYSTEM TURNED ON. MSG CLEARED WITH ANTI-ICE OFF. THE ACFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT.SDR RAIA2008121500005Mechanism · dirtyPASSENGER DOOR DIFFICULT TO OPEN. MAINTENANCE CLEANED AND LUBED THE PASSENGER OPERATING MECHANISM. OPS CHECKED GOOD.SDR RAIA2008121500004Handle · dirtyPASSENGER DOOR DIFFICULT TO OPERATE. MAINTENANCE CLEANED AND LUBED THE PASSENGER DOOR HANDLE. OPS CHECKED GOOD.SDR FDKA2008121400313Light · inoperativeFRL FLT 6274 JFK - RT EMERGENCY EXIT MARKER NOT ILLUMINATING. MX RELAMPED, OPS GOOD.SDR FDKA2008121400312Battery · dischargedFRL FLT 6260 PIT - AC EMERGENCY LIGHTS WILL NOT ILLUMINATE. MX REMOVED AND REPLACED EMERGENCY BATTERIES.SDR FDKA2008121300314Flap · failedFRL FLT 6254 IND-JFK - FLAPS FAIL IN FLIGHT, EMERGENCY DECLARED. AC REQUIRED ADDITIONAL RIGGING, OPS CHECK GOOD.SDR FDKA2008121300311Battery · dischargedFRL FLT 6254 IND - EMERGENCY EXIT LOCATOR AND OVERWING IDENTIFIERS OUT ON LT AND RT SIDE OF CABIN. MX ALLOWED EMERGENCY BATTERIES TO CHARGE. OPS CHECKED GOOD.SDR CHQA200800246Valve · false indicationIN FLIGHT THE CREW RECEIVED THE BRAKE ON INDICATION LIGHT. THEY PROCEEDED TO THE FINAL DESTINATION AND LANDED WITHOUT INCIDENT. THE PARKING BRAKE VALVE WAS REMOVED AND REPLACED IAW AMM 32-44-01 AND OPERATIONALLY CHECKED OK.SDR RAIA2008121500002Connector · dirtyTHE CREW RECEIVED A FLAP FAIL MESSAGE ON THE EICAS. MAINTENANCE CLEANED AND RE-SECURED THE CONNECTOR TO THE FECU, INSPECTED WIRES, AND PERFORMED AN OPERATIONAL CHECK OF THE FLAP SYSTEM WITH NO DEFECTS NOTED.SDR CHQA200800244Pressure Switch · false indicationFLIGHT 6123, ORF TO CVG - DURING CRUISE FLIGHT THE CREW REPORTED THAT THE BRAKE ON LIGHT FOR THE EMERGENCY BRAKE ILLUMINATED AND STAYED ON FOR THE DURATION OF THE FLIGHT. THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE EMERGENCY PARKING BRAKE SDR C2XA08CL132Wire · frayedCLE FLIGHT NR 2118 THE CREW REPORTED A STAB A/I FAIL MSG IN CLIMBOUT FROM CLE. THE CREW COMPLETED THE QRH INSTRUCTIONS AND MSG WAS STILL THERE. THE ACFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MX INSPECTED AND REPLACED THE STAB ANTI/ICE VALVE AND REPAIRESDR FDKA2008121000310Battery · dischargedFRL FLT 6222 CLT - EMERGENCY LIGHTS DEAD. MX REPLACED 4 BATTERY PACKS.SDR SIMA200835001Heater · odorON FLIGHT 3956, CREW REPORTED ELECTRICAL BURNING ODOR AT GATE FROM COCKPIT. AIRCRAFT REMOVED FROM SERVICE. OPERATED ELECTRICAL SYSTEM AND WINDSHIELD HEAT IAW AMM 30-43-00. COULD NOT DUPLICATE. AIRCRAFT RETURNED TO SERVICE.SDR C2XA08CL128Computer · faultyCLE FLIGHT NR 2475 THE CREW REPORTED THEY LOST THE NR 1 ATTITUDE AND HEADING COMPUTER (AHRS) IN FLIGHT. MX INSPECTED AND REPLACED THE CAPTAINS AHRS COMPUTER AND OPS CHECKS WERE GOOD.SDR CHQA200800241Inverter · inoperativeEMERGENCY FLOOR STRIP LIGHTS 2 AND 3 WERE INOPERATIVE DURING TEST. THE NR 3 INVERTER WAS REPLACED IAW EMB 145 AMM 33-50-11 AND THE SYSTEMS CHECKED OPERATIONAL.SDR SIMA200834501Skin · gougedON A IMBV INSPECTION REPAIRED A DEFERRED DISCREPANCY. A GOUGE AND DENT ON FUSELAGE SKIN BETWEEN FRAMES 21 AND 22 AND BETWEEN STRINGERS 17L AND 18L. PERFORMED A CUT OUT OF THE FUSELAGE SKIN TO REMOVE THE DAMAGE. FABRICATED. A FILLER AND REPAIR DOUBLER. MARKSDR SIMA200834502Sill · corrodedDURING A IMBV INSPECTION A PREVIOUS REWORKED AREA ON THE SERVICE DOOR CUT OUT LOWER CENTER SILL WAS FOUND CORRODED. BLENDED THE CORRODED AREAS, CLEANED AND PERFORMED NDT INSPECTIONS. APPLIED EPOXY PRIMER TO BLENDED AREAS. FABRICATED FORWARD DOUBLER, CLEANEDSDR RAIA2008120800001Connector · brokenEMERGENCY EXIT LIGHT AT ROW 3BC INOPERATIVE. MAINTENANCE SPLICED IN A NEW CONNECTOR FOR THE LIGHT. OPERATIONAL CHECK WAS GOOD.
Back to Embraer EMB-145LR