SDR RAIA2008120500002Light · inoperativeEMERGENCY FLOOD LIGHT AT AISLE IS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE DEFECTIVE BULB. OPS CHECKED GOOD.SDR SIMA200834306Channel · corrodedDURING A IMBV INSPECTION, THE BAGGAGE DOOR LOWER SILL WAS FOUND TO BE CORRODED. REMOVED CORRODED DOOR SILL. POSITIONED NEW SILL AND DRILLED, CLEANED, ALODINED AND PRIMED NEW SILL AND SILL AREA. REPAIR DONE IAW EMBRAER SRM (SRM EMB 145/1142 REV 40) CHAPTER 5SDR C2XA08CL127Relay · faultyCLE - FLIGHT 2006 - THE CREW REPORTED A WING ANTI-ICE AND A PACK 1 VALVE FAIL MESSAGE ON THE EICAS DURING CLIMBOUT. THE AIRCRAFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NR 1 PACK VALVE AND RELAY KO187. OPERATIONALSDR C2XA08IA249Inverter · inoperativeIAH - DURING MAINTENANCE INSPECTION SEVERAL EMERGENCY LIGHTS IN THE CABIN WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE EMERGENCY LIGHT INVERTER, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TSDR SIMA200834308Channel · corrodedDURING CPCP INSPECTION, FOUND RIGHT OMEGA BEAM CORRODED BETWEEN FRAMES 24 AND 25. REPAIRED OMEGA BEAM IAW EMB SRM 53-00-10. AIRCRAFT WAS RETURNED TO SERVICE.SDR SIMA200834307Beam · corrodedDURING INSPECTION, FOUND CARGO DOOR SILL CORRODED. REPLACED SILL IAW EMBRAER SRM 51-40-02. AIRCRAFT WAS RETURNED TO SERVICE.SDR SIMA200834305Channel · corrodedDURING A IMBV INSPECTION, THE LEFT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 25. CUTOUT A SECTION OF BEAM TO REMOVE THE CORROSION. FABRICATED FILLER AND TWO SHIMS. DRILLED PARTS, CLEANED, ALODINED AND PRIMED REPAIR PARTS. REPAIR DONE IAW EMB SRM (SRM ESDR FDKA2008120300308Seal · lack of lubeFRL FLT 6273 CVG-ROC. RT OVERWING EXIT DOOR SQUEALS IN FLIGHT. MX LUBED DOOR SEAL. LEAK CHECKED GOOD.SDR FDKA2008120300307Fire Bottle · inoperativeFRL FLT 6269 BHM-CVG. CARGO EXTINGUISH BOTTLE INOP DURING FIRE TEST. MX REMOVED AND REPLACED CARGO FIRE BOTTLES.SDR FDKA2008120300306Smoke Detector · inoperativeFRL FLT 6176 CVG-PHL. SMOKE DETECTOR WILL NOT TEST. MX REMOVED AND REPLACED NR 2 SMOKE DETECTOR, OPS CHECK GOOD.SDR FDKA2008120300305Handle · out of adjustFRL FLT 6268 IAD. MAIN CABIN DOOR INNER HANDLE CATCHES ON DOOR TRIM. MX ADJUSTED HANDLE, OPS CHECKED GOOD.SDR CHQA200800236Light · malfunctionedTHE FLIGHT ATTENDANT STATES THAT THE EMERGENCY EXIT ROW ILLUMINATION LIGHT IS INOPERATIVE. THE LIGHT OPERATIONALLY CHECKS GOOD IAW AMM 33-50-00.SDR CHQA200800235Battery Pack · dischargedTHE OVERWING EMERGENCY LIGHTS DO NOT OPERATE WHEN TESTED. THE EMERGENCY BATTERY WAS REPLACED IAW EMB 145 AMM 33-50-04 AND THE EMERGENCY LIGHTS OPERATED NORMALLY.SDR FDKA2008120200304Charger · inoperativeFRL FLT 6189 JFK-RIC. ROW 12 LT EMERGENCY EXIT SIGN INOP. MX REMOVED AND REPLACED NR 3 BATTERY CHARGER, OPS CHECK GOOD.SDR FDKA2008120200303Hinge · lack of lubeFRL FLT 6194 CVG-IAD. MAIN PAX DOOR HARD TO OPEN. MX LUBED HINGE POINTS, OPS CHECK GOOD.SDR C2XA08SHAttach Fitting · damagedSHV - DURING C-CHECK RUDDER 1 UPPER ACTUATOR ATTACHMENT LOWER HINGE UPPER HAT BUSHING MIGRATED.SDR SIMA200834304Sill · corrodedDURING A IMBV INSPECTION, THE BAGGAGE DOOR LOWER SILL WAS FOUND TO BE CORRODED. REMOVED CORRODED DOOR SILL. POSITIONED NEW SILL AND DRILLED. CLEANED, ALODINED AND PRIMED NEW SILL AND SILL AREA. REPAIR DONE IAW EMBRAER SRM (SRM EMB 145/1142 REV 40) CHAPTER SDR SIMA200834301Wheel · separatedON FLIGHT 3992 AFTER TAKEOFF DURING GEAR RETRACTION CREW RECEIVED A L/G DISAGREE AND RIGHT L/G RED. CREW RAN CHECKLIST AND NOTED NORMAL ONLY WHEN GEAR DOWN. CREW RETURNED FOR LANDING AND WAS ADVISED BY CONTROL TOWER THAT THE NR 3 TIRE WAS BLOWN. AFTER LANDISDR RAIA2008120300001O-Ring · leakingCREW RECEIVED A BLEED 2 LEAK MESSAGE ON THE EICAS DURING CLIMB. MAINTENANCE REMOVED AND REPLACED LEAKING O-RINGS IN THE BLEED DUCT SYSTEM. OPS CHECKED GOOD.SDR SIMA200833802Battery · dischargedON FLIGHT 3570 CREW REPORTED ON PREFLIGHT FORWARD ZONE EMERGENCY LIGHTS NOT ON OVER FLIGHT ATTENDANT SEAT EXIT SIGN BELOW COCKPIT FLOOR, AND EXIT SIGN-CEILING GALLEY EXIT SIGN. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED NR 1 BATTERY PACK IAW EMB 145SDR C2XA08IA250O-Ring · failedCVG - FLIGHT 2770, DURING CLIMBOUT THE CREW REPORTED A NR 1 BLEED LEAK. THE AIRCRAFT RETURNED TO CVG WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE BLEED O-RINGS IN THE AFT CABIN AND FORWARD CARGO, OPERATIONALLY CHECKED WITH NO DEFECTSDR FDKA2008113000301Clamp · looseFDM FLT 6231 PHL-RON. EMERGENCY DECLARED AND AIRCRAFT DIVERTED DUE TO BLEED 1 LEAK MESSAGE. MX FOUND LOOSE CLAMP AT THE BLEED VALVE.SDR CHQA200800234Wire · brokenDURING INSPECTION, THE RIGHT OVERWING EMERGENCY LIGHT WAS FOUND TO BE INOP. MAINTENANCE FOUND THE WIRE W102-8502-22 WIRE BROKEN AT ROW 13. THE WIRE WAS REPAIRED AND PIN 63 WAS REPLACED IN CONNECTOR P1060.SDR RAIA2008120100002Duct · looseDURING CLIMB FROM TAKEOFF, CREW RECEIVED A BLEED NR 1 AND NR 2 LEAK MESSAGE ON THE EICAS. MAINTENANCE RESECURED LOOSE A NR 2 BLEED LINE DUCT UNDER THE CARGO FLOOR. BLEED SYSTEM, OPS CHECKED GOOD.SDR C2XA08CL125Actuator · faultyCLE - FLIGHT 2775 - THE CREW REPORTED A LANDING GEAR LEVER DISAGREE MESSAGE ON THE EICAS AFTER SELECTING GEAR DOWN. THE MESSAGE CLEARED IMMEDIATELY AND NO OTHER INDICATIONS WERE NOTICED. MAINTENANCE INSPECTED AND REPLACED THE RIGHT NOSE GEAR DOOR ACTUATOR. SDR SIMA200834303Sill · corrodedDURING A IMBV INSPECTION, THE BAGGAGE DOOR LOWER SILL WAS FOUND TO BE CORRODED. REMOVED CORRODED DOOR SILL. POSITIONED NEW SILL AND DRILLED FOR FASTENERS. CLEANED ALODINED AND PRIMED NEW SILL AND INSTALLED. REPAIR DONE IAW EMB SRM (SRM EMB 145/1142 REV 40)SDR SIMA200833801A/C Pack · smokeON FLIGHT 3488, CREW REPORTED WITH APU RUNNING AND NR 2 PACK OPERATING SMOKE IN CABIN AND PACK 2 OVERHEAT. MEL ISSUEDSDR CHQA200800233Battery Pack · inoperativeDURING INSPECTION THE OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOP. THE NR 4 EMERGENCY POWER SUPPLY WAS REPLACED AND THE OVERWING EMERGENCY LIGHTS OPERATED NORMALLY.SDR FDKA2008112800300Battery Pack · dischargedFRL FLT 6167 CVG-IND - AFT CEILING EXIT LOCATOR, FWD SIDE OUT. MX REMOVED AND REPLACED NR 3 AND NR 4 BATTERY PACKS.SDR SIMA200833603Unknown · odorON FLIGHT 3389 CREW REPORTED SMOKE IN THE COCKPIT WITH BURNING ELECTRICAL ODOR AT GATE WITH PASSENGERS LOADED. AIRCRAFT REMOVED FROM SERVICE. PERFORMED ABNORMAL ODOR/SMOKE CHECK, NO DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE.SDR C2XA08CL124Fire Bottle · faultyEWR - FLIGHT 2400 - THE CREW REPORTED A ENGINE 1/2 EXTBTL A INOP MESSAGE ON THE EICAS INFLIGHT. THE AIRCRAFT DIVERTED INTO CLE AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE ENGINE NR 1 FIRE BOTTLE A. OPERATIONAL CHECKS WERE GOOSDR C2XA08CL123Engine · faultyCLE - FLIGHT 2311 - THE CREW REPORTED AT FL320 THE NR 2 ENGINE ITT STARTED INCREASING SLOWLY TO 860 WITHOUT FULL THRUST. ASSENTING AT 91PERCENT N2 THE ENGINES HAD A 30 DEGREE DIFFERENCE. THE FUEL FLOW WAS ALSO NOTED TO BE 30 PPH HIGH. MAINTENANCE INSPECTED ASDR C2XA08IA244Battery Pack · dischargedIAH - FLIGHT 2998, THE CREW REPORTED EMERGENCY LIGHTS INOP ON THE BACK LEFT SIDE. MAINTENANCE REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT BATTERY, OPERATIONALLY CHECKED WITH NO DEFECTS. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA08TY137Fuse · blownRT & LT OVERWING EMERGENCY LIGHTS INOP. REMOVED AND REPLACED NR 4 EMERGENCY LIGHT BATTERY TRAY FUSE IAW RADIANT POWERCORP VCMM 25-60-03. OPS CHECK GOOD AND AIRCRAFT RELEASE FOR SERVICE.SDR SIMA200832901Display · malfunctionedON FLIGHT 4286, DURING DESCENT CREW RECEIVED A PFD FAILED MESSAGE FOLLOWED BY SLIGHT ELECTRICAL BURNING ODOR. CREW PULLED PFD NR 1 CB AND ODOR SLOWLY EXTINGUISHED. ACFT REMOVED FROM SERVICE, ISSUED MEL 34-01. REMOVED AND REPLACE NR 1 PFD IAW EMB-145 MM 34-2SDR C2XA08TY134Apu · malfunctionedBNA - MX WAS IN THE COCKPIT OF THE A/C TROUBLESHOOTING THE APU, AND RECEIVED AN APU FIRE MESSAGE AND DISCHARGED THE FIRE BOTTLE. THE APU FIRE BOTTLE WAS REMOVED AND REPLACED IAW EMB 145 AMM 26-22-01 AND OPS CHECKED GOOD. THE APU WAS REMOVED AND REPLACED IAW SDR FDKA2008112300299Door · lack of lubeFRL FLT 6283 CVG-DAY - GALLEY DOOR DIFFICULT TO CLOSE. MX CLEANED AND LUBED DOOR, OPS CHECKED GOOD.SDR CHQA200800230Smoke Detector · false activationFLIGHT 6159, MKE TO CVG - DURING TAKEOFF CLIMB AT 1,000 FT, THE FLIGHT CREW RECEIVED A LAV SMOKE EICAS WARNING. THE QRH WAS FOLLOWED AND THE AIRCRAFT RETURNED TO LAND. THE FLIGHT ATTENDANT CONFIRMED THAT THERE WAS NO SMOKE OR FIRE. MAINTENANCE RAN THE ENGINSDR C2XA08IA241Acm · seizedRSW - FLIGHT 3146 - THE FLIGHT ATTENDANT REPORTED SMOKE IN THE CABIN AND PASSENGERS REPORTED HEARING A LOUD POPPING SOUND WHILE CLIMBING THROUGH 14,000 FEET. THE CREW FOLLOWED THE QRH PROCEDURES, AND THE AIRCRAFT RETURNED TO RSW WHERE IT LANDED WITHOUT INCIDESDR CHQA200800229Generator · failedFLIGHT 7875, CMH TO IAD - AFTER TAKEOFF, THE FLIGHT CREW RECEIVED A GENERATOR NR 2 BEARING FAIL MESSAGE ON EICAS. THE FLIGHT RETURNED TO CMH AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE GENERATOR NR 2 HARNESS W402 BUT THE MESSAGE WOULD INTERMITTENTLSDR C2XA08CL122Fadec · faultyCLE FLIGHT 2733 - THE CREW REPORTED, LOST NR 1 ENGINE INDICATION SEVERAL TIMES. THE CREW PERFORMED PROCEDURES FROM THE CFM. MAINTENANCE INSPECTED AND REPLACED THE 1B FADEC. OPERATIONAL CHECKS WERE GOOD.SDR RAIA2008112400001Thermal Switch · faultyDURING CRUISE, CREW RECEIVED A HYDRAULIC SYSTEM 1 OVERHEAT MESSAGE ON THE EICAS. MAINTENANCE REMOVED AND REPLACED THE NR 1 SYSTEM HYDRAULIC THERMAL SWITCH. SYSTEM OPS CHECKED GOOD.SDR FDKA200811298Light · inoperativeFRL FLT 6265 JFK-RIC - AFT MOST FLOOR ESCAPE PATH LIGHTS INOPERATIVE. MX REMOVED AND REPLACED FLOOR STRIP, OPS CHECKED GOOD.SDR C2XA08IA242Light · inoperativeMCI - DURING MAINTENANCE INSPECTION, THE LAST THREE AISLE PATH LIGHT STRIPS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY LIGHT STRIP JUST AFT OF ROW 12, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RSDR CHQA200800228Battery Pack · dischargedDURING INSPECTION MAINTENANCE FOUND THAT THE FLOOR EMERGENCY LIGHTS FROM SEATS 7A TO 12A WERE INOPERATIVE WHEN TESTED.SDR C2XA08CL121Hydraulic System · contaminatedMKE - FLIGHT 2948 - THE CREW REPORTED THE NR 1 HYDRAULIC SYSTEM FLUID SHOWED 1/4 LEVEL AFTER 43 MINUTES IN FLIGHT. THE SYSTEM WAS SERVICED PRIOR TO DEPARTURE FROM IAH. RECEIVED A HYD SYS 1 LOW QUANTITY ON FINAL APPROACH. EMERGENCY WAS DECLARED AND THE AIRCRSDR FDKA2008111600297Battery Pack · dischargedFRL FLT 6268 JFK-IAD - EMERGENCY LIGHTS INOP. MX REPLACED EMERGENCY BATTERY PACKS 2 AND 3. OPS CHECK GOOD.SDR FDKA2008111600296Strut · lowFRL FLT 6250 CLT-CVG - LANDING GEAR AIR GOUND FAIL. MX SERVICED NOSE STRUT AND OPS CHECKED GOOD.SDR FDKA2008111500295Windshield · crackedFDL FLT 6173 JFK-PIT - EMERGENCY DECLARED DUE TO LT WINDSHIELD SHATTERED. MX REMOVED AND REPLACED WINDSHIELD, OPS CHECKED GOOD.SDR C2XA08IA239Battery Pack · dischargedLRD - FLIGHT 2858, THE CREW REPORTED SEVERAL EMERGENCY LIGHTS WOULD NOT TEST. THE CREW CHARGED THE EMERGENCY LIGHT BATTERIES, OPERATIONALLY TESTED WITH NO DEFECTS. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
Back to Embraer EMB-145LR