Embraer EMB-145LR

Service difficulty reports · 36,875

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR MASA200500143Bracket · looseASH - CLT HAD A MAIN CABIN DOOR THAT WOULD NOT CLOSE. MAINTENANCE SECURED A BRACKET INSIDE THE DOOR ASSEMBLY. OPS CHECK GOOD.Feb 22, 2005 · N826MJ · Emb EMB145LR · Passenger/Crew DoorsSDR C2XA05SH012Floor Support · corrodedSHV - DURING C-CHECK CORROSION ON LT OMEGA BEAM I/B SIDE BETWEEN FR20 TO FR29. MAINTENANCE REMOVED THE DAMAGE AREA AND PERFORMED REPAIR IAW EMB SRM 53-21-10. THE AIRCRAFT WAS APPROVED FOR RETURNED TO SERVICE.Feb 22, 2005 · N22909 · Emb EMB145LR · Fuselage Miscellaneous StructureSDR MASA200500140Sign · inoperativeCLT - MKE, AISLE OVERHEAD EMERGENCY EXIT SIGN INOPERATIVE. MAINTENANCE TESTED LIGHT AND OPS CHECKED GOOD.Feb 21, 2005 · N826MJ · Emb EMB145LR · Emergency LightingSDR MASA200500139Sign · inoperativeCVG - CLT - AISLE OVERHEAD EMERGENCY EXIT SIGN INOPERATIVE. MAINTENANCE RESECURED THE CANNON PLUG.Feb 21, 2005 · N826MJ · Emb EMB145LR · Emergency LightingSDR MASA200500141Skin · erodedIN C-CHECK LEADING EDGE II ON RT WING IS ERODED OUT OF LIMITS. DAMAGE HAS BEEN BLENDED IAW SRM 57-40-00, REMAINING MATERIAL IS ACCEPTABLE IAW EMBRAER ENGINEERING DOCUMENT IC2005-145/0934.Feb 21, 2005 · N851MJ · Emb EMB145LR · Wing, Plate/SkinSDR SIMA200505605Floor Support · corrodedABI - A PREVIOUS REPAIR ON THE LEFT OMEGA BEAM AT FRAME 20 WAS FOUND CORRODED. REMOVED EXISTING REPAIR AND CLEANED THE AREA. FABRICATED A FILLER, PLATE, EXTERNAL ANGLE AND TWO SHIMS. REPAIR DONE IAW EMB 145 SRM, SRM EMB-145/1142 REV 28, CHAPTER 53-21-10, FIFeb 20, 2005 · N640AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR MASA200500137Battery Pack · inoperativeEMERGENCY FLOOR PATH LIGHTING STRIPS INOP. MAINTENANCE REPLACED THE NR 3 EMERGENCY LIGHTING BATTERY PACK.Feb 20, 2005 · N835MJ · Emb EMB145LR · Emergency LightingSDR MASA200500135Bulb · burned outCLT TO STL HAD THE 3RD CEILING EMERGENCY EXIT FLOOD LIGHT INOP. MAINTENANCE RELAMPED THE LIGHT AND OPS CHECKED GOOD. A/C DEPARTED WITHOUT FURTHER INCIDENT.Feb 20, 2005 · N855MJ · Emb EMB145LR · Emergency LightingSDR CHQA200500038Smoke Detector · false indicationAFTER TAKEOFF A LAV SMOKE INDICATION APPEARED ON EICAS. NO VISUAL SMOKE WAS NOTED. RETURNED TO THE FIELD. INSPECTED LAVATORY SMOKE DETECTOR AND PERFORMED SMOKE DETECTOR TEST IAW EMB 145 AMM 26-15-00. PERFORMED TAKEOFF POWER GROUND ENGINE RUNS. NO DEFECTS Feb 20, 2005 · N576RP · Emb EMB145LR · Smoke DetectionSDR CHQA200500037Lamp · burned outLEFT HAND FORWARD EMERGENCY EXIT LIGHT IS INOP. RELAMPED PER EMB 145 MM 33-50-10. OPS CHECK GOOD.Feb 20, 2005 · N262SK · Emb EMB145LR · Emergency LightingSDR C2XA05TY018Fitting · wornDURING A 4C INSPECTION THE HORIZONTAL TO VERTICAL STAB RT SPHERICAL BEARING HOUSING IN THE VERTICAL STABILIZER FITTING WAS FOUND WORN. MAINTENANCE REAMED THE RT SPHERICAL HOUSING, INSTALLED NEW INTERNAL AND EXTERNAL BUSHINGS, AND COMPLIED WITH A DIEHEDRAL ANDFeb 19, 2005 · N14952 · Emb EMB145LR · Horizontal Stabilizer StructureSDR C2XA05TY020Proximity Sensor · malfunctionedLANDING GEAR DISAGREE MESSAGE UPON ATTEMPTED RETRACTION OF L/G. ACFT RETURNED TO FIELD. MAINTENANCE REMOVED AND REPLACED THE NOSE LANDING GEAR PROXIMITY SENSOR. LANDING GEAR OPERATION CHECK SATISFACTORY. ACFT RETURNED TO SERVICE.Feb 18, 2005 · N16951 · Emb EMB145LR · Landing Gear Position and WarningSDR C2XA05TY019Lever · malfunctionedLANDING GEAR DISAGREE MESSAGE UPON ATTEMPTED RETRACTION OF L/G. ACFT RETURNED TO FIELD. MAINTENANCE REMOVED AND REPLACED THE LANDING GEAR SELECTOR LEVER AND THE NLG PROXIMITY SENSOR. LANDING GEAR OPERATION CHECK SATISFACTORY. ACFT RELEASED TO SERVICE.Feb 18, 2005 · N16951 · Emb EMB145LR · Landing Gear SelectorSDR CHQA200500036Warning Light · illuminatedFLIGHT 6300 MCO-FLL - DURING CLIMBOUT A LAV SMOKE MESSAGE APPEARED ON EICAS AND A SLIGHT HAZE WAS NOTED IN THE COCKPIT. THE AIRCRAFT RETURNED TO THE FIELD FOR AN UNEVENTFUL LANDING. MAINTENANCE PERFORMED ENGINE RUNS IAW EMB 145 RR AMM 71-00-01. PERFORMED LAFeb 17, 2005 · N576RP · Emb EMB145LR · Smoke DetectionSDR MASA200500123Rib · crackedIN C-CHECK EMPENNAGE INTERNAL RIB IS CRACKED AND IS BEING REPLACED IAW SRM 51-40-02.Feb 16, 2005 · N851MJ · Emb EMB145LR · Horizontal Stabilizer, Spar/RibSDR MASA200500121Light · intermittentASH - PHL AN OVERWING EXIT LIGHT SIGN INOP. MAINTENANCE CYCLED THE EMERGENCY EXIT LIGHT SWITCH AND COULD NOT DUPLICATE FAULT.Feb 16, 2005 · N853MJ · Emb EMB145LR · Emergency LightingSDR C2XA05IA028Fire Warning · false activationCLE - THE CREW REPORTED A MOMENTARY APU FIRE MASTER WARNING IN FLIGHT DURING START. THE AIRCRAFT LANDED AT CLE WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE APU, PERFORMED OPERATIONAL CHECKS WITH NO DEFECTS NOTED. THE AIRCRAFT WAS APPROVED FOR RETURN TO SFeb 15, 2005 · N12900 · Emb EMB145LR · Fire DetectionSDR MASA200500120Bracket · crackedIN C-CHECK, RT FLUX DETECTOR BRACKET IS CRACKED AND IS BEING REPAIRED IAW SRM 57-20-07.Feb 15, 2005 · N851MJ · Emb EMB145LR · Wing Miscellaneous StructureSDR MASA200500119Bracket · crackedIN C-CHECK, LT FLUX DETECTOR BRACKET IS CRACKED AND IS BEING REPAIRED IAW SRM 57-20-07.Feb 15, 2005 · N851MJ · Emb EMB145LR · Wing Miscellaneous StructureSDR MASA200500118Strap · corrodedIN C-CHECK, PLATE P/N 145-22461 IS CORRODED AND IS BEING REPLACED IAW SRM 51-40-02.Feb 15, 2005 · N851MJ · Emb EMB145LR · Fuselage Miscellaneous StructureSDR MASA200500117Profile · corrodedIN C-CHECK PROFILE P/N 145-21718-007 IS CORRODED AND IS BEING REPLACED IAW SRM 51-40-02.Feb 15, 2005 · N851MJ · Emb EMB145LR · Fuselage Miscellaneous StructureSDR MASA200500116Support Angle · corrodedIN C-CHECK, PAX DOOR ENTRANCE U-BEAM SUPPORT ANGLES ARE CORRODED AND WILL BE REPLACED IAW SRM 51-40-02.Feb 15, 2005 · N851MJ · Emb EMB145LR · Fuselage Miscellaneous StructureSDR C2XA05CL010Light · inoperativeCLE FLIGHT NR 2107, CREW REPORTED THAT THE GALLEY AND BULKHEAD EMERGENCY LIGHTS WERE INOP. MAINTENANCE PERFORMED AN OPERATIONAL CHECK OF THE EMERGENCY LIGHT SYSTEM, AND DID NOT FIND AND DEFECTS. SYSTEM OPERATIONALLY CHECKED GOOD.Feb 15, 2005 · N14960 · Emb EMB145LR · Emergency LightingSDR MASA200500114Connector · looseCLT TO BNA FWD CABIN FLOOR EMERGENCY EXIT LIGHT WILL NOT ILLUMINATE. MAINTENANCE SECURED ELECTRICAL CONNECTOR TO LIGHTING STRIP. NO FURTHER DEFECTS NOTED.Feb 14, 2005 · N828MJ · Emb EMB145LR · Emergency LightingSDR MASA200500113Bulb · burned outCLT TO PHF AFT OVERHEAD EMERGENCY EXIT LIGHT WILL NOT ILLUMINATE. MAINTENANCE REPLACED THE LIGHT. NO FURTHER DEFECTS NOTED.Feb 14, 2005 · N826MJ · Emb EMB145LR · Emergency LightingSDR C2XA05CL011Connector · shortedORD FLIGHT NR2758, CREW REPORTED THAT THE EMERGENCY LIGHTS WOULD NOT SHUTOFF. AIRCRAFT WAS FERRIED TO CLE WHERE MAINTENANCE REPLACED THE CONNECTOR AT THE NR 2 EMERGENCY BATTERY. ALL OPERATIONAL CHECKS WERE GOOD.Feb 14, 2005 · N16981 · Emb EMB145LR · Light System WiringSDR CHQA200500032Battery Pack · dischargedAFT OVERWING LEFT AND RIGHT AISLE FLOOR RUNNER EMERGENCY EXIT LIGHTS ARE INOP. REMOVED AND REPLACED NR 2 AFT EMERGENCY POWER SUPPLY IAW EMB 145 AMM 33-50-00. OPS CHECK GOOD.Feb 14, 2005 · N292SK · Emb EMB145LR · Emergency LightingSDR C2XA05CL008Inverter · inoperativeDURING ROUTINE MAINTENANCE, THE EMERGENCY LIGHT FLOOR STRIPS NR 6, 7, AND 8 WERE INOP. MAINTENANCE REPLACED THE NR 6 EMERGENCY LIGHT INVERTER. ALL OPERATIONAL CHECKS WERE GOOD.Feb 13, 2005 · N16571 · Emb EMB145LR · Emergency LightingSDR CHQA200500031Engine · contaminatedCLIMBING AT 10,000 FT A BURNING SMELL WAS NOTED IN THE COCKPIT. WITHIN A FEW SECONDS, THE SMELL GOT REALLY STRONG AND THE PILOT'S NOSE AND EYES BEGAN TO BURN. THE FLIGHT ATTENDANT AND PASSENGERS ALSO NOTICED THE SMELL. THE CREW CALLED ATC AND ATC DECLARED AFeb 13, 2005 · N258JQ · Emb EMB145LR · Air Distribution SystemSDR SIMA200504501Light · inoperativeRST - FLT 3986 - CREW REPORTED THE EMERGENCY AT COCKPIT STEP TO BE INOPERATIVE. MAINTENANCE REPLACED THE EXIT MARKING SIGN ASSEMBLY IAW EMB MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)Feb 12, 2005 · N681AE · Emb EMB145LR · Emergency LightingSDR MASA200500107Connector · looseASH - CLT FORWARD OVERHEAD EMERGENCY EXIT LIGHT WOULD NOT ILLUMINATE. MAINTENANCE SECURED CONNECTOR TO THE LIGHT ASSEMBLY. NO FURTHER DEFECTS NOTED.Feb 12, 2005 · N826MJ · Emb EMB145LR · Light System WiringSDR MASA200500103Light · malfunctionedASH - CLT TO CRW HAD 2 FLOOR EMERGENCY EXIT LIGHT STRIPS REPORTED TO BE INOP BY THE CREW. MAINTENANCE FOUND THE LIGHT STRIPS TO BE OPERATING NORMALLY, AND COULD NOT DUPLICATE THE DISCREPANCY. AIRCRAFT DEPARTED WITHOUT FURTHER INCIDENT.Feb 12, 2005 · N835MJ · Emb EMB145LR · Emergency LightingSDR MASA200500100Duct · unknownCLT TO BNA HAD THE NR 2 PACK PRODUCE A BURNING SMELL WHILE IN USE. MAINTENANCE PLACED THE PACK ON MEL. AIRCRAFT DEPARTED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED 3 DUCTS, OPS CHECKED GOOD. P/N 145-22273-401, 145-22277-403 AND 145-22285-401, ALL NON SFeb 11, 2005 · N860MJ · Emb EMB145LR · Air Distribution SystemSDR C2XA05IA026Charger · inoperativeMCI - DURING MAINTENANCE INSPECTION, THE AFT OVERWING EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER FOUR EMERGENCY LIGHT BATTERY CHARGER, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETFeb 11, 2005 · N14543 · Emb EMB145LR · Emergency LightingSDR MASA200500099Light · inoperativeON RON AND SCHEDULED FOR A ROUTINE CHECK INSPECTION, DURING THE WALK AROUND IT WAS DISCOVERED THAT THE LEFT HAND EXTERNAL OVERWING EMERGENCY LIGHT NOT ILLUMINATING. MAINTENANCE REPLACED THE LIGHT ASSEMBLY AFTER TROUBLESHOOTING. OPERATIONAL CHECK GOOD.Feb 11, 2005 · N826MJ · Emb EMB145LR · Emergency LightingSDR SIMA200504502Floor Support · corrodedABI - DURING AN IMBV INSPECTION, THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED BETWEEN FRAMES 24 AND 25. REMOVED THE CORROSION BY MAKING A CUTOUT. FABRICATED A FILLER, TWO SHIMS AND DOUBLER. REPAIR DONE IAW EMB SRM, SRM 145/1142, REV 28, CHAPTER 53-22-10, Feb 10, 2005 · N653AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA00502019Valve · malfunctionedSTL - ENGINE ANTI-ICE FAIL INDICATION NR 2 ENGINE. MAINTENANCE DEFERRED NR 2 ENGINE ANTI-ICE VALVE PER MEL.Feb 10, 2005 · N847HK · Emb EMB145LR · Air Intake Anti/De-Ice SystemSDR MASA200500093Switch · wornASH - CLE AIRCRAFT ABORTED TAKEOFF AND RETURNED TO THE GATE. RT REVERSER DISAGREE MESSAGE DURING TAKEOFF PRIOR TO 80 KTS. CONTRACT MAINTENANCE PERFORMED THE REQUIRED MAINTENANCE ACTION TO DEFER THE REVERSER. MAINTENANCE REPLACED STOW SWITCH.Feb 9, 2005 · N833MJ · Emb EMB145LR · Engine Thrust ReverserSDR RAIA00502018Sensor · defectiveSTL - BLEED LEAK INDICATION NR 1 ENGINE. MAINTENANCE REMOVED AND REPLACED BLEED LEAK SENSOR IN NR 1 PYLON.Feb 9, 2005 · N837HK · Emb EMB145LR · Overheat DetectionSDR C2XA05IA022Power Supply · inoperativeCHS - FLIGHT 3324, DURING PRE-FLIGHT INSPECTION, THE CREW REPORTED THAT THE EMERGENCY LIGHTS WERE ON CONTINUOUSLY, AND ROW 5 EMERGENCY LIGHTS WERE INOPERATIVE. THE AIRCRAFT WAS FERRIED TO CLE WHERE MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO EMERGENCY LIGFeb 9, 2005 · N16981 · Emb EMB145LR · Emergency LightingSDR RAIA00502014A/C Pack · malfunctionedLT PACK OVERLOAD WARNING AND SMOKE. MAINTENANCE DEFERRED NR 1 PACK PER MEL. REMOVED AND REPLACED NR 1 PACK VALVE.Feb 9, 2005 · N822HK · Emb EMB145LR · Cabin Cooling SystemSDR MASA200500094Light · misinstalledASH - CLT 2 ADJACENT EMERGENCY FLOOR PROXIMITY LIGHT STRIPS WERE INOP. MAINTENANCE FOUND THEM IMPROPERLY INSTALLED AND REINSTALLED THEM PROPERLY AND PERFORMED THE OPS CHECKS. CHECKED GOOD.Feb 9, 2005 · N836MJ · Emb EMB145LR · Emergency LightingSDR RAIA00502012Seal · leakingSTL - BLEED 1 & 2 LEAK WARNING. MAINTENANCE REMOVED AND REPLACED DUCT CLAMP AND SEAL.Feb 8, 2005 · N817HK · Emb EMB145LR · Pneumatic Distribution SystemSDR CHQA200500028Connector · looseEMERGENCY EXIT LIGHT AT AFT GALLEY IS INOP. FOUND CANNON PLUG UNDER GALLEY CEILING PANEL LOOSE. RESECURED LOOSE CANNON PLUG PER EMB 145 WM 20-50-00. OPS CHECK GOOD.Feb 7, 2005 · N267SK · Emb EMB145LR · Emergency LightingSDR RAIA00502011Connector · looseSTL - AT 3700 HAD LARGE CABIN CLIMB/DESCENT SWINGS IN AUTO AND MANUAL. MAINTENANCE SECURED LOOSE DUCT ON NR 2 PACK AND OUTFLOW VALVE CONNECTOR.Feb 7, 2005 · N823HK · Emb EMB145LR · Pressure Regulator/Outflow ValveSDR SIMA200504102Sill · corrodedDURING AN IMBV INSPECTION OF AIRCRAFT, FOUND THE SERVICE DOOR SILL CORRODED. REMOVED EXISTING SERVICE DOOR SILL AND INSTALLED SERVICEABLE SILL. REPAIR DONE IAW EMB 145 SRM, SRM EMB-145/1142 REV 28, CHAPTERS 51-20-01, 03, 51-40-02, 03, 04, 05, 06 AND 09. (M)Feb 6, 2005 · N653AE · Emb EMB145LR · Fuselage Miscellaneous StructureSDR MASA200500081Sign · inoperativeCLT-BNA, EMERGENCY EXIT SIGN ROW 12F WOULD NOT ILLUMINATE. MAINTENANCE SECURED CONNECTOR TO THE LIGHT ASSY. NO FURTHER DEFECTS NOTED.Feb 6, 2005 · N853MJ · Emb EMB145LR · Emergency LightingSDR MASA200500080Sign · inoperativeEMERGENCY EXIT SIGN AT ROW 12 INOP. MAINTENANCE SECURED THE ELECTRICAL CONNECTION TO THE LIGHT ASSEMBLY. OPS CHECKED GOOD.Feb 6, 2005 · N852MJ · Emb EMB145LR · Emergency LightingSDR RAIA00502007Probe · failedNR 1 TAT FAULT. MAINTENANCE REMOVED AND REPLACED NR 1 TAT PROBE.Feb 4, 2005 · N829HK · Emb EMB145LR · Outside Air Temperature Indicator/SensorSDR C2XA05TY011Bulb · blownTYS - DURING A 1A CHECK THE LT OVERWING EMERGENCY LIGHT WAS FOUND TO BE INOP. MAINTENANCE REMOVED AND REPLACED THE BULB AND OPS CHECK GOOD. A/C RELEASED AFTER FINAL-1A CHECK WAS C/W.Feb 4, 2005 · N17560 · Emb EMB145LR · Emergency Lighting
Back to Embraer EMB-145LR