Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA05IA021Battery Pack · dischargedEWR - FLIGHT 2879, THE CREW REPORTED THAT THE EMERGENCY LIGHTS WOULD NOT STAY ON. MAINTENANCE REMOVED AND REPLACED THE NUMBER FOUR EMERGENCY LIGHT BATTERY PACK, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA05IA020Battery Pack · dischargedEWR - FLIGHT 2879, THE CREW REPORTED THAT THE EMERGENCY LIGHTS WOULD NOT STAY ON. MAINTENANCE REMOVED AND REPLACED THE NUMBER THREE EMERGENCY LIGHT BATTERY PACK, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA05IA019Battery Pack · dischargedEWR - FLIGHT 2879, THE CREW REPORTED THAT THE EMERGENCY LIGHTS WOULD NOT STAY ON. MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO EMERGENCY LIGHT BATTERY PACK, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA05IA018Battery Pack · dischargedEWR - FLIGHT 2879, THE CREW REPORTED THAT THE EMERGENCY LIGHTS WOULD NOT STAY ON. MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE EMERGENCY LIGHT BATTERY PACK, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR MASA200500091Stringer · chafedIN C-CHECK, STRINGER 19 LT AND 19 RT ARE CHAFED OUT OF LIMITS AND HAVE BEEN REPAIRED IAW SRM 53-24-02.SDR C2XA05SH007Duct · damagedSHV - DURING CLIMB, ENG NR 2 HAS FIRE WARNING INDICATION. MAINTENANCE INSPECT AND FOUND UPPER BLEED DUCT DAMAGE NO FIRE WAS EVIDENT. REPLACE BOTH UPPER BLEED DUCTS PER EMB 145AMM 36-11-09. PERFORMS GROUND OPPERATIONAL CHECK AND LEAK CHECK PER AMM 72-00-00. SDR SIMA200503804Skin · lightning strikeDURING AN MBV INSPECTION, A LIGHTNING STRIKE WAS FOUND ON THE LT SIDE OF THE FUSELAGE BETWEEN FRAMES 32 AND 33 AT STRINGER 6L. REMOVED THE DAMAGE BY MAKING A CUT OUT. FABRICATED A FILLER, OUTER DOUBLER AND AN INNER DOUBLER. REPAIR DONE IAW SRM. (K)SDR SIMA200503403Engine · damagedDURING CLIMB AND CRUISE, NR 2 ENGINE HIGH ITT. FOUND CUSTOMER SERVICE MANIFOLD HAD COME OFF ENGINE. REPLACE NR 2 ENGINE ASSY. OPERATIONAL CHECK GOOD. AC RETURNED TO SERVICE.SDR MASA200500090Floor Support · corrodedIN C-CHECK, OMEGA BEAM (HAT BEAM) IS CORRODED OUT OF LIMITS AT BL 0 AND WILL BE REMOVED AND REPLACED.SDR MASA200500089Gusset · corrodedIN C-CHECK GUSSET IS CORRODED OUT OF LIMITS AT BL 0 AND WILL BE REMOVED AND REPLACED.SDR MASA200500088Support Angle · corrodedIN C-CHECK, SUPPORT ANGLE P/N 145-22459-003 IS HEAVILY CORRODED AND HAS BEEN REPLACED WITH NEW PART.SDR RAIA00502001O-Ring · leakingSTL - IN FLIGHT LOW OIL PRESSURE AND OIL QUANTITY NR 1 ENGINE. COMPLETE CHECKLIST PERFORMED PRECAUTIONARY SHUTDOWN. MAINTENANCE INSPECTED AND FOUND OIL FILTER O-RING BROKEN. REMOVED AND REPLACED OIL FILTER HOUSING O-RING.SDR MASA200500074Switch · inoperativeCLT HAD A SERVICE DOOR INDICATION INOP. MAINTENANCE PLACED DOOR INDICATION SYSTEM ON MEL. MAINTENANCE REMOVED AND REPLACED SWITCH. OPS GOOD.SDR MASA200500073Bulb · burned outREPORTED AN EMERGENCY OVERHEAD FLOOD LIGHT INOP AT ROW 12. MAINTENANCE REPLACED THE LAMP.SDR MASA200500072Light · inoperativeAIRCRAFT WAS ON RON AND SCHEDULED FOR A ROUTINE INSPECTION. DURING THE WALKAROUND IT WAS DISCOVERED THE 4TH EMERGENCY LIGHTED FLOOR STRIP NOT ILLUMINATED. REPLACED THE LIGHTED FLOOR STRIP. OPERATIONAL CHECK GOOD.SDR CHQA200500024Carbon Seal · leakingFLIGHT 3217 - LGA-PHL - WHILE EN ROUTE A LAV SMOKE MASTER WARNING APPEARED ON EICAS. THE APPROPRIATE QRH CHECKLIST WAS COMPLETED. THE FLIGHT ATTENDANT CHECKED THE LAV AND SAW NO SMOKE OR FIRE AND NO SMELL WAS PRESENT ANYWHERE IN THE AIRCRAFT. THE EICAS MESSSDR SIMA200503401Floor Support · corrodedTHE LEFT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 20. REMOVED THE CORROSION BY MAKING A CUT OUT. FABRICATED A DOUBLER, FILLER, TWO SHIMS AND PLATE. REPAIR DONE IAW SRM. (K)SDR RAIA00501059Pressure Switch · failedSTL - NO TAKEOFF CONFIGURATION, EICAS MESSAGE. MAINTENANCE REMOVED AND REPLACED EMERGENCY PARKING BRAKE PRESSURE SWITCH.SDR CHQA200500023Static Inverter · unserviceableMAIN DOOR EMERGENCY EXIT SIGN IS INOP. FOUND THE STATIC INVERTER FAULTY FOR THE MAIN DOOR EMERGENCY EXIT SIGN. REMOVED AND REPLACED THE STATIC INVERTER IAW EMB 145 AMM 33-50-11. EMERGENCY LIGHTS OPS CHECK GOOD.SDR SIMA200503402Floor Support · corrodedTHE GALLEY CENTER BEAM WAS FOUND TO BE CORRODED. REMOVED THE CORRODED GALLEY CENTER BEAM. INSTALLED NEW BEAM IAW SRM. (K)SDR SIMA200503411Strap · corrodedFOUND STRAP UNDER FORWARD CABIN FLOOR BETWEEN FRAMES 14 AND 16, HAS CORROSION ON UPPER FORWARD SURFACE. REMOVED CORROSION ON STRAP UNDER FORWARD CABIN FLOOR BETWEEN FRAMES 14 AND 16 IAW SRM. AIRCRAFT WAS RETURNED TO SERVICE. (K)SDR CHQA200500021Smoke Detector · malfunctionedFLIGHT 3083 - ROC-DCA - AFTER BOARDING THE AIRCRAFT TAXIED TO THE DEICE PAD FOR DEICING. AFTER THREE MINUTES THE BLEEDS AND PACKS WERE TURNED ON AND THE AIRCRAFT DEPARTED NORMALLY. DURING CLIMB OUT AT 10,000 FEET, A LAV SMOKE WARNING WAS ON EICAS. THE FLIGHSDR SIMA200503407Doubler · corrodedFOUND DOUBLER UNDER CABIN FLOOR AT FRAME 20 CORRODED ON UPPER SURFACE. REPLACED DOUBLER UNDER CABIN FLOOR IAW SRM. AC RETURNED TO SERVICE. (K)SDR SIMA200503408Sill · corrodedFOUND RT SILL AFT OF SERVICE DOOR HAS CORROSION ON FWD UPPER SURFACE AT FRAME 22. REMOVED CORROSION FROM WEB IAW SRM. AC RETURNED TO SERVICE. (K)SDR SIMA200503409Gusset · corrodedFOUND GUSSET UNDER CABIN FLOOR FRAME 20 TO 23 HAS CORROSION IN SEVERAL AREAS OF UPPER SURFACE. REPLACED GUSSET IAW SRM. AC RETURNED TO SERVICE. (K)SDR SIMA200503412Channel · corrodedFOUND SHAPE U UNDER FORWARD CABIN FLOOR AT LOWER MAIN DOOR OPENING BETWEEN FRAME 14 AND 18 CORRODED AROUND NUTPLATES. REPLACED SHAPE U AT PAX DOOR SILL AREA IAW SRM. AC RETURNED TO SERVICE. (K)SDR SIMA200503413Channel · corrodedFOUND SHAPE U UNDER FORWARD CABIN FLOOR AT LOWER MAIN DOOR OPENING BETWEEN FRAMES 14 AND 18 CORRODED AROUND NUTPLATES. REPLACED SHAPE U AT MAIN CABIN DOOR SILL AREA IAW SRM. AC RETURNED TO SERVICE. (K)SDR MASA200500063Battery · failedLT FWD OUTSIDE EMERGENCY LIGHT WILL NOT ILLUMINATE. CAE MX DEFERRED THE LIGHT IAW MEL 33-50-00-1. LATER IN THE DAY, CLT MX CLEARED THE DEFERRAL BY REPLACING THE LIGHT SOCKET AND EMERGENCY BATTERY. LIGHT P/N 30-2510-3.SDR C2XA05TY009Connector · damagedTYS, CONTINUATION OF CONTROL NR C2XA05TY008, AIR RETURN FOR LANDING GEAR AIR GROUND FAIL ON TAKEOFF. MAINTENANCE FOUND THE LEFT MLG FORWARD AND AFT WOW PROX SWITCHES ONLY 250K RESISTANCE, SHOULD BE 1.4M. MAINTENANCE REMOVED AND REPLACED THE LEFT GEAR CANNON SDR MASA200500062Sign · inoperativeAIRCRAFT WAS ON RON AND SCHEDULED FOR A 2 DAY EN ROUTE INSPECTION. DURING THE WALKAROUND IT WAS DISCOVERED THE LEFT HAND ROW 12 SIDEWALL EMERGENCY LIGHT SIGN WAS NOT ILLUMINATING. MAINTENANCE REPLACED THE LIGHT EXIT SIGN. OPERATIONAL CHECK GOOD.SDR C2XA05TY008Proximity Switch · defectiveTYS - A/C WAS DEPARTING BHM WHEN THE ICAS MESSAGE SHOWED GEAR NOT RETRACTED. A/C RETURNED TO BLOCK AND MAINTENANCE REMOVED AND REPLACED THE LGEU, BUT DID NOT FIX PROBLEM. A/C WAS FERRIED TO TYS AND MAINTENANCE REMOVED AND REPLACED THE NR 1 AND NR 2 PROX SWITSDR SIMA200503405Channel · corrodedFOUND SERVICE DOOR CHANNEL BETWEEN FRAME 20-22 HAS CORROSION AROUND NUTPLATES UPPER SURFACE. INSTALLED NEW SERVICE DOOR CHANNEL IAW SRM. AIRCRAFT WAS RETURNED TO SERVICE. (K)SDR SIMA200503406Seat Track · corrodedFOUND LT FORWARD SEAT TRACK CORRODED. REPLACED SEAT TRACK IAW AMM. AIRCRAFT WAS RETURNED TO SERVICE. (K)SDR C2XA05IA015Power Supply · inoperativeMCI - DURING MAINTENANCE INSPECTION, BOTH THE LT AND RT EXTERIOR OVERWING EMERGENCY EXIT LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER FOUR EMERGENCY LIGHT BATTERY POWER SUPPLY, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THESDR C2XA05BT008Pressure Switch · faultyEWR - CO2514, CREW REPORTED, ON SHORT FINAL, AUTOPILOT DISCONNECTED, YAW DAMPENER FAIL, AND RUDDER SYSTEM NR 1 AND NR 2 FAIL INDICATION, CREW DECLARED AN EMERGENCY AND LANDED UNEVENTFULLY. MAINTENANCE REMOVED AND REPLACED NR 1 AND NR 2 RUDDER PRESSURE SWITCHSDR CHQA200500017Sign · inoperativeFORWARD EMERGENCY LIGHTED EXIT SIGN IS INOP. REMOVED AND REPLACED FORWARD EMERGENCY LIGHTED SIGN IAW EMB 145 AMM 33-50-14-4. OPS CHECK GOOD.SDR CHQA200500016Odor · detectedDURING CLIMB A LAV SMOKE MESSAGE APPEARED ON EICAS. THE FLIGHT ATTENDANT INVESTIGATED AND FOUND NO INDICATION OF FIRE OR SMOKE IN ANY PART OF THE CABIN OR LAVATORY. EICAS INDICATIONS WERE EXTINGUISHED WITHIN ONE MINUTE. THE AIRCRAFT RETURNED TO FIELD IN ROCSDR SIMA200502504Odor · detectedDURING TAXI CREW REPORTED FUEL SMELL IN THE CABIN AND COCKPIT. PASSENGER REPORTED THE SMELL AT ROW 8. MAINTENANCE GROUND RUN ENGINES TO CHECK AIR CONDITION SYSTEM FOR FUEL ODOR. NONE WAS DETECTED AT THIS TIME. MAINTENANCE COULD NOT DUPLICATE DISCREPANCY ANSDR RAIA00501053Igniter · inoperativeORF - NR 2 ENGINE WILL NOT START TRIED CROSS-BLEED AND APU. MAINTENANCE REMOVED AND REPLACED BOTTOM IGNITER ON NR 2 ENGINE.SDR C2XA05CL006Bleed Air Sys · contaminatedCLE - FLT NR 2139 - AFTER TAKEOFF, THE CREW GOT THE LAVATORY SMOKE INDICATION ON THE EICAS WITH A NOTICABLE SMOKE SMELL. RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AIRCRAFT AND FOUND DE-ICING FLUID IN THE BLEED SYSTEM. CLEARED DE-ICISDR MASA200500052Bulb · burned outAN AFT EMERGENCY CEILING LIGHT INOPERATIVE. MAINTENANCE REPLACED THE LAMP, OPS CHECK GOOD.SDR RAIA00501047Warning Light · illuminatedSTL - NR 1 ENGINE DISAGREE MESSAGE ON EICAS ON TAKEOFF. MAINTENANCE DEFERRED THRUST REV PER MEL 78-30-00 CAT C. PERFORMED OPS CHECK ON NR 1 ENGINE THRUST REVERSE, OPS CHECK GOOD.SDR RAIA00501048Probe · failedSTL - TAT NR 1 HEAT INOP EICAS WITH OVERRIDE IN ENGINE DURING TAXI. MAINTENANCE REMOVED AND REPLACED NR 1 TAT PROBE.SDR CHQA200500011Battery Pack · dischargedTHE EMERGENCY LIGHTS WERE LEFT IN THE ARMED POSITION BY THE PREVIOUS CREW ON SHUTDOWN. THE BATTERIES ARE NOW DEAD. REMOVED AND REPLACED ALL FOUR EMERGENCY LIGHT BATTERIES IAW EMB 145 AMM 33-50-04. OPS CHECK GOOD.SDR MASA200500050Pump · inoperativeCLE TO CLT FLIGHT CREW REPORTED A NR 1 HYDRAULIC SYSTEM OVERTEMP CONDITION IN FLIGHT. AS PER CFM, SHUTDOWN HYDRAULIC PUMPS AND WAITED 15 MINUTES FOR OVERTEMP CONDITION TO COOL. ATTEMPTED TO TURN NR 1 HYDRAULICS ON. NEITHER ENGINE DRIVEN NOR ELECTRIC PUMPS WSDR RAIA00501045Proximity Switch · dirtyJAX - ENGINE 1 REV DISAGREE SPOILER FAIL MESSAGE ON EICAS. MAINTENANCE INSPECTED AND CLEANED LANDING GEAR PROX SWITCHES.SDR CHQA200500015Connector · looseFLIGHT 3082 - CHS-LGA - AFTER GEAR RETRACTION ON TAKEOFF, LG AIR/GND FAIL MESSAGE APPEARED ON EICAS. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO THE FIELD AND LANDED NORMALLY. MAINTENANCE CLEANED ALL PROXIMITY SWITCHES AND FOUND A LOOSE CONNECTOR SDR MASA20050048Light · inoperativePILOT REPORTED SEVERAL SECTIONS OF THE EMERGENCY FLOOR PATH LIGHTING INOP. MAINTENANCE RESET THE SYSTEM AND WERE UNABLE TO DUPLICATE THE DISCREPANCY.SDR MASA200500047Switch · out of rigASH - CLT TO STL ABORTED TAKEOFF AND RETURNED TO THE GATE DUE TO A NR 2 ENGINE THRUST RVERSER DISAGREE. MAINTENANCE COMPLIED WITH THE MEL. MAINTENANCE SHIMMED AND RIGGED SWITCHED, OPS CHECK GOOD.SDR C2XA05BT006Bulb · burned outDURING SERVICE AND ROUTINE CHECK IN BTV MAINTENANCE FOUND THE EMERGENCY LIGHT INOPERATIVE AT SEAT 12A PSU. REMOVED AND REPLACED EMERGENCY EXIT LIGHT ASSEMBLY BULB AT SEAT 12A PSU IAW EMB145 AMM 33-50-07. OPS CHECKED GOOD.
Back to Embraer EMB-145LR