Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA02BT060Connector · shortedSTRONG ELECTRICAL SMELL IN GALLEY. MAINTENANCE FOUND SHORTED NUMBER ONE COFFEE POT CONNECTOR. MAINTENANCE REMOVED AND REPLACED COFFEE POT CONNECTOR AND REPLACED COFFEE POT UNIT. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR C2XA02TY152Sill · corrodedTYS, During a scheduled inspection, the service door forward sill was found corroded. Maintenance removed the corroded area, fabricated doublers, installed and restored finish. I/A/W-EMB-GST-1927/02A. The repair was satisfactory and the aircraft will be releasSDR C2XA02TY151Sill · corrodedTYS, During a scheduled inspection, the service door aft sill was found corroded. Maintenance removed the corroded area, fabricated doublers, installed and restored finish. I/A/W-EMB-GST-1927/02A. The repair was satisfactory and the aircraft will be released uSDR C2XA02TY150Skin · dentedDURING A SCHEDULED INSPECTION, THE PASSENGER DOOR WAS FOUND DENTED AT LOWER FORWARD CORNER. MAINTENANCE RECONTOURED THE DENTED AREA, PERFORMED DYE PENETRANT INSPECTION, NO DEFECTS NOTED. IAW EMB-GST-2984/02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BESDR SIMA200230311Channel · corrodedABI - DURING AN IMBV INSPECTION, THE GALLEY AREA RIGHT HAT BEAM WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. COMPLETELY REMOVED CORROSION BY CUTOUT. FABRICATED A U-SHAPED DOUBLER. REPAIR DONE IAW EMB 145 GST-2990/02 AND STANDARD EMB SRM PRACTICES. (M)SDR SIMA200230304Channel · corrodedABI - DURING AN IMBV, THE GALLEY AREA RIGHT HAT BEAM WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. COMPLETELY REMOVED CORROSION BY CUTOUT. FABRICATED A 'U' SHAPED DOUBLER. REPAIR DONE IAW EMB 145 GST-2990/02 AND STANDARD EMB SRM PRACTICES. (M)SDR C2XA02IA223Bearing · looseTHE CREW NOTED THAT THERE WAS A VIBRATION IN THE CONTROL YOKE. VIBRATION BEGAN IN THE LOW 30,000'S AND CONTINUED IN CLIMB TO 35,000. VIBRATION SEEMED MORE PRONOUNCED AS AIRCRAFT ACCELERATED, VIBRATION DECREASED MARKABLY BELOW 30,000 FT, COULD ALSO FEEL SDR C2XA02CL197Wire · looseCLE FLIGHT#3194 THE CREW REPORTED THE EMERGENCY EXIT LIGHT AT THE GALLEY SERVICE DOOR WAS INOPERATIVE.MAINTENANCE INSPECTED AND RESECURED LOOSE WIRE ON THE EMERGENCY EXIT LIGHT.OPERATIONAL CHECKS WERE GOOD.SDR SIMA200230310Floorbeam · corrodedABI - DURING AN IMBV INSPECTION, THE FORWARD DIGITAL IN THE GALLEY AREA WAS FOUND TO BE CORRODED BELOW SRM LIMITS. REMOVED SECTION OF EXISTING DIGITAL. FABRICATED TWO REPAIR DOUBLERS AND SHIMS. REPAIR DONE IAW EMB 145 SRM, SRM 145/1142 REV 19, CHAPTER 53-21SDR SIMA200230303Floorbeam · corrodedABI - DURING AN IMBV INSPECTION, THE FORWARD DIGITAL IN THE GALLEY AREA WAS FOUND TO BE CORRODED BELOW SRM LIMITS. REMOVED SECTION OF EXISTING DIGITAL. FABRICATED TWO REPAIR DOUBLERS AND SHIMS. REPAIR DONE IAW EMB145 SRM, SRM 145/1142 REV 19, CHAPTER 53-21-SDR SIMA200230341Sill · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY AREA LEFT SILL HAS CORROSION. INSTALLED SERVICEABLE LEFT SILL IAW EMB 145 SRM 51-40-02. (M)SDR MASA200200014Light · inoperativeAIR SHUTTLE 5860, CLT TO BTR HAD A SEGMENT OF EMERGENCY FLOOR PATH LIGHTING INOPERATIVE. MX T/S AND REPLACED THE SEGMENT BATTERY.SDR MASA200200013Light · inoperativeAIR SHUTTLE 5834 FROM PHL TO CLE HAD THE NR 4 OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. WHEN MX REMOVED THE COVER TO REPLACE THE LAMP, THE LIGHT STARTED WORKING NORMALLY. A/C DEPARTED WITHOUT FURTHER INCIDENT.SDR C2XA02IA213Proximity Switch · inoperativeFLIGHT 3850, THE CREW NOTED DURING CLIMB THAT THE LANDING GEAR WOULDN'T RETRACT,RETURNED TO IAH, AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE RT SHOCK ABSORBER PROXIMITY SWITCH, PERFORMED A OPERATIONAL CHECK, NO DEFECTS NOTED, AND THE AIRSDR C2XA02IA214Tank · odorIAH- THE CREW NOTED A STRONG ODOR OF FUEL AFTER TAKEOFF. THE ODOR OF FUEL WENT AWAY AFTER APU SHUT DOWN. MAINTENANCE DRAINED FUEL FROM THE EPA TANK, GROUND RAN APU, NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR MASA200200011Connector · looseOVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. MX T/S AND FOUND CONNECTOR LOOSE. RESECURED, OPS CHECK GOOD.SDR SIMA200231705Gusset · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY AREA FORWARD DIAMOND GUSSET HAS CORROSION. REMOVED CORRODED DIAMOND GUSSET AND INSTALLED SERVICEABLE GUSSET IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200230342Sill · corrodedABI - THIS IS A LEVEL 2 FINDING, RIGHT AFT SILL HAS CORROSION. INSTALLED SERVICEABLE SILL IAW EMB SRM 51-40-02, 51-40-06 AND 51-20-03. (M)SDR SIMA20023034Floorbeam · corrodedABI - THIS IS A LEVEL 2 FINDING, LEFT OMEGA BEAM FLOOR SUPPORT ANGLE HAS CORROSION. REMOVED AND REPLACED FLOOR ANGLE IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200230339Sill · corrodedABI - THIS IS A LEVEL 2 FINDING, SERVICE DOOR CENTER SILL HAS CORROSION. REMOVED AND REPLACED SILL IAW EMB GST-2969/02. (M)SDR SIMA200230338Sill · corrodedABI - THIS IS A LEVEL 2 FINDING, RIGHT FORWARD SILL HAS CORROSION. INSTALLED SERVICEABLE SILL IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200230337Gusset · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY AREA FORWARD GUSSET (DIAMOND) HAS CORROSION. INSTALLED SERVICEABLE GUSSET IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200230336Gusset · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY ARE AFT DIAMOND GUSSET HAS CORROSION. INSTALLED SERVICEABLE AFT DIAMOND GUSSET IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200230335Support · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY RAMP SUPPORT HAS CORROSION. INSTALLED SERVICEABLE GALLEY RAMP SUPPORT IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200230334Floor Support · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY AREA CENTER BEAM GUSSET HAS CORROSION. INSTALLED SERVICEABLE CENTER BEAM GUSSET IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200230333Seat Track · corrodedABI - THIS IS A LEVEL 2 FINDING, LEFT FORWARD INBOARD SEAT TRACK HAS CORROSION. REMOVED AND INSTALLED SERVICEABLE SEAT TRACK IAW EMB 145 AMM 53-01-06. (M)SDR MASA200200008Light · inoperativeAIRSHUTTLE 5731 FROM PHL TO DTW PILOT REPORTED THE CABIN CEILING EMERGENCY EXIT LIGHT INOPERATIVE. MAINT REPLACED THE LIGHT.SDR SIMA200228224Sill · corrodedDURING AN MBV INSPECTION, CORROSION WAS FOUND ON SERVICE DOOR CENTER SILL THAT WAS BEYOND SRM LIMITS. REMOVED CORROSION BY BLENDING. PERFORMED AN NDT INSPECTION OF THE BLENDED AREAS. NO DEFECTS NOTED. FABRICATED THREE REPAIR DOUBLERS. REPAIR DONE IAW SRM.SDR SIMA200228217Floorbeam · corrodedDURING A IMBV INSPECTION LEFT HAND BEAM AT FRAME 25 WAS FOUND TO BE CORRODED BELOW SRM LIMITS. CUT OUT SECTION OF DAMAGED BEAM. FABRICATED A FILLER, TWO SHIMS AND EXTERNAL ANGLE. REPAIR DONE IAW SRM.SDR C2XA02CL192Light · malfunctionedCLE FLIGHT NR 3282 THE CREW REPORTED SPARKS AND FIRE CAME FROM FLUORESCENT CABIN LIGHT AT SEAT 12C. MAINTENANCE INSPECTED AND REPLACED THE PASSENGER CABIN LIGHT ASSEMBLY. OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR C2XA02IA208Odor · detectedIAH- APU FAIL IN FLIGHT. FUEL ODOR IN CABIN WITH APU RUNNING. MAINTENANCE PERFORMED A OPERATIONAL CHECK OF THE APU, NO DEFECTS NOTED. PERFORMED A VISUAL INSPECTION OF THE FUEL LINES AT THE APU, NO LEAKS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SESDR C2XA02BT059Inverter · looseEWR---CO3039, CREW REPORTED, THE GALLEY DOOR EMERGENCY LIGHT WAS INOPERATIVE....MAINTENANCE FOUND A LOOSE CONNECTOR AND RESECURED THE CANNON PLUG. OPS.CHECKED SYSTEM GOOD.SDR SIMA200228207Floorbeam · corrodedDURING AN IMBV INSPECTION, CORROSION WAS FOUND ON THE GALLEY CENTER FLOORBEAM. REMOVED CORRODED GALLEY CENTER FLOORBEAM INSTALLED NEW BEAM IAW SRM.SDR C2XA02IA210Control Unit · inoperativeTHE CREW NOTED THAT THE LANDING GEAR WOULD NOT RETRACT,AND RETURNED TO IAH, AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE LANDING GEAR ELECTRONIC UNIT, PERFORMED A OPERATIONAL CHECK OF THE LANDING GEAR SYSTEM, NO DEFECTS NOTED, AND THE AISDR SIMA200228220Floorbeam · corrodedDURING AN IMBV INSPECTION, THE DIGITAL WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. REMOVED DAMAGED SECTION OF THE FORWARD DIGITAL BY CUT OUT. FABRICATED A REPLACEMENT STRAP AND TWO DOUBLERS, SHIMS. REPAIR DONE IAW SRM.SDR C2XA02CL190Fire Loop · chafedCLE FLIGHT NR 3242, CREW REPORTED ENGINE NR 2 FIRE DETECT FAIL MESSAGE. MAINTENANCE INSPECTED AND FOUND THE FIRE LOOP WAS CHAFED. THE NR 2 ENGINE FIRE LOOP WAS REPLACED. OPERATIONAL CHECKS WERE GOOD.SDR SIMA200228222Doubler · corrodedDURING AN IMBV INSPECTION CORROSION WAS FOUND ON A PREVIOUS REPAIR TO THE LEFT HAND OMEGA BEAM AT FRAME 20. REMOVED PREVIOUS REPAIR AND INSPECTION THE UNDERLYING BEAM. NO ADDITIONAL DAMAGE NOTED. FABRICATED AN EXTERNAL ANGLE, FILLER, TWO SHIMS, PLATE. REPASDR SIMA200228223Floorbeam · corrodedDURING AN IMBV INSPECTION OF AIRCRAFT, CORROSION WAS FOUND ON THE LEFT HAND OMEGA BEAM AT FRAME 29. REMOVED CORROSION BY CUT OUT. FABRICATED AN EXTERNAL ANGLE, FILLER, TWO SHIMS. REPAIR DONE IAW SRM.SDR SIMA200228208Stringer · chafedDURING AN IMBV INSPECTION FOUND STRINGER 19L CHAFED. BLENDED CHAFE. PERFORMED AND NDT INSPECTION OF THE AREA AND FOUND NO REJECTABLE INDICATIONS. REPAIR DONE IAW SRM.SDR C2XA02SH066Skin · gougedSHV- DURING C CHECK INSPECTION THREE GOUGES WERE FOUND ON SKIN FRAME 20 AT STRINGER 11L. MAINTENANCE REMOVED AND REPAIRED DAMAGE IN IAW EC 5320-01075. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA02SH065Stringer · gougedDURING C CHECK A GOUGE WAS FOUND ON STRINGER 19 RT BETWEEN FRAMES 52 AND 53. MAINTENANCE BLENDED GOUGE, PERFORMED DYE PENATRANT INSPECTION AND INSTALLED AT REINFORCEMENT AT STRINGER 19 RT BETWEEN FRAMES 52 AND 53 IAW EMB 145 SRM 53-24-02. THE AIRCRAFT WAS APPSDR SIMA200228216Floorbeam · corrodedDURING AN IMBV INSPECTION THE RIGHT FLOORBEAM WAS FOUND TO BE CORRODED BEYOND SRM LIMITS AT FRAME 23. BLENDED THE DAMAGED AREA TO COMPLETELY REMOVED THE CORROSION. FABRICATED A U SHAPED DOUBLER. REPAIR DONE IAW SRM.SDR C2XA02SH068Floorbeam · corrodedSHV - DURING C CHECK THE GALLEY FLOORBEAM ANGLE WAS FOUND TO HAVE CORROSION. MAINTENANCE REMOVED AN REPLACED FLOORBEAM ANGLE IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA02SH070Stringer · damagedSHV DURING C CHECK INDENTATION WAS FOUND ON LT ENGINE LOWER NACELLE SKIN OUTBOARD STRINGER 8 INCHES FROM AFT END. MAINTENANCE REMOVED DAMAGED AREA AND PERFORMED AN ANGLE REPAIR IAW EMB 145 SRM 54-10-07. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICESDR C2XA02SH067Structure · damagedDURING C CHECK LT SPEED BRAKE OUTER TRAILING EDGE IS WRAPED. MAINTENANCE REMOVED AND REPLACED LT SPEED BRAKE. OPERATIONAL CHECK GOOD IAW EMB 145 AMM 27-63-01. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR MASA200200003First Aid KitFIRST AID KIT OPENED AND BANDAID USED. REPLACED FIRST AID KIT.SDR SIM2002F00000Frame · crackedDURING AN INSPECTION OF AN EXISTING REPAIR TO FRAME 73 AT STRINGER 15L ADDITIONAL DAMAGE IN THE FORM OF A .75 INCH LONG CRACK, WAS FOUND. REMOVED THE EXISTING REPAIR PERFORMED AN EDDY CURRENT INSPECTION TO CONFIRM CRACK ENDED AT A RIVET HOLE. FABRICATED AN LSDR SIMA200228226Sill · corrodedDURING AN IMBV INSPECTION OF AIRCRAFT, THE CARGO DOOR LOWER SILL WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. REMOVED CORRODED SILL. INSTALLED SERVICEABLE SILL IAW SRM.SDR C2XA02CL189Outflow Valve · leakingCLE FLIGHT NR 3219 THE CREW REPORTED DURING CLIMBOUT THE AIRCRAFT PRESSURIZATION SURGED, CABIN RATE WENT FROM 1750 TO 1800. RESET TO MANUAL AND LOST CABIN ALTITUDE INDICATION. THE AIRCRAFT RETURNED TO CLEVELAND AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUNDSDR MASA200200027Apu · fireUPON DESCENT INTO BTR, CAPTAIN ATTEMPTED TO START APU. EXPERIENCED 3 HUNG STARTS OF APU. AFTER THIRD START ATTEMPT, CAPTAIN EXPERIENCED AN APU FIRE WARNING MSG ON THE EICAS. A/C LANDED AT BTR WITHOUT INCIDENT. UPON INSPECTION AFTER LANDING, THERE WAS EVIDENCE
Back to Embraer EMB-145LR