Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA200228218Frame · chafedDURING A IMBV INSPECTION FOUND LOWER FRAME 81 CHAFED BEYOND SRM LIMITS. REMOVED EXISTING LOWER FRAME 81. INSTALLED NEW FRAME IAW SRM.SDR C2XA02CL187Inverter · inoperativeCLE FLIGHT#4368 THE CREW REPORTED THE EMERGENCY EXIT LIGHT ON THE GALLEY DOOR WAS INOPERATIVE.MAINTENANCE REPLACED THE EMERGENCY LIGHT INVERTER.OPERATIONAL CHECKS WERE GOOD.SDR SIMA200226808Sign · inoperativeDFW - DURING PHASE INSPECTION MAINTENANCE REPORTED THE EMERGENCY EXIT SIGN AT ROW 3BC TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY EXIT SIGN AT ROW 3BC IAW EMB MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR C2XA02BT056Engine · shutdownCVG---CO3395, CREW REPORTED, "SMOKE IN COCKPIT AND CABIN ASSOCIATED WITH HIGH ITT ON #1 ENGINE AND COMPLETE LOSS OF OIL PRESSURE. NO FIRE WARNINGS OR INDICATIONS OTHER THAN SMOKE. SMOKE DISSAPATED WHEN # 1 ENGINE WAS SHUTDOWN." MAINTENANCE REMOVED AND REPLACESDR RAIA00210266Bulb · burned outMX-PIT-EMERGENCY LIGHT INOP AT GALLEY. REMOVED AND REPLACED EMERGENCY LIGHT BULB AT GALLEY, OPS CK OK.SDR SIMA200228225Sill · corrodedRIGHT SILL CORRODED BETWEEN FRAME 24 AND 29. PERFORMED EDDY CURRENT AND THICKNESS INSPECTION WITH NO DEFECTS FOUND. REPLACED SILL IAW GST.SDR SIMA200228Frame · corrodedSTRINGER 19L HAS CORROSION BETWEEN FRAMES 23 AND 24 UNDER FLOOR. PERFORMED EDDY CURRENT AND THICKNESS, NO DEFECTS. REPAIR DONE IAW GST.SDR SIMA200228205Sill · corrodedRIGHT HAND SILL IS CORRODED BETWEEN FRAME 29 AND 35. PERFORMED NDT INSPECTION WITH NO DEFECTS NOTED. REPAIRED RIGHT HAND SILL BETWEEN FR 29-35 IAW GST.SDR C2XA02BT055Power Supply · faultyBTV---CO3389, DURING 5A INSPECTION MAINTENANCE FOUND EMERGENCY LIGHTS DO NOT COME ON IN AUTO MODE....REMOVED AND REPLACED #2 EMERGENCY LIGHT BATTERY POWER SUPPLY/CHARGER IAW EMB145 MM 33-50-04. OPS.CHECKED GOOD.SDR SIMA200228214Sill · corrodedCARGO DOOR SILL IS CORRODED. REMOVED AND INSTALLED NEW CARGO DOOR SILL IAW CPM.SDR SIMA200228206Floorbeam · corrodedLEFT HAND FLOOR BEAM GUSSET IS CORRODED BETWEEN FRAME 65-68. INSTALLED SERVICEABLE GUSSET IAW SRM.SDR SIMA200227914Floorbeam · corrodedABI - DURNG AN IMBV INSPECTION, THE GALLEY AREA FORWARD DIGITAL WAS FOUND TO BE CORRODED. FABRICATED A SHIM AND TWO DOUBLERS. REPAIRED IAW EMB-145 SRM 145/1142, 53-21-10, AND STANDARD SRM PRACTICES. (M)SDR SIMA200227921Sill · corrodedDURING AN IMBV INSPECTION, CARGO DOOR LOWER SILL WAS FOUND CORRODED BELOW SRM LIMITS. REMOVED EXISTING CARGO DOOR LOWER SILL. INSTALLED SERVICEABLE SILL IAW MFG SRM.SDR SIMA200228221Floor Support · corrodedCENTER BEAM RAMP IS CORRODED. REMOVED AND INSTALLED NEW CENTER BEAM GUSSET IAW SRM.SDR SIMA200228215Floorbeam · corrodedPREVIOUS REPAIR AT FRAME 20 ON LEFT FLOORBEAM IS CORRODED. REPAIRED IAW SRM.SDR SIMA200228213Floorbeam · corrodedRIGHT FLOORBEAM CORRODED AT FRAME 23. REPAIRED IAW SRM.SDR SIMA200228212Angle · corrodedPROFILE AT FRAME 23 IS CORRODED. REMOVED AND REPAIRED PROFILE AND DOUBLER. REPAIR DONE IAW SRM.SDR SIMA200228211Seat Track · corrodedSEAT TRACK CORRODED BETWEEN FRAMES 18 AND 23 ON LEFT FLOORBEAM. REMOVED AND REPLACED SEAT TRACK IAW AMM.SDR SIMA200228210Crossbeam · corrodedCROSSMEMBER AT FRAME 23 IS CORRODED. REMOVED CROSSMEMBER AND REPAIRED IAW SRM.SDR SIMA200228209Floor Support · corrodedPASSENGER DOOR FLOOR SUPPORT CORRODED. REMOVED AND INSTALLED SERVICEABLE SUPPORT IAW SRM.SDR SIMA200227915Floorbeam · corrodedABI - DURING IMBV INSPECTION, MAINTENANCE FOUND CORROSION ON GALLEY CENTER FLOOR BEAM. CUT OUT SECTION GALLEY CENTER BEAM. FABRICATED A U-BEAM DOUBLER, FILLER. REPAIR DONE IAE EMB-145 SRM 145/1142, CHAPTER 51, REV 19, 51-40-02, ENB GST-1736/02-C ETN EM-53-0SDR SIMA200226802Stringer · chafedABI - DURING AN IMBV INSPECTION MAINTENANCE FOUND STRINGER 19R CHAFED BETWEEN FRAMES 52 AND 53. BLENDED CHAFED AREA. PERFORMED AN NDT INSPECTION OF THE AREA AND FOUND NO REJECTABLE INDICATIONS. FABRICATED A DOUBLER ANGLE, TWO SHIMS. REPAIR DONE IAW EMB-145SDR C2XA02IA200Bypass Valve · inoperativeIAH- FLIGHT 2908 NR 1 BLEED OVERTEMP WHILE CLIMBING THROUGH FL200 WHEN ENTERING ICING CONDITIONS QRH COMPLETED. MAINTENANCE REMOVED AND REPLACED NR 1 FAN AIR BYPASS VALVE, PERFORMED A OPERATIONAL CHECK, NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETSDR SIMA200226201Battery Pack · dischargedRIC - FLT 4100 - EMERGENCY LIGHTS AT RIGHT FLOOR AND WING EXIT INOPERATIVE. RAI EMERGENCY BATTERY PACK AND RIGHT FLOOR LIGHT STRIPS IAW EMB AMM 33-50, OPS CHECK GOOD. (M)SDR C2XA02CL184ContactorEWR FLIGHT#3764 THE CREW REPORTED WHILE IN FLIGHT DURING CROSS FEED OPERATION PUMP 1B INDICATED OFF.THE PUMP WORKED ON THE GROUND.MAINTENANCE INSPECTED AND REPLACED THE 1B FUEL PUMP CONTACTOR.OPERATIONAL CHECKS WERE GOOD.SDR SIMA200226108Battery Pack · dischargedDLH - FLT 4168 - CREW REPORTED TWO AFT EMERGENCY LIGHTS TO BE INOPERATIVE. AIRCRAFT WAS FERRIED TO ORD FOR REPAIR. MAINTENANCE REMOVED AND REPLACED A POWER SUPPLY BATTERY PACK IAW EMB MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR SIMA200227920Stringer · chafedDURING AN IMBV INSPECTION, STRINGER 19R WAS FOUND TO BE CHAFED. BLENDED CHAFED AREA. PERFORMED AN NON DESTRUCTIVE TESTING INSPECTION WITH NO DEFECTS NOTED. FABRICATED A DOUBLER ANGLE AND TWO SHIMS. REPAIR DONE IAW MFG SRM AND STANDARD SRM PRACTICES.SDR SIMA200226101Stringer · corrodedABI - DURING AN IMBV INSPECTION, FOUND CORROSION ON STRINGER 21R BETWEEN FRAMES 12 AND 13. CUT OUT 2 DAMAGED AREAS OF STRINGER LOWER FLANGE BETWEEN FRAMES 12 AND 13. FABRICATED 2 FILLERS, 1 REINFORCEMENT, REPAIR DONE IAW EMB GST-2763/02 PARA 2B, AND STANDARDSDR SIMA200227918Frame · corrodedDURING AN MFG INSPECTION, MAINTENANCE FOUND CORROSION ON LEFT OMEGA BEAM (PREVIOUS REPAIR) AT FRAME 20. REMOVED PREVIOUS REPAIR (CORROSION LIMITED TO PREVIOUS REPAIR ONLY). FABRICATED A DOUBLER ANGLE, FILLER, PLATE, AND TWO SHIMS. REPAIR DONE IAW MFG SRM ANSDR C2XA02IA198Sealant · looseIAH- ON CLIMB THE CREW NOTED THAT THE FO'S DV WINDOW SEALANT WAS FLAPPING ON THE FUSELAGE, THE AIRCRAFT RETURNED TO IAH, LANDED WITHOUT INCIDENT. MAINTENANCE IN CLE PERFORMED A REPAIR TO THE FIRST OFFICER'S DIRECT VISION WINDOW SEALANT. THE AIRCRAFT WAS RETUSDR C2XA02IA196Relay · inoperativeIAH- FLIGHT 3844, THE CREW NOTED THAT RUDDER SYSTEM #2 INOPERATIVE DURING INITIAL CLIMBOUT, THE AIRCRAFT RETURNED TO IAH, AND, LANDED WITHOUT INCIDENT. IAH- MAINTENANCE REMOVED AND REPLACED RELAY K0378, PERFORMED A OPERATIONAL CHECK, NO DEFECTS NOTED, AND, SDR C2XA02IA195Pressure Switch · inoperativeIAH- THE CREW NOTED THAT RUDDER SYSTEM #2 FAIL ON EICAS IN FLIGHT, THE AIRCRAFT RETURNED TO IAH, AND, LANDED WITHOUT INCIDENT. IAH- MAINTENANCE REMOVED AND REPLACED THE #2 RUDDER PRESSURE SWITCH, PERFORMED A OPERATIONAL CHECK, NO DEFECTS NOTED, AND, THE AIRSDR C2XA02IA194Pressure Switch · inoperativeIAH- THE CREW NOTED THAT RUDDER SYSTEM #2 FAIL ON EICAS IN FLIGHT, THE AIRCRAFT RETURNED TO IAH AND, LANDED WITHOUT INCIDENT. IAH- MAINTENANCE REMOVED AND REPLACED THE #1 RUDDER PRESSURE SWITCH, PERFORMED A OPERATIONAL CHECK , NO DEFECTS NOTED, AND, THE AIRSDR SIMA200226105Smoke Detector · malfunctionedORD - DURING FLIGHT CREW REPORTED THE BAGGAGE SMOKE LIGHT FLICKERED ON. CREW DISCHARGED FIRE BOTTLE AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REMOVED AND REPLACED THE SMOKE DETECTOR IAW EMB MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SDR C2XA02IA199Skin · lightning strikeIAH- ON CLIMB THE CREW REPORTED A LIGHTNING STRIKE. RETURNED TO IAH AND LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED A LIGHTNING STRIKE INSPECTION, NO DEFECTS NOTED. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA200227919Seat Track · corrodedABI - THIS IS A LEVEL 2 FINDING, INBOARD SEAT TRACK FOR SEAT 1A-4A WERE FOUND TO BE CORRODED. REMOVED AND REPLACED SEAT TRACK IAW EMB 145 AMM 53-01-06. (M)SDR SIMA200226102Floorbeam · corrodedABI - DURING IMBV INSPECTION, THE FORWARD DIGITAL IN THE GALLEY WAS FOUND TO BE CORRODED. CUT OUT DAMAGED PORTION ON THE DIGITAL, 16.5 BY 21, AND FABRICATED TWO DOUBLERS, ONE SHIM. REPAIR DONE IAW EMB 145, SRM 145/1142, REV 18 SRM 53-21-10, AND STANDARD SRM SDR C2XA02IA197Control Handle · malfunctionedCOS - PILOT REPORTED THAT UPON SELECTING GEAR UP THE LANDING GEAR DID NOT RETRACT. THE AIRCRAFT RETURNED TO COS AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS FERRIED TO IAH WHERE MAINTENANCE REMOVED AND REPLACED THE LANDING GEAR CONTROL LEVER. THE LANDING GSDR C2XA02IA193Control Unit · failedIAH- DURING FLIGHT 3642, AT CRUISE ALTITUDE THE CREW NOTED A FLAP FAIL MESSAGE AND RETURNED TO IAH AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE FLAP ELECTRONIC CONTROL UNIT, PERFORMED A OPERATIONAL CHECK OF THE FLAP SYSTEM AND NO DEFECTSSDR SIMA200226103Floorbeam · corrodedABI - DURING AN IMBV INSPECTION, FOUND CORROSION ON GALLEY RIGHT FLOOR BEAM. REMOVED CORRODED GALLEY RIGHT BEAM. INSTALLED NEW BEAM IAW EMB-145, SRM 145/1142, CHAPTER 51, RV 19, 51-40-02, AMERICAN EAGLE AIRLINES INC ETN NR EM-53-028 AND STANDARD SRM PRACTICESDR C2XA02CL183Connector · looseCLE FLIGHT NR 3027 THE CREW REPORTED THE EXIT LIGHT WAS INOPERATIVE ON THE GALLEY DOOR. MAINTENANCE INSPECTED AND RESECURED THE LOOSE CONNECTOR ON THE EXIT SIGN. OPERATIONAL CHECKS WERE GOOD.SDR C2XA02CL181Pump · failedCLE FLIGHT#3017 THE CREW REPORTED FUEL PUMP 1A FAILED IN FLIGHT.MAINTENANCE REPLACED THE FUEL PUMP.OPERATIONAL CHECKS WERE GOOD.THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR SIMA200227903Sill · corrodedABI - THIS IS A LEVEL 2 FINDING, LOWER CARGO DOOR SILL CORRODED. REMOVED AND REPLACED LOWER SILL IAW EMB 145 SRM 51-41-02. (M)SDR SIMA200227916Pin · corrodedTHIS A LEVEL 2 FINDING, HORIZONTAL STABILIZER PINS ARE CORRODED. REMOVED AND REPLACED PINS IAW EMB 145 AMM 55-10-00. (M)SDR SIMA200227911Floorbeam · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY AREA CENTER BEAM HAS CORROSION. INSTALLED REPAIR DOUBLER AND FILLER IAW EMB GST-1736/02C AND ETN EM 53-034R1. (M)SDR SIMA200225501Floorbeam · corrodedABI - FOUND GALLEY CENTER HAT BEAM CORRODED BEYOND LIMITS. INSTALLED NEW CENTER HAT BEAM IAW EMB145 SRM 145/1142 CHAPTER 51, REV 19, 51-40-02, 51-40-04, 51-20-01, 51-20-03 AND EMB GST-2758/02. (M)SDR AY52002F00001Flange · wornDURING "C" CHECK INSPECTION, THE RIGHT ELEVATOR WAS NOTED TO HAVE PLAY AT THE CENTER HINGE POINT. FURTHER INVESTIGATION REVEALED THE INBOARD HAT BUSHING HAD BACKED OUT OF THE FLANGE ALLOWING THE ELEVATOR TO HAVE 0.122 INCH PLAY AT THE HINGE. THE END OF THE HSDR SIMA200227904Floor Support · corrodedTHIS IS A LEVEL 2 FINDING, GALLEY CENTER BEAM GUSSET HAS CORROSION. INSTALLED SERVICEABLE GALLEY CENTER BEAM GUSSET IAW EMB 145 SRM 51-40-02. (M)SDR SIMA200227910Support · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY AREA RAMP SUPPORT HAS CORROSION. INSTALLED SERVICEABLE RAMP SUPPORT IN GALLEY IAW EMB SRM 51-40-02. (M)SDR SIMA200227909Crossbeam · corrodedABI - THIS IS A LEVEL 2 FINDING, GALLEY AREA AFT CROSSBEAM AND PROFILER HAS CORROSION. INSTALLED SERVICEABLE AFT CROSSBEAM AND PROFILE IAW EMB145 SRM 51-40-02. (M)
Back to Embraer EMB-145LR