Embraer EMB-145XR

Service difficulty reports · 9,191

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145XR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JJBA20220623032None · noneAT REAR FUSE II EXT, SUSPECTED CRACKS (14X) FOUND ON LH SIDE SKIN BTW FR 77-80 AND BTW STR 3R-9R. 7 BUSHING REPAIRS ON LH REAR FUSE 2 SKIN, AT FR 77-79 AND BTW STR 3L-9L. EXTERNAL GVI, AT REAPIR, INTERVAL OF 9000 FCJun 23, 2022 · N21154 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220622029None · noneDENT ON WING ROOT INSIDRE OF DENT ALREADY MAPPED ON LEADING EDGE. REPAIR DOUBLER ON LH WING LEADING EDGE #1, ON NOSE SECTION BTW INBD EDGE - RIB STA YS723.7Jun 22, 2022 · N21154 · Emb EMB145XR · Wing StructureSDR JJBA20220721017Web · crackedCOCKPIT RH OVERHEAD HORIZONTAL WEB CRACKED AT GRAB HANDLE SUPPORT. REPAIR DOUBLER ON RH FWD FUSE 2 WINDOW FLIGHT COMPARTMENT OVERHEAD PANELJun 21, 2022 · N12195 · Emb EMB145XR · Aerodynamic FairingsSDR JJBA20220621033Beam · crackedLH OMEGA BEAM FOUND CRACKED (X3) AT FR 21, FR 22. 3 REPAIR DOUBLES ON L/H CENTER FUSE 1 OMEGA BEAM, ON INBD FLANGE AT 21,22 &23Jun 21, 2022 · N12195 · Emb EMB145XR · Fuselage Floor PanelSDR JJBA20220621020Lamp · inoperativeFOUND COCKPIT CEILING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED COCKPIT CEILING EMERGENCY LIGHT LAMP. OPS CHECK GOOD.Jun 21, 2022 · N17169 · Emb EMB145XR · Emergency LightingSDR JJBA20220621019None · noneEMERGENCY FLOOR LIGHT STRIP DETACHED BY GALLEY. RESECURED EMERGENCY LIGHT STRIPJun 21, 2022 · N11150 · Emb EMB145XR · Emergency LightingSDR JJBA20210621018None · brokenFRAME EXIT SIGN BROKEN NEAR GALLEY. REMOVED AND REPLACED EXIT MARKING SIGN ASSEMBLY FRAME NEAR GALLEYJun 21, 2022 · N12175 · Emb EMB145XR · Emergency LightingSDR JJBA20220621016Placard · inoperativeFOUND GALLEY DOOR LOWER EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED GALLEY DOOR LOWER EMERGENCY LIGHT. OPS CHECK SAT.Jun 21, 2022 · N13202 · Emb EMB145XR · Emergency LightingSDR JJBA20220620034Door Frame · inadequateEXISTING REPAIR ON PAX DOOR LOWER FRAME NOT PROPERLY PERFORMED (DOUBLE DOESN'T FIT WELL). EDDY CURRENT INSPECTION CARRIED OUT ON CUTOUTS LINES (2X) AND SURROUNDING AREA, NO CRACKS FOUND. REPAIR ON PAX DOOR LOWER FRAME REDONE.Jun 20, 2022 · N12195 · Emb EMB145XR · DoorsSDR JJBA20220620028None · noneFR 25 CRACKED SIDE BEHIND RH SILL BTW STR 15R-16R. EXTENDED SPLICE REPAIR ON RH CENTER FUSE 2 FRAME 25, BTW STR 14R-16R. INTERNAL DETAILED VISUAL INSPECTION, AT REPAIR, INTERVAL OF 10000 FCJun 20, 2022 · N21154 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220620027None · noneSHEAR CLIP FOUND CRACKED AT RH FR 68 BTW STR 6-10. SHEAR CLIP AT FR 68 RH BTW STR 6-10 REPLACED WITH MADE REPAIR PART AND MASTER PARTJun 20, 2022 · N21154 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220620017None · noneCENTER FLOOR SUPPORT GUSSET CORRODED BTW FRA 59 & 61. REPAIR DOUBLER ON CENTER FUSE 4, ON CENTER OMEGA BEAM BTW FR 60-61Jun 20, 2022 · N21154 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220620009None · noneEXTERNAL FWD VENTRAL TANK DRAIN VENT SKIN CORRODED. REPAIR DOUBLER ON CENTER FUSE VENTRAL TANK RIB 1Jun 20, 2022 · N21154 · Emb EMB145XR · Flight Control SystemSDR JJBA20220620008None · noneSHEAR CLIP FOUND CRACKED AT FR 71 LH BTW STR 6-10. SHEAR CLIP AT FR71 LH BTW STR 6-10 REPALCED WITH MADE REPAIR PART.Jun 20, 2022 · N21154 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220619015None · inoperativeLH FWD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LH FWD EXTERNAL EMERGENCY LIGHT BULB. REMOVED AND REPLACED LH FWD EXTERNAL EMERGENCY LIGHT ASSEMBLY. OPS CHECK GOOD AT THIS TIME.Jun 19, 2022 · N12201 · Emb EMB145XR · Emergency LightingSDR JJBA20220619014None · inoperativeSMOKE SMELL FROM COCKPIT DURING DEP CLIMB OUT. REMOVED AND REPLACED SLEEVES BETWEEN DUAL TEMP CONTROL VALVE AND Y-DUCT ON #2 PACK VALVE. REMOVED AND REPLACED #2 ACM. O-RING BETWEEN TURBINE OUTLET DUCT AND ACM STILL NEEDS TO BE INSTALLED. INSTALLED O-RING. OPS/Jun 19, 2022 · N14143 · Emb EMB145XR · Air Conditioning SystemSDR JJBA20220618013None · noneO2 MASK WONT TEST. RESECURED O2 MASK BOX. OPS CHECK GOOD.Jun 18, 2022 · N24103 · Emb EMB145XR · Crew Oxygen SystemSDR JJBA20220618012None · noneFOUND COCKPIT STEP EMERGENCY EXIT LIGHT INOPERATIVE. FOUND HARNESS FOR COCKPIT STEP EMERGENCY LIGHT DISCONNECTED. RECONNECTED HARNESS. OPS CHECK SAT.Jun 18, 2022 · N27190 · Emb EMB145XR · Emergency LightingSDR JJBA20220617007None · noneLH FLOOR GUSSET FR 24-38 LBL 18 HAS CORROSION SEVERAL AREAS BETWEEN AND AROUND TRACKS. REPLACED FLOOR GUSSET FR 24-29, FR 36-39Jun 17, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220616011None · brokenSERVICE DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK FAILED. FOUND WIRE W716-0007-20 TO BE BROKEN. REPAIRED WIRE. OPS CHECK SATJun 16, 2022 · N11191 · Emb EMB145XR · Emergency LightingSDR JJBA20220616005None · noneCO-PILOT SEAT TRACKS HAS SIGNS OF CORROSION ON GUSSET. REMOVED DAMAGED DOUBLER SHEET FLOOR AND INSTALLED NEW DOUBLER SHEET FLOOR AT CO-PILOT FLOOR O/B GUSSETJun 16, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220615006None · noneSIGNS OF CORROSION AT FR58 STR 20R STRINGER HAS SIGNS OF CORROSION. REMOVED AND REPLACED STRINGER AT FR58-60, STR 20R. NO DEFECTS NOTED AT THIS TIME.Jun 15, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220613010None · inoperativeAC CABIN ALT RAPIDLY CLIMBED TO 8400 THEN 9000 FEET, CAB RATE CONTINUED TO -150. CAB ALT CONTINUED TO RISE. DID A RAPID DECENT AND EMERGENCY DECLARED. OPENED BOTH COCKPIT DV WINDOWS, INSPECTED SEALS, FOUND NO DEFECTS. THEN FULLY CLOSED BOTH WINDOWS. REMOVED ANJun 13, 2022 · N17138 · Emb EMB145XR · Cabin Pressure Control SystemSDR JJBA20220611003None · noneMID-CABIN AFT EMERGENCY CEILING LIGHT INOPERATIVE. RE-SECURED CONNECTIONS FOR MID-CABIN AFT EMERGENCY CEILING LIGHT. OPS CHECK SATJun 11, 2022 · N14174 · Emb EMB145XR · Emergency LightingSDR JJBA20220603035None · noneEXISTING REPAIR DOUBLE ON FWD PRESSURE BULKHEAD NEED TO BE REMOVED FOR INVESTIGATION. FWD PRESSURE BULKHEAD REPAIRED WITH DOUBLER.Jun 3, 2022 · N12195 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220602004None · noneAT REAR FUSE I EXT, CRACK FOUND ON RH TOP SKIN AT FR 75 AND BTW STR 1R-3R. CRACK ON RH TOP SKIN AT FR75 AND BTW STR 1R AND 3R REPAIRED WITH DOUBLER.Jun 2, 2022 · N21154 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220602002None · noneAT REAR USE II EXT, SUSPECTED CRACKS (17X) FOUND ON RH SIDE SKIN BTW FR 77-FR80 AND BTW STR 3R-9R. AFTER NDT INSPECTION 13 CRACKS CONFIRMED ON RH SIDE SKIN BTW FR77-80 STR 3R-9R. AT RFII (9X) CUTOUTS C/OUT ON RH SKIN BTW FR 77-80 STR 3R-9R. ITEM 5 (X9) BUSHINGJun 2, 2022 · N17169 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220601001None · noneCENTER FLOOR TRACKS HAVE CORROSION FR 25-43 BL0. REMOVED CORROSION AT CABIN SEAT TRACK BL0 FROM FR 25-43. EVALUATED SEAT TRACK FROM FR 26, 28, 33, 34, 36 AND 38-40 FOUND TO BE WITHIN LIMITS. EVALUATED SEAT TRACK FROM FR 25, 27, 29, 30-32, 35 AND 37 FOUND TO BEJun 1, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220531061None · noneBLEED 2 LEAK ON EICAS AND OVERHEAD PANEL. INSPECTED PACK 2. FOUND LARGE SLEEVE CONNECTED TO DUAL TEMP CONTROL VALVE NOT FULLY ON TUBE BUT NOT LEAKING. RE-SECURED LARGE SLEEVE CONNECTED TO DUAL TEMP CONTROL VALVE. PERFORMED COOLING PACK SYSTEM OPS TEST. OPS TESMay 31, 2022 · N16147 · Emb EMB145XR · Pneumatic SystemSDR JJBA20220531063None · noneFWD CABIN EMERGENCY LIGHT TRACK MISSING. INSTALLED EMERGENCY LIGHT STRIP AT SEAT 1AMay 31, 2022 · N14177 · Emb EMB145XR · Emergency LightingSDR JJBA20220531060None · noneLH CENTER FUSELAGE I HAS DENT FWD OF FRM 20 BELOW STGR 14. EVALUATED DENT DIM ARE L=1.20 W=.780 D=.030 NF-700 FOUND TO BE OUT OF LIMITS. RECONTOURED DENT LH FUSELAGE FR20 BELOW STR 14. REEVALUATED DENT L=.550 W=.40 D=.015 NF-800 AND DENT HAS SHARP EDGE FOUND TMay 31, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220531054None · noneSIGNS OF CORROSION ON FLOOR GUSSET AT FR59 TO FR60 APPROX LBL15. REMOVED AND REPLACED FLOOR GUSSET AT FR59 TO FR60 APPROX LBL 15May 31, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220530062None · noneEMERGENCY EXIT SIGN IN CABIN FALLING OFF (CENTER CEILING). RESECURED CENTER CABIN CEILING EMERGENCY EXIT SIGN. OPS CHECK SAT. NO FURTHER DEFECTS NOTED AT THIS TIMEMay 30, 2022 · N21197 · Emb EMB145XR · Emergency LightingSDR JJBA20220528059None · noneLARGE EMERGENCY EXIT SIGN IN GALLEY INOPERATIVE. REMOVED AND REPLACED EXIT MARKING SIGN AT GALLEY. OPS CHECK SATMay 28, 2022 · N14158 · Emb EMB145XR · Emergency LightingSDR JJBA20220527053None · noneAT REAR FUSE, CRACK FOUND ON RH TOP SKIN BTW FR 76 - FR 77 AT STR 2R. BUSHING REPAIR ON RH REAR FUSE 1 UPPER SKIN, BTW SKIN EDGE FR76 AND BTW STR 2R- 3RMay 27, 2022 · N17169 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220527052None · noneCF 4 UNDERFLOOR FR 59 BTW STR 19L - 19R CORROSION ON TOP FLANGE. SPLICE REPAIR ON CENTER FUSE 4 FR 59, BTW STR 20L-21L & BTW STR 20R - 21RMay 27, 2022 · N17169 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220527048None · noneAT REAR FUSE, CRACK FOUND ON LH TOP SKIN AT FR 75 BTW STR 2L-3L. REPAIR DOUBLER ON LH FUSE 1 UPPER SKIN AT FR 75 & BTW STR 1L-3May 27, 2022 · N17169 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220527058None · noneREMOVED BOTH PILOTS AND COPILOTS O2 MASKS BOX FOR FOM AND FOUND FITTINGS DISCONNECTED. RECONNECTED FITTINGS AND INSTALLED BOTH O2 MASK BOXES. OPS CHECK SATMay 27, 2022 · N11193 · Emb EMB145XR · Crew Oxygen SystemSDR JJBA20220526051None · noneAT REAR FUSE, CRACK FOUND ON RH TOP SKIN AT FR 75 BTW STR 2R - 3 R. REPAIR DOUBLER ON RH FUSE 1 UPPER SKIN, AT FR 75 & BTW STR 2R - 3 RMay 26, 2022 · N17169 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220526050None · noneAT REAR FUSE II EXT, SUSPECTED CRACKS (12X) FOUND ON LH SIDE SKIN BTW FR 77 - FR80 AND BTW STR 3R - 9 R. 8 BUSHING REPAIRS ON LH REAR FUSE 2 SKIN ON FR 77-78-79 AND BTW STR 3L-10L. REPAIR DOUBLERS ON LH FUSE SKIN. DOUBLER #1 ON FR 78 & BTW STR 5L-7L & DOUBLER May 26, 2022 · N17169 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220526049None · noneSUSPECTED CRACK ON LH BEAM AT FR33. REPAIR DOUBLER ON LH CENTER FUSE 2 OMEGA BEAM AT FRAME 33May 26, 2022 · N17169 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220526047None · noneLH WINDSHIELD HAS SIGNS OF CORROSION AT LOWER OUTBD FLANGE ON BACKSIDE. EVAL AREA AT LH WINDSHIELDS LOWER OUTBD FLANGE ON BACK SIDE, FWD ORIG THICKNESS .160" MAT LOSS .011" REMAINING MAT .149" ON AFT SIDE ORIG THICKNESS .160" MAT LOSS .018" REMAINING MAT .142 May 26, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220526046None · noneANGLE SHAPE FOUND CRACKED ON INBD SIDE OF MAIN FLOOR BEAM Y - 479.0 BTW STA 4154.5 & 5633.0. REMOVED AND REPLACED ANGLE AS REQUIREDMay 26, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220526057None · dimMCD EXTERNAL EMERGENCY LIGHT DIM/FLICKERING. REMOVED AND REPLACED MCD EXTERNAL EMERGENCY LIGHT. OPS CHECK SATMay 26, 2022 · N14203 · Emb EMB145XR · Emergency LightingSDR JJBA20220526056Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK SAT.May 26, 2022 · N27200 · Emb EMB145XR · Emergency LightingSDR JJBA20220525055None · seizedSMOKE AND FUMES IN THE COCKPIT AND CABIN. FOUND PACK 1 ACM TO BE SEIZED. REMOVED AND REPLACED LH ACM/ OPS CHECK GOOD.May 25, 2022 · N14188 · Emb EMB145XR · Air Conditioning SystemSDR JJBA20220525044None · noneAGING AIRCRAFT FINDING: FLOOR PANEL 231JF AFT SUPPORT AT MAIN DOOR HAS SIGNS OF CORROSION. REMOVED AND REPLACED 1EA SHAPE U SUPPORT AFT AT MAIN DOORMay 25, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220524045None · noneRF1 RH SHEAR CLIP CRACKED BTW STR 10R-9R FR68. SHEAR CLIP REPLACEDMay 24, 2022 · N17169 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220524043None · noneCF1 RH O-BEAM AT FR 23 CORROSION ON TOP. OMEGA BEAM REPAIRED AT FR23May 24, 2022 · N17169 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220523038None · inoperativeALL BATTERY 1 EMERGENCY LIGHTS ARE INOPERATIVE. TESTED BATTERY 1. BATTERY VOLTAGE WITHIN LIMITS. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY AND CHARGER #1. OPS CHECK SATMay 23, 2022 · N14148 · Emb EMB145XR · Emergency Lighting
Back to Embraer EMB-145XR