Embraer ERJ 170-100SU
Service difficulty reports · 2,953
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ERJ170100SU' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'ERJ170100SU' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A20100221Pin · unsecureCREW REPORTED L-2 DOOR WOULDN'T DISARM. OCM RE-SECURED SLIDE COVER PIN PER EMB AMM, THE DOOR THEN OPERATED NORMALLY.SDR R61A20100222Plate · crackedGENERATED WHILE A/C WAS IN HEAVY CHECK, MAINTENANCE REPORTED THAT THERE WAS A CRACK IN THE COMPOSITE PLATE, AT THE UPPER MOUNT OF L-1 EMERGENCY EVACUATION SLIDE. MAINTENANCE REMOVED AND REPLACED L-1 EMERGENCY EVACUATION SLIDE PER EMB AMM, OPS CHECK GOOD.SDR R61A20100217Indication Sys · malfunctionedCREW REPORTED L-2 DOOR ARMED INDICATION WASN'T GOING FULLY INTO THE WINDOW. MAINTENANCE PLACED ON MEL 52-70-01-3.SDR R61A20100223Windshield · crackedCREW REPORTED THE F/O WINDSHIELD STARTED TO CRACK WHILE IN FLIGHT. CREW RETURNED TO DEN AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE F/O WINDSHIELD PER EMB AMM.SDR R61A20100219Panel · corrodedWHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON RT SILL PANEL AT FR 89 TO FR 90. MAINTENANCE REMOVED AND REPLACED THE SILL PANEL PER THE EMB SRM. AC STILL OUT OF SERVICE FOR THE CHECK COMPLETION.SDR R61A20100218Panel · corrodedWHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON RT SHEAR PANEL FORM FR 87 TO FR 88. MAINTENANCE REMOVED AND REPLACED THE SHEAR PANEL PER THE EMB SRM. AC STILL OUT OF SERVICE FOR CHECK COMPLETION.SDR R61A20100216Battery · dischargedEMERGENCY EXIT LIGHT ABOVE THE R-1 DOOR WAS INOP, ALONG WITH THE FWD ENTRANCE EMERGENCY LIGHT. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY BATTERY, AND RE-SECURED CONNECTOR IN CEILING PANEL PER EMB AMM. A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100215Pin · corrodedWHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON LT AND RT PINTLE PINS ON NOSE LANDING GEAR. MAINTENANCE REMOVED AND REPLACED THE LT AND RT PINTLE PINS PER THE EMB AMM. AC STILL OUT OF SERVICE FOR HEAVY CHECK. (LT PIN P/N 170-70424-001 AND SDR R61A20100212Slide · unserviceableMAINTENANCE REPORTED, FOUND R-2 DOOR SLIDE IS COMING UNLACED, AND REPLACED IT PER EMB AMM.SDR R61A20100214Gusset · corrodedWHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON RT I BEAM GUSSET AT FR 90. MAINTENANCE REMOVED AND REPLACED THE GUSSET PER THE EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK.SDR R61A20100213Intercostal · corrodedGENERATED WHILE A/C WAS IN HEAVY CHECK, MAINTENANCE REPORTED LT INTERCOSTAL CORRODED IN SEVERAL AREAS, FR 87-88. MAINTENANCE REMOVED AND REPLACED INTERCOSTAL ON LT SIDE FR 87-88 IAW EMB 170 SRM 51-42-02.SDR R61A20100211Slide · unserviceableCREW REPORTED L-1 DOOR SLIDE UNLACED. MAINTENANCE REMOVED AND REPLACED L-1 DOOR EMERGENCY EVACUATION SLIDE PER EMB AMM. A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100210Sill · corrodedGENERATED WHILE A/C WAS IN 72 MONTH CHECK, CORROSION ON RT SILL FR 89-90. MAINTENANCE REMOVED AND REPLACED IAW EMB 170 SRM 51-43-02 AND SRM 51-41-01.SDR R61A20100209Gusset · corrodedGENERATED WHILE A/C WAS IN 72 MONTH CHECK, CORROSION ON CENTER GUSSET FR 90. MAINTENANCE REMOVED AND REPLACED CORRODED CENTER GUSSET AT FR 90 PER IAW EMB 170 SRM 51-42-01.SDR R61A20100208Gusset · corrodedGENERATED WHILE A/C WAS IN 72 MONTH CHECK, CORROSION ON LT CENTER GUSSET FR 90. MAINTENANCE REMOVED CORRODED LT CENTER GUSSET AT FR 90 AND INSTALLED SERVICEABLE GUSSET IAW EMB 170 SRM 51-41-02.SDR R61A20100207Beam · corrodedGENERATED WHILE A/C WAS IN 72 MONTH CHECK, CORROSION ON RT CENTER I-BEAM BETWEEN FR 85-86. MAINTENANCE REMOVED AND REPLACED UPPER SHEET PER EMB 170 SRM 51-43-02 AND SRM 51-41-01.SDR R61A20100206Structure · corrodedGENERATED WHILE A/C WAS IN 72 MONTH CHECK, WASTE ACCESS DOOR CUTOUT STRUCTURE HAS SIGNS OF CORROSION ON I/B FWD CORNER. MAINTENANCE CLEANED AND REMOVED CORROSION AND COMPLETED OPS CHECK IAW EMB 170 AMM 38-32-00.SDR R61A20100205Splice · corruptedGENERATED WHILE A/C WAS IN 72 MONTH CHECK, MAINTENANCE REPORTED CORROSION ON LT SPLICE GUSSET BETWEEN FR 87-88 (JUST AFT OF DOOR L-2). MTX REMOVED AND REPLACED LT GUSSET SPLICE JUST AFT OF L-2 DOOR FR 87-88 IAW EMB SRM 51-40-02 AND 51-42-02.SDR R61A20100204Intercostal · corrodedGENERATED WHILE A/C WAS IN 72 MONTH CHECK, MAINTENANCE REPORTED CORROSION ON CENTER INTERCOSTAL BETWEEN FR 87-88, AND REMOVED IT AND INSTALLED SERVICEABLE CENTER INTERCOSTAL PER EMB 170 SRM 51-42-02.SDR R61A20100203Damper · corrodedGENERATED WHILE A/C WAS IN 72 MONTH CHECK, MAINTENANCE REPORTED L-2 DOOR DAMPER WAS CORRODED BEHIND DOOR SURROUND. MAINTENANCE REMOVED AND REPLACED L-2 DOOR DAMPER PER EMB AMM.SDR R61A20100202Damper · corrodedGENERATED WHILE A/C WAS IN 72 MONTH CHECK, MAINTENANCE REPORTED R-2 DOOR DAMPER WAS CORRODED BEHIND DOOR SURROUND. MAINTENANCE REMOVED AND REPLACED R-2 DOOR DAMPER PER EMB AMM.SDR R61A20100201Battery Pack · dischargedCREW REPORTED THE COCKPIT EMERGENCY LIGHT WAS INOP. MAINTENANCE REPLACED THE EMERGENCY BATTERY PACK PER EMB AMM, OPS CHECK GOOD.SDR R61A20100200Unknown · malfunctionedCREW REPORTED THE MAIN CABIN DOOR WAS TOUGH TO OPEN. MAINTENANCE INSPECTED AND PERFORMED OPS CHECK ON L-1 DOOR PER EMB AMM, AND NO DEFECTS WERE FOUND.SDR R61A20100199Beam · corrodedWHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON RT CENTER I BEAM AT FR 87 TO FR 88. MAINTENANCE REMOVED AND REPLACED THE BEAM PER THE EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK.SDR R61A20100197Structure · dirtyCREW REPORTED R-2 WILL NOT DISARM. MTX CLEANED DOOR AROUND GIRT BAR AREA AND PERFORMED OPS CHECK PER EMB AMM, OPS CHECK GOOD.SDR UHLA2010051400048Seat Track · corrodedLEVEL 2, CORROSION FRAME 17 AT RT SEAT TRACK BEAM TOP CAP. R & R BEAM IAW SRM 51-41-01 AND 51-43-01.SDR UHLA2010051200050Shear Plate · corrodedLEVEL 2 CORROSION RT SHEAR PLATE BETWEEN FR87 AND FR88. R & R SHEAR PLATE IAW SRM 51-42-01.SDR R61A20100195Wire Harness · faultyCREW REPORTED SLAT FAIL AFTER TAKEOFF FROM PHL, DECLARED EMERGENCY AND RETURNED TO FIELD AT PHL WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT AND FOUND THE RT 3/4 SLAT HARNESS TO BE AT FAULT, AND REPLACED IT PER EMB AMM. A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100194Printed Ckt Board · defectiveMAINTENANCE REPORTED ALL RAINBOW LIGHTS WERE STUCK ON, CYCLE OF POWER WAS NO FIX. MAINTENANCE REMOVED AND REPLACED BOTH ATTD LIGHT PCB'S PER EMB AMM, OPS CHECK GOOD.SDR R61A20100192Battery · dischargedCREW REPORTED EMERGENCY LIGHTS WERE INOP. MAINTENANCE REMOVED AND REPLACED ELPU NR 2 PER EMB AMM, OPS CHECK GOOD. THE A/C WAS THEN RETURNED TO SERVICE.SDR R61A20100191Handle · lack of lubeCREW REPORTED R-2 DOOR WOULDN'T DISARM. MAINTENANCE LUBED VENT AND ARMING HANDLE PER EMB AMM, OPS CHECK GOOD.SDR R61A20100190Unknown · malfunctionedCREW REPORTED L-1 DOOR DISARMING LEVEL WAS INOP. MAINTENANCE PERFORMED OPS CHECK OF DOOR 5 TIMES PER EMB AMM, NEW CREW ATTEMPTED TO OPERATE THE DOOR AND OPS CHECK GOOD.SDR UHLA2010042900046Skin · crackedMAJOR REPAIR - VERTICAL STAB RT SIDE SKIN IS CRACKED JUST ABOVE AFT UPPER HOIST POINT. PERFORMED DEFINITIVE REPAIR ON RT UPPER VERT STAB IAW ETD2010-170/02797. REMOVED DAMAGED AREA IAW ETD, PERFORMED EDDY CURRENT ON CUTOUT, NO CRACK LINE INDICATIONS FOUND IAWSDR R61A20100186Pin · out of positionCREW REPORTED L-2 DOOR WOULDN'T LOCK/ARM PROPERLY. MAINTENANCE RESET PIN IN DOOR SLIDE COVER POSITION PER EMB AMM, OPS CHECK GOOD.SDR R61A20100183Girt Bar · disconnectedCREW REPORTED DOOR R-2 DISARM LEVER AND VENT FLAP LEVER WERE STICKING, MAKING THE DOOR DIFFICULT TO OPEN. MAINTENANCE RE-INSTALLED GIRT BAR PER EMB AMM, OPS CHECK GOOD.SDR R61A20100181Slide · failedMAINTENANCE PERFORMED A SCHEDULED JOB CARD FOR A DEPLOYMENT CHECK OF THE R1 DOOR SLIDE. UPON THE COMPLETION OF THE CARD THE SLIDE FAILED TO DEPLOY CORRECTLY. MAINTENANCE REMOVED AND REPLACED THE SLIDE ASSEMBLY, SERVICED THE DOOR ACTUATOR, ALL PER THE EMB AMMSDR R61A20100180Gusset · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON FLOOR GUSSET AT FR 90 RIGHT OF CENTER. MAINTENANCE REMOVED AND REPLACED GUSSET PER EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100178Flange · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON WASTE SERVICE PANEL ON INTERNAL FLANGE. MAINTENANCE REMOVED AND REPLACED WASTE SERVICE PANEL BOX ASSEMBLY PER EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100179Dampener · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON R2 DOOR DAMPNER. MAINTENANCE REMOVED AND REPLACED THE DAMPNER PER EMB AMM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100177Flange · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON WATER SERVICE PANEL INTERNAL FLANGE. MAINTENANCE REMOVED AND REPLACED INTERNAL FLANGE PER EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100176Shear Plate · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON SHEAR PLATES IN THE AFT GALLEY, LEFT P/N 170-65927-007, RIGHT P/N 170-91919-001, AND CENTER P/N 170-65928-001. MAINTENANCE REMOVED AND REPLACED SHEAR PLATES PER THE EMB SRM. AC STILL OUT OF SESDR R61A20100175Seat Track · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON RT SEAT TRACK BEAM IN AFT GALLEY. MAINTENANCE REMOVED AND REPLACED SEAT TRACK BEAM PER EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100174Seat Track · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON FWD GALLEY RT SEAT TRACK BEAM. MAINTENANCE REMOVED AND REPLACED RT SEAT TRACK BEAM PER THE EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100173Gusset · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON FLOOR GUSSET AT FR 90 AT WASTE TANK FORWARD MOUNT. MAINTENANCE REMOVED AND REPLACED GUSSET PER THE EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100172Gusset · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON FLOOR GUSSET AT FR 90 LEFT OF CENTER. MAINTENANCE REMOVED AND REPLACED FLOOR GUSSET PER THE EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100171Gusset · corrodedWHILE AC WAS IN FOR MID C CHECK, LEVEL TWO CORROSION WAS FOUND ON AFT GALLEY AFT MOUNT AT FR 90. MAINTENANCE REMOVED AND REPLACED MOUNT GUSSET PER EMB SRM. AC STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A20100169Seat Track · corroded*** GENERATED WHILE IN HEAVY CHECK *** MTX REPORTED LT SEAT TRACK BEAM IN AFT GALLEY HAD AREAS OF CORROSION. MTX REMOVED AND REPLACED LT SEAT TRACK BEAM IAW EMB SRM 51-40-028 AND 51-43-01.SDR R61A20100165Bearing · lack of lubeCREW REPORTED L-1 DOOR WAS HARD TO OPEN. MAINTENANCE LUBED BEARINGS AND GUIDES FOR L-1 DOOR PER EMB AMM. ENG ISSUED AN ENGINEERING INSTRUCTION TO RIG L-1 DOOR.SDR R61A20100164Control Rod · out of adjustCREW REPORTED L-1 DOOR DISARMING HANDLE WASN'T RAISING COMPLETELY. MAINTENANCE ADJUSTED PNEUMATIC ASSIST CONTROL ROD PER EMB AMM.SDR R61A20100163Slide · failedMX REPORTED R-1 DOOR FAILED IT'S OPS CHECK. MAINTENANCE REMOVED AND REPLACED THE R-1 DOOR SLIDE PER EMB AMM.
Back to Embraer ERJ 170-100SU