Embraer Executive EMB-505
Service difficulty reports · 1,956
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB505' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB505' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DJFA20190723001Starter Gen · inoperativeRIGHT (#2) STARTER / GENERATOR INOP. REMOVED FAILED STARTER GENERATOR INSTALLED AN OVERHAULED STARTER GENERATOR REF AMM 24-31-01. PERFORMED STARTER GENERATOR UNSCHEDULED REMOVAL INSPECTION REF EMM 05-50-00. OPSAND LEAK CHECK GOOD WITH NO DEFECTS NOTED P/N 400SSDR DXTA2019071902643Electronic Unit · unserviceableDURING CRUISE AT FL410, THE AMBER SWPS FAULT, FLAP FAIL, PTRIM BKP FAIL AND WHITE SPOILER FAULT CAS MESSAGES ILLUMINATED. WE COMPLIED WITH THE FLAP FAIL QRC AND DIVERTED TO KMCO. THE CONDITIONS WERE NIGHT, VMC. // SIGNOFF// UNABLE TO DUPLICATE DISCRENCY. REPLASDR DXTA2019071202605Electronic Unit · malfunctionedFLAP FAIL YELLOW CAS ILLUMINATED - FLAP FAIL YELLOW CAS MESSAGE ILLUMINATED IN FLIGHT AT CRUISE ALTITUDE. ACCOMPANIED BY SWPS FAULT YELLOW CAS MESSAGE, PTRIM BKP FAIL YELLOW CAS MESSAGE, AND SPOILER FAULT WHITE CAS MESSAGE. ALSO, YELLOW X?S ON THE FLAP AND PSDR E07A201912020005Precooler · crackedCRACKED RT PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.SDR DXTA2019062802551Ecu · malfunctionedFLAP FAIL YELLOW CAS ILLUMINATED - WHILE PASSING THROUGH FL230 THE YELLOW "FLAPS FAIL" CAS CAME ON ALONG WITH THE LOSS OF THE AUTO PILOT, AND CAS MESSAGES "SWPS FAULT" AND "PTRIM BKP FAIL" """ CORRECTIVE ACTION"""" REMOVED LEFT FLIGHT CONTROL ELECTRONICS FOR SDR DXTA2019062002541Module · burnedDURING MX EVENT FOUND COMPRESSOR DRIVE MODULE POWER TERMINAL AND ASSOCIATED CONNECTOR HEAT DAMAGED // SIGNOFF // REMOVED AND REPLACED COMPRESSOR DRIVE MODULE, PALLET IAW AMM 21-52-00 OPS CHECKED AND LEAK CHECKED GOOD. REMOVED AND REPLACED RECEIVER DRYER IAW MMSDR 2019FA0000186Wire Harness · brokenCABIN DOOR INDICATION HARNESS BINDS, STRESSES AND BENDS SEVERELY UNDER TOP STEP (FUSELAGE TO CABIN DOOR HINGING STEP) WHEN CABIN DOOR IS CLOSED CAUSING INDICATION HARNESS TO BREAK AND ILLUMINATING A FALSE WARNING ON CAS.SDR DXTA2019061762504O-Ring · leakingAROUND FL350 WE GOT A HYDRAULIC SYSTEM FAULT STATUS MSG, FOLLOW BY A NO DISPATCH STATUS MSG. DECENDING THROUGH FL240 THE NUMBER 1(LEFT) ENGINE FAILED. NO FIRE OR VIBRATION. WE FOLLOWED THE INFLIGHT ENGINE FAILURE QRC. TEMP STABILIZED AT 44 AND N1 ROTATION WASSDR CA190604003Engine · unknown(CAN) DURING TAKEOFF, HSDB FAULT AND ENG NO DISPATCH CAS MESSAGE ILLUMINATED. ENGINE INSTRUMENTS DISPLAYED YELLOW X FOR FEW SECONDS. CREW ABORTED THE TAKE-OFF BEFORE REACHING 30 KNOTS. TROUBLESHOOTING IS GOING ON.SDR DXTA2019052002416Computer · malfunctionedGEA 2 FAIL WHITE CAS ILLUMINATED - WHILE IN CRUISE FLIGHT. RECEIVED ENG NO DISPATCH CAS MESSAGE, FOLLOWED BY A-I E1 FAIL THEN GEA 2 FAIL CAS. ON APPROACH WE KNEW WE WOULD NOT HAVE RIGHT MAIN GEAR SAFE GREEN INDICATION SO ELECTED TO COMPLY WITH QRH FOR ABNORMALSDR XMXR20191211017Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.SDR DXTA2019050702362Wire · pulledBOTH MLG BRAKE - ON CONSECUTIVE LANDINGS WITH FIRM BRAKE APPLICATION, THE BRAKES DID NOT APPLY EFFECTIVELY RESULTING IN A MUCH LONGER LANDING ROLLOUT. CORRECTIVE ACTION, PERFORMED FUNCTIONAL TEST OF THE MAIN BRAKE SYTEM AND FOUND DURING FULL BRAKE PEDAL DEPLOYSDR DXTR2019051001Hydraulic Line · crackedDURING RIGHT ENGINE START NO HYDRAULIC PRESSURE WAS INDICATED. SHUT DOWN ENGINE AND FOUND HYDRAULIC FLUID LEAKING FROM UNDER AC. FOUND RT ENGINE HYD EDP PRESSURE LINE LEAKING AT HYD RES. SWAGED FITTING. REMOVED AND REPLACED HYDRAULIC LINE ASSEMBLY IAW MM 20-10SDR 2019F00212Starter Gen · failedAT CRUISE, INDICATION OF LOSS OF ELECTRICAL POWER OF THE #2 DC STARTER/GENERATOR. CREW ELECTED TO MAKE AN UNSCHEDULED PRECAUTIONARY LANDING AT KATL. UPON INSPECTION, THE STARTER GENERATOR WAS DISCOVERED TO BE INTERNALLY FAILED, AND HAD SHEARED ITS DESIGNED DRISDR DJFA20190503001Fcu · malfunctionedDURING DESCENT RECEIVED FLAP FAIL, PTRIM BKP FAIL, SWPS FAULT, AND SPOILER FAULT CAS MESSAGES. REMOVED AND REPLACED FCE NR 1 IAW MM 27-03-01. COMPLIED WITH RIGGING OF THE FLAP SYSTEM AND FLAP SYSTEM OPERATIONAL CHECK IAW MM 27-50-00. COMPLIED WITH PITCH TRIMSDR E07A201905020001Precooler · crackedDURING ROUTINE INSPECTION OF ENGINE BLEED AIR PRECOOLER. THE RT PRECOOLER INLET GUIDE VANE WAS FOUND WITH VANE DETACHED FROM CENTER SUPPORT PIN. THIS WILL CAUSE THE VANE TO EVENTUALLY BREAK OFF AND FALL ON TOP OF THE PRECOOLER BLOCKING COOLING AIR FROM PROPERLSDR CA190426014O-Ring · failed(CAN) DURING FLIGHT, THE LEFT HAND ENGINE OIL PRESSURE WENT INTO YELLOW ZONE AND THE PILOT PULLED BACK POWER WHERE THE OIL PRESSURE WENT BACK TO GREEN. AIRCRAFT CONTINUED WITH THE LANDING AND LANDED UNEVENTFULLY. AFTER LANDING AND DURING TAXIING, THE OIL PRESSSDR DJFA20190417001Sensor · faultyTROUBLESHOOT SPOILER FAULT & GRND SPOILER FAIL CAS MESSAGE. ACCOMPLISHED CMC DOWNLOAD AND DONWLOADED CMC INTERFACE FILES TO ACCESS TO MED OEM PAGE AND SENT SCREENSHOTS OF SPOILER SYSTEM SENSORS TO CONTACT CENTER FOR ANALYSIS. DURING TROUBLESHOOTING PER SL505-2SDR DXTA2019041822155Priority Valve · malfunctionedNLG LANDING GEAR EXTENSION DELAY - DURING GEAR EXTENSION, A THUD WAS HEARD AND FELT FROM THE RIGHR MAIN GEAR FOLLOWED BY ABOUT A 10 SECOND DELAY OF THE NOSE GEAR WHILE INDICATING A SQUARE AMBER BOX. PERFORMED REPLACEMENT OF PRIORITY VALVE (NEW) IAW P-300 AMM SDR DJFA20190408001Spoiler · malfunctionedAT FL450 ACTIVATED THE SPOILERS THEY CAME OUT THEN RETRACTED RIGHT AWAY. RECEIVED GRND SPLR FAIL CAS MESSAGE AND SPOILER FAULT CAS PERFORMED FIM TASK 27-66-00. PERFORMED MULTIPLE F/T OF SPOILER SYSTEM WITH NO DEFECTS NOTED. PER CUSTOMER REQUEST REPOSITIONED LSDR DJFA20190403001Unknown · malfunctionedFLAP FAIL, SPWS FAULT, SPOILER FAULT. PERFORMED CMC DOWNLOAD FINDING FAULT CODE27522041 AND 27020141. COMPLIED WITH FIM TASK 27-53-00-810-808 FINDING CONDITION TO BE TRANSITORY. PER CUSTOMER REQUEST SWAPPED FCE 1 AND FCE 2 IAW AMM 27-03-01. PERFORMED FLAP SYSSDR E07A201912020011Precooler · crackedCRACKED LH PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.SDR DJFA2019041726001Control Unit · defectiveAT CRUISE ALTITUDE (FL450) HAD YELLOW X FOR BOTH SPOILER AND PITCH TRIM INDICATIONS. ALSO THE PRIMARY PITCH TRIM WAS INOPERATIVE. WE HAD NO CAS MESSAGES UNTIL AFTER LANDING (SPWS FAULT). TROUBLESHOT SYSTEM. FOUND # 2 FCE TO BE DEFECTIVE. REMOVED AND REPLACESDR DJFA2019041722001Control Unit · failedBACKUP PITCH TRIM FAIL CAS MESSAGE ON PDFS. POWERED AIRCRAFT DOWN AND BACKUP, MESSAGE STILL THERE ON PDFS. REMOVED AND REPLACED #1 FCE AND ACCOMPLISHED ELECTRONIC RIGGING PROCEDURE. ACCOMPLISHED IAW PHENOM 300 AMM 27-03-00. OPS CHECKS GOOD IAW PHENOM 300 AMM 2SDR DJFA20190318001Valve · brokenWHILE IN CLIMB FLT LVL 400-430 HAD CAS MESSAGES DUCT 1 OVER TEMP COME ON AND WITHIN ONE MINUTE HAD CAS MESSAGE DUCT 2 OVERTEMP COME ON AS WELL. ACCOMPLISHED THE QRH PROCEDURE WITH RESULTING PAX O2 MASKS DEPLOYMENT. FOUND RAM AIR VALVE FLAPPER BROKEN. REMOVED SDR 4NSA2019FA0000067Starter Gen · shortedDURING CRUISE, FLIGHT CREW NOTICED A MODERATE VIBRATION COMING FROM THE BACK OF THE AIRCRAFT. AFTER FURTHER INVESTIGATION, THE CREW DETERMINED THAT THE VIBRATION WAS COMING FROM THE RT NACELLE. SHORTLY AFTER, THE CREW RECEIVED A RT GEN FAIL CASS MESSAGE AND THSDR DJFA201904171001Control Unit · malfunctionedAT CRUISE ALTITUDE (FL430) HAD YELLOW X FOR BOTH SPOILER AND PITCH INDICATIONS. ALSO SPWS FAULT CAS MESSAGE, AND MAIN TRIM WAS NOT WORKING. TROUBLESHOT, COMPLIED WITH CMC DOWNLOAD, IASP AND ADS OPS - CHECK OK REMOVED AND REPLACED FCE 2 PER MCC IAW AMM 27-03-SDR E07A20191202014Diverter · crackedCRACKED RH PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.SDR E07A201912020013Diverter · crackedCRACKED LH PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.SDR DJFA2019041705001Control Unit · failedGND SPLR FAIL CAS MESSAGE IN FLIGHT. REMOVED AND REPLACED FCE 2 UNIT AND PERFORMED SATISFACTORY RIGGING/OPERATIONAL TEST OF THE SPOILER SYSTEM PER EMB 505 AMM 27-03-01 P/N 462900-1017 S/N 0938SDR DXTA2019030402103Controller · defectiveBLEED 1 LEAK YELLOW CAS ILLUMINATED - BLEED 1 LEAK AMBER CAS MESSAGE ILLUMINATED IN CRUISE FLIGHT AT 13,000 FEET. THE BLEED 1 AND 2 SWITCHES AND XBLEED KNOB WERE SELECTED OFF IN THE APPROPRIATE SEQUENCE AS DIRECTED BY THE QRH PROCEDURE. THE BLEED 1 LEAK CAS MESDR DJFA201904023002Uplock · malfunctionedMISSED APPROACH AND DECLARED AN EMERGENCY DUE "LG LEVER DISAGREE" MSG AFTER SELECTING GEARDOWN. WITH A RED NOSE GEAR INDICATION. THE NOSE GEAR EXTENDED WITH A SAFE INDICATION AFTER PULLING THE FREE-FALL HANDLE. (ALL LANDING GEARS HAVE BEEN PINNED DUE TO EMERGESDR DJFA201904013001Control Unit · malfunctionedDIVERTED DUE TO YELLOW X IN THE BOX UNDER SPOILER AND 2 MORE YELLOW X'S OVER PITCH TRIM INDICATOR RANGE AND NUMNERICAL VALUE AT FL430. DURING DECENT AP PITCH MISTRIM CAS MESSAGE APPEARED AND APPROPRIATE CHECK LIST FOLLOWED. AIRCRAFT LANDED WITHOUT INCIDENT. RESDR E07A201912020007Precooler · crackedCRACKED LH PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.SDR E07A201902270001Trim System · malfunctionedDESCENDING THROUGH APPROXIMATELY 10,000’ CREW RECEIVED A AP ROLL MISTRIM. CREW CORRECTED THE TRIM BASED ON THE ARROW IN THE TRIM WINDOW OF THE MFD AND SHORTLY THERE AFTER CREW RECEIVED YAW MISTRIM CAS. THESE TRIM CAS MESSAGES BECAME MORE IN MORE FREQUENT OVER SDR DXTA2019021802035Uplock · contaminatedLOUD BANG WHEN SELECTED DOWN AND 8-10 SECONDS FOR GREEN INDICATION. BLED THE AIR FROM THE LANDING GEAR UPLOCK BOXES. CHECKED & ADJUSTED HYDRAULIC ACCUMULATOR NITROGEN CHARGE REDUCING PRECHARGE PRESSURE. PERFORMED FUNCTIONAL CHECK ON THE LANDING GEAR EXTENSSDR DXTA2019021862034Control Unit · malfunctionedBRK FAIL YELLOW CAS ILLUMINATED - BRK FAIL YELLOW CAS MESSAGE IN FLIGHT. COMPLRETED CHECKLIST AND DIVERTED. INSPECTED BCU CANNON PLUG, NO DEFECTS NOTED. PERFORMED BCU FUNCTIONAL CHECK AND NOTED LH BRAKE PRESSURE TO BE VERY IRRATIC AND SHOWING BETWEEN 15-555 PSDR 2019F00130Warning Message · false activationAIRCRAFT DURING REQUESTED DESCENT HAD SWPS FAULT ANNUNCIATOR ILLUMINATED, ALONG WITH THE MAX SPEED FLAG AT THE TOP OF THE AIRSPEED TAPE. AIRCRAFT DESCENT IN EMERGENCY. AIRCRAFT LANDED SAFELY. ON GROUND WEST STAR TECHNICIANS PERFORMED SWPS STALL TEST SWITCH (PRSDR DXTA2019020101968Uplock · defectiveNLG LANDING GEAR EXTENSION DID NOT EXTEND - AFTER SELECTING FLAPS 2 WE COMMANDED GEAR DOWN WITH LEVER DOWN . THE TWO
MAIN CAME DOWN SHOWING GREEN CIRCLES ON MFD BUT THE NOSE GEAR AFTER OVER 30SEC NEVER SHOWED A GREEN CIRCLE . NOSE GEAR
SYMBOL WAS INITIALLY ASDR DXTA2019012801951None · noneWHEN LANDING GEAR LEVER SELECTED DOWN LG LEVER DISAG CAS MESSAGE APPEARED. NLG DID NOT EXTEND VERIFIED BY POSITION LIGHTS AND THE TOWER. EXECUTED QRH PROCEDURE AND ALL THREE LANDING GEAR EXTENDED. LANDED WITHOUT FURTHER INCIDENT. TROUBLESHOT NLG IAW EEJS CASDR DJFA2019040317002Valve · failedDIVERTED DUE TO DUCT 1 OVER TEMP CAS MESSAGE ILLUMINATED AT FL410. WHILE CONDUCTING QRH PROCEDURES, DUCT 1 OVER TEMP AND DUCT 2 OVERTEMP CAS MESSAGES ILLUMINATED CONDUCTED QRH PROCEDURE DESCENDED TO 10,000 FT PER PROCEDURE. AIRCRAFT LANDED WITHOUT INCIDENT. RESDR DJFA20190127001Trim System · malfunctionedIN FLIGHT WE HAD SWPS FAULT CAS AND SPOILER FAULT CAS ONLY. ON THE MFD IN YELLOW "X" FLAP POSITION, FLAP INDICATION AND PITCH TRIM FLAPS STAYED AT ZERO AND WOULD NOT EXTEND. PITCH TRIM WORKED/ BACKUP PITCH TRIM DIDN'T WORK. AIRCRAFT LANDED WITHOUT INCIDENT. COSDR DXTA2019011501913Warning System · false activationSWPS FAULT YELLOW CAS ILLUMINATED - DURING INITIAL DESCENT FROM CRUISE FLIGHT, WE HAD MULTIPLE CAS FAIL AND FAULTS LIGHTS INCLUDING PTRIM BKP FAIL, SWPS FAULT, TRIM FAIL, SPOILER FAULT. AS WELL, NO MATTER THE SPEED, THE AIRCRAFT WAS INDICATING A FLASHING MAXSPSDR XMXR20191211004Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.SDR DJFA20190106001Starter Gen · malfunctionedWHILE INFLIGHT WE FELT A VIBRATION IN THE AIRCRAFT AFTER 10-15 MINUTES RIGHT GENERATOR OFF LINE CAS MESSAGE, FOLLOWING CHECKLIST AND LANDED EYW. MX ASK US TO DO A RESET AND START ENGINES. UNSUCCESSFUL. WHILE INFLIGHT WE FELT A VIBRATION IN THE AIRCRAFT AFTER 1SDR XMXR2020121402Shutoff Valve · failedECS VALVE 1 FAIL.SDR DJFA20181229001Not Reported · malfunctionedDIVERTED DUE TO AT FL450 THE "SHED BUSS OFF" CAS MESSAGE FOLLOWED BY " GEN 1 OFF BUSS" CAS MESSAGE. THERE WAS BOTH UNUSUAL NOISE AND VIBRATION SO WE SHUT THE NR 1 ENGINE DOWN IAW THE CHECKLIST. AIRCRAFT LANDED WITHOUT INCIDENT.SDR DXTA2018122801842Unknown · malfunctionedNOSE GEAR WOULD NOT EXTEND. FOLLOWED CHECKLIST AND PERFORMED MANUAL EXTENSION. TOWER VERIFIED ON FLY BY THAT THERE WAS NO NOSE GEAR EXTENDED. "SUPPLEMENTAL INFORMATION" PERFORMED VISUAL INSPECTION OF NOSE GEAR, NOSE GEAR UPLOCK ASSY AND PROXIMITY SENSORS WITH SDR DJFA20181226002Starter Gen · malfunctionedDIVERTED DUE TO VIBRATION NOTICED FOLLOWED BY A "GEN 1 OFF BUS" CAS. NR 1 ENGINE WAS THEN SHUT DOWN IAW CHECKLIST. AIRCRAFT LANDED WITHOUT INCIDENT. R&R STARTER/GEN AND COMPLIED WITH 05-50-02 UNSCHEDULED STARTER/GEN REMOVAL INSP WITH NO DEFECTS NOTED.SDR DJFA20181226001Starter Gen · failedDIVERTED DUE TO ENGINE VIBRATION FOLLOWED BY GEN FAIL. SHUT DOWN NR 2 ENGINE PER THE CHECKLIST. DECLARED AN EMERGENCY. AIRCRAFT LANDED SAFELY. R&R NR 2 STARTER/GENERAL AND C/W UNSCHEDULED STARTER/GENERATOR SPECIAL INSPECTION. ALL CHECKS NORMAL.
Back to Embraer Executive EMB-505