Service difficulty report · Priority Valve · Emb EMB505

Difficulty date
April 12, 2019
Submitted
April 18, 2019
Operation
Air carrier
Aircraft
N363QS
Make and model
Emb EMB505
Aircraft serial
50500256
Aircraft time
3,390 hours, 2,715 cycles
Part
Priority Valve
Part number
22170001401
Part serial
00053
Condition
Malfunctioned
Location
Nlg
Stage of operation
LD
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NLG LANDING GEAR EXTENSION DELAY - DURING GEAR EXTENSION, A THUD WAS HEARD AND FELT FROM THE RIGHR MAIN GEAR FOLLOWED BY ABOUT A 10 SECOND DELAY OF THE NOSE GEAR WHILE INDICATING A SQUARE AMBER BOX. PERFORMED REPLACEMENT OF PRIORITY VALVE (NEW) IAW P-300 AMM 29-15-05