Mcdonnell Douglas DC-9-51
Service difficulty reports · 4,581
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC951' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC951' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR NWAA083439884Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 9-13 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (A)SDR NWAA083429876Battery · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 23-26 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE ASSOCIATED FUSE AND INSTALLED NEW BATTERIES IN THE POWER SUPPLY. OPERATIONAL CHECK WAS GOOD. (A)SDR NWAA083149869Connector · looseDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN HAD FAILED. MAINTENANCE FOUND A LOOSE ELECTRICAL CONNECTOR. RE-SEATED THE CONNECTOR AND OPERATIONAL CHECK WAS GOOD. (A)SDR NWAA083109880Diode · failedDURING THE LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5-8 OF THE CABIN WERE INOPERATIVE. MAINTENANCE REPLACED THE "DIODE IN THE FWD RT HAND OVERWING EXIT IDENT". OPERATIONAL CHECK WAS GOOD. (A)SDR NWAA083079865Power Supply · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN HAD FAILED. MAINTENANCE REPLACED THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONALLY CONDITION. (A)SDR NWAA083039853Relay · failedDURING THE LINE CHECK, MAINTENANCE FOUND THAT THE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY AND RELAY R2-271 BUT NEITHER PROCEDURE CORRECTED THE FAULT. AFTER RELAY R2-49 WAS REPLACED THE EXTERIOR EMERGENCY LIGHT FUSDR NWAA083049865Power Supply · inoperativeDURING THE LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN HAD FAILED. MAINTENANCE REPLACED THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (A)SDR NWAA082859864Controller · malfunctionedJUST AS THE AIRCRAFT TOOK OFF, THE COCKPIT CREW DETECTED SMOKE AND FWD LAVATORY SMOKE DETECTOR ACTIVATED. CREW REPORTED "EXTREME HEAT" AND SMOKE FILLED CABIN AREA. RED-BORDER COM PROCEDURES WERE COMPLIED WITH AND ACFT RETURNED TO CMH WITH CFR STANDING-BY. CSDR NWAA082849851Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 19-22 OF THE CABIN AND IN THE TAIL COMPARTMENT WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES IN THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (A)SDR NWAA082789876Connector · disconnectedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGN LIGHT FOR THE FWD RT OVERWING HATCH WAS INOPERATIVE. MAINTENANCE FOUND THE WIRE RECEPTACLE UNPLUGGED. AFTER CONNECTOR WAS RE-SECURED THE LIGHTS FUNCTIONED WITHOUT PROBLEM. (A)SDR NWAA082719863Battery Pack · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGN LIGHT PACK FOR THE FWD RT OVERWING HATCH WAS BROKEN. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (A)SDR NWAA082699863Battery Pack · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGN LIGHT PACK FOR THE AFT RT OVERWING HATCH WAS BROKEN. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (A)SDR DALA12007590861Angle · crackedDURING H CHECK, THE RT STA 83 ANGLE WAS FOUND CRACKED WHILE PERFORMING AN INSPECTION IAW EM5300-01041-08B. ACCOMPLISHED PERMANENT REPAIR AT COCKPIT WINDOW SILL BS 83.550 RT ANGLE FASTENERS REPLACEMENT IAW ERA 498419-14AD REV ORIGINAL SECTION 1.SDR NWAA082579867Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGN LIGHTS FOR THE FWD OVERWING HATCHES WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. (A)SDR NWAA082559867Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE TAIL COMPARTMENT HAD INOPERATIVE LIGHTS FOR THE CATWALK. MAINTENANCE REPLACED THE BATTERIES. OPERATIONAL CHECK WAS GOOD. (A)SDR NWAA082669881Attach Angle · crackedDURING LINE CHECK FOUND CRACK IN THE RT DORSAL FIN ATTACH ANGLE AT BS 1266. REPAIRED PER EA 98-213301. (A)SDR NWAA082659881Skin · crackedDURING LINE CHECK FOUND CRACK IN FUSELAGE SKIN AT BS 1266 LT BELOW VERTICAL STABILIZER ATTACH ANGLE. REPAIRED PER EA 98-213119. (A)SDR NWAA082409858Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGN LIGHT FOR THE FWD LEFT OVERWING HATCH WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY AT ROW 14 AND THE TRANSFORMER AT ROW 14-15. OPERATIONAL CHECK WAS GOOD.SDR NWAA082329855Power Supply · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE RIGHT SIDE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND OPERATIONALLY CHECKED THE SYSTEM.SDR NWAA082159886Battery Pack · inoperativeDURING LINE CHECK, THE EMERGENCY PATHWAY LIGHTING AT ROWS 5, 6, 7,AND 8 WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS IN THE ROWS SPECIFIED RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA082039863Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGN LIGHT FOR THE FWD LEFT OVERWING HATCH WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE EXIT LIGHT RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA082079880Manifold · leakingDURING TAKEOFF ENGINE NR 2 EPR ROLLED BACK FROM 2.17 TO 2.10. FLIGHT CREW ADVANCED ENG NR 2 THROTTLE TO STOPS BUT EPR REMAINED AT 2.10. AFTER TAKEOFF ENGINE NR 2 APPEARED TO FUNCTION NORMAL REMAINDER OF FLIGHT. AT DESTINATION MAINTENANCE NOTICED ENG NR 2 EXSDR NWAA082049884Fuse · failedAS THE AIRCRAFT WAS BEING PUSHED BACK FOR DEPARTURE, THE RIGHT HYDRAULIC SYSTEM LOST ALL FLUID. COM PROCEDURES WERE COMPLIED WITH AND THE AIRCRAFT RETURNED TO THE GATE WITHOUT ANY FURTHER PROBLEM. MAINTENANCE FOUND A HYDRAULIC FUSE IN THE RIGHT WHEEL WELL HASDR NWAA081969885Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 9 AND 13 OF THE CABIN GO DIM AFTER ABOUT 3 SECONDS. MAINTENANCE REPLACED THE BATTERY PACK AT THE OVERWING FWD LEFT EXIT LIGHT ASSEMBLY. LIGHTS RETURNED TO NORMAL FUNCTION AND OPSDR NWAA081979885Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 12 AND 19 OF THE CABIN GO DIM AFTER ABOUT 3 SECONDS. MAINTENANCE REPLACED THE BATTERY PACK AT THE OVERWING AFT LEFT EXIT LIGHT ASSEMBLY. LIGHTS RETURNED TO NORMAL FUNCTION AND OSDR NWAA081959885Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 5 AND 8 OF THE CABIN GO DIM AFTER ABOUT 3 SECONDS. MAINTENANCE REPLACED THE BATTERY PACK AT THE OVERWING FWD RIGHT EXIT LIGHT ASSEMBLY. LIGHTS RETURNED TO NORMAL FUNCTION AND OPSDR NWAA081899885Power Supply · dischargedDURING LINE CHECK THE EMERGENCY OVERWING EXIT SIGNS AT ROW 19, 20, 21 AND 22 WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE ASSOCIATED FUSE AND BATTERY, NEITHER CORRECTED THE PROBLEM. THE POWER SUPPLY WAS CHANGED AND THE SYSTEM CHECKS NORMAL.SDR NWAA081889873Unknown · smokeAFTER TAKEOFF FLT ATTENDANT REPORTED SMOKE IN CABIN. FLT CREW COMPLIED WITH COM PROCEDURES FOR SMOKE REMOVAL & INITIATED A RETURN. PILOTS NOTED RT AC SYS INDICATING FULL HOT IN AUTOMATIC MODE, TRIED FULL COLD IN AUTO MODE. VALVE POSITION REMAINED IN FULL HOSDR NWAA081799869Line · chafedFIRST OFFICER NOTICED THAT THE RIGHT HYDRAULIC SYSTEM QUANTITY WAS LOSING FLUID. COM PROCEDURES WERE COMPLIED WITH AND THE CREW ALSO DECLARED AN EMERGENCY IN ANTICIPATION OF NEEDING CFR EQUIPMENT. THE LANDING GEAR EXTENDED NORMALLY HOWEVER HYDRAULIC QUANTITY DSDR NWAA081669853Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA081619860Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE TAILCONE AND FOR THE VENTRAL STAIRWAY WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK (B5-28) AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA081659886Actuator · malfunctionedFLIGHT CREW REMARKED THAT THE AIRCRAFT WANTED TO ROTATE ON ITS OWN PRIOR TO V1 AND THAT A NOTICEABLE VIBRATION IN THE YOKE WAS FELT AFTER TAKEOFF. AIRCRAFT LEVELED AT 16000 FEET AND CREW ESTABLISHED COMMUNICATION WITH MAINTENANCE CONTROL. FLIGHT WAS DIRECTEDSDR DALA12015750875Skin · dentedHFEC DENT BS 503 AND LONGERON 24LT. FUSELAGE SKIN 4 INCHES AFT OF BS 503 AND 2.5 INCHES ABOVE L24L SKIN HAS DENT L=1", W= 1", D= .015, FOUND TO BE IN LIMITS IAW SRM 53-04, FIG 38 COND. 1B. HFEC INSP. IAW NDTSPM 06-10-01.001, NO CRACKS NOTED AT DENTED AREA.SDR NWAA081509872Battery Pack · inoperativeDURING LINE CHECK, THE EMERGENCY OVERWING EXIT SIGNS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK (B5-49) AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA081529859Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING IN THE COCKPIT WAS INOPERATIVE. MAINTENANCE REPLACED COCKPIT EMERGENCY LIGHTING BATTERY PACK AND LIGHTS RETURNED TO AN OPERATIONAL CONDITION.
SDR NWAA081549884Fuse · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE FIRST CLASS SECTION OF THE CABIN HAD FAILED. MAINTENANCE REPLACED THE ASSOCIATED FUSE IN THE PERTINENT POWER STRIP. OPERATIONAL CHECK WAS GOOD.SDR NWAA081539861Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY FLOOD LIGHT FOR THE AFT EVACUATION SLIDE WAS NOT FUNCTIONAL. MAINTENANCE FOUND THE BATTERY PACK B5-28 FAULTY AND REPLACED IT. OPERATIONAL CHECK WAS GOOD.
SDR NWAA080529859Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING IN THE COCKPIT WAS INOPERATIVE. MAINTENANCE REPLACED COCKPIT EMERGENCY LIGHTING BATTERY PACK AND LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR DALA12015730875Skin · dentedFUSELAGE EXTERIOR SKIN BS 237 BETWEEN 18LT AND 17LT, SKIN HAS AREA OF DENTS WHICH ARE OUT OF LIMITS DUE TO PROXIMITY. GAINED ACCESS. CUTOUT DAMAGED SECTION STA 212 TO 229 14" X 12.25" AND FROM STA 229 TO 237 12" X 9". FABRICATED AND INSTALLED 2EA DOUBLERS FRSDR NWAA081439883Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EXTERIOR EMERGENCY FLOOD LIGHT WERE INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK AND LIGHTS. RETURNED TO AN OPERATIONAL CONDITION.SDR NWAA081379863Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES FOR THE EMERGENCY LIGHTS IN THE TAIL COMPARTMENT CATWALK. OPERATIONAL CHECK WAS GOOD.SDR NWAA081359852Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY OVERWING EXIT SIGNS ON ROWS 11, 13, AND 14 WERE INOPERATIVE. THE POWER SUPPLY/BATTERY PACK WAS REPLACED AND SYSTEM CHECKS NORMAL.SDR NWAA081289876Hose · separatedTHE FLIGHT ATTENDANT REPORTED A THIN HAZE OF SMOKE AND A BURNING RUBBER SMELL IN THE CABIN. FLIGHT CREW NOTED THE SAME IN THE COCKPIT. THE SMOKE QUICKLY DISSIPATED SO THE FLIGHT CONTINUED TO SCHEDULED DESTINATION. LANDING AT DTW WAS NORMAL AND PASSENGERS DESDR NWAA081139851Charger · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY FLOOD LIGHT FOR THE AFT EVACUATION SLIDE WAS NOT FUNCTIONAL. THE BATTERIES IN THE CHARGER PACK B5-28 WERE REPLACED AND THE LAMP WAS REPLACED. FUNCTIONAL CHECK WAS GOOD.SDR NWAA081129865Light · malfunctionedDURING LINE CHECK, MAINTENANCE FOUND THAT THE RIGHT SIDE EXTERIOR EMERGENCY FLOOD LIGHT WAS INOPERATIVE. THE POWER SUPPLY WAS INITIALLY REPLACED BUT THAT DID NOT CORRECT THE DISCREPANCY. SYSTEM WAS PLACED ON MEL 33-20. LATER, MAINTENANCE WAS UNABLE TO DUPLISDR NWAA081149875Web · crackedDURING ENGINE CHANGE, FOUND CRACKS IN LT PYLON CLOSURE WEB AT STA YN 135. REPAIRED PER EA 98-211617.SDR NWAA081559861Power Supply · inoperativeDURING LINE CHECK, THE EMERGENCY OVERWING EXIT SIGNS AT ROWS 10, 11, AND 12 WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY EXIT LIGHT POWER SUPPLY AND OPERATIONALLY CHECKED THE SYSTEM.SDR NWAA081269858Skin · crackedDURING "H" CHECK, FOUND CRACK IN LT FUSELAGE SKIN AT THE UPPER FORWARD CORNER OF PASSENGER ENTRY DOOR 1L JAMB. REPAIRED PER EA 98-212124 SECTION I. SECTION II REQUIRES REPETITIVE INSPECTIONS EVERY 3,000 CYCLES. SECTION III PERMANENT REPAIR TO BE ACCOMPLISHESDR NWAA080659852Battery Pack · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE VENTRAL STAIRWAY WAS INOPERATIVE. MAINTENANCE REPLACED THE POWER PACK AND OPERATIONALLY CHECKED THE SYSTEM. THE AIRCRAFT HAS RETURNED TO SERVICE.SDR NWAA081209858Stiffener · crackedDURING "H" CHECK, FOUND CRACK IN OUTBOARD LOWER END OF AFT LEFT LAVATORY NR 1 HORIZONTAL STIFFENER AT AFT PRESSURE BULKHEAD. REPAIRED PER EA 98-212123.
Back to Mcdonnell Douglas DC-9-51