Mcdonnell Douglas DC-9-82

Service difficulty reports · 23,866

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC982'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20030684Light · inoperativeDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT SEAT PATH FORWARD RED LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT SEAT PATH LIGHT. SYSTEM GORUND CHECKED NORMAL OPERATION. (M)Jun 23, 2003 · N14551 · Doug DC982 · Emergency LightingSDR AALA20030683Battery · corrodedDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS IN TAIL COMPARTMENT VERY DIM. CLEANED EMERGENCY EXIT LIGHT BATTTERIES FOR TAIL COMPARTMENT LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jun 23, 2003 · N490AA · Doug DC982 · Emergency LightingSDR GTIA030507Web · corrodedFTW - FOUND CORROSION ON L1 DOOR WEB, STATION 200 LOWER FORWARD CORNER LBL 54. REMOVED APPROX 8 INCHES FROM LOWER L1 DOOR WEB. FABRICATED L1 DOOR REPAIR. INSTALL REPAIR ON L1 DOOR WEB. (M)Jun 23, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030504Floor Support · corrodedFTW - FOUND FORWARD CABIN STATION 185 TO 195 LBL 52 INCHES FLOOR SUPPORT CORRODED. REMOVED FLOOR SUPPORT. DRILLED AND LOCATED NEW FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)Jun 23, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030503Web · crackedFTW - FOUND FORWARD CABIN STATION 218 TO 236 LBL 44 INCHES TO 54 INCHES CRACK FORWARD SIDE CORNER WEB. REMOVED DAMAGED SECTION OF WEB. FABRICATED REPAIR. INSTALLED REPAIR. (M)Jun 23, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030515Floor Support · corrodedFTW - FORWARD CABIN STATION 160 TO STATION 200 LBL 54 INCHES CORRODED AT THE FLOOR SUPPORT. REMOVED FLOOR SUPPORT. LOCATED AND DRILLED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)Jun 23, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030489Structure · crackedSUBFLOOR HAS 1 INCH DIAMETER CRACK AT STATION 150 RBL 30. CUTOUT DAMAGED AREA, FABRICATED DOUBLER REPAIR. INSTALLED DOUBLER. (M)Jun 23, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR CALA0300333Battery Pack · inoperativeINSPECTION FOUND THE OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. THE BATTERY PACK WAS REPLACED AND OPERATIONAL CHECKS WERE GOOD IAW MM 33-53-00, PAGE 407.Jun 23, 2003 · N92874 · Doug DC982 · Emergency LightingSDR AALA20030677Control Valve · leakingBOS - FLT 1201 - EN ROUTE BOS-DFW, DURING CLIMB-OUT, RIGHT HYDRAULIC PRESSURE LOW LIGHT ILLUMINATED. RIGHT HYDRAULIC SYSTEM HAD TOTAL LOSS OF FLUID, UNABLE TO RETRACT LANDING GEAR. RETURNED BOS AND LANDED WITHOUT INCIDENT. REPLACED ANTI-SKID CONTROL VALVE. Jun 22, 2003 · N218AA · Doug DC982 · Brake Anti-Skid SectionSDR GTIA030562Floor Support · corrodedFTW - FOUND FORWARD ENTRY AREA, FLOOR SUPPORT AT STATION 160 LBL 4 TO RBL 4 IS CORRODED. FABRICATED NEW FLOOR SUPPORT. (M)Jun 22, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030516Floor Support · corrodedFTW - FOUND FORWARD ENTRY AREA, FLOOR SUPPORT STATION 160 TO 200 RBL 48 CORRODED. FLOOR GALLEY MOUNT CORRODED AT STATION 160 RBL 48. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)Jun 22, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR CALA0300326Longeron · corrodedINSPECTION FOUND LONGERON 22R CORRODED AND SKIN BULGING AT STA 168. THE LONGERON SECTION WAS REMOVED AND REPLACED IAW SRM 53-02, PAGE 1-2 AND 53-02, PAGE 48-50.Jun 21, 2003 · N33817 · Doug DC982 · Fuselage Main, Longeron/StringerSDR ASAA0380505Module · inoperativeEMERGENCY TRACK LIGHTING INOPERATIVE AT ROW 29. REPLACED LIGHT MODULE (HOLDER AND LAMP). LIGHTS THEN OPERATED PROPERLY. (M)Jun 20, 2003 · N931AS · Doug DC982 · Emergency LightingSDR GTIA030525Web · corrodedFTW - AFT CARGO COMPARTMENTS AT STATIN 1218, LONGERON 18R, SUB FLOOR WEB IS CORRODED. SUB FLOOR WEB. DRILLED AND LOCATED SPLICE AND ODUBLER. INSTALLED WEB SPLICE/DOUBLER. (M)Jun 20, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030517Web · corrodedFTW - FORWARD CABIN SUBFLOOR CORRODED AT FLOOR SUPPORT LBL 9 STAITON 160 TO 200 AND HAS A PINHOLE FROM SCREW STATION 168. CUTOUT FLOOR WEB. FABRICATED NEW WEB. FABRICATED SPLICE. INSTALLED FLOOR WEB. INSTALLED SPLICE REPAIR. (M)Jun 20, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030492Floorboard · delaminatedFOUND CABIN FLOORBOARD STATION 617-674 STIFFENER DELAMINATED FROM BOTTOM. RESEALED DISBONDED STRIPS. (M)Jun 20, 2003 · N821NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030490Floor Panel · delaminatedCABIN FLOORBOARD DELAMINATED AND NUMEROUS INSERTS CORRODED. FABRICATED NEW FLOOR PANEL. (M)Jun 20, 2003 · N821NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030485Generator · failedSELECTED EMERGENCY POWER AFTER LEFT GEN FAIL. CAPTAINS ATTITUDE FLAGS IN VIEW AND UNPOWERED EMER AC AND EMG DC ANNUNCIATOR LIGHTS REMAINED OUT AND ALL INDICATIONS WERE BUSSES POURED FOR EMERGENCY AC AND DC. PERFORMED OPS CHECKS ON EMERGENCY POWER SYSTEM, NO Jun 20, 2003 · N823NK · Doug DC982 · AC Generation SystemSDR MWEA030249Frame · damagedLOWER CARGO COMPARTMENT FRAME FORMER AT STATION 427 BETWEEN LONGERONS 28 & 28 LEFT HAS AN OVERSIZED HOLE FOR THE SKIN ATTACHING FASTENER. FABRICATED AND INSTALLED NEW FORMER.Jun 20, 2003 · N808ME · Doug DC982 · Fuselage Main, FrameSDR MWEA030248Intercostal · corrodedLITE CORROSION ON TOP OF INTERCOSTAL BETWEEN STATION 769-788 AND BETWEEN LONGERON 27-28 RIGHT. FABRICATED AND INSTALLED INTERCOSTAL.Jun 20, 2003 · N808ME · Doug DC982 · Fuselage Miscellaneous StructureSDR MWEA030247Cargo Track · corrodedVARIOUS SPOTS OF LIGHT CORROSION ON MID-PIT RIGHT SIDE CARGO TIE DOWN RAIL FROM FRAME STATION 693-788. FABRICATED AND INSTALLED NEW SECTION RAIL.Jun 20, 2003 · N808ME · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR GTIA030541Structure · corrodedFTW - FOUND MID PIT FS 635 STRINGER 29R DOVE TAIL CORRODED. FABRICATED DOVE TAIL SUPPORT. (M)Jun 19, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030522Floor Support · corrodedFTW - FORWARD CABIN FLOOR SUPPORT LBL 6 STATION 168.75 TO 205 CORRODED. REMOVED FLOOR SUPPORT. FABRICATED NEW SUPPORT. INSTALLED SUPPORT. (M)Jun 19, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030521Floor Support · corrodedFTW - FOUND FORWARD CABIN FLOOR SUPPORT RBL 6 STATION 168.75 TO 205 CORRODED. REMOVED FLOOR SUPPORT. FABRICATED NEW SUPPORT. INSTALLED SUPPORT. (M)Jun 19, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030520Floor Support · corrodedFTW - FORWARD CABIN FLOOR SUPPORT STATION 200 RBL 6 TO LBL 22 CORRODED. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)Jun 19, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030519Floor Support · corrodedFTW - FOUND FORWARD CABIN FLOOR SUPPORT STATION 197 LBL 8 TO LBL 40 CORRODED. REMOVED FLOOR SUPPORT. FORMED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)Jun 19, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030518Floor Support · corrodedFTW - FOUND FORWARD CABIN FLOOR SUPPORT LBL 10 STATION 197 TO 256 CORRODED. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)Jun 19, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030513Floorboard · delaminatedFTW - FOUND RIGHT AFT LAVATORY FLOORBOARD DELAMINATED. FABRICATED NEW FLOORBOARD. (M)Jun 19, 2003 · N821NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030491Intercostal · corrodedFOUND MID PIT FS 630 STRINGER 28R INTERCOSTAL CORRODED. FABRICATED NEW T-ANGLE. (M)Jun 19, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20030674Clamp · looseDFW - FLT 1347 - EN ROUTE STL-MSY, AT LEVEL OFF ALTITUDE 33,000 FEET, PRESSURIZATION FLOW LIGHT ILLUMINATED WITH RATE OF CLIMB AT MAXIMUM INDICATION. BOTH PACKS WERE IN AUTO WITH BOTH FLOW INDICATION AT LOW. INITIATED RAPID DESCENT AND DEPLOYED OXYGEN MASKS.Jun 18, 2003 · N16545 · Doug DC982 · Air Distribution SystemSDR AALA20030668Connector · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, CEILING EMERGENCY EXIT LIGHTS ABOVE ROWS 8-11 INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT BATTEYR CONNECTION. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jun 18, 2003 · N227AA · Doug DC982 · Light System WiringSDR AALA20030669Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS ON WALL ACROSS FROM FORWARD LAVATORY INOPERATIVE. REPLACED EMERGENCY EXIT LIGHTS ASSEMBLY ON WALL ACROSS FROM FORWARD LAVATORY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jun 18, 2003 · N227AA · Doug DC982 · Emergency LightingSDR GTIA030546Stop Fitting · corrodedFTW - FOUND AFT VAULT DOOR LOWER STOPS CORRODED. REMOFED TWO EACH DOOR STOPS. INSTALLED NEW STOPS. (M)Jun 18, 2003 · N821NK · Doug DC982 · Passenger/Crew DoorsSDR GTIA030532Floor Panel · delaminatedFTW - FOUND FORWARD LAV INBOARD SECTION FLOOR PANEL DELAMINATED AND CORRODED AROUND EDGES. REPAIRED DELAMINATION. (M)Jun 18, 2003 · N821NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030524Floorboard · corrodedFTW - FOUND CABIN FLOORBOARD FS 160-200 LBL 24 INCHES DELAMINATED AND CORRODED INSERTS AND FASTENERS. REMOVED FLOORBOARD. FABRICATED NEW PANEL INSTALLED NEW FLOORBOARD. (M)Jun 18, 2003 · N821NK · Doug DC982 · Fuselage Floor PanelSDR GTIA030523Floor Support · corrodedFTW - FOUND CABIN FLOOR SUPPORT CORRODED FS 160-190 LBL 7 INCHES. REMOVED FLOOR SUPPORT. FABRICATED NEW SUPPORT. INSTALLED FLOOR SUPPORT. (M)Jun 18, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030501Pan · crackedFTW - AFT CARGO DOOR, UPON REMOVAL OF BRACKET FOUND CRACK IN RADIUS OF CARGO DOORS PAN AT LOWER FORWARD CORNER. STOP DRILLED. FABRICATED REPAIR DOUBLER. INSTALLED REPAIR DOUBLER. (M)Jun 18, 2003 · N821NK · Doug DC982 · Cargo/Baggage DoorsSDR MWEA030246Door Frame · corrodedMID CARGO DOOR JAMB HAS SEVERAL SPOTS OF LITE CORROSION AROUND FASTENER HOLES ON DOUBLER BETWEEN STATION 645-685. FABRICATED AND INSTALLED DOUBLER.Jun 18, 2003 · N808ME · Doug DC982 · Fuselage Main, StructureSDR ASAA0380498Power Supply · inoperativeAFT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED ASSOCIATED POWER SUPPLY. LIGHTS THEN OPERATED PROPERLY. (M)Jun 17, 2003 · N935AS · Doug DC982 · Emergency LightingSDR GTIA030555Longeron · corrodedFOUND MID PIT STATION 636-655 STRINGER 30-29L CORROSION AT FASTENERS. REMOVED LONGERON 30 FROM STATION 588 TO 665. FABRICATED NEW LONGERON SECTION. INSTALLED NEW LONGERON. (M)Jun 17, 2003 · N821NK · Doug DC982 · Fuselage Main, Longeron/StringerSDR GTIA030556Longeron · corrodedFOUND MID PIT STATION 655 674 STRINGER 30 CORROSION AT FASTENERS. FABRICATED NEW LONGERON SECTION FROM STATION 665 TO STATION 798. FABRICATED NEW LONGERON SPLICE. INSTALLED SPLICE. INSTALLED STRINGER 30. (M)Jun 17, 2003 · N821NK · Doug DC982 · Fuselage Main, Longeron/StringerSDR GTIA030554Longeron · corrodedFTW - FOUND FORWARD PIT STATION 450 TO 494 L30, LONGERON FLANGES CORRODED ON UPPER AND LOWER SURFACES. REMOVED 01 LONGERON 30 BETWEEN STATION 475 FOUND TO BE OUT OF LIMITS. LOCATED AND DRILLED NEW LONGERON 30. INSTALLED NEW LONGERON 30. FABRICATED NEW LONGEJun 17, 2003 · N821NK · Doug DC982 · Fuselage Main, Longeron/StringerSDR GTIA030526Skin · corrodedFTW - FOUND MID PIT STATION 750 STRINGER 29R-28R CORROSION ON SKIN. CUT SKIN TO FOM SIZE OF SKIN CUTOUT IS 7.5 INCHES BY 11 INCHES. CORROSION REMOVAL WITHIN ALLOWABLE LIMITS. FABRICATED REPAIR PARTS 1 EACH FILLER, 1 EACH DOUBLER, 2 EACH FINGER DOUBLER. INSJun 17, 2003 · N821NK · Doug DC982 · Fuselage Main, Plate/SkinSDR GTIA030514Stringer · corrodedFTW - MID PIT STATION 769-775 STRINGER 30 CORRODED AND FASTENERS CORRODED. (M)Jun 17, 2003 · N821NK · Doug DC982 · Fuselage Main, Longeron/StringerSDR MEX2003247Pulley · failedDURNG SLATS CABLE ADJUSTMENT WAS FOUND RUBBING BETWEEN CABLE PULLEYS OF SLAT NR '0', LOCATED IN THE RT OF THE SLAT DRIVE MECHANISM. BOTH PULLEYS WERE REPLACED AND GAINED ENOUGH SEPARATION. CABLE DEFLECTION WAS MEASURED, FOUNDED 25/34 INCHES, WITHIN LIMITS IAJun 17, 2003 · N491SH · Doug DC982 · Leading Edge Slat Control SystemSDR MEX2003227Relay · failedDURING TRANSIT CHECK WAS DETECTED CIRCUIT BREAKER BATTERY CHARGER WITHOUT INDICATION. THE BATTERY CHARGER, BATTERIES AND RELAY R2-56 WERE REPLACED, TESTS PERFORMED IAW 24-30-01, ALL CORRECT.Jun 16, 2003 · N1003X · Doug DC982 · Battery/Charger SystemSDR GTIA030529Support · corrodedFTW - AFT PIT STATION 1117 STRINGER 30-29L FRAME SUPPORT CORRODED. FABRICATED ANGLE REPAIR. INSTALLED REPAIR ANGLE. (M)Jun 15, 2003 · N821NK · Doug DC982 · Fuselage Miscellaneous StructureSDR GTIA030508Frame · corrodedFTW - FOUND AFT PIT STATION 1079 STRINGER 28L-28R FRAME CORRODED. REMOVED CORRODED FORMER ANGLE. FABRICATED REPAIR ANGLES. INSTALLED REPAIR ANGLE AND FRAME ANGLE. (M)Jun 15, 2003 · N821NK · Doug DC982 · Fuselage Main, FrameSDR GTIA030493Frame · corrodedAFT PIT STATION 1022 STRINGER 28L-29L FRAME CORRODED. CUT OUT DAMAGED AREA. FABRICATED REPAIR. INSTALLED REPAIR. (M)Jun 15, 2003 · N821NK · Doug DC982 · Fuselage Main, FrameSDR GTIA030482Floor Panel · corrodedAFT PIT STATION 1117-1155 STRINGER 18L FLOOR WEB CORRODED. FABRICATED REPAIR DOUBLER. INSTALLED REPAIR DOUBLER. (M)Jun 15, 2003 · N821NK · Doug DC982 · Fuselage Floor Panel
Back to Mcdonnell Douglas DC-9-82