Mcdonnell Douglas DC-9-82
Service difficulty reports · 23,866
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC982' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC982' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0380383Mount · corrodedOKC - DURING 30K CHECK, FOUND GALLEY MOUNT CORRODED. REPLACED MOUNT. (M)SDR ASAA0380379Floor Support · corrodedOKC - DURING 30K CHECK, FOUND FLOOR SUPPORT CORRODED AT FS 196. REPLACED DAMAGED SUPPORT PER SRM 51-10-4. (M)SDR ASAA0380376Skin · dentedOKC - DURING 30K CHECK, FUSELAGE DENTED AND GOUGED AT FS 1190. INSTALLED DOUBLER PER SRM 53-04. (M)SDR ASAA0380378Bulkhead · crackedOKC - DURING 30K CHECK, FOUND AFT PRESSURE BULKHEAD FORWARD FACE IS CRACKED AT OP MOST RIVETS. REPLACED WEB AT BL 0 PER SRM 51-30-5. (M)SDR ASAA0380377Vane Cap · crackedOKC - DURING 30K CHECK, FOUND RIGHT OUTBOARD FLAP NR 3 VANE CAP CRACKED ON UPPER SURFACE. REPLACED VANE CAP PER SRM 51-30-1 AND 2. (M)SDR AALA20030483Light · inoperativeDURING OVERNIGHT MAINTENANCE, CEILING EMERGENCY EXIT LIGHTS AT ROWS 18-21 INOPERATIVE. REPAIRED CEILING EMERGENCY EXIT LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030476Battery · inoperativeDURING OVERNIGHT MAINTENANCE, CEILING EMERGENCY EXIT LIGHT AT ROW 18-29 INOPERATIVE. RESEATED EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030309Floor Support · corrodedCABIN STA 203, RBL 5, LBL 19 FLOOR SUPPORT CORRODED. REMOVED FLOOR SUPPORT, FABRICATED NEW FLOOR SUPPORT AND INSTALLED FLOOR SUPPORT.SDR GTIA030308Structure · corrodedCABIN STA 218, LBL 43, SUBFLOOR CORRODED. CUT OUT DAMAGE. DRILL AND LOCATE DOUBLER. INSTALLED DOUBLER.SDR GTIA030307Floorboard · crackedPAX CABIN FLOORBOARD CRACKED/BROKEN AT FS 218-294 LEFT BETWEEN SEAT TRACKS 1 AND 2. REMOVED FLOORBOARD, DRILL AND LOCATE AND INSTALLED FLOORBOARD.SDR GTIA030316Skin · damagedFORWARD ENTRY DOOR HOLD OPEN PIN CUTOUT SKIN DAMAGED, REPAIRS. UPON FURTHER INSPECTION THE PAN COMMON TO THE ENTRY DOOR HOLD PIN ASSY WAS FOUND TO BE CRACKED. FABBED -13, -11 DOUBLERS, -3 PLATE. LOCATED AND DRILLED NEW PAN. INSTALLED FORWARD ENTRY DOOR HOLSDR GTIA030312Floor Panel · brokenCABIN FLOOR PANEL AT FS 200-237 CENTER IS BROKEN IN CENTER. FABRICATED NEW FLOOR PANEL.SDR GTIA030261Blade · damagedL/P 60611-3 NR ENG DAMAGE ON FAN BLADE. L/P 60612-1 NR 2 ENG FWD OF REAR CLAM SHELL ACOUSTIC LINER DAMAGED AT 12 OCLOCK POSITION TO 9 OCLOCK POSITION. L/P 60612-3 NR 2 ENG FOUND ACOUSTIC LINER DAMAGE JUST AFT OF IGV, FWD OF C1, 12 OCLOCK POSITION. C/A: L/PSDR GTIA030322Fire Seal · crackedNR ENGINE APRON UPPER 6TH FROM FORWARD FIRE SEAL CRACKED. REMOVED CRACKED FIRE SEAL. FABRICATED NEW FIRE SEAL. INSTALL NEW FIRE SEAL.SDR GTIA030304Fireseal · crackedNR 2 ENGINE APRON UPPER 4TH FROM FORWARD FIRESEAL CRACKED. REMOVED CRACKED FIRESEAL. FABRICATED NEW FIRESEAL. INSTALLED NEW FIRESEAL.SDR GTIA030306Skin · corrodedFOUND AFT PIT STATION 1174 CORRODED AT SKIN WITH INNER/OUTER DOUBLER, LOWER DOOR JAMB. INNER SKIN FOUND TO BE OUT OF LIMITS. FABRICATED REPAIR DOUBLERS. INSTALLED 2 DOUBLERS. (M)SDR GTIA030336Frame · corrodedAFT PIT CORRODED AT FRAME, STATION 1079 - 1309. REMOVED CORROSION ON FRAME STATION 1231-1271 AND 1309. FOUND OUT OF LIMITS. CUTOUT DAMAGE IF FRAME FROM STATION 1231. INSTALLED NEW SECTION OF FRAME. SPLICE REPAIR STATION 1231. CUTOUT DAMAGE AREA OF FRAME SDR GTIA030317Fitting · crackedAFT PIT STA 1007 1 FITTING SUPPORT END CARGO TRACK ATTACH TO INTERCOASTAL RIGHT SIDE IS CRACKED. REMOVED CRACKED FITTING. HOLES LOCATED AND DRILLED ON NEW FITTING. INSTALLED NEW FITTING.SDR GTIA030318Door Frame · corrodedAFT PIT STA 1155 FORWARD DOOR FRAME CORRODED. REMOVED DAMAGED AREA. FORMED REPAIR. INSTALLED 2 REPAIR PIECES.SDR GTIA030319Fitting · corrodedAFT PIT LT FITTING SUPPORT LOWER DOOR JAMB, 2 EA CORRODED STA 1155, STA 1211. REMOVED 2EA LT FITTINGS. LOCATED AND DRILLED NEW FITTINGS. INSTALLED NEW FITTING.SDR GTIA030329Bracket · corrodedAFT PIT STA 1155 TO STA 1117. 4 EA BRACKETS SUPPORT RIGHT CARGO TRACK CORRODED (ATTACH TO THE BEAM). FABRICATED 4 EA ANGLES.SDR GTIA030337Skin · corrodedFOUND MID CARGO FS 690 STATION STRINGER 30-29L SKIN CORRODED. AFTER FURTHER EVALUATION, MORE DAMAGE FOUND ON EXTERNAL SKIN. FABRICATED EXT DOUBLER. FABRICATED INT DOUBLER. INSTALLED REPAIR DOUBLERS. (M)SDR GTIA030320Intercostal · corrodedMID CARGO FS 695, INTERCOASTAL CORRODED AND TOOL MARKS STR 29L. FABRICATED NEW INTERCOSTAL. PRIOR TO STEP 5, REMOVED DAMAGED INTERCOSTAL. INSTALLED INTERCOSTAL.SDR GTIA030321Stringer · corrodedFORWARD CARGO STRINGER 28L CORRODED FS 428. FAB STRAP. INSTALLED STRAP.SDR GTIA030311Web · corrodedAFT PIT STA 1150 TO STA 1220 WEB CORRODED. FAB NEW WEB.SDR GTIA030305Web · corrodedFORWARD CARGO CEILING AREA WEB CORRODED FS 226, STR 18R. FABRICATED WEB DOUBLER. INSTALLED DOUBLER AND FILLER.SDR GTIA030295Web · corrodedE AND E BAY FS 162 CEILING AREA WEB CORRODED LBL 51. DRILL AND LOCATED DOUBLER. INSTALLED DOUBLER.SDR AALA20030456Sensor · defectiveDFW - FLT 1698 - EN ROUTE DFW-IAD, ON CLIMB-OUT AT 24,000 FEET, TAIL COMPARTMENT TAIL HIGH LIGHT ILLUMINATED. FOLLOWED CHECKLIST AND LIGHT EXTINGUISHED. LIGHT ILLUMINATED AGAIN WHEN POER ADVANCED. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED HIGH SDR AALA20030453Flashlight · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, FORWARD EMERGENCY EXIT PORTABLE FLASHLIGHT DIM. REPLACED FORWARD EMERGENCY EXIT PORTABLE FLASHLIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030454Battery · inoperativeDFW - DURING OVERNIGHT MIANTENANCE, CEILING EMERGENCY EXIT LIGHTS BY AFT GALLEY DOOR INOPERATIVE. RESEATE CEILING EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR ZW0A0304301Connector · looseTHE EGRESS LIGHTS WERE INOPERATIVE AT ROWS 14 TO 16, AND THE EMERGENCY EXIT SIGNS WERE INOPERATIVE ABOVE BOTH FWD OVERWING EXIT DOORS. RESEATED LIGHT STRIP CONNECTOR AT ROW 14 FOR THE EGRESS LIGHTS, AND RESEATED THE BATTERIES IN THE POWER SUPPLY FOR THE EXIT SDR MEX2003134Starter · failedAIRCRAFT RETURNED TO PLATFORM, DURING RIGHT ENGINE STARTING WERE NOT N1, N2 AND OIL PRESSURE INDICATIONS. DURING REVISION WAS DETECTED THAT SHAFT COUPLING STARTER WAS BROKEN. IT WAS REPLACED IAW MM, TESTS CORRECT.SDR AALA20030455Seal · leakingDFW - FLT 1938 - DFW-CLE, ON CLIMB-OUT, TAIL COMPARTMENT HIGH LIGHT ILLUMINATED. FOLLOWED CHECKLIST AND LIGHT EXTINGUISHED WHEN LEFT PACK WAS TURNED OFF. LIGHT ILLUMINATED AGAIN WHEN POWER ADVANCED TOWARD CLIMB POWER. RETARDED POWER AND LIGHT EXTINGUISHED. SDR AALA20030446Harness · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT 7D INOPERATIVE. REPLACED EMERGENCY LIGHT PIGTAIL ASSEMBLY AT SEAT 7D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030447Harness · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT IGHT AT 10D INOPERATIVE. REPLACED EMERGENCY LIGHT PIGTAIL ASSEMBLY AT SEAT 10D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030451Battery · inoperativeDURING OVERNIGHT MAINTENANCE, OVERHEAD EMERGENCY EXIT LIGHTS IN FIRST CLASS THROUGH FRONT OF COACH SECTION INOPERATIVE. SECURED OVERHEAD EMERGENCY EXIT LIGHT BATTERY CONTACTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030449Battery · inoperative- DURING OVERNIGHT MAINTENANCE, BOTH FORWARD OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. TIGHTENED FORWARD OVERWING EMERGENCY EXIT LIGHT BATTEYR CONTACTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030443Flashlight · inoperativeSEA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLASHLIGHT INOPERATIVE. REPLACED EMERGENCY EXIT FLASHLIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030440Wire · inoperativeORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT L1 DOOR INOPERATIVE. REPAIR EMERGENCY EXIT LIGHT WIRE SPLICE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR MWEA030165Symbol Generator · defectiveDURING CLIMBOUT FIRST OFFICERS NAVIGATION DISPLAY AND PRIMARY FLIGHT DISPLAY FAILED AND CAPTAIN'S NAVIGATION DISPLAY SHOWS BLUE LINES, FOLLOWED BY SYMBOL GENERATOR NR 2 CIRCUIT BREAKER POPPPED. REMOVED AND REPLACED FIRST OFFICERS NR 2 GENERATOR COMPUTER AND CSDR GTIA030339Door Frame · corrodedFTW - AFT LOWER CARGO, LOWER DOOR JAMB CUTOUT CORROSION AT DOUBLER REPAIR, ATTACH TO O/B BEAM. REMOVED DOOR JAMB BEAM STATION 1114 TO 1249. LOCATED AND DRILLED NEW JAMB BEAM STATION 1114 TO STATION 1249. INSTALLED NEW JAMB BEAM. (M)SDR AALA20030430Connector · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT 1721 INOPERATIVE. CLEANED EMERGENCY EXIT LIGHT BATTERY CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030428Light · inoperativeORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT 16D INOPERATIVE. REPLACED EMERENCY EXIT LIGHT ASSEMBLY AT 16D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030425Module · inoperativeTPA - DURING OVERNIGHT MAINTENANCE, FORWARD CABIN EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED FORWARD EMERGENCY EXIT LIGHT MODULE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030421Battery · inoperativeORD - DURING OVERNIGHT MAINTENANCE, AFT SEAT MOUNTED EMERGENCY EXIT PATH LIGHTS AT ROW 20 INOPERATIVE. REPLACED AFT EMERGENCY EXIT PATH LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030328Beam · corrodedMID LOWER CARGO, LWR DOOR JAMB OB BEAM CORRODED. REMOVED DOOR JAMB BEAM L28R STA 598 TO 733. DRILLED AND LOCATED HOLES IN NEW BEAM, INSTALLED DOOR JAMB BEAM.SDR GTIA030310Door Frame · corrodedFORWARD CARGO LOWER DOOR JAMB CUTOUT CORRODED (DOOR PAN). FABRICATED -19, -21 REPAIR SPLICES. DRILLED AND LOCATED NEW PAN. INSTALLED DOOR JAMB PAN. INSTALLED FWD AND AFT REPAIR SPLICE.SDR AALA20030418Battery · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, CEILING EMERGENCY EXIT LIGHTS AT ROWS 28-29 AND LEFT SERVICE DOOR IN CEILING PANEL INOPERATIVE. RESEATED EMERGENCY EXIT LIGHT BATTERY FOR ROWS 22-29. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR CALA0300169Frame · crackedINSPECTION FOUND A 1 INCH CRACK IN FRAME AT STA 1418, L2L TO L2R. REMOVED AND REPLACED BELTFRAME IAW SRM 51-30-05.SDR ASAA0380293Angle · crackedOKC - DURING 30K CHECK, FOUND LEFT WING LEADING EDGE FRAME TIE IS CRACKED AT UPPER AFT END. REPLACED ANGLE PER SRM 51-10-2. (M)
Back to Mcdonnell Douglas DC-9-82