Mcdonnell Douglas MD-11
Service difficulty reports · 7,956
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM11011484Generator · activatedOXYGEN GENERATOR ACCIDENTLY DEPLOYED AT SEATS 55AB. REPLACED SAME.SDR DLM11011483Generator · activatedOXYGEN GENERATOR ACCIDENTLY DEPLOYED AT SEAT 11 G. REPLACED SAME.SDR DLM11011482Generator · activatedOXYGEN GENERATOR ACCIDENTLY DEPLOYED AT SEAT 11 C. REPLACED SAME.SDR 01FDEA00803Wire · burnedDURING UPLOAD CTR CARGO LATERAL PWR ROLLER POPPED E/B (09-01-01). FOUND BURNED WIRES.SDR DLM11011459Coffeemaker · damagedTRANSFER FROM CMI - MID GALLEY COFFEEMAKER NR 4 HANDLE INOP. FOUND COFFEEMAKER BAG/POUCH TRAY BOTTOM BURNED/MELTED. REPLACED SAME.SDR DLM11011439Sensor · failedAIR RETURN NRT DUE A ICE SENSOR FAIL. REPLACED NR PSC, CHECKS GOOD.SDR DLM11011425Smoke Detector · damagedSMOKE ALARM AFT TOILET CAPT SIDE BATT LOW. DETECTOR DAMAGED. REMOVED AND REPLACED SAME. OPS OK.SDR DLM11011424Oven · dirtyAFT MOST OVEN ON F/O SIDE OF A/C HAD BURNING SMELL WHEN ON. TURNED OFF, SMELL WENT AWAY. FOUND REMNANTS OF MELTED PLASTIC BAG IN AFT RT OVEN. CLEANED OVEN. INSPECTED OVEN HARNESS AND CONNECTOR. REINSTALLED, OPS OK. NO ABNORMAL SMELL NOTED. HARNESS AND CSDR DLM11011415Door · missingFOUND BY MTC EXTERNAL ELECTRICAL CONNECTION DOOR MISSING - REPLACED SAMESDR DLM11011405Odor · detectedODOR OF BURNING RUBBER IN CABIN DURING CRUISE. UNABLE TO LOCATE OR DUPLICATE.SDR AALA20011688Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGHTING AT L4 DOOR INOPERATIVE. REPLACED LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM11011362Smoke Detector · malfunctionedLAV F - SMELLED OF CIGARETTE SMOKE BUT NO ALARM. FOUND USED DISCARDED CIGARETTE IN LAV-F WASTE BASKET. NO EVIDENCE OF BURNING GARBAGE. WASTE CONTAINER FIRE BOTTLES CHECK OKAY AND HEAT SENSE INDICATORS ARE NORMAL. AREA UNDER LAV SINK OKAY. REPLACED OVERHEASDR DLM11011359Oven · malfunctionedAFT GALLEY FWD OVEN GIVING OFF BURNING SMELL. REPLACED OVEN.SDR DLM11011357Flow Valve · failedON CLIMBOUT OF ATL NR 1 PACK RUNNING ABOUT 40 DEGREES C HOTTER THAN PACKS 2 AND 3. NR 1 PACK WAS CYCLING ON AND OFF WITH A FLOW LIGHT. WENT TO MANUAL AND SECURED NR 1 PACK. CFDS FAULTS NR 1 PACK FLOW CONTROL VALVE. REPLACED SAME. LEAK AND OPS CHECK OK. RSDR 01FDEA00742Connector · shortedDURING HYD OPS USING AUX PUMPS FOR FLT CNTRL RIGGING, FOUND NR 1 AUX HYD PUMP ELECTRICAL CONNECTOR SHORTED CAUSING SPARKS AND SUBSEQUENT FIRE TO SURROUNDING AREA. REMOVED AND REPLACED WIRINGS PER WDM 20-31-15.SDR DLM11011358Control Panel · failedAFTER T/O, A/P & A/T WOULD NOT ENGAGE. REPLACED GCP PER MM.SDR DLM11011328Rccb · failedWHILE VERIFYING BOTH RCCBS B1-1649 AND B1-391 TO BE IN OPEN STATE REFERENCE MEL 28-22-06E L2 FWD AUX PUMP LOW PRESSURE CONDITION RCCB BI-1649 L2 PUMP WOULD NOT GO TO THE OPEN CONDITION, STUCK IN THE CLOSE CONDITION. REMOVED AND REPLACED RCCB B1-1649 PER M/M PESDR EVA003Engine · flamed out1. AIRCRAFT B-16103 DURING CRUISE 5 MINUTES BEFORE TOD, "ENG 2 RPM LO" LEVEL 2 ALERT APPEARED. FOLLOWED CHECK LIST, AIR RESTART WAS SUCCESSFUL.2. ON GROUND, CHECK CFDS NO RELATED FUALT FOUND.3. CHECK ENGINE CONDITION ALL NORMAL. EEC TEST PASS. PERFORM ENGINE RSDR 01FDEA00654Doubler · crackedCENTER LAND GEAR LT BULKHEAD DOUBLER BETWEEN BS 1361-1381 CRACKED. REMOVED AND REPLACED SRM 51-31-01 VOL 2.SDR 01FDEA00653Doubler · crackedSNRM 220 CENTER LAND GEAR RH BULKHEAD DOUBLER BETWEEN BS 1361-1381 FND CRACKED. ** S/D ** COMINGSDR DLM11011263Fan · noisyORIGINAL DEPARTED NGO. ELECTRICAL FUMES DETECTED ONE HOUR INTO FLIGHT. STRONGEST ODOR IN FORWARD CABIN CLOSE TO THE STAR WARS PANEL DIVERTED TO NARITA. LANDING WEIGHT 425,000LBS. PERFORMED ENTIRE CABIN INSPECTION. FOUND NR 2 RECIRCULATION FAN MAKING EXCESSIVSDR DLM11011256Wire · shorted02 MASKS ON LANDING DROPPED - FOUND WIRING SHORTED AT 4L F/A SEAT - REPAIRED SAMESDR DLM11011254Wire · shortedO2 MASKS DROPPED ON LANDING, SEVERAL MASKS PULLED BY PASSENGERS AND O2 GENERATORS STARTED. FOUND WIRING SHORTED TO CABIN LIGHTS SIDEWALL CONTROL WIRING AT 4L F/A SEAT. REPAIRED WIRING. STOWED O2 MASKS PER M/M 35-21 AND GENERATORS REPLACED.SDR G60A057Spar Cap · crackedFOUND RIGHT WING REAR SPAR LOWER CAP HAS 3 INCH LONG CRACK IN RADIUS FROM RS 1046.2 TO RS 1049.9. (M)SDR DLM11011249Chiller · defectiveHEAVY ELEC BURNING SMELL FROM FWD GALLEY NOTED IN COCKPIT ALSO FLT ATTENDANT PULLED BREAKERS. CA FD OVEN 102 HAS ELEC SMELL. REPLACED OVEN AND CHILLER, CKS GOOD.SDR DLM11011211Actuator · malfunctionedCLIMBING THROUGH 10,000 MSL ON TAKEOFF, A SMOKE DETECTOR IN THE CREW REST FACILITY ACTIVATED. WITH THE DOOR OPEN FROM THE COCKPIT COULD SMELL A HOT ODOR. RETURNED TO KENNEDY. UNEVENTFUL LANDING. INSPECTED A/C FOR EVIDENCE OF ANY FIRE, NONE FOUND. SUSPECT PSDR DLM11011156Lens · damagedPASSENGER SEAT 121B EMERGENCY TRACK FLOOR LIGHT DAMAGED. REPLACED LENS.SDR DLM11011152Battery · dischargedLED ON EMERGENCY FLASHLIGHT AT 4R NOT FLASHING. REPLACED BATTERY LIGHT, OPN CHECKS NORMAL.SDR 01FDEA00531Seat Track · damagedMAIN DECK FLOOR TRACK DAMAGED AT BS Y=800 X= 47. *S/D* REMOVED AND REPLACED SEAT TRACK PER SRM 51-70-00 FIG 1 VOL 1.SDR DLM11011131Battery Pack · dischargedNR 1 EMERGENCY LIGHT BATTERY FAILED TEST. REPLACED SAME.SDR DLM11011099Wire · disconnectedON L/O FOUND EMERGENCY LIGHTS AT SEAT 32¥ 33¥ 34, 35 INOP. RECONNECTED WIRE SPLICE AT SEAT 32¥, ALL SEAT LIGHTS OK.SDR DLM11011072Unknown · odorSLIGHT ODOR OF SMOKE IN FWD BUSINESS CLASS LT AISLE AT O/H BIN LEVEL. ODOR EVENTUALLY DISSIPATED AFTER SELECTING ECON OFF. NO SMOKING TO OFF AND FASTEN SEAT BELTS TO OFF. REMOVE CEILING PANELS AT ROW 2/3/4 AND INSP OVERHEAD. REMOVE NO SMOKING/FASTEN SEAT BESDR DLM11011015O-Ring · leakingNR ONE ENGINE LOSING OIL. QTY DOWN TO ONE. FOUND O-RING AT BOTTOM OF OIL PRESSURE TRANSMITTER TO BE LEAKING. REPLACED O-RING. REPLACED TRANSMITTER AS PRECAUTION.SDR DLM11011006Battery · missingFOUND DOOR 4L AFT LAV SMOKE ALARM INOP. FOUND 9V BATTERY HAD BEEN REMOVED AND MISSING. INSTALLED BATTERY AND SECURED COVER BY SAFETY WIRE. NO EVIDENCE OF FIRE IN LAV AND SMOKE ALARM OPS OK.SDR DLM11011004Transducer · failedNR 10 TIRE BLOWN ON LANDING. REPLACED NR 10 ANTISKID TRANSDUCER.SDR DLM11010983Battery · dischargedON EMERGENCY LIGHT TEST NR 3 BATTERY FOUND BAD. REPLACED SAME.SDR 01FDEA00459Actuator · out of adjA/C MADE AIR TURNBACK DUE DEFLECT AILERON DISAGREE ALERT. LT O/B ACTUATOR ADJUSTED AND SAFETIED PER MXP 27-2 METHOD "D".SDR DLM11010956Battery · dischargedLAV 1L SMOKE DETECTOR WILL NOT TURN OFF. REPLACED BATTERY.SDR 01FDEA00415Fairlead · brokenMAIN DECK CONTROL CABLE FAIRLEAD FOUND BROKEN AT BS 575, RBL 30 BELOW FLOOR PANEL.SDR DLM11010900Battery Pack · dischargedEMERGENCY LIGHT BATTERY 2 LOW MESSAGE IN COCKPIT DURING TEST. REPLACED BATTERY PACK.SDR DLM11010888Cover · missingPAX AND F/A RECEIVED SHOCK WHEN ADJUSTING READING LIGHT AT SEAT 4G. ADJUSTED READING LIGHT WITH COVER ON. NO SHOCK, PRESENT LIGHT OPS NORMAL.SDR DLM11010809Light · inoperativeON PRE FLT FOUND TEST SWITCH EMERGENCY LIGHT NR 6 BATTERY LOW MESSAGE ON. REMOVED AND REPLACED SEAT 54B LIGHT ASSY AND HARNESS SYSTEM CHK'S NORMAL PER MM, OK FOR SVC.SDR DLM11010803Chiller · faultyFRC-250-XX000 SEE LOGBOOK FOR DETAILS - G4 CHILLER SHUT DOWN DUE ELEC SMELL. REMOVED AND REPLACED CHILLER.SDR DLM11010802Pump · failedNR 3 HYDRAULIC, RIGHT EDP FAILED FOR TEMP. REPLACED BOTH NR 3 HYDRAULIC PUMPS. REPLACED SYSTEM FILTERS. SERVICED, BLED AND LEAK CHECKED SYSTEM.SDR DLM11010775Wire · chafedSEATS 1CG 2 CG AND 3CG INOP ELECTRICALLY FOUND POWER CABLE AND EMPOWERMENT CABLE CHAFED AND SIGNS OF ACRING. REPLACED CABLE.SDR DLM11010715Control Cable · icedON DESCENT WHILE ATTEMPING TO DEPLOY SPOILERS NO SPOILERS DEPLOYED ON RIGHT SIDE. ALSO DID NOT GET RIGHT SPOILERS ON GROUND AND WHEN PLACING FLAPS TO 15 DEGREES GOT ROLLING MOMENT AND FLAP ASYMMTRY LIGHT D305007004. FOUND LARGE AMOUNT OF ICE BUILDUP IN RIGHTSDR DLM11010686Light · inoperativeEMER LIGHTT BATTERY 6 LO MSG DISPLAYED AFTER EMER LIGHT TEST. CLEARED SHORT AT SEAT 46AB. MSG CLEARED. WHITE LIGHT AT SEAT 46AB INOP FWD TO MCO AND PLAC PER MEL 33-50-03B RR 33-50-03B SEAT/SIDEWALL MOUNTED EMERGENCY ESCAPE PATH LIGHTING SYSTEMSDR DLM11010676Slide · unserviceablePER SERVICE CK NR 3 INSPECTION INDICATED SLIDE AT R4 DOOR ABOVE GIRT BAR, THE CORDS WERE LOOSE AND THE SAFETY BROKEN ON THE PIN. REMOVED AND REPLACED R4 DOOR SLIDE. SN ON 0303 SN OFF 0430 DELTA PN 250007930.SDR DLM11010658Tank · collapsedALL LAVS INOP. CREW HEARD LOUD BANG IN AFT CARGO COMP. 1 1/2 HOURS FROM ARRIVAL IN LAX. FOUND TANK COLLAPSED, AND CRACKED WILL REQUIRE REQUIRE REPLACEMENT P/N 380001285 NASI LAX. WILL ALSO NEED APPROXIMATELY 25 FT OF BELLY BLANKTS REPLACED FWD OF AFT LAV TANK.SDR DLM11010653Fan · malfunctionedIR- AFTER LANDING LAV SMOKE ANNUNCIATES FOR 10 SECONDS WITH HIGH PITCED TONE IN 4R LAV. INSPECTED 4R LAV. NO EVIDENCE OF SMOKE. HIGH PITCHED WHINE FOUND TO BE AFT GALLEY CHILLER VENT FAN. PULLED AND COLLARD C/B FWD TO MCO AND PLACARDED.
Back to Mcdonnell Douglas MD-11