SDR DLM11010608Projector · overheatedNR 2 PROJECTOR OVERHEATED AND EMITTED FUMES BEFORE DEPARTURE - REPLACED SAMESDR DLM11010597Coffeemaker · shortedMID GALLEY COFEEMAKER SHORTED OUT. (283) VISIBLE SPARKS FLEW, C/B POPPED. REPLACED COFFEEMAKERSDR DLM11010595Bulb · overheatedLIGHT BY 4L DOOR WAS EXTREMELY HOT AND THE FLIGHT ATTENDANT SMELLED BURING PLASTIC UNTIL SHE TURNED IT OFF. INSPECTED AND RELAMPED OPS NORMALSDR 01FDEA00268Actuator · failedAFT FLAP RETRACTION, AILERON DISAGREE ALERT DISPLACY. RED TAB PROC ACCOMP. DEFLECTED AILERON SYS INOP. RIGHT O/B ACT FAILED AND REPLACED WITH FIXED PUSHROD PER METHOD B.SDR DLM11010563Oven · smokeOVENS IN AFT GALLEY STARTED TO SMOKE. OVENS CLEANED AND OPERATED FOR 15 MINUTES. CHECKS OKSDR DLM11010547Control Unit · failedRIGHT OUTBOARD FLAP POS INDICATOR INOP. RESET FCC NR 1 ALSO RESET FLAP INDICATION CKS OKSDR DLM11020393Power Supply · dischargedON PREFLIGHT CHECK, EMERGENCY LIGHTS TEST FAILED. EMER LIGHT BATT 1 LO MSG ON SYN DISPLAY. REPLACED NR 1 EMERGENCY LIGHT POWER SUPPLY UNIT PER M/M. EMERGENCY LIGHTS TEST PASS.SDR DLM11010549Compressor · overheatedPRIOR TO DEPARTURE FWD GALLEY CHILLER COMPRESSOR MAKING VERY LOUD NOISE AND GETTING WARM HOT / SMOKE - REPLACED CHILLER.SDR DLM11010522Fmc · failedIN CRUISE LAV SMOKE AND CREW REST SMOKE DETECTORS TRIPPED. ELECTRICAL SMELL NOTED IN COCKPIT FWD AND MID CABINS. SMOKE ALSO NOTED IN CREW REST AREA. T/S FOUND FMC 2 INOP. FOUND EVIDENCE OF ELECTRICAL SMOKE ON TOP OF UNIT. REMOVED AND REPLACED UNIT RTS PASSSDR 20010423CW003Ignition Switch · failedPILOT REPORTED NR 2 ENGINE, LOW RPM WARNING APPEARED, LEVEL 2 WITH N 1 25 PER CENT, EGT, 100 THEN WENT TO 0. NR 2, 40 PER CENT, OIL QTY 20, RECOVERED AFTER IGN OVRD SELECTED DURING STARTED DESCENT. MAINTENANCE RAN NR 2 ENGINE WITH BOTH A AND B IGNITSDR DLM11010497Oven · smokeIN FLIGHT, FLIGHT ATTENDANT REPORTS SMELL AND SMOKE IN AFT GALLEY. AIRCRAFT DEVERTED TO LONDON (LGW). MAINTENANCE RAN OVENS AND CHILLER, FOUND SMELL COMING FROM CHILLER AND RIGHT AFT OVEN. DISCONNECTED CANNON PLUGS AND PULLED C/B ON BOTH COMPONENTS. MAINTENANCSDR DLM11010493Oven · odorFLT ATT NOTIFIED CREW SMOKE SMELL IN AFT GALLEY. TURNED GALLEY POWER OFF. SMELL CONTINUED SMOKE DISAPEARED. ACTIVATED CABIN BUS SWITCH TO OFF POSITION. FIRE SERVICE INSPECTED AREA ABOVE AFT GALLEY WITH THERMAL IMAGE DEVICE. NIL HOT SPOTS / DAMAGE NOTED.AREA ALSDR DLM11010489Power Supply · inoperativeWITH A/C POWER ON,EMERGENCY LIGHTS AT ROWS 30-35 STAYED ILLUMINATED WITH EMERGENCY LIGHTS SELECTED OFF. REMOVED AND REPLACED POWER SUPPLY AND BATTERY. CHECKS OKSDR DLM11010481Fan · overheatedDIVERTED INTO CDB FOR SMOKE SMELL IN CABIN. WITH CABIN BUSES OFF SMELL DIMINISED. FOUND PAX OUTLET FAN AT FAULT. DEACTIVATED SAME. FAN R/R IN ANC ON LOG PAGE 379080001. FAN P/N 605457-8 S/N 18-7444SDR AALA20010614Fire Detector · malfunctionedDFW - FLT 963 - EN ROUTE DFW-GRU - AT GATE DURING ENGINE START APU COMPRESSOR STALLED SEVERAL TIMES ACCOMPANIED BY APU FIRE WARNING INDICATION. ACCOMPLISHED EMERGENCY PROCEDUES PER CHECKLIST. APU LIGHT EXTINGUISHED AFTER PROCEDURES ACCOMPLISHED. REPLACED APSDR DLM11010441Oven · smokeOVEN MID GALLEY RIGHT SIDE PRODUCES HEAVY SMOKE-MAYBE SPILLED FOOD. CABIN SERVICE CLEANED SPILLED FOOD FROM INTERIOR OF OVEN HEATED OVEN 15 MIN. NO SMOKESDR WRLA200105Fire Loop · malfunctionedPASSING FLIGHT LEVEL 230, ON CLIMB-OUT RECEIVED ENGINE FIRE WARNING ON NR 3 ENGINE, ENGINE SHUT DOWN, NO OTHER FIRE INDICATION FIRE WARNING LIGHT STAYED ON FOR 20 MINUTES. FOUND FDCU3 FAULTING BOTH A AND B LOOP DETERMINED THE R4 RESPONDER B LOOP DEFECT REMOVESDR AALA20010529Light · malfunctionedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT FIRST CLASS CABIN DIM. REPLACED EMERGENCY EXIT LIGHT STRIP AT FIRST CLASS CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010528Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 8G THROUGH 15G DIM. REPAIRED EMERGENCY EXIT LIGHT WIRE SPLICE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010527Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 20G THROUGH 38G DIM. REPAIRED EMERGENCY EXIT LIGHT WIRE SPLICE AT SEAT 38G. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010526Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT R2 DOOR DIM. REPAIRED EMERGENCY EXIT WIRE SPLICE AT R2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM11010410Fuel Control · failedON TAKE OFF AFTER PROF SELECTED AT 1000FT AGL AUTO THROTTLES RETARDED THROTTLES 1 AND 3 - REPLACED FCC 1SDR WRLA200104Indicator · inoperativeNR 3 OIL INDICATION WENT FROM 9 QUARTS AT LEVEL OFF TO 3 QUARTS IN TWO MINUTES, SHUT DOWN ENGINE AND RETURNED BASE. SERVICED 1 QT DEFERRED NR 3 OIL QUANTITY INDICATION PER MEL M70MR10-17 MR MEL 79-31-1. NR 3 ENGINE OIL PRESSURE INDICATED NORMAL EN ROUTE WIMMSDR DLM11010403Oxygen Mask · deployedUPON ENGINE SHUT DOWN ALL OVERHEAD MASKS DEPLOYED WITH AIR SYSTEM IN MANUAL AT AC POWER TRANSFER - NO FAULTS FOUND - UNABLE TO DUPLICATESDR DLM11010375Control Unit · damagedFOUND CENTER CARGO COMPARTMENT CARGO CONTROL UNIT DAMAGED DUE TO AN OVERHEAT CONDITION. ITEM WAS DISCOVERD WHILE WORKING AN MCO ON A DAMAGED CONNECTOR TO A POWER DRIVE UNIT IN THE CENTER CARGO BAY. IT APPEARS THAT THE OVERHEAT CONDITION WAS THE RESULT OF SHORSDR 01FDEA00175Fire Warning · activatedON LANDING, AC WAS NOT DECELERATING WITH AUTO BRAKES, USED MAX REV THRUST ON ALL 3 ENG. NR 3 COMPRESSOR STALL AND A FIRE ALERT ENSUED. STOP SHUT DOWN NR 3 ENG AND RAN FIRE CK, ONE BOTTLE FIRED.SDR DLM11010365Control Panel · burnedFOUND WIRING HARNESS G013 DAMAGED WHILE TROUBLESHOOTING MCO C/NS C02271036 AND 333401016. NUMEROUS WIRES BURNED APROX 18 INCHES FROM P1-618 TO AFT ATTENDANT PANEL AT 4L DOOR. REPAIRED WIRES 141-22, 119-22, 114-20, 121-22, 97-22, 117-20, 23-24, 1-22 AND 131-20SDR WRLA200103Transmitter · failedAFTER TAKEOFF, DEFLECTED AILERONS WOULD NOT RETRACT, AIR RETURNED TO KSEA BASE. MAINTENANCE PROCEDURES COMPLIED WITH, AIRCRAFT DEPARTED. FLAP HANDLE POSITION TRANSMITTER POSITION TRANSMITTER WAS CHANGED TO CORRECT PROBLEM. FLAP HANDLE POSITION TRANSMITTER. SDR DLM11010359Oven · overheatedBULKHEAD NEXT TO G-7 GALLEY IS CHARRED, OTHER AREAS SHOW BURN DAMAGE. VISUAL INSPECTED AFT GALLEY AREA FOUND OVEN 327 AND 328 DUAL OVEN SHOWED BURN. OTHER AREA NO ABNORMALITY OBSERVED. SUSPECT OVEN PROBLEM. OVEN 327 AND 328 REPLACED.SDR DLM11010356Spar · corrodedPITTING CORROSION WAS DISCOVERED IN THE LT AND RT SIDES OF THE HORIZ STAB REAR SPAR UPPER CAPS. THE CORROSION WAS CONTAINED IN THE BARREL NUT HOLES NEAR THE ROOT OF THE STAB. DAMAGE WAS REWORKED PER ERA 397231-14.SDR AALA20010366Connector · brokenDFW - DURING OVERNIGHT MAINTENANCE, FLOOR PATH EMERGENCY EXIT LIGHT AT RIGHT AFT CABIN DIM. REPLACED FLOOR PATH EMERGENCY EXIT LIGHT CONNECTOR AT SEAT 38C. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM11010350Mount · damagedAFT ENGINE MOUNT DAMAGED FROM WEAR RESULTING FROM CONTACT WITH BLIND RIVET TAILS ON BOTH THE LT AND RT SIDES. ER/A 396704-14.SDR DLM11010326Engine · overservicedTHE NUMBER TWO ENGINE WAS RUNNING AT 149 DEG CELSIUS TO 152 DEG CELSIUS IN CRUISE. THIS WAS APPROX 40 DEG CELSIUS ABOVE NR 1 AND NR 3. THE FLIGHT (79) DIVERTED TO PDX. FOUND ENGINE OIL OVERSERVICED. REMOVED OIL TO PROPER LEVEL.SDR AALA20010633Duct · rupturedDFW - FLT 946 - SHORTLY AFTER TAKEOFF, NR 3 AIR SYSTEM DIFFERENTIAL MESSAGE ILLUMINATED. NR 3 BLEED AIR PRESSURE OFF LIGHT ALSO ILLUMINATED. LANDED DFW WITHOUT FURTHER INCIDENT. REPLACED NR 3 INBOARD DUCT. LEAK CHECKS GOOD. SYSTEM GROUND CHECKED NORMAL OPSDR AALA20010302Fitting · corrodedTUL - FOUND LEFT CENTER GEAR TRUNNION SUPPORT FITTING HAS CORROSION ON THE BOTTOM MATING SURFACE, FS 1520. REMOVED CORROSION PER ESO 41000 S/N 48553 DATED 2/21/2001. (M)SDR AALA20010303Structure · corrodedTUL - FOUND CORROSION IN THE HOLES AND ON THE SURFACE OF THE RIGHT AFT MATING SURFACE OUTBOARD OF AFT HOLE. REMOVED CORROSION PER ESO 41000 S/N 48553 DATED 2/21/2001. (M)SDR DLM11010307Handle · mislocatedL1 DOOR OPEN CONTROL HANDLE FOUND WITH INSUFFUCIENT CLEARANCE TO CREW REST MODULE. MODIFIED STRUCTURE PER ERA 388450-14.SDR DLM11010305Handle · mislocatedL1 DOOR OPEN HANDLE FOUND TO HAVE INSUFFICIENT CLEARANCE TO CREW REST MODULE. MODIFIED MODULE PER ERA 388450/14.SDR DLM11010304Handle · mislocatedL1 DOOR OPEN HANDLE FOUND TO HAVE INSUFFICIENT CLEARANCE TO CREW REST MODULE. MODIFIED MODULE PER ERA.SDR DLM11010277Chiller · overheatedMCO MID GALLEY G-4 CHILLER INOP. DUE REPORTS OF ELECTRICAL SMELL INSPECT CHILLER WIRING INSTALLATION FOR SIGNS OF OVERHEATING / CHAFING / ETC. INSPECTED WIRING INSTALLATION, NO TROUBLE FOUND. CHILLER ITSELF HAS A STRONG ELECTRICAL SMELL. SHOP INSPECTION RESDR AALA20010634Duct · rupturedDFW - FLT 946 - SHORTLY AFTER TAKEOFF, NR 3 MANIFOLD FAIL LIGHT ILLUMINATED. LANDED DFW WITHOUT FURTHER INCIDENT. REPLACED NR 3 INBOARD DUCT PYLON. LEAK CHECKS GOOD. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 01FDEA00119Block · crushedAFT P-F CONV DURING T/O CREW NOTED A LEVEL ONE AC TIE 1 OFF ALERT. FOUND A BLOCK OF THE CONCRETE BALLAST HAD BROKEN FREE OF AN LD3 CONTAINER IN POS 1 LEFT IN THE FWD LWR CARGO COMP. THE BLOCK ROLLED THRU THE FWD CARGO COMP AND PASS THRU BULKHEAD AND LODGED ISDR WRLA200102Packing · leakingNR 3 OIL QTY INDICATION 1 QT IN FLIGHT TEMP AND PRESS. OK IN CRUISE. PRESSURE LOW ON DESCENT SHUTDOWN NR 3 ENGINE. PERFORMED VISUAL INSPECTION OF THE OIL TANK, LINES/CHIP DETECTORS. PRATT WHITNEY REP ALSO LOOKED OVER ENGINE DELTA ENGINE SHOP PERFORM GEAR BSDR DLM11010158Chiller · malfunctionedSTRONG ELECTRICAL SMOKE SMELL REPORTED IN AREA OF BC GALLEY ODOR REPORTED BY PAX AND CREW. MID GALLEY A/C AND D/C CIRCUIT BREAKERS PULLED AND COLLARD FOUND CHILLER CYCLING ON AND OFF. CHILLER FWD TO MCO AND PLAC PER MEL 25-22-01. DUE TO CREW REPORTS OF CHILSDR WRLA01001B-Nut · looseLOST ELEVEN QUARTS OF ENGINE OIL ON NR 3 ENGINE IN THE MATTER OF TWO MINUTES OF FL370, FROM THAT POINT, WE LOST ONE QUART EVERY FIFTEEN MINUTES. AT TWO QUARTS REMAINING A PRECAUTIONARY SHUTDOWN OF THE NR 3 ENGINE WAS MADE. AFTER SHUTDOWN NINE QUARTS DECREASESDR DLM11010105Blade · failedNR 3 ENG COMPRESSOR STALL AND PERFORMED REJECTED T/O AT APPROX 160. ENGINE SHUT DOWN BY FLT CREW. BLADE FAILED. POSSIBLY DUE TO SOFT FOD.SDR DLM11010068Circuit Breaker · failedBUS AC AND DC GROUND OFF LEVEL ONE ALERT. WITH MTC APPR RESET POPPED C/B C-14 UPPER MAINT PANEL POPPED AGAIN IN 4 MINUTES. DIVERTED TO PDX. REPLACED RCCB B1-1347 AGSTR CONTROL EPCU BITE THRU CFDS NO FAULTS R-T-S- NML.SDR DLM11010067Battery Pack · inoperativeDURING PREFLT FOUND FWD B/C EMERGENCY LIGHTS INOP. REPLACED PWR SUPPLY.SDR 20010202CW002Panel · inoperativePILOT REPORTED ELECTRICAL BURNING ODOR DURING CLIMB, A IL 300, SMOKE APPEARED IN THE COCKPIT CAUSED FUEL DUMPED AND AIR RETURNED TO LAX. MAINTENANCE AND INSPECTION COCKPIT INDICATORS ALL C/B ARE CLOSED OPEN OVHD PANEL, MAINT PANEL AND AVIONICS PANEL, EXAMINEDSDR AALA20010039Connector · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT AISLE LIGHT AT FIRST CLASS CABIN INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Back to Mcdonnell Douglas MD-11