Mcdonnell Douglas MD 83
Service difficulty reports · 3,415
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD83' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD83' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YYFA20140321001Handset · noisyFORWARD HANDSET LOUD SQUEAL FEEDBACK WHEN ATTEMPTING TO ANSWER IN FLIGHT, DOES NOT OCCUR ON THE GND.SDR WX0A071882Skin Panel · damagedINTERIM REPAIR DOUBLER INSTALLED AT FS 1205, L28L - L28R ID 36 TO BE R & R WITH A PERMANENT REPAIR AT NEXT C CHECK. COMPLIED WITH PERMANENT REPAIR IAW ERO 5334-006A BELLY SKIN SPLICE, L26L TO L26R FROM STATION 1138.5 TO STATION 1279 ACCOMPLISHED, EMLA 5334406SDR 2014FA0000163Control Valve · crackedTHRUST REVERSER CONTROL VALVE HAS A PIN HOLE LEAK ON THE SIDE OF THE PRESSURE PORT.SDR WX0A071878Battery · dischargedAFT FLIGHT ATTENDANT`S FLASHLIGHT BLINKING LIGHT IS DEAD. R & R BATTERY IAW MM 25-60-00.SDR WX0A071879Battery Pack · dischargedEMERGENCY LIGHTS FROM ROW 32 TO 36 INOPERATIVE. R & R BATTERY PACK B5-107 IAW AMM 33-53-00, OPERATIONS CHECKED GOOD.SDR WX0A071877Battery · dischargedAFT FLIGHT ATTENDANT STATION EMERGENCY FLASHLIGHT INOPERATIVE. R & R EMERGENCY FLASHLIGHT BATTERY IAW AMM 25-60-00, OPERATIONS CHECKED GOOD.SDR YYFA20140313002Engine · power lossRIGHT ENG LOW N2 RPM INDICATION ON START, RETURNED TO GATE.SDR YYFA20140314001Acm · malfunctionedSHORTLY AFTER DEPARTURE BOTH AIR CYCLE MACHINES FAILED TO ESTABLISH CABIN PRESSURE.SDR WX0A071876Power Supply · defectiveL1 & R1 EMERGENCY LIGHTS WORKING INTERMITTENTLY. R & R EMERGENCY LIGHT BATTERY PACK POWER SUPPLIES FWD 2 RT IAW AMM 33-53-00.SDR WX0A071873Power Supply · inoperativeEMERGENCY LIGHT BATTERY PACK INOPERATIVE AT FWD MOST POSITION. R & R POWER SUPPLY TO THE NR 1 EMERGENCY LIGHT IAW AMM 33-51-01. OPERATIONS CHECKED GOOD OF PACK & OVERHEAD LIGHTS. R & R FOR TROUBLESHOOTING IAW LOG PAGE 457250, THIS HAD NO EFFECT ON THE FWD SDR WX0A2014031171874Indicator · malfunctionedUNSCHEDULED FUEL BURN DURING CLIMB OUT & CRUISE. TANK INDICATION READ 1200 - 1500 LBS HIGHER THAN ACTUAL FUEL LOAD. WHEN TRANSFERRING FUEL TO THE LT WING NOTICED THAT WHEN STICKING TANK, THE RT TANK WAS EMPTY BUT THE INDICATION WAS READING 1500 LBS. REMOVESDR WX0A201403111874Door Frame · corrodedAFT CARGO DOOR CUTOUT FRAME BEAM CORRODED IN SEVERAL AREAS, BS 1174 - 1193. REMOVED CORROSION. LOCATED, DRILLED & INSTALLED TITANIUM DOUBLER, SPACERS, STRIP & NUTSTRIP IAW SRM 53-05 FIGURE 123.SDR WX0A071872Battery · dischargedFWD CABIN EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES, OPERATIONS CHECKED GOOD IAW AMM 33-53-01.SDR YYFA20140310001Csd · faultyRIGHT CSD RED LINED FREQ DROPPED BELOW 390 RISE VERY HIGH.SDR WX0A071868Attach Bracket · crackedCRACKED ATTACH BRACKET, FWD PIT AT STATION 256 UNDER LT FLOOR TRANSITION ANGLE. R & R ATTACH BRACKET IN FWD PIT AT STATION 256 UNDER LT FLOOR TRANSITION ANGLE IAW SRM 51-30-2 & 51-30-5.SDR WX0A071867Fitting · crackedFRAME CLIP IN AFT ACCESSORY BAY RT SIDE BETWEEN LONGERON 11 - 12, STATION 1437. R & R FRAME CLIP IN AFT ACCESSORY BAY RT SIDE BETWEEN LONGERON 11 - 12, STATION 1437 IAW SRM 51-30-2 & 51-30-5.SDR WX0A071869Reservoir · defectiveON PREFLIGHT, DISCOVERED ACFT RT WING SLIDE CHECK PRESS ON FAP. R & R RT OVERWING SLIDE INFLATION RESERVOIR IAW AMM 25-62-46-020-050A.SDR WX0A071871Battery · dischargedFWD FLIGHT ATTENDANT PORTABLE EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BATTERIES & OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.SDR WX0A071870Inlet · dirtyBOTH LAVATORY SMOKE DETECTORS ACTIVATED JUST AFTER TAKEOFF. FLIGHT ATTENDANT SAID THEY SAW A HAZE & A PAX SAID HE SMELLED SMOKE. IAW LP 453075 FOR OPERATIONS CHECK OF LAVATORY SMOKE DETECTORS, OPERATIONS GOOD. COMPLIED WITH WORK ORDER 218333 FOR CBN ODOR &SDR WX0A071866Battery · dischargedFWD CABIN OVERHEAD EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY BATTERIES AT FWD GALLEY POSITION IAW 33-53-00, OPERATIONS CHECKED GOOD.SDR YYFA20140225001Interphone · weakFIRST OFFICER, PILOT TO PILOT INTERPHONE VERY WEAK.SDR WX0A071865Battery · dischargedFLASHLIGHT AT FWD ATTEND L1 INOPERATIVE LIGHT DOES NOT BLINK. REPLACED BATTERIES, OPERATION CHECKED GOOD IAW MM 25-60-00.SDR YYFA20140226002Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK INOPERATIVE STATION 211 CTR & STATION 836R, R & R.SDR WX0A071862Battery Pack · dischargedROW 5 EMERGENCY LIGHT INOPERATIVE. R & R BATTERY PACK IAW AMN 33-53-07.SDR WX0A071861Doubler · chafedLEFT OTBD FLAP, INBD VANE LE DOUBLER IS CHAFED. REMOVED DAMAGED DOUBLER & INSTALLED PERMANENT REPAIR IAW SRM 51-70-2 PARA 18B PG 91-95.SDR YYFA20140222001Pa System · faultyL2 PA SYS HAS STATIC NOISE.SDR YYFA20140226001Windshield · crackedFIRST OFFICER WINDSHIELD OUTER PANE CRACKED, R & R.SDR WX0A071860Sign · defectiveSELF-ILLUMINATED EXIT SIGNS AT AFT OVERWING EXIT FAILED COMPARATOR CHECK DURING C-CHECKSDR YYFA20140221001Pa System · faultyPA CANNOT BE HEARD AT L1 INTERPHONE DURING FLIGHT, WORKS ON GND DURING TAXI.SDR WX0A071864Battery Pack · dischargedFWD OVERWING FLOOR LEVEL EMERGENCY LT & RT EXIT LIGHTS INOPERATIVE. R & R BATTERY PACK IAW AFF 33-53-00 & WDM-51-14, OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.SDR WX0A071863Battery · dischargedLT & RT AFT OVERWING EMERGENCY EXIT LIGHTS WILL NOT TEST. R & R BATTERIES IN EMERGENCY LIGHTS BATTERY PACK B5-105, STATION 909R. OPERATIONS CHECKED GOOD IAW AMM 33-53-00 & WDM 33-53-01.SDR WX0A071851Battery · dischargedLEFT & RT AFT OVERWING EMERGENCY EXIT LIGHTS WILL NOT TEST. R 7 R BATTERIES IN EMERGENCY LIGHTS BATTERY PACK B5-105, STATION 909R. OPERATIONS CHECKED GOOD IAW AMM 33-53-00 & WDM 33-51-12.SDR WX0A071855Skin · chafedVERTICAL STABILIZER SKIN, PN 5912166-11, BONDED DOUBLER, PN 5912166-89, CHAFED. FABRICATED NEW SKIN PANEL IAW EA NR 15570 & INSTALLED IAW SRM 51-30-2.SDR WX0A071854Skin · chafedVERTICAL STABILIZER SKIN, PN 5912166-185, CHAFED. REMOVED DAMAGED SECTION OF SKIN & INSTALLED REPAIR DOUBLER & FAIRING PLATE IAW SRM 55-01 FIG 4.SDR WX0A071850Battery · dischargedFORWARD FLOOR OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R BATTERIES IN BATTERY PACK IAW AMM 33-53-00, CHECKED GOOD.SDR YYFA2014021818001Pa System · faultyFWD GALLEY PA & AFT PA BOTH HAVE FEEDBACK.SDR WX0A071856Scuff Plate · crackedMID PIT RT AFT SCUFF PLATE IS CRACKED. FABRICATED NEW MID PIT RT AFT SCUFF PLATE IAW SRM 51-10-4.SDR YYFA20140217001Interphone · defectiveL2 INTERPHONE HANDSET WILL NOT TRANSMIT.SDR WX0A071859Sign · defectiveSELF-ILLUMINATING EXIT SIGNS AT FWD OVERWING EXIT FAILED COMPARATOR CHECK DURING C-CHECK.SDR WX0A071858Skin · dentedAFT CARGO DOOR SKIN DENTED OUT OF SRM LIMITS. REMOVED DAMAGED SECTION OF DOOR SKIN & INSTALLED REPAIR DOUBLER & FILLER IAW SRM 52-05 FIG 66.SDR WX0A071857Floor Panel · corrodedAFT CARGO FLOOR PANEL HAS CORROSION ON UPPER & LOWER SURFACES, OUT OF SRM LIMITS. LOCATED & DRILLED REPLACEMENT PANEL PN 5936603-1 IAW SRM 51-10-4.SDR YYFA20140216001Handset · faultyL2 HANDSET FEEDBACK.SDR WX0A071853Battery · dischargedROW 32 & 33 EMERGENCY LIGHTS INOPERATIVE. R & R ROW 32 & 33 EMERGENCY LIGHT BATTERIES IAW AMM 33-53-00, OPERATIONS CHECKED GOOD.SDR WX0A071852Battery · dischargedEMERGENCY AISLE LIGHTS INOPERATIVE 28 - 29. REPLACED BATTERIES IN BATTERY PACK FOR EMERGENCY AISLE LIGHTS 28 - 29. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.SDR WX0A071849Skin · dentedRIGHT ELEVATOR TAB UPPER SURFACE DENT OUT OF LIMITS 6 INCHES FROM INBD END. REMOVED DAMAGED SKIN, FABRICATED FILLER & DOUBLER & HOT BONDED IAW SRM 51-70-2 PARA 13. TAP TEST COMPLIED WITH SRM 51-70-02, NO DEFECTS NOTED.SDR YYFA20140213001Pa System · faultyFORWARD PA GETTING FEEDBACK. AFT PA GETTING FEEDBACK.SDR WX0A071847Cusp Web · crackedAFT CABIN RT CUSP WEB CRACKED STATION 1290. REMOVED DAMAGED WEB, FABRICATED A REPLACEMENT WEB, LOCATED, DRILLED & INSTALLED WEB, DOUBLERS, SHIMS & INSTALLED IAW SRM 53-05 FIGURE 131A-22.SDR WX0A071848Cusp Web · corrodedAFT CABIN RT CUSP WEB CORRODED STATION 1220. REMOVED DAMAGED WEB, LOCATED, DRILLED, & INSTALLED A REPLACEMENT WEB IAW SRM'S 51-10-4, 51-30-3 & 51-30-2 FIGURE 1.SDR WX0A071846Battery Pack · dischargedFORWARD LOWER EMERGENCY EXIT HATCH LIGHTS INOPERATIVE. REPLACED POWER SUPPLY BATTERY PACK. OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.SDR YYFA20140211001Interphone · inoperativeL2 PA INTERPHONE INOPERATIVE.
Back to Mcdonnell Douglas MD 83